Search NASA⌕ Search

SEARCH · Search NASA

Results for “total variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Understanding Oxide–Metal Interactions During Hot Isostatic Pressing to Diffusion Bond Aluminum Alloy 6061 Plates

The interaction between Mg, Si, and Al 2 O 3 during hot isostatic pressing diffusion bonding of aluminum alloy 6061 (AA6061) plates was investigated through thermodynamic calculations and experimental microstructural characterization. Thermodynamic calculations as functions of temperature, pressure, and composition revealed that the interaction among Mg, Si, and Al 2 O 3 yields Mg 2 Si and either MgO + Al or MgAl 2 O 4 + Al, facilitating the reduction of Al 2 O 3 and allowing Al/Al metallic bonds to form. Total pressure variation had a negligible influence on the oxygen partial pressure, and consequently, the reaction product formation. Oxygen partial pressure variation as a function of temperature and initial amount of Al 2 O 3 determined the formation of either MgO or MgAl 2 O 4 . Experimental Hot Isostatic Pressure (HIP) bonding at 723 K and 833 K under a constant pressure of 1017 atm documented the cooling rate-dependent formation of β–Mg 2 Si precipitates. High-resolution transmission electron microscopy imaging and selected area electron diffraction patterns verified the formation of β–Mg 2 Si and MgO at the interface but did not detect MgAl 2 O 4 . In conclusion, findings from this study clarify the role of thermochemical interactions in oxide disruption and bonding mechanisms during HIP diffusion bonding of AA6061 and provide guidance for optimizing joining processes for monolithic nuclear fuel assemblies.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An improved multislope MUSCL scheme for solving shallow water equations on unstructured grids

In this paper we describe an improved vector manipulation multislope monotone upstream-centred scheme for conservation laws (MUSCL) reconstruction for solving the shallow water equations on unstructured grids. This improved MUSCL reconstruction method includes a bigger stencil for the interpolation and saves time for determining the geometric relations compared to the original vector manipulation method, so it is computationally more efficient and straightforward to implement. Four examples involving an analytical solution, laboratory experiments and field-scale measurements are used to test the performance of the proposed scheme. It has been proven that the proposed scheme can provide comparable accuracy and higher efficiency compared to the original vector manipulation method. With the increasing of the number of cells, the advantage of the proposed scheme becomes more apparent.

42 ENGINEERING↗

Electronic, magnetic, and magnetocrystalline anisotropy properties of light lanthanides

Theoretical understanding of interactions between localized and mobile electrons and the crystal environment in light lanthanides is important because of their key role in much needed magnetic anisotropy in permanent magnet materials that have a great impact in automobile and wind turbine applications. We report electronic, magnetic, and magnetocrystalline properties of these basic light lanthanide elements studied from advanced density functional theory (DFT) calculations. We find that the inclusion of onsite 4f electron correlation and spin orbit coupling within the full-potential band structure is needed to understand the unique magnetocrystalline properties of these light lanthanides. The onsite electron correlation, spin orbit coupling, and full potential for the asphericity of charge densities must be taken into account for the proper treatment of 4f states. We find the variation of total energy as a function of lattice constants that indicate multiple structural phases in Ce contrasting to a single stable structure obtained in other light lanthanides. The 4f orbital magnetic moments are partially quenched as a result of crystalline electric field splitting that leads to magnetocrystalline anisotropy. The charge density plots have similar asphericity and environment in Pr and Nd indicating similar magnetic anisotropy. However, Ce and Sm show completely different asphericity and environment as both orbital moments are significantly quenched. In addition, the Fermi surface structures exemplified in Nd indicate structural stability and unravel a cause of anisotropy. The calculated magnetocrystalline anisotropy energy (MAE) reveals competing c-axis and in-plane anisotropies, and also predicts possibilities of unusual structural deformations in light lanthanides. The uniaxial magnetic anisotropy is obtained in the double hexagonal closed pack structures of the most of the light lanthanides, however, the anisotropy is reduced or turned to planar in the low symmetry structures. As a result, through crystal field calculations we also illustrate the crystal field ground state 4f multiplets of light lanthanides.

36 MATERIALS SCIENCE↗

A comparison of EBSD based strain indicators for the study of Fe-3Si steel subjected to cyclic loading

The current work aims at proposing an EBSD-based indicator for fatigue damage of a Fe-3Si steel. At the same time direct observation of dislocation structures is provided by electron channelling contrast imaging (ECCI). The investigation consisted in processing the EBSD data from patterns collected on specimen subjected to low cycle fatigue. It revealed two different regimes depending on the applied total strain variation which is explained by the identification of the dislocations structures and their evolution. At low strain variation, strain accommodation occurs by planar glide of dislocations uniformly distributed throughout the grains. No misorientation evolution is observed. At higher strain variation, the vein-channel structure is observed within the grain and the wall-channel structure in the vicinity of grain boundaries. The misorientation between these two dislocation structures is evaluated at about 0.7° which is detected by the EBSD analyses and explains the increase of the different misorientation based criteria. The EBSD study enables also the prediction of crack initiation mode. Finally, this study points out the limits of the EBSD technique as no misorientation evolution is detected at small strain variation. Indeed, the lattice distortion is too weak to be detected by conventional EBSD. - Highlights: • Microstructure investigation of the fatigue behaviour of an iron-silicon steel • Use of cECCI to investigate the fatigue dislocations structures • Characterisation of local plastic accommodation through EBSD misorientation criteria.

36 MATERIALS SCIENCE↗

Phosphatidic acid: an emerging versatile class of cellular mediators

Abstract Lipids function not only as the major structural components of cell membranes, but also as molecular messengers that transduce signals to trigger downstream signaling events in the cell. Phosphatidic acid (PA), the simplest and a minor class of glycerophospholipids, is a key intermediate for the synthesis of membrane and storage lipids, and also plays important roles in mediating diverse cellular and physiological processes in eukaryotes ranging from microbes to mammals and higher plants. PA comprises different molecular species that can act differently, and is found in virtually all organisms, tissues, and organellar membranes, with variations in total content and molecular species composition. The cellular levels of PA are highly dynamic in response to stimuli and multiple enzymatic reactions can mediate its production and degradation. Moreover, its unique physicochemical properties compared with other glycerophospholipids allow PA to influence membrane structure and dynamics, and interact with various proteins. PA has emerged as a class of new lipid mediators modulating various signaling and cellular processes via its versatile effects, such as membrane tethering, conformational changes, and enzymatic activities of target proteins, and vesicular trafficking.

Biochemistry & Molecular Biology↗

Pyroelectric response mechanism of barium strontium titanate ceramics in dielectric bolometer mode: The underlying essence of the enhancing effect of direct current bias field

Pyroelectric response mechanism of Ba{sub 0.70}Sr{sub 0.30}TiO{sub 3} ceramics under dielectric bolometer (DB) mode was investigated by dielectric and pyroelectric properties measurement. The variations of total, intrinsic, and induced pyroelectric coefficients (p{sub tot}, p{sub int}, p{sub ind}) with temperatures and bias fields were analyzed. p{sub int} plays the dominant role to p{sub tot} through most of the temperature range and p{sub ind} will be slightly higher than p{sub int} above T{sub 0}. The essence of the enhancing effect of DC bias field on pyroelectric coefficient can be attributed to the high value of p{sub int}. This mechanism is useful for the pyroelectric materials (DB mode) applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Excitation energies along a range-separated adiabatic connection

We present a study of the variation of total energies and excitation energies along a range-separated adiabatic connection. This connection links the non-interacting Kohn–Sham electronic system to the physical interacting system by progressively switching on the electron–electron interactions whilst simultaneously adjusting a one-electron effective potential so as to keep the ground-state density constant. The interactions are introduced in a range-dependent manner, first introducing predominantly long-range, and then all-range, interactions as the physical system is approached, as opposed to the conventional adiabatic connection where the interactions are introduced by globally scaling the standard Coulomb interaction. Reference data are reported for the He and Be atoms and the H{sub 2} molecule, obtained by calculating the short-range effective potential at the full configuration-interaction level using Lieb's Legendre-transform approach. As the strength of the electron–electron interactions increases, the excitation energies, calculated for the partially interacting systems along the adiabatic connection, offer increasingly accurate approximations to the exact excitation energies. Importantly, the excitation energies calculated at an intermediate point of the adiabatic connection are much better approximations to the exact excitation energies than are the corresponding Kohn–Sham excitation energies. This is particularly evident in situations involving strong static correlation effects and states with multiple excitation character, such as the dissociating H{sub 2} molecule. These results highlight the utility of long-range interacting reference systems as a starting point for the calculation of excitation energies and are of interest for developing and analyzing practical approximate range-separated density-functional methodologies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First principle calculation in FeCo overlayer on GaAs substrate

In this work the first principle electronic structure calculation is reported for FeCo/GaAs thin film system to investigate the effect of orientation on the electronic structural properties. A unit cell describing FeCo layers and GaAs layers is constructed for (100), (110), (111) orientation with vacuum of 30Å to reduce dimensions. It is found that although the (110) orientation is energetically more favorable than others, the magnetic moment is quite large in (100) and (111) system compared to the (110) and is due to the total DOS variation with orientation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AUTOMATED VARIABLE STAR CLASSIFICATION USING THE NORTHERN SKY VARIABILITY SURVEY

We have identified 4659 variable objects in the Northern Sky Variability Survey. We have classified each of these objects into one of the five variable star classes: (1) Algol/{beta} Lyr systems including semidetached, and detached eclipsing binaries, (2) W Ursae Majoris overcontact and ellipsoidal variables, (3) long-period variables such as Cepheid and Mira-type objects, (4) RR Lyr pulsating variables, and (5) short-period variables including {delta} Scuti stars. All the candidates have outside of eclipse magnitudes of {approx}10-13. The primary classification tool is the use of Fourier coefficients combined with period information and light-curve properties to make the initial classification. Brief manual inspection was done on all light curves to remove nonperiodic variables that happened to slip through the process and to quantify any errors in the classification pipeline. We list the coordinates, period, Two Micron All Sky Survey colors, total amplitude variation, and any previous classification of the object. 548 objects previously identified as Algols in our previous paper are not included here.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-C-BRD-01: Multi-Centre Collaborative Quality Assurance Program for IMRT Planning and Delivery: Year 3 Results

Purpose: A multi-centre quality assurance program was developed to enable quality improvement by coupling measurement of intensity modulated radiotherapy (IMRT) planning and delivery performance for site-specific planning exercises with diagnostic testing. The third year of the program specifically assessed the quality of spine stereotactic body radiotherapy (SBRT) planning and delivery amongst the participating centres. Methods: A spine SBRT planning exercise (24 Gy in 2 fractions) was created and completed by participants prior to an on-site visit. The delivery portion of the on-site visit included spine SBRT plan delivery and diagnostic testing, which included portal image acquisition for quantification of phantom positioning error and multi-leaf collimator (MLC) calibration accuracy. The measured dose was compared to that calculated in the treatment planning system (TPS) using 3%/2mm composite analysis and 3%/3mm gamma analysis. Results: Fourteen institutions participated, creating 17 spine SBRT plans (15 VMAT and 2 IMRT). Three different TPS, two beam energies (6 MV and 6 MV FFF), and four MLC designs from two linac vendors were tested. Large variation in total monitor units (MU) per plan (2494–6462 MU) and dose-volume parameters was observed. The maximum point dose in the plans ranged from 116–149% and was dependent upon the TPS used. Pass rates for measured to planned dose comparison ranged from 89.4–100% and 97.3–100% for 3%/2mm and 3%/3mm criteria respectively. The largest measured MLC error did Result in one of the poorer pass rates. No direct correlation between phantom positioning error and pass rates overall. Conclusion: Significant differences were observed in the planning exercise for some plan and dose-volume parameters based on the TPS used. Standard evaluation criteria showed good agreement between planned and measured dose for all participants, however on an individual plan basis, diagnostic tests were able to identify contributing factors for poorer results, when using more stringent evaluation criteria. Funding from Cancer Care Ontario is acknowledged.

60 APPLIED LIFE SCIENCES↗

SU-E-T-303: Dosimetric Comparison of a LINAC Fallback Plan Generated From Tomotherapy System

Purpose: Quantitatively evaluate the Multi Criteria Optimization (MCO) based MLC step and shoot (sMLC) fallback plan derived from Tomotherapy of multiple lesions lung SBRT Methods: Inter-comparison of various IMRT planning systems tends to be difficult due to the vendor-specific functionalities. The methodology of defining dose constraints and beam geometries is challenging. Raysearch™ planning system offers an alternative replanning to deliver same intensity map from Tomotherapy without modifying original fluence. This intuitive comparison comes from the final fluence map converted without any embedded system dependent dose optimization. This planner independent approach could be utilized to study the merits of individual machines. The term “fallback” was utilized to (A) transfer plans in among treatment delivery systems; (B) maintain acceptable plan qualities; and (C) minimize the biological dose impact due to machine breakdown. The Tomotherapy specific DICOM RT dose and plan are retrieved into Raystation’s pre-defined sMLC protocol. Based on specific machine characteristics, same fluence maps were converted to generate equivalent deliverable segments. Therefore, the treatment plans were evaluated among two planning tools, Tomotherapy and MCO based sMLC delivery plans. Results: By converting the fluence map with the pre-defined machine characteristics, the 9-fields fallback plan has similar ITV coverage compared to the original Tomotherapy plan. ITV average doses, the D95 consisted of 0.9% variation. The total lung doses of fallback plan drifted from 17.4% to 30.5% which represents the limitations of the static beam delivery. D2 of fallback spinal cord increased from 22.4% to 36.4% but still within tolerances. Ipsilateral lung changed from 11.0% to 22.6%. Low dose region between ITVs presented increased dose to the normal lung tissues. Conclusion: Acceptable fallback plan for Tomotherapy SBRT has similar ITVs coverage, but lack of the normal tissues avoidance due to the limitation of geometrical factors to reduce doses in between ITVs.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-08: Four-Dimensional Cone-Beam CT Iterative Reconstruction with Time-Ordered Chain Graph Model for Non-Periodic Organ Motion and Deformation

Purpose: The purpose of this study is to propose a new concept of four-dimensional (4D) cone-beam CT (CBCT) reconstruction for non-periodic organ motion using the Time-ordered Chain Graph Model (TCGM), and to compare the reconstructed results with the previously proposed methods, the total variation-based compressed sensing (TVCS) and prior-image constrained compressed sensing (PICCS). Methods: CBCT reconstruction method introduced in this study consisted of maximum a posteriori (MAP) iterative reconstruction combined with a regularization term derived from a concept of TCGM, which includes a constraint coming from the images of neighbouring time-phases. The time-ordered image series were concurrently reconstructed in the MAP iterative reconstruction framework. Angular range of projections for each time-phase was 90 degrees for TCGM and PICCS, and 200 degrees for TVCS. Two kinds of projection data, an elliptic-cylindrical digital phantom data and two clinical patients’ data, were used for reconstruction. The digital phantom contained an air sphere moving 3 cm along longitudinal axis, and temporal resolution of each method was evaluated by measuring the penumbral width of reconstructed moving air sphere. The clinical feasibility of non-periodic time-ordered 4D CBCT reconstruction was also examined using projection data of prostate cancer patients. Results: The results of reconstructed digital phantom shows that the penumbral widths of TCGM yielded the narrowest result; PICCS and TCGM were 10.6% and 17.4% narrower than that of TVCS, respectively. This suggests that the TCGM has the better temporal resolution than the others. Patients’ CBCT projection data were also reconstructed and all three reconstructed results showed motion of rectal gas and stool. The result of TCGM provided visually clearer and less blurring images. Conclusion: The present study demonstrates that the new concept for 4D CBCT reconstruction, TCGM, combined with MAP iterative reconstruction framework enables time-ordered image reconstruction with narrower time-window.

60 APPLIED LIFE SCIENCES↗

Reexamining classical and quantum models for the D-Wave One processor: The role of excited states and ground state degeneracy

We revisit the evidence for quantum annealing in the D-Wave One device (DW1) based on the study of random Ising instances. Using the probability distributions of finding the ground states of such instances, previous work found agreement with both simulated quantum annealing (SQA) and a classical rotor model. Thus the DW1 ground state success probabilities are consistent with both models, and a different measure is needed to distinguish the data and the models. Here in this paper we consider measures that account for ground state degeneracy and the distributions of excited states, and present evidence that for these new measures neither SQA nor the classical rotor model correlate perfectly with the DW1 experiments. We thus provide evidence that SQA and the classical rotor model, both of which are classically efficient algorithms, do not satisfactorily explain all the DW1 data. A complete model for the DW1 remains an open problem. Using the same criteria we find that, on the other hand, SQA and the classical rotor model correlate closely with each other. To explain this we show that the rotor model can be derived as the semiclassical limit of the spin-coherent states path integral. We also find differences in which set of ground states is found by each method, though this feature is sensitive to calibration errors of the DW1 device and to simulation parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust COTS objective for diffraction-limited, high-NA, long front working distance imaging

We present a robust objective lens optimized for applications requiring both high numerical aperture (NA) and long front working distance imaging, comprised of all commercial-off-the-shelf (COTS) spherical singlet lenses. Unlike traditional designs that require separate collimation and refocusing stages, our approach directly converges imaged light to the back focal plane using a single lens group. Our configuration corrects spherical aberrations and efficiently collects light to achieve diffraction-limited performance across a wide range of wavelengths while simplifying alignment and assembly. Using this approach, we design and construct an example objective lens that features a long front working distance of 61 mm and a clipped NA of 0.30 (limited by an aperture in our experimental setup). We experimentally verify that it achieves monochromatic diffraction-limited resolution at wavelengths from 375 nm to 866 nm without requiring replacement of the lenses or changing the inter-lens spacings, and its performance remains robust across a 46 mm range variation in total length (by adjusting mainly the back working distance). Additionally, we develop a quantitative method to measure the field of view (FOV) using an experimentally calibrated pinhole target. Under 397 nm illumination (i.e., from 40 Ca + ion fluorescence), the objective achieves a resolution of 0.87 μm with a 540 μm FOV. This robust, all-COTS, and versatile design is well-suited for a broad range of experiments, supporting high-precision measurements and exploring quantum phenomena.

Cui, Jiafeng [Oak Ridge National Laboratory (ORNL)↗

Polyethylene-Reflected Arrays of HEU(93.2) Metal Units Separated by Vermiculite

This benchmark details the results of an experiment performed in the early 1970s as part of a series testing critical configurations in three dimensional arrays. For this experiment, cylinders of 93.2% enriched uranium metal were arranged in a 2x2x2 array inside of a polyethylene reflector. Layers of vermiculite of varying heights were surrounding each cylinder to achieve criticality variations. A total of four experimental configurations were tested by D.W. Magnuson, and detailed in his experimental report “Critical Three-Dimensional Arrays of Neutron Interacting Units: Part IV. Arrays of U(93.2) Metal Reflected by Concrete and Arrays Separated by Vermiculite and Reflected by Polyethylene.” The benchmark HEU-MET-FAST054 is closely related; the results of both experiments are discussed in the same report (Ref. 1) Closely related work has been recorded in HEU-MET-FAST-053, which is a benchmark evaluation of a different series of three dimensional array experiments with four different moderator materials. HEU-MET-FAST-023 and HEU-MET-FAST-026 are also related because they utilize the same metal cylinders as these experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Advanced Manufacturing Methods for Warm White LEDs for General Lighting

GE Lighting Solutions will develop precise and efficient manufacturing techniques for the “remote phosphor” platform of warm-white LED products. In volume, this will be demonstrated to drive significant materials, labor and capital productivity to achieve a maximum possible 53% reduction in overall cost. In addition, the typical total color variation for these white LEDs in production will be well within the ANSI bins and as low as a 4-step MacAdam ellipse centered on the black body curve. Achievement of both of these objectives will be demonstrated while meeting a performance target of > 75 lm/W for a warm-white LED and a reliability target of <30% lumen drop / <2-step MacAdam ellipse shift, estimated over 50,000 hrs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sound Assisted Low Temperature Spalling: Upscaling and Throughput

In evaluating the state-of-the-art spalling techniques, the key factor that is missing is the control of crack propagation, which is responsible for low quality wafers due to high surface roughness and Total Thickness Variation, TTV. This project has shown that acoustic waves can alter the conditions at the crack tip during thermal spalling, modifying the propagation speed and the stress field around it (stress intensity factor, K). Both factors are directly related to the roughness of the spalled surface, so as we control speed and stress, we can fine-tune the surface roughness through the entire wafer as suggested by Arakawa.

42 ENGINEERING↗