Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Molecular Accumulation during JWST’s Optical Telescope Cryogenic Thermal Vacuum Testing

Maintaining molecular cleanliness during the JWST’s Optical Telescope/Instrument Module (OTIS) Cryogenic Thermal Vacuum (TV) test campaign was critical to the success of its optical mission on orbit. In the thermal vacuum tests leading up to the final cryogenic test to validate the OTIS flight hardware, NASA Johnson Space Center’s (JSC’s) TV Chamber A was fully characterized for molecular contamination. It was found to contain common volatile condensable materials (VCM), including hydrocarbons, plasticizers, and silicones, all of which absorb in JWST’s infrared wavelength region. Due to the risks involved, cleaning molecular contamination from the OTIS mirrors was not an option and heating the Primary Mirror (PM) segments would have also been a risky and expensive endeavor. As a result, a monitoring process was developed and implemented during four different Pathfinder or risk reduction tests that were scheduled to occur prior to the flight hardware test. The goal was to quantify and assess the risk of molecular contamination depositing on the PM resulting from relatively warm chamber shrouds “leading” colder PM mirrors during warmup, by a margin of 10-50 Kelvin (K). This was accomplished using Cryogenic Quartz Crystal Microbalances (CQCMs), held at temperatures slightly cooler than the segments to signal the onset of contamination events. Per the JWST Contamination Control Plan (CCP)1, the total Primary Mirror molecular allocation requirement was 50 angstroms. In all tests, the results showed an average accumulated molecular contamination of <10 angstroms.

optics↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-Temperature Tanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellant is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of the effect of spacecraft propellant system parameters on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the general thermodynamic principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran implementation. Comparisons between the model results and test data are discussed, as well as sensitivity of the condensation rate to various parameters.

Anson Koch↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-Temperature Tanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellants is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of a proposed model for a propellant liquefaction system, and the effect of tank wall temperatures on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the heat transfer principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran algorithm implementation. The sensitivity of the condensation rate relative to varying tank wall temperatures is also discussed.

Anson Koch↗

Cryogenic High Accuracy Refraction Measurements Capabilities and New FUV Coating Mirror Technology Developments

This talk will emphasize the basic principles of refractive materials used in an optical telescope. In particular, the presentation will describe refractive index measurements that were performed for one of the instruments on the James Webb Space Telescope (JWST). A refractive system design was implemented in the Near-Infrared Camera (NIRCam) which is one of the main instruments on the JWST observatory. This camera was designed to make observations in the infrared part of the optical spectrum, and it is required to operate in a space environment at temperatures as low as 25K. Therefore, it was imperative to know the refractive index at those low cryogenic temperatures for the various glass substrates (ZnSe, LiF and BaF2) used in the system design of NIRCam. These cryogenic index of refraction measurements were carried out by using the world-class refractometer called the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility that was designed and built at the Goddard Space Flight Center (GSFC) in Greenbelt, MD. In the second part, there will be a discussion of the recent advances on the research and development activities of advanced and new mirror coating technologies that provide high reflectance performance in the far-ultraviolet (FUV) part of the optical spectrum. These new mirror coatings are envisioned for use on the reflecting mirrors of the next mission (beyond JWST) that will focus on astronomical observations in the FUV spectral range to deliver new and exciting discoveries about the origin of the cosmos.

Astronomy↗

Overview and Status of EXCLAIM, the Experiment for Cryogenic Large-Aperture Intensity Mapping

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne far-infrared telescope that will survey star formation history over cosmological time scales to improve our un-derstanding of why the star formation rate declined at redshiftz <2, despite continued clustering of darkmatter. Specifically, EXCLAIM will map the emission of redshifted carbon monoxide and singly ionized carbon lines in windows over a redshift range0< z <3.5, following an innovative approach known asintensity mapping. Intensity mapping measures the statistics of brightness fluctuations of cumulative lineemissions, as opposed to detecting individual galaxies, thus enabling a blind, complete census of the emittinggas. To detect this emission unambiguously, EXCLAIM will cross-correlate with a rich spectroscopic galaxycatalog. The EXCLAIM mission will use a cryogenic design to cool the telescope optics to approximately1.7K. The telescope will feature a90-cm primary mirror to probe spatial scales on the sky from the linearregime up to shot-noise-dominated scales. The telescope optical elements will couple to six μ-Spec spectrom-eter modules, operating over a420–540-GHz frequency band with a spectral resolution of512and featuringMicrowave Kinetic Inductance Detectors (MKIDs). In the baseline design, the detectors will be read out witha Radio Frequency System-on-Chip (RFSoC). The cryogenic telescope and the sensitive detectors will allowEXCLAIM to reach high sensitivity in spectral windows of low emission in the upper atmosphere. Here, anoverview of the mission design and development status since the start of the EXCLAIM project in early 2019 is presented.

Giuseppe Cataldo↗

Capability Improvements at Marshall Space Flight Center's X-Ray and Cryogenic Facility

The X-Ray & Cryogenic Facility (XRCF) at Marshall Space Flight Center is the world’s largest x-ray optic calibration facility and NASA’s premier cryogenic optical test facility. Built specifically to calibrate the Chandra telescope, the facility contributed to several other x-ray missions until 2005 when it became dedicated to normal incidence optical testing at cryogenic temperatures. Recently the facility’s x-ray test capability has been returned to service and updated. New beam monitors, focal plane detectors, and test article and instrument positioning systems have been added. The x-ray data acquisition system has been updated. A real-time position monitoring metrology system is being developed that will enable calibration of large diameter optics via partial illumination in a diverging beam. The newly expanded x-ray test capabilities of the facility will be discussed.

XRCF↗

Self-Aligned Focusing Schlieren at the 0.3-M Transonic Cryogenic Tunnel and the National Transonic Facility

The implementation of a self-aligned focusing schlieren (SAFS) system at two cryogenic wind tunnels at NASA Langley Research Center is discussed. Risk-reduction testing of the SAFS system was first performed at the 0.3-M Transonic Cryogenic Tunnel to evaluate the system’s operation in a small-scale characteristic cryogenic facility. Testing was conducted with three models: a three-quarter span 25.4-mm-diameter cylinder, a semi-span 65A006 tapered unswept airfoil, and a full-span SC(3)-0712 airfoil. Testing with the cylinder and semi-span airfoil revealed a highly dynamic shock environment, whereas the shock on the full-span airfoil was stationary, solidifying the usage of this model for a pre-/post-shock particle tracking velocimetry measurement. Temperature-induced polarization-altering window stresses were encountered during low-temperature testing, and were mitigated using a “non-ideal” quartz/quartz Rochon prism that had largely been neglected since the SAFS system’s first introduction in favor of the more favorable “ideal” glass/quartz Rochon prism. The size of the SAFS system was then decreased in order to fit inside an environmentally-controlled camera can enclosure at the National Transonic Facility (NTF) for testing of a sting-mounted aircraft model. The SAFS system was demonstrated to be effective at filtering out the large density gradient flow in the 0.3-M plenum, and the thick, high density turbulent boundary layers on the wind tunnel walls at the NTF. Results of the testing campaigns and improvements to future systems are discussed.

Joshua M. Weisberger↗

Validation of a Computational Fluid Dynamics Model of Axial Jet Mixing for Cryogenic Propellant Tank Pressure Control

The Fluid Dynamics Branch at the NASA Marshall Space Flight Center is preparing to support flight programs through analysis of a variety of cryogenic fluid management (CFM) applications. Many vehicles being considered for future manned missions to the moon and beyond use chemical or nuclear thermal propulsion systems that rely on cryogenic propellants. Storing cryogenic propellants for later use is a challenge, though. Many areas of active CFM research, testing, and design involve propellant conditioning to ensure propellant remains a usable liquid for propulsion. Multiple technologies may be used to achieve adequate conditioning including the subject of this paper, a jet-based mixer. Mixing serves to homogenize fluid temperatures and decrease ullage pressure. Development and validation of a modeling methodology for jet-based mixing was conducted to prepare for in-line design work.

Jacob M Brodnick↗

Self-Aligned Focusing Schlieren at the 0.3-M Transonic Cryogenic Tunnel and the National Transonic Facility

The implementation of a self-aligned focusing schlieren (SAFS) system at two cryogenic wind tunnels at NASA Langley Research Center is discussed. Risk-reduction testing of the SAFS system was first performed at the 0.3-M Transonic Cryogenic Tunnel to evaluate the system’s operation in a small-scale characteristic cryogenic facility. Testing was conducted with three models: a three-quarter span 25.4-mm-diameter cylinder, a semi-span 65A006 tapered unswept airfoil, and a full-span SC(3)-0712 airfoil. Testing with the cylinder and semi-span airfoil revealed a highly dynamic shock environment, whereas the shock on the full-span airfoil was stationary, solidifying the usage of this model for a pre-/post-shock particle tracking velocimetry measurement. Temperature-induced polarization-altering window stresses were encountered during low-temperature testing and were mitigated using a “non-ideal” quartz/quartz Rochon prism that had largely been neglected since the SAFS system’s first introduction in favor of the more favorable “ideal” glass/quartz Rochon prism. The size of the SAFS system was then decreased in order to fit inside an environmentally controlled camera can enclosure at the National Transonic Facility (NTF) for testing of a sting-mounted aircraft model. The SAFS system was demonstrated to be effective at filtering out the large density gradient flow in the0.3-M plenum, and the thick, high density turbulent boundary layers on the wind tunnel walls at the NTF. Results of the testing campaigns and improvements to future systems are discussed.

Joshua M Weisberger↗

Validation of a Computational Fluid Dynamics Model of Axial Jet Mixing for Cryogenic Propellant Tank Pressure Control

The Fluid Dynamics Branch at the NASA Marshall Space Flight Center is preparing to support flight programs through analysis of a variety of cryogenic fluid management (CFM) applications. Many vehicles being considered for future manned missions to the moon and beyond use chemical or nuclear thermal propulsion systems that rely on cryogenic propellants. Storing cryogenic propellants for later use is a challenge, though. Many areas of active CFM research, testing, and design involve propellant conditioning to ensure propellant remains a usable liquid for propulsion. Multiple technologies may be used to achieve adequate conditioning including the subject of this paper, a jet-based mixer. Mixing serves to homogenize fluid temperatures and decrease ullage pressure. Development and validation of a modeling methodology for jet-based mixing was conducted to prepare for in-line design work.

Jacob M. Brodnick↗

Cryogenic Extension of NASA Species Polynomials Using Hydrogen and Oxygen at Stoichiometry

The Helmholtz free energy for a mixture has been used in many chemistry and combustion studies for mixtures. An approach is described where polynomial fits intended for a thermally perfect ideal gases can be modified and implemented into a Helmholtz free energy model, such as those used by NIST in their REFPROP program. However, the limitation of the polynomial fits must be respected and should only used in a valid temperature interval where the flow field can be treated as a thermally perfect ideal gas when these species are present. This approach can allow a CFD simulation to have cryogenic regions of a flow field where high fidelity cryogenic species models are needed and allows for the use of species in other areas at higher temperatures where combustion species do not have such a model available or is not needed. Presented in the paper are CFD 1D detonation wave and species mass fraction simulation results which have cryogenic upstream conditions of Hydrogen and Oxygen at stoichiometry.

Combustion↗

Aluminum to Stainless-Steel Joints for Cryogenic Applications

Aluminum to stainless-steel joints are necessary for cryogenic applications such as cryogenic fluid management and combustion devices. Supplemental development in this area was required for a test program at NASA Marshall Space Flight Center (MSFC) of an Al6061-RAM2 additively manufacturing liquid rocket nozzle. The test program identified a risk for installing stainless-steel fluid fittings to aluminum manifolds. To address this, a literature search was completed for various joint designs, and three designs were down selected to be cryogenic pressure cycle tested at MSFC. The test pieces were subsequently burst tested with ambient temperature water. This paper provides an overview of the literature review, down selected designs, test setup, test results, and fractography. The test results informed design decisions for the Al6061-RAM2 nozzle, and the recommended design proved to be a robust option with no notable issues identified during hot-fire testing.

Tessa M. Fedotowsky↗

Superfluid-Tight Cryogenic Receiver With Continuous Sub-Kelvin Cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 – 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to ≈ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a 4He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

continuous adiabatic demagnetization refrigerator↗

Cryogenic Propellant Tank Drain Simulation with a Stratified Ullage Nodal Model

Cryogenic propellant tank pressurization systems maintain tank pressure within specified limits to comply with propellant thermodynamic and tank structural design requirements. Many pump-fed cryogenic liquid propulsion systems control tank pressure using an autogenous pressurization system. Autogenous pressurization systems vaporize and heat propellant to produce the pressurant gas delivered to the tank. While autogenous pressurization systems eliminate the need for a separate pressurant gas storage and delivery system, they couple pressurant mass requirements to propellant mass requirements. Accurate prediction of autogenous pressurant mass during propellant drain is essential in optimizing cryogenic propellant tank designs.

Richard G Hibbs↗

Investigating Dual Electrospinning as a Means of Enhancing Passive Thermal Control Coatings for Cryogenic Propellant Storage in Extraterrestrial Environments

Passive thermal control is necessary as space exploration becomes increasingly widespread. Materials with superior optical properties (high solar reflectance and infrared emittance) are critical for passive thermal control because they can reject most of the incident solar radiation and promote thermal emission from cryogenic propellant storage tanks, enabling the extraterrestrial storage of cryogens. We have demonstrated in previous studies that electrospun nanofibers exhibit exceptional optical properties, offering significant benefits for passive radiative cooling in space. Particularly, electrospun polyvinylidene fluoride-co-hexafluoropropylene PVDF-HFP nanofibers demonstrate exceptionally high solar reflectance (>99%) and strong thermal emittance (measured at ~300 K). However, they exhibit nanostructural changes in the presence of atomic oxygen, which is prevalent in Low Earth Orbit. This study focuses on creating a unique blend of polymeric (PVDF-HFP) and ceramic-based (silica) nanofibers by leveraging the chemical stability and atomic oxygen resistance of silica, using the dual electrospinning manufacturing method. This approach aims to preserve the structural properties of the polymeric counterpart without compromising its optical performance, thereby providing an innovative method for manufacturing environmentally resilient passive thermal control nanofibers with desirable optical and thermal control functionalities for extraterrestrial storage of cryogenic propellants.

Chieloka Ibekwe↗

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil↗