ITER LIDAR performance analysis

The core LIDAR Thomson scattering for ITER is specified for core profile measurements with a spatial resolution of 7 cm (a/30) for the range of 500 eV<T{sub e}<40 keV and n{sub e}>3x10{sup 19} m{sup -3} at an accuracy of <10% for T{sub e}. These specifications are verified using a full profile Monte Carlo simulation code. In the simulations it is assumed that the input transmission is 50% and the collection transmission is 10% for {lambda}=300-1200 nm and F/=6-17. A crucial design decision lies on the choice of laser and detector combination. It is evaluated that the system can meet its spatial and accuracy specifications for higher temperatures of T{sub e}>5 keV with a combination of a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser ({lambda}{sub 0}=1064 nm, {delta}{lambda}<1 nm, 5 J, and {delta}t{sub FWHM}=250 ps, 5-10 Hz) and S20, GaAs, and GaAsP microchannel plate photomultipliers ({delta}t{sub FWHM}<300 ps, effective quantum efficiency, EQE=3%-4%, and D=18 mm). In order to reach the required T{sub e} of 500 eV with Nd:YAG first harmonic, this choice requires a development of fast near infrared detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic Collision Experiments with Ultra-Low-Energy Antiprotons

We have developed techniques to decelerate, cool and confine antiprotons in vacuo with an electromagnetic trap, for production of a Monoenergetic Ultra-Slow Antiproton Source for High-precision Investigation (MUSASHI) over the last several years. The ultra-slow antiproton beam which can now be extracted stably has opened up the possibility to study ionization and atomic capture processes between an antiproton and an atom at an unprecedented low energy under the single-collision condition for the first time. The collision energy can be tuned from 10 eV to 1 keV either by varying the beam transport energy or by biasing the voltages at the collision region.Since the number of available antiprotons is very much limited, the reaction probability must be maximized in order to make best use of them. We have prepared a powerful supersonic helium gas jet with a density of 3x10{sup 12} atoms/cm{sup 3} to be crossed with the antiproton beam. For rigorous identification of particles (e{sup -}, p-bar and (p-barA{sup +}){sup 0}) needed for reduction of huge background signals, we developed a detection system with two microchannel plates each with a delay-line two-dimensional position sensitive detector, and a box of scintillator plates. A set of electrodes and coils were placed near the collision point to guide electromagnetically the electrons perpendicular to the antiproton beam. The reaction events will be recognized by an electron signal followed by an antiproton annihilation with an appropriate time of flight. Our design and strategy of the experiment are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

OZSPEC-2: An improved broadband high-resolution elliptical crystal x-ray spectrometer for high-energy density physics experiments (invited)

A novel time, space, and energy-resolved x-ray spectrometer has been developed which produces, in a single snapshot, a broadband and relatively calibrated spectrum of the x-ray emission from a high-energy density laboratory plasma. The opacity zipper spectrometer (OZSPEC-1) records a nearly continuous spectrum for x-ray energies from 240 to 5800 eV in a single shot. The second-generation OZSPEC-2, detailed in this work, records fully continuous spectra on a single shot from any two of these three bands: 270-650, 660-1580, and 1960-4720 eV. These instruments thus record thermal and line radiation from a wide range of plasmas. These instruments' single-shot bandwidth is unmatched in a time-gated spectrometer; conversely, other broadband instruments are either time-integrated (using crystals or gratings), lack spectral resolution (diode arrays), or cover a lower energy band (gratings). The OZSPECs are based on the zipper detector, a large-format (100x35 mm) gated microchannel plate detector, with spectra dispersed along the 100 mm dimension. OZSPEC-1 and -2 both use elliptically bent crystals of OHM, RAP, and/or PET. Individual spectra are gated in 100 ps. OZSPEC-2 provides one-dimensional spatial imaging with 30-50 {mu}m resolution over a 1500 {mu}m field of view at the source. The elliptical crystal design yields broad spectral coverage with resolution E/{delta}E>500, strong rejection of hard x-ray backgrounds, and negligible source broadening for extended sources. Near-term applications include plasma opacity measurements, detailed spectra of inertial fusion Hohlraums, and laboratory astrophysics experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion spectrometer composed of time-of-flight and Thomson parabola spectrometers for simultaneous characterization of laser-driven ions

An ion spectrometer, composed of a time-of-flight spectrometer (TOFS) and a Thomson parabola spectrometer (TPS), has been developed to measure energy spectra and to analyze species of laser-driven ions. Two spectrometers can be operated simultaneously, thereby facilitate to compare the independently measured data and to combine advantages of each spectrometer. Real-time and shot-to-shot characterizations have been possible with the TOFS, and species of ions can be analyzed with the TPS. The two spectrometers show very good agreement of maximum proton energy even for a single laser shot. The composite ion spectrometer can provide two complementary spectra measured by TOFS with a large solid angle and TPS with a small one for the same ion source, which are useful to estimate precise total ion number and to investigate fine structure of energy spectrum at high energy depending on the detection position and solid angle. Advantage and comparison to other online measurement system, such as the TPS equipped with microchannel plate, are discussed in terms of overlay of ion species, high-repetition rate operation, detection solid angle, and detector characteristics of imaging plate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultraviolet photodissociation of C{sub 2}F{sub 5}I with a small and simple photofragment translational spectrometer

Photodissociation dynamics of C{sub 2}F{sub 5}I near 280 and 304 nm has been investigated on a small and simple time-of-flight photofragment translational spectrometer (PTS). On this new PTS, the photolyzed and ionized fragments, not accelerated by electric field, travel freely for a short flight path (<50 mm) and are detected by microchannel plates. In the spectra of the I*({sup 2}P{sub 1/2}) channel at 281.73 and 304.02 nm, vibrational peaks with spacing of {approx}350 cm{sup -1} are partially resolved, indicating the preferential excitation of CF{sub 2} wag mode ({nu}{sub 11}=366 cm{sup -1}) of C{sub 2}F{sub 5} photofragment. The fraction of the available energy disposed into the internal energy is higher than 50% for both I{sup *} channel and I channel, showing the high excitation of vibration in the C{sub 2}F{sub 5} fragments. The fragment recoil anisotropy parameter {beta}(I{sup *}), determined to be 1.70 at 281.73 nm and 1.64 at 304.02 nm, reveals that I* atoms are produced predominantly from the parallel {sup 3}Q{sub 0}<-N transition. The anisotropy parameter {beta}(I), determined to be 1.25 at 279.71 nm and 0.88 at 304.67 nm, implies that I atoms are produced from two excited states, i.e., direct dissociation via the perpendicular {sup 3}Q{sub 1}(leftarrow)N transition, and indirect dissociation via the parallel {sup 3}Q{sub 0}(leftarrow)N transition then curve crossing to the {sup 1}Q{sub 1} potential energy surface. Analysis on the recent studies with vibrational state resolution in the photodissociation of alkyl iodides in the A band reveals that the ''symmetric bending'' mode on {alpha}-carbon of alkyl iodides is the preferential vibrational excitation mode, which can be explained by the classic impulsive model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A short pulse (7 {mu}s FWHM) and high repetition rate (dc-5kHz) cantilever piezovalve for pulsed atomic and molecular beams

In this paper we report on the design and operation of a novel piezovalve for the production of short pulsed atomic or molecular beams. The high speed valve operates on the principle of a cantilever piezo. The only moving part, besides the cantilever piezo itself, is a very small O-ring that forms the vacuum seal. The valve can operate continuous (dc) and in pulsed mode with the same drive electronics. Pulsed operation has been tested at repetition frequencies up to 5 kHz. The static deflection of the cantilever, as mounted in the valve body, was measured as a function of driving field strength with a confocal microscope. The deflection and high speed dynamical response of the cantilever can be easily changed and optimized for a particular nozzle diameter or repetition rate by a simple adjustment of the free cantilever length. Pulsed molecular beams with a full width at half maximum pulse width as low as 7 {mu}s have been measured at a position 10 cm downstream of the nozzle exit. This represents a gas pulse with a length of only 10 mm making it well matched to for instance experiments using laser beams. Such a short pulse with 6 bar backing pressure behind a 150 {mu}m nozzle releases about 10{sup 16} particles/pulse and the beam brightness was estimated to be 4x10{sup 22} particles/(s str). The short pulses of the cantilever piezovalve result in a much reduced gas load in the vacuum system. We demonstrate operation of the pulsed valve with skimmer in a single vacuum chamber pumped by a 520 l/s turbomolecular pump maintaining a pressure of 5x10{sup -6} Torr, which is an excellent vacuum to have the strong and cold skimmed molecular beam interact with laser beams only 10 cm downstream of the nozzle to do velocity map slice imaging with a microchannel-plate imaging detector in a single chamber. The piezovalve produces cold and narrow ({Delta}v/v=2%-3%) velocity distributions of molecules seeded in helium or neon at modest backing pressures of only 6 bar. The low gas load of the cantilever valve makes it possible to design very compact single chamber molecular beam machines with high quality cold and intense supersonic beams. The high speed cantilever piezovalve may find broad applicability in experiments where short and strong gas pulses are needed with only modest pumping, the effective use of (expensive) samples, or the production of cold atomic and molecular beams.

43 PARTICLE ACCELERATORS↗

Observation of pulsed x-ray trains produced by laser-electron Compton scatterings

X-ray generation based on laser-electron Compton scattering is one attractive method to achieve a compact laboratory-sized high-brightness x-ray source. We have designed, built, and tested such a source; it combines a 50 MeV multibunch electron linac with a mode-locked 1064 nm laser stored and amplified in a Fabry-Perot optical cavity. We directly observed trains of pulsed x rays using a microchannel plate detector; the resultant yield was found to be 1.2x10{sup 5} Hz in good agreement with prediction. We believe that the result has demonstrated good feasibility of linac-based compact x-ray sources via laser-electron Compton scatterings.

43 PARTICLE ACCELERATORS↗

Time of flight elastic recoil detection analysis with a position sensitive detector

A position sensitive detection system based on the microchannel plate detector has been constructed and installed at the existing time of flight (TOF) spectrometer in order to perform a kinematic correction and improve the surface time/depth resolution of elastic recoil detection analysis (ERDA) system. The position resolution of the detector has been tested for different types of ions and anode voltages. TOF spectra of recoiled O ions from SiO{sub 2} and F from CaF{sub 2} were collected in coincidence with position sensitive detector signal. Kinematic correction of TOF spectra improved surface time/depth resolution by {approx}20% for our system; however even higher improvements could be obtained in larger solid angle TOF-ERDA systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma production by means of discharge in a spherical cavity

The work is devoted to the study of plasma, appearing as a result of cumulation of shock wave with form close to spherical. The shock wave was obtained by triggering of fast discharge (dI/dt about 10{sup 12} A/s) on inner surface of cavity, made from insulator. Spherical cavity with radius 4.5 mm was filled with Ar at 80 Pa. Inductive storage with semiconductive opening switch was used as a current driver. Spherical plasma with diameter about 1 mm, emitting in vacuum ultraviolet (vuv), was detected by means of pinhole measurements with time gated microchannel plate camera, starting about 50 ns from the beginning of the discharge. vuv spectra have shown the presence spectral lines of ArV-ArVIII ions, which gives the estimation of electron temperature as 30 eV. The plasma ball reveals no instabilities, keeps its characteristics and emits vuv radiation during 300 ns. After 600 ns from the beginning of the discharge plasma emits a flux of electrons with energies about 1 keV with temporal structure about 100 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and characterization of sub-100 ps photomultiplier tubes

We describe the evaluation of a microchannel plate (MCP) photomultiplier tube (PMT), incorporating a 3 {mu}m pore MCP and constant voltage anode and cathode gaps. The use of the small pore size results in PMTs with response functions of the order of 85 ps full-width-half-maximum, while the constant electric field across the anode and cathode gaps produces a uniform response function over the entire operating range of the device. The PMT was characterized on a number of facilities and employed on gas Cherenkov detectors fielded on various deuterium tritium fuel (DT) implosions on the Omega Laser Facility at the University of Rochester. The Cherenkov detectors are part of diagnostic development to measure Gamma ray reaction history for DT implosions on the National Ignition Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of neutron induced background noise on gated x-ray framing cameras

A temporally gated x-ray framing camera based on a proximity focus microchannel plate is one of the most important diagnostic tools of inertial confinement fusion experiments. However, fusion neutrons produced in imploded capsules interact with structures surrounding the camera and produce background to x-ray signals. To understand the mechanisms of this neutron induced background, we tested several gated x-ray cameras in the presence of 14 MeV neutrons produced at the Omega laser facility. Differences between background levels observed with photographic film readout and charge-coupled-device readout have been studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse-dilation enhanced gated optical imager with 5 ps resolution (invited)

A 5 ps gated framing camera was demonstrated using the pulse-dilation of a drifting electron signal. The pulse-dilation is achieved by accelerating a photoelectron derived information pulse with a time varying potential [R. D. Prosser, J. Phys. E 9, 57 (1976)]. The temporal dependence of the accelerating potential causes a birth time dependent axial velocity dispersion that spreads the pulse as it transits a drift region. The expanded pulse is then imaged with a conventional gated microchannel plate based framing camera and the effective gating time of the combined instrument is reduced over that of the framing camera alone. In the drift region, electron image defocusing in the transverse or image plane is prevented with a large axial magnetic field. Details of the unique issues associated with rf excited photocathodes were investigated numerically and a prototype instrument based on this principle was recently constructed. Temporal resolution of the instrument was measured with a frequency tripled femtosecond laser operating at 266 nm. The system demonstrated 20x temporal magnification and the results are presented here. X-ray image formation strategies and photometric calculations for inertial confinement fusion implosion experiments are also examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum ultraviolet impurity spectroscopy on the Alcator C-Mod tokamak

Vacuum ultraviolet spectroscopy is used on the Alcator C-Mod tokamak to study the physics of impurity transport and provide feedback on impurity levels to assist experimental operations. Sputtering from C-Mod's all metal (Mo+W) plasma facing components and ion cyclotron range of frequency antenna and vessel structures (sources for Ti, Fe, Cu, and Ni), the use of boronization for plasma surface conditioning and Ar, Ne, or N{sub 2} gas seeding combine to provide a wealth of spectroscopic data from low-Z to high-Z. Recently, a laser blow-off impurity injector has been added, employing CaF{sub 2} to study core and edge impurity transport. One of the primary tools used to monitor the impurities is a 2.2 m Rowland circle spectrometer utilizing a Reticon array fiber coupled to a microchannel plate. With a 600 lines/mm grating the 80<{lambda}<1050 A range can be scanned, although only 40-100 A can be observed for a single discharge. Recently, a flat-field grating spectrometer was installed which utilizes a varied line spacing grating to image the spectrum to a soft x-ray sensitive Princeton Instruments charge-coupled device camera. Using a 2400 lines/mm grating, the 10<{lambda}<70 A range can be scanned with 5-6 nm observed for a single discharge. A variety of results from recent experiments are shown that highlight the capability to track a wide range of impurities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental setup for laser spectroscopy of molecules in a high magnetic field

An experimental setup to measure the effects of a high magnetic field on the structure and decay dynamics of molecules is designed and constructed. A vacuum chamber is mounted in the bore of a superconducting magnet. A molecular beam passes in the chamber. Pulsed laser light excites the molecules in the field. The parent or fragment ions are extracted by an electric field parallel to the magnetic field. They are detected by a microchannel plate. Their mass and charge are determined by the time-of-flight method. The performance of the setup was examined using resonance-enhanced two-photon ionization through the X{sup 2} {Pi}-A{sup 2}{Sigma}{sup +} transition of nitric oxide (NO) molecules. The ions were detected with sufficient mass resolution to discriminate the species in a field of up to 10 T. This is the first experiment to succeed in the mass-selective detection of ions by the time-of-flight method in a high magnetic field. By measuring NO{sup +} ion current as a function of the laser frequency, the X{sup 2}{Pi}-A{sup 2} {Sigma}{sup +} rotational transition lines, separated clearly from the background noise, were observed in fields of up to 10 T. From the relative strengths of the transition lines, the ion detection efficiency was determined as a function of the magnetic field strength. This setup was shown to be applicable in a field higher than 10 T. The Landau levels of molecules were successfully observed to demonstrate the setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional space resolving flat-field holographic grating soft x-ray framing camera spectrograph for laser plasma diagnostics

A 1D space resolving x-ray spectrum diagnostic system has been developed to study the radiation opacity of hot plasma on SG-II laser facility. The diagnostic system consists of a 2400 lines/mm flat-field holographic grating and a gated microchannel plate coupled with an optical CCD and covers the wavelength range of 5-50 A. The holographic grating was compared with a ruled one by measuring the emission spectra from a laser-produced molybdenum plasma. The results indicate that the holographic grating possesses better sensitivity than the ruled grating having nearly similar spectral resolution. The spectrograph has been used in radiative opacity measurement of Fe plasma. Simultaneous measurements of the backlight source and the transmission spectrum in appointed time range in one shot have been accomplished successfully with the holographic grating spectrometer. The 2p-3d transition absorption of Fe plasma near 15.5A in has been observed clearly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of sensitivity in high-resolution Rutherford backscattering spectroscopy

The sensitivity (limit of detection) of high-resolution Rutherford backscattering spectroscopy (HRBS) is mainly determined by the background noise of the spectrometer. There are two major origins of the background noise in HRBS, one is the stray ions scattered from the inner wall of the vacuum chamber of the spectrometer and the other is the dark noise of the microchannel plate (MCP) detector which is commonly used as a focal plane detector of the spectrometer in HRBS. In order to reject the stray ions, several barriers are installed inside the spectrometer and a thin Mylar foil is mounted in front of the detector. The dark noise of the MCP detector is rejected by the coincidence measurement with the secondary electrons emitted from the Mylar foil upon the ion passage. After these improvements, the background noise is reduced by a factor of 200 at a maximum. The detection limit can be improved down to 10 ppm for As in Si at a measurement time of 1 h under ideal conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grazing incidence extreme ultraviolet spectrometer fielded with time resolution in a hostile Z-pinch environment

This recently developed diagnostic was designed to allow for time-gated spectroscopic study of the EUV radiation (4 nm < {lambda} < 15 nm) present during harsh wire array z-pinch implosions. The spectrometer utilizes a 25 {mu}m slit, an array of 3 spherical blazed gratings at grazing incidence, and a microchannel plate (MCP) detector placed in an off-Rowland position. Each grating is positioned such that its diffracted radiation is cast over two of the six total independently timed frames of the MCP. The off-Rowland configuration allows for a much greater spectral density on the imaging plate but only focuses at one wavelength per grating. The focal wavelengths are chosen for their diagnostic significance. Testing was conducted at the Zebra pulsed-power generator (1 MA, 100 ns risetime) at University of Nevada, Reno on a series of wire array z-pinch loads. Within this harsh z-pinch environment, radiation yields routinely exceed 20 kJ in the EUV and soft x-ray. There are also strong mechanical shocks, high velocity debris, sudden vacuum changes during operation, energic ion beams, and hard x-ray radiation in excess of 50 keV. The spectra obtained from the precursor plasma of an Al double planar wire array contained lines of Al IX and AlX ions indicating a temperature near 60 eV during precursor formation. Detailed results will be presented showing the fielding specifications and the techniques used to extract important plasma parameters using this spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high speed photomultiplier tubes with nanosecond gating for fusion diagnostics

Fusion diagnostics can involve the measurement of ultra-fast optical pulses, often in close temporal proximity. We present a solution for the diagnostics of gamma reaction history and neutron time of flight by using microchannel plate based photomultiplier tubes (PMTs). The time response of the PMTs can be as fast as 100 ps FWHM and with a gain of up to 10{sup 7}. To observe small events in close temporal proximity to much larger signals such as the down-scattered fraction, the response of MCP-PMTs can be gated with an on/off ratio of up to 10{sup 13} in just 2 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗