Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile recognition of graphene layers from optical images under controlled illumination through green channel correlation method

In this study, a simple yet versatile method is proposed for identifying the number of exfoliated graphene layers transferred on an oxide substrate from optical images, utilizing a limited number of input images for training, paired with a more traditional number of a few thousand well-published Github images for testing and predicting. Two thresholding approaches, namely the standard deviation-based approach and the linear regression-based approach, were employed in this study. The method specifically leverages the red, green, and blue color channels of image pixels and creates a correlation between the green channel of the background and the green channel of the various layers of graphene. This method proves to be a feasible alternative to deep learning-based graphene recognition and traditional microscopic analysis. The proposed methodology performs well under conditions where the effect of surrounding light on the graphene-on-oxide sample is minimum and allows rapid identification of the various graphene layers. Here, the study additionally addresses the functionality of the proposed methodology with nonhomogeneous lighting conditions, showcasing successful prediction of graphene layers from images that are lower in quality compared to typically published in literature. In all, the proposed methodology opens up the possibility for the non-destructive identification of graphene layers from optical images by utilizing a new and versatile method that is quick, inexpensive, and works well with fewer images that are not necessarily of high quality.

36 MATERIALS SCIENCE↗

AstroPix4 — a novel HV-CMOS sensor developed for space based experiments

For the proposed space based gamma-ray observatory All-sky Medium-Energy Gamma-ray Observatory eXplorer (AMEGO-X), a silicon tracker based on a novel High Voltage-CMOS (HV-CMOS) sensor called AstroPix, is currently being developed. Preliminary measurements with the first full reticle prototype AstroPix3 show that the power target of 1.5 mW/cm 2 can currently not be reached due to the digital consumption of 3.08 mW/cm 2 , while the analog power consumption of 1.04 mW/cm 2 and a break down voltage of over 350 V look promising. Based on these results, the design changes in AstroPix4, submitted in May 2023, are presented, containing changes to the time stamp generation and readout architecture. A digital power consumption below 0.25 mW/cm 2 is expected by removing the fast 200 MHz clock used to measure the time-over-threshold (ToT) and an LVDS receiver. A maximum resolution of 3.125 ns for time-of-arrival (ToA) and ToT is reached by adding per-pixel Flash-Time-to-Digital Converter (TDCs) controlled by a global delay-locked loop (DLL).

47 OTHER INSTRUMENTATION↗

Variational autoencoders for at-source data reduction and anomaly detection in high energy particle detectors

Detectors in next-generation high-energy physics experiments face several daunting requirements, such as high data rates, damaging radiation exposure, and stringent constraints on power, space, and latency. To address these challenges, machine learning in readout electronics can be leveraged for smart detector designs, enabling intelligent inference and data reduction at-source. Variational autoencoders (VAEs) offer a variety of benefits for front-end readout; an on-sensor encoder can perform efficient lossy data compression while simultaneously providing a latent space representation that can be used for anomaly detection. Results are presented from low-latency and resource-efficient VAEs for front-end data processing in a futuristic silicon pixel detector. Encoder-based data compression is found to preserve good performance of off-detector analysis while significantly reducing the off-detector data rate as compared to a similarly sized data filtering approach. Furthermore, the latent space information is found to be a useful discriminator in the context of real-time sensor defect monitoring. Together, these results highlight the multifaceted utility of autoencoder-based front-end readout schemes and motivate their consideration in future detector designs.

47 OTHER INSTRUMENTATION↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Gamma-ray Spectra from a 3x3 CsPbBr 3 Array

CsPbBr 3 is a promising semiconductor material for X- and γ-ray detection at room temperature due to a wide bandgap of 2.3eV, high stopping power, and relatively high mobility-lifetime products of electrons and holes, and the capability of growing large crystals. In this paper we report on fabrication and testing of a 3.8 mm thick, 3 X 3 array with 1.2 mm pitch. Raw 137 Cs spectra were acquired with applied bias of 400 V, 500 V, and 600 V. Energy resolution of between 2 and 3 % FWHM at 662 keV was obtained from most pixels without any correction at room temperature. After 15 days under continuous bias at 600 V, no polarization effects were observed.

36 MATERIALS SCIENCE↗

CHESS 2025: Spectrometer orthorectified at-sensor radiance from NEON AOP imaging spectroscopy surveys

This dataset provides Level 1 (L1) orthorectified at-sensor radiance derived from measurements collected by the Imaging Spectrometer-1 (NIS-1) onboard the NEON (National Ecological Observatory Network) Airborne Observation Platform (AOP) for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). NIS-1 captures light reflected from the Earth’s surface in 426 discrete wavelength bands as raw digital numbers (DNs; Level 0). These data are then calibrated to physical units (uW/cm²·sr·nm) following the processing steps described in the NEON Imaging Spectrometer Level 1B Calibrated Radiance Algorithm Theoretical Basis Document (ATBD; Gallery 2022). The data delivered here are the primary inputs for the surface reflectance product in “Custom surface reflectance, shade masks, and equivalent water thickness maps for the Colorado Headwaters Ecological Spectroscopy Study” (Carroll et al. 2026). For intertemporal comparison, the radiance data here are most directly relatable to the v2 radiance data in “NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset” (Goulden et al. 2018), to which the same processing methodology was applied. Together, the radiance and reflectance data enable users to exploit the unique reflection signatures of different surface objects for land cover classification, foliar trait mapping, plant vigor assessment, water content estimation, trace-element identification, and other scientific applications. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. Within each domain, data are delivered by flightline as orthorectified and calibrated hyperspectral rasters in Hierarchical Data Format version 5 (HDF5) format, with radiance values provided in uW/cm²·sr·nm on a fixed, uniform Universal Transverse Mercator (UTM) grid at 1 meter spatial resolution. The radiance rasters include all 426 NIS-1 spectral bands, along with associated quality-assurance (QA) and diagnostic and ancillary layers needed for atmospheric correction workflows. Orthorectified radiance is produced from pushbroom spectrometer observations by applying NEON’s radiometric calibration (including bad pixel masking, dark subtract, dark pedestal shift correction, electronic panel ghost correction, grating ghost correction, deblur correction and flat-fielding) and spectral calibration (using spectral response function band centers and full-width at half-maximum intensity), followed by geolocation and regridding to the fixed grid. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Mitigation of the Brighter-Fatter Effect in the LSST Camera

Thick, fully depleted charge-coupled devices (CCDs) are known to exhibit non-linear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). This particularly impacts bright calibration stars, which appear larger than their intrinsic shape, creating a flux-dependent point-spread function (PSF) that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSST Camera before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new sampling method based on a physically motivated model to account these higher-order terms in the correction, and then we test the modified correction on both datasets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars which we conclude is the result of a unmodeled curl component of the deflection field by the correction. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

A New Concept for Kilotonne Scale Liquid Argon Time Projection Chambers

We develop a novel Time Projection Chamber (TPC) concept suitable for deployment in kilotonne-scale detectors, with a charge-readout system free from reconstruction ambiguities, and a robust TPC design that reduces high-voltage risks while increasing the coverage of the light-collection system and maximizing the active volume. This novel concept could be used as a far detector module in the Deep Underground Neutrino Experiment (DUNE). For the charge-readout system, we used the charge-collection pixels and associated application-specific integrated circuits currently being developed for the liquid argon (LAr) component of the DUNE Near Detector design, ArgonCube. In addition, we divided the TPC into a number of shorter drift volumes, reducing the total voltage used to drift the ionization electrons, and minimizing the stored energy per TPC. Segmenting the TPC also contains scintillation light, allowing for precise trigger localization and a more expansive light-readout system. Furthermore, the design opens the possibility of replacing or upgrading components. These augmentations could substantially improve the reliability and the sensitivity, particularly for low-energy signals, in comparison to traditional monolithic LArTPCs with projective-wire charge readouts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaporated Se x Te 1-x Thin Films with Tunable Bandgaps for Short-Wave Infrared Photodetectors

Semiconducting absorbers in high-performance short-wave infrared (SWIR) photodetectors and imaging sensor arrays are dominated by single-crystalline germanium and III-V semiconductors. However, these materials require complex growth and device fabrication procedures. In this work, thermally evaporated Se x Te 1- x alloy thin films with tunable bandgaps for the fabrication of high-performance SWIR photodetectors are reported. From absorption measurements, it is shown that the bandgaps of Se x Te 1- x films can be tuned continuously from 0.31 eV (Te) to 1.87 eV (Se). Owing to their tunable bandgaps, the peak responsivity position and photoresponse edge of Se x Te 1- x film-based photoconductors can be tuned in the SWIR regime. By using an optical cavity substrate consisting of Au/Al 2 O 3 to enhance its absorption near the bandgap edge, the Se 0.32 Te 0.68 film (an optical bandgap of ≈0.8 eV)-based photoconductor exhibits a cut-off wavelength at ≈1.7 μm and gives a responsivity of 1.5 AW -1 and implied detectivity of 6.5 × 10 10 cm Hz 1/2 W -1 at 1.55 μm at room temperature. Importantly, the nature of the thermal evaporation process enables the fabrication of Se 0.32 Te 0.68 -based 42 × 42 focal plane arrays with good pixel uniformity, demonstrating the potential of this unique material system used for infrared imaging sensor systems.

36 MATERIALS SCIENCE↗

Quasi‐2D Perovskite Crystalline Layers for Printable Direct Conversion X‐Ray Imaging

Abstract Polycrystalline perovskite film‐based X‐ray detector is an appealing technology for assembling large scale imager by printing methods. However, thick crystalline layer without trap and solvent residual is challenging to fabricate. Here, the authors report a solution method to produce high quality quasi‐2D perovskite crystalline layers and detectors that are suitable for X‐ray imaging. By introducing n ‐butylamine iodide into methylammonium lead iodide precursor and coating at elevated temperatures, compact and crystalline layers with exceptional uniformity are obtained on both rigid and flexible substrates. Photodiodes built with the quasi‐2D layers exhibit a low dark current and stable operation under constant electrical field over 96 h in dark, and over 15 h under X‐ray irradiation. The detector responds sensitively under X‐ray, delivering a high sensitivity of 1214 µC Gy air −1 cm −2 and a sensitivity gain is observed when operated under higher fields. Finally, high resolution images are demonstrated using a single pixel device that can resolve 80–200 µm features. This work paves the path for printable direct conversion X‐ray imager development.

36 MATERIALS SCIENCE↗

Universal Polarization Transformations: Spatial Programming of Polarization Scattering Matrices Using a Deep Learning‐Designed Diffractive Polarization Transformer

Abstract Controlled synthesis of optical fields having nonuniform polarization distributions presents a challenging task. Here, a universal polarization transformer is demonstrated that can synthesize a large set of arbitrarily‐selected, complex‐valued polarization scattering matrices between the polarization states at different positions within its input and output field‐of‐views (FOVs). This framework comprises 2D arrays of linear polarizers positioned between isotropic diffractive layers, each containing tens of thousands of diffractive features with optimizable transmission coefficients. After its deep learning‐based training, this diffractive polarization transformer can successfully implement N i N o = 10 000 different spatially‐encoded polarization scattering matrices with negligible error, where N i and N o represent the number of pixels in the input and output FOVs, respectively. This universal polarization transformation framework is experimentally validated in the terahertz spectrum by fabricating wire‐grid polarizers and integrating them with 3D‐printed diffractive layers to form a physical polarization transformer. Through this set‐up, an all‐optical polarization permutation operation of spatially‐varying polarization fields is demonstrated, and distinct spatially‐encoded polarization scattering matrices are simultaneously implemented between the input and output FOVs of a compact diffractive processor. This framework opens up new avenues for developing novel devices for universal polarization control and may find applications in, e.g., remote sensing, medical imaging, security, material inspection, and machine vision.

Optical neural networks↗

Wide‐Field Bond Quality Evaluation Using Frequency Domain Thermoreflectance with Deep Neural Network Feature Reconstruction

Heterogeneous integration of microelectronic components provides a pathway to improve circuit/component performance; however, this comes with assembly challenges, in particular due to complex interfaces via subsurface bump bonds. The ability of these bonds to transmit electrical signals and conduct heat to the carrier substrate limits component performance. In this work, hyperspectral frequency‐domain thermoreflectance (FDTR) imaging is demonstrated as a robust technique for evaluating the quality of subsurface indium bump bonds in a surrogate microelectronic sample. By performing microscale FDTR imaging with coarse motion image stitching, thermal phase maps that cover a 4 mm by 4 mm field‐of‐view with subsurface feature sensitivity at depths greater than 50 µm are obtained. The resulting FDTR hyperspectral data contains more than three million pixels and reveal the quality of subsurface microbump arrays. Wide‐field analysis of bonded versus gap regions is enabled by deep neural network feature reconstruction, that after training, rapidly provides an interpretable representation of bond quality. Utility of noisy higher frequency FDTR phase maps, i.e., near the computationally predicted sensing depth limit, results in an average prediction error of 11%. Taken together, FDTR with neural network‐based analysis demonstrates subsurface bond monitoring at length scales relevant for heterogeneously integrated microelectronics.

FDTR↗

Separating Physically Distinct Mechanisms in Complex Infrared Plasmonic Nanostructures via Machine Learning Enhanced Electron Energy Loss Spectroscopy

Electron energy loss spectroscopy (EELS) enables direct exploration of plasmonic phenomena at the nanometer level. To isolate individual plasmon modes, linear unmixing methods can be used to separate different physical mechanisms, but in larger and more complex systems the interpretability of the components becomes uncertain. Here, infrared plasmonic resonances in self-assembled heterogeneous monolayer films of doped-semiconductor nanoparticles are examined beyond linear unmixing techniques, and both supervised and unsupervised machine-learning-based analyses of hyperspectral EELS datasets are demonstrated. Additionally, in the supervised approach, a human operator labels a small number of pixels in the hyperspectral dataset corresponding to features of interest which are then propagated across the entire dataset. In the unsupervised approach, non-linear autoencoders are used to create a highly-reduced latent-space representation of the dataset, within which insight into the relevant physics can be gleaned from straightforward distance metrics that do not depend on operator input and bias. The advantage of these approaches is that the labeling separates physical mechanisms without altering the data, enabling robust analyses of the influence of heterogeneities in mesoscale complex systems.

36 MATERIALS SCIENCE↗

Lateral Confinement in 2D Nanoplatelets: A Strategy to Expand the Colloidal Quantum Engineering Toolbox

Among colloidal nanocrystals, 2D nanoplatelets offer a unique set of properties with exceptionally narrow luminescence and low lasing thresholds. Furthermore, their anisotropic shape expands the playground for the complex design of heterostructures where spectra but also scattering rates can be engineered. A challenge that still remains is to combine shell growth which makes NPLs stable, with spectral tunability. Indeed, most reported shelled nanoplatelets end up being red emitters due to a loss of quantum confinement. Here, the combination of both lateral and in-plane confinements within a single heterostructure is explored. A CdS/CdSe/CdS/CdZnS core–crown–crown shell structure that enables yellow emission is grown and that is responsive to a large range of excitation including visible photons, X-ray photons, electron beams, and electrical excitations. k.p simulations predict that emission tunability of up to several 100 s of meV can be obtained in ideal structures. This material also displays stimulated emission resulting from bi-exciton emission with a low threshold. Once integrated into an LED stack, this material is compatible with sub-bandgap excitation and exhibits high luminance. Scaling of the electroluminescence properties by downsizing the pixel size is also investigated.

2D materials↗

Helical Photonic Metamaterials for Encrypted Chiral Holograms

Helical structures are among the most quintessential three-dimensional (3D) forms that exhibit mirror asymmetry, a hallmark of chirality. Various structural parameters of helices directly linked to chiroptical properties highlight their importance as essential optical metamaterials for polarization-resolved sensors, imaging, and spectroscopies. However, such function-defining properties remain incompletely understood due to fabrication challenges and the lack of a relationship between structure and optical properties. Here, helical structures are analyzed parametrically, and correlations are established that are applicable to the design of chiral helical optical metamaterials. By systematically varying independent parameters—such as from single-turn to five-turn helices and from small major radii to larger ones optimized to fit the unit cell—the underlying relationships with ellipticty are revealed. In addition to theoretical modeling, the findings are experimentally validated using 3D printing and terahertz spectroscopy. The results demonstrate that optimized helical structures are mechanically tunable and exhibit unprecedented optical properties, including broadband and high-magnitude ellipticity spectra. Being embedded in soft elastomers, helical arrays can serve as soft, stretchable optical-mechanical sensors and holograms containing encoded information, such as barcodes and quick response (QR) codes. Chiral QR codes are realized using pixelated single helices with different handedness, demonstrating their potential as advanced encryption/decryption systems for security applications and chiral metaholograms.

Encrypted QR codes↗

Measuring binary fluidization of nonspherical and spherical particles using machine learning aided image processing

Abstract The binary fluidization of Geldart D type nonspherical wood particles and spherical low density polyethylene (LDPE) particles was investigated in a laboratory‐scale bed. The experiment was performed for varying static bed height, wood particles count, as well as superficial gas velocity. The LDPE velocity field were quantified using particle image velocimetry (PIV). The wood particles orientation and velocity are measured using particle tracking velocimetry (PTV). A machine learning pixel‐wise classification model was trained and applied to acquire wood and LDPE particle masks for PIV and PTV processing, respectively. The results show significant differences in the fluidization behavior between LDPE only case and binary fluidization case. The effects of wood particles on the slugging frequency, mean, and variation of bed height, and characteristics of the particle velocities/orientations were quantified and compared. This comprehensive experimental dataset serves as a benchmark for validating numerical models.

Li, Cheng↗

Deep Learning for Spectroscopic X-ray Nano-Imaging Denoising

Synchrotron transmission X-ray microscopy with absorption near edge structure (TXM-XANES) is a powerful tool for investigating the structure and composition of materials at nano- to meso-scales. It is, however, often challenged by high levels of noise that obscure critical details at the single-pixel level. To address this issue, a deep learning-based algorithm is developed for suppressing the image noise, grounded in self-supervised learning principles. In contrast to traditional image denoising methods, this approach successfully enhances the visibility of fine details while significantly reducing the noise in the X-ray images. Through this advancement, the potential of the approach for improving the accuracy and interpretability of the TXM-XANES data is demonstrated, thereby enabling more precise detection of nanoscale phenomena such as inhomogeneous cation redox and metal segregation in battery cathode materials. This technique offers an effective new avenue for harnessing the full potential of synchrotron TXM-XANES imaging, paving the way for a range of exciting new studies in materials science and beyond.

36 MATERIALS SCIENCE↗