At least 577 records · Page 32

Guest Editorial Introduction to the Special Issue on 'Advanced Signal Processing Techniques and Telecommunications Network Infrastructures for Smart Grid Analysis, Monitoring, and Management'

Electrical power systems are undergoing a radical change in structure, components, and operational paradigms, and are progressively approaching the new concept of smart grids (SGs). Future power distribution systems will be characterized by the simultaneous presence of various distributed resources, such as renewable energy systems (i.e., photovoltaic power plant and wind farms), storage systems, and controllable/non-controllable loads. Control and optimization architectures will enable network-wide coordination of these grid components in order to improve system efficiency and reliability and to limit greenhouse gas emissions. In this context, the energy flows will be bidirectional from large power plants to end users and vice versa; producers and consumers will continuously interact at different voltage levels to determine in advance the requests of loads and to adapt the production and demand for electricity flexibly and efficiently also taking into account the presence of storage systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characteristics of ultra low-k nanoporous and fluorinated silica based films prepared by plasma enhanced chemical vapor deposition

Low dielectric constant (low-k) silica based films were deposited on p-type silicon and polycarbonate substrates by radio frequency (RF) plasma enhanced chemical vapor deposition method at low temperature. A mixture of tetraethoxysilane vapor, oxygen, and tetrafluoromethane (CF{sub 4}) was used for the deposition of the films in forms of two structures called as SiO{sub x}C{sub y} and SiO{sub x}C{sub y}F{sub z}. Properties of the films were controlled by amount of porosity and fluorine content in the film matrix. The influence of RF power and CF{sub 4} flow on the elemental composition, deposition rate, surface roughness, leakage current, refractive index, and dielectric constant of the films were characterized. Moreover, optical emission spectroscopy was applied to monitor the plasma process at the different parameters. Electrical characteristics of SiO{sub x}C{sub y} and SiO{sub x}C{sub y}F{sub z} films with metal-oxide-semiconductor structure were investigated using current-voltage analysis to measure the leakage current and breakdown field, as well as capacitance-voltage analysis to obtain the film's dielectric constant. The results revealed that SiO{sub x}C{sub y} films, which are deposited at lower RF power produce more leakage current, meanwhile the dielectric constant and refractive index of these films decreased mainly due to the more porosity in the film structure. By adding CF{sub 4} in the deposition process, fluorine, the most electronegative and the least polarized atom, doped into the silica film and led to decrease in the refractive index and the dielectric constant. In addition, no breakdown field was observed in the electrical characteristics of SiO{sub x}C{sub y}F{sub z} films and the leakage current of these films reduced by increment of the CF{sub 4} flow.

36 MATERIALS SCIENCE↗

Fluctuations and power-law scaling of dry, frictionless granular rheology near the hard-particle limit

Here the flow of frictionless granular particles is studied with stress-controlled discrete element modeling simulations for systems varying in size from 300 to 100,000 particles. The volume fraction and shear-stress ratio μ are relatively insensitive to system size for a wide range of inertial numbers I. Second-order effects in strain rate, such as normal stress differences, require large system sizes to accurately extract meaningful results, notably a nonmonotonic dependence in the first normal stress difference with strain rate. The rheological response represented by the μ(I) scalar model works well at describing the lower-order aspects of the rheology, except near the quasistatic limit of these stress-controlled flows. The pressure is varied over five decades, and a pressure dependence of the coordination number is observed, which is not captured by the inertial number. Large fluctuations observed for small systems N≤1000 near the quasistatic limit can lead to the arrest of flow resulting in challenges to fitting the data to rheological relationships. The inertial number is also insufficient for capturing the pressure-dependent behavior of property fluctuations. Fluctuations in the flow and microstructural properties are measured in both the quasistatic and inertial regimes, including shear stress, pressure, strain rate, normal stress differences, volume fraction, coordination number, and contact fabric anisotropy. The fluctuations in flow properties scale self-similarly with pressure and system size. A transition in the scaling of fluctuations of stress properties and contact fabric anisotropy are measured and proposed as a quantitative identification of the transition from inertial to quasistatic flow.

36 MATERIALS SCIENCE↗

Performance Evaluation of Distributed Energy Resource Management Algorithm in Large Distribution Networks

This paper presents performance evaluation of hierarchical optimization and control for distributed energy resource management system (DERMS) in large distribution networks via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of a full-scale distribution system of 11,000 nodes, the DERMS software controller, and 90 power hardware photovoltaics (PVs) and battery inverters. The applied DERMS algorithm is designed based on a realtime optimal power flow algorithm and implemented with acceleration design that performs fast dispatch of simulated PVs and real physical hardware DER devices every 4 seconds.

DERMS↗

Verdant Power TriFrame, Gen5 KHPS Turbine, and BOP System Content Models

This submission includes System Content Models with data following manufacture for the Verdant Power TriFrame, Gen5 Kinetic Hydropower System (KHPS) Turbines, and Balance of Plant (BOP). The TriFrame installs 3 Gen5 KHPS Turbines. The BOP system controls the turbines and interconnects the TriFrame to shoreline with supervisory control and data acquisition (SCADA).

16 TIDAL AND WAVE POWER↗

AmeriFlux US-Blo Blodgett Forest

This is the AmeriFlux version of the carbon flux data for the site US-Blo Blodgett Forest. Site Description - The flux tower site at Blodgett Forest is on a 1200 ha parcel of land owned by Sierra Pacific Industries in the Sierra Nevada range near Georgetown, California. The field site was established in May 1997 with continuous operation since May 1999. The site is situated in a ponderosa pine plantation, mixed-evergreen coniferous forest, located adjacent to Blodgett Forest Research Station. The Mediterranean-type climate of California is characterized by a protracted summer drought, with precipitation occurring mainly from October through May. The infrastructure for the ecosystem scale flux measurements includes a walkup measurement tower, two temperature controlled instrument buildings, and an electrical generation system powered by a diesel generator. Typical wind patterns at the site include upslope flow during the day (from the west) and downslope flow at night (from the east). The plantation is relatively flat, and contains a homogenous mixture of evenly aged ponderosa pine with other trees and shrubs scattered throughout the ecosystem making up less than 30% of the biomass. The daytime fetch for the tower measurements extends approximately 200 m to the southwest of the tower (this region contributes ~90% of the daytime flux), thus remote sensing images to be used for modeling should probably be centered approximately 100 m from the tower at an angle of 225 deg.

Goldstein, Allen↗

Cooperative Research and Development Agreement among National Energy Technology Laboratory, The Board of Regents of the University System of Georgia by and on behalf of Georgia Institute of Technology, and University of Texas at El Paso [Abstract]

Georgia Institute of Technology (GIT), University of Texas at El Paso (UTEP), and the National Energy Technology Laboratory (NETL) will collaborate and develop cyber-physical systems for advanced power systems. GIT will test virtual models on hybrid power system hardware and cyber physical components. UTEP will test novel actuators on hybrid power system hardware. NETL will access GIT’s expertise in the engineering and real time simulation of power system processes for cyber-physical systems and simulations to control hardware. NETL will establish a relationship to promote UTEP’s capabilities in additive manufacturing and high-temperature piezo-electric devices with the potential for controlling high-temperature flows with a light and inexpensive device at high response rates. This project is the result of an EERE Advanced Manufacturing Office open Multi-Topic awarded proposal led by GIT titled, “Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration”.

42 ENGINEERING↗

Development of an Accurate Feed-Forward Temperature Control Tankless Water Heater

The following document is the final report for DE-FC26-05NT42327: Development of an Accurate Feed-Forward Temperature Control Tankless Water Heater. This work was carried out under a cooperative agreement from the Department of Energy's National Energy Technology Laboratory, with additional funding from Keltech, Inc. The objective of the project was to improve the temperature control performance of an electric tankless water heater (TWH). The reason for doing this is to minimize or eliminate one of the barriers to wider adoption of the TWH. TWH use less energy than typical (storage) water heaters because of the elimination of standby losses, so wider adoption will lead to reduced energy consumption. The project was carried out by Building Solutions, Inc. (BSI), a small business based in Omaha, Nebraska. BSI partnered with Keltech, Inc., a manufacturer of electric tankless water heaters based in Delton, Michigan. Additional work was carried out by the University of Nebraska and Mike Coward. A background study revealed several advantages and disadvantages to TWH. Besides using less energy than storage heaters, TWH provide an endless supply of hot water, have a longer life, use less floor space, can be used at point-of-use, and are suitable as boosters to enable alternative water heating technologies, such as solar or heat-pump water heaters. Their disadvantages are their higher cost, large instantaneous power requirement, and poor temperature control. A test method was developed to quantify performance under a representative range of disturbances to flow rate and inlet temperature. A device capable of conducting this test was designed and built. Some heaters currently on the market were tested, and were found to perform quite poorly. A new controller was designed using model predictive control (MPC). This control method required an accurate dynamic model to be created and required significant tuning to the controller before good control was achieved. The MPC design was then implemented on a prototype heater that was being developed simultaneously with the controller development. (The prototype's geometry and components are based on a currently marketed heater, but several improvements have been made.) The MPC's temperature control performance was a vast improvement over the existing controller. With a benchmark for superior control performance established, five additional control methods were tested. One problem with MPC control is that it was found to be extremely difficult to implement in a TWH, so that it is unlikely to be widely adopted by manufacturers. Therefore the five additional control methods were selected based on their simplicity; each could be implemented by a typical manufacturer. It was found that one of these methods performed as well as MPC, or even better under many circumstances. This method uses a Feedback-Compensated Feed-Forward algorithm that was developed for this project. Due to its simplicity and excellent performance this method was selected as the controller of choice. A final higher-capacity prototype heater that uses Feedback-Compensated Feed-Forward control was constructed. This prototype has many improvements over the currently marketed heaters: (1) excellent control; (2) a modular design that allows for different capacity heaters to be built easily; (3) built-in fault detection and diagnosis; (4) a secondary remote user-interface; and (5) a TRIAC switching algorithm that will minimize 'flicker factor'. The design and engineering of this prototype unit will allow it to be built without an increase in cost, compared with the currently marketed heater. A design rendering of the new product is shown below. It will be launched with a new marketing campaign by Keltech in early 2009.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preventing stent failure using adaptive shear responsive endovascular implant

A stent apparatus, system, and method that senses wall shear stress by measuring fluid flow at localized areas within the stent, that processes measured information through an integrated circuit, and selectively sends power to mechanically controllable stent surfaces which results in localized geometric changes. In various embodiments the stent apparatus, system, and method sends data to outside the body in real time.

Mukerjee, Erik V.↗

Preventing stent failure using adaptive shear responsive endovascular implant

A stent apparatus, system, and method that senses wall shear stress by measuring fluid flow at localized areas within the stent, that processes measured information through an integrated circuit, and selectively sends power to mechanically controllable stent surfaces which results in localized geometric changes. In various embodiments the stent apparatus, system, and method sends data to outside the body in real time.

Mukerjee, Erik V.↗

Model predictive direct power control for active power decoupled single-phase quasi- Z -source inverter

In this study, the active power filter (APF) that consists of a half-bridge leg and an ac capacitor is integrated in the single-phase quasi-Z-source inverter (qZSI) in this paper to avoid the second harmonic power flowing into the dc side. The capacitor of APF buffers the second harmonic power of the load, and the ac capacitor allows highly pulsating ac voltage, so that the capacitances of both dc and ac sides can be small. A model predictive direct power control (DPC) is further proposed to achieve the purpose of this newtopology through predicting the capacitor voltage of APF at each sampling period and ensuring the APF power to track the second harmonic power of single-phase qZSI. Simulation and experimental results verify the model predictive DPC for the APF-integrated single-phase qZSI.

30 DIRECT ENERGY CONVERSION↗

TEAMER – Harvesting Subsea Water Motion to Provide Clean Electrical Power (Abstract)

Power generation from vortex induced vibration (VIV) is an emerging field with new technologies that are just beginning to be field tested. In this TEAMER project, WITT Energy will be field testing the power production of its pendulum system in two different configurations to evaluate its performance. The amount of power produced by a VIV instrument depend on the frequency at which it vibrates. The vibrational frequency is controlled by the device shape and its interaction with the flow velocity. Computer models are used to predict vibration frequencies as a function of flow velocity but they may be inaccurate due to complicated bathymetry and bottom roughness that is not captures by the models. This project will test the WITT VIV device in the Sequim Bay channel over a range of tidal velocities. Two tests will be completed with different pipe lengths that are expected to vary the vibrational frequency and therefore the power produced. PNNL will use an acoustic doppler current profiler (ADCP) to monitor the flow conditions during the tests. These tests will help WITT Energy evaluate how closely field operations follow computer model predictions and how best to configure their device for electricity production.

16 TIDAL AND WAVE POWER↗

Evaluating large scale aqueous organic redox flow battery performance with a hybrid numerical and machine learning framework

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low-capacity degradation in 10 cm$^2$ cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier to commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm$^2$ DHP-based AORFB by combining a physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. Such combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Newton-Raphson AC Power Flow Convergence Based on Deep Learning Initialization and Homotopy Continuation

Power flow forms the basis of many power system studies. With the increased penetration of renewable energy, grid planners tend to perform multiple power flow simulations under various operating conditions and not just selected snapshots at peak or light load conditions. Getting a converged AC power flow (ACPF) case remains a significant challenge for grid planners especially in large power grid networks. This paper proposes a two-stage approach to improve Newton-Raphson ACPF convergence and was applied to a 6102 bus Electric Reliability Council of Texas (ERCOT) system. The first stage utilizes a deep learning-based initializer with data re-training. Here a deep neural network (DNN) initializer is developed to provide better initial voltage magnitude and angle guesses to aid in power flow convergence. This is because Newton-Raphson ACPF is quite sensitive to the initial conditions and bad initialization could lead to divergence. The DNN initializer includes a data re-training framework that improves the initializer's performance when faced with limited training data. The DNN initializer successfully solved 3,285 cases out of 3,899 non-converging dispatch and performed better than random forest and DC power flow initialization methods. ACPF cases not solved in this first stage are then passed through a hot-starting algorithm based on homotopy continuation with switched shunt control. The hot-starting algorithm successfully converged 416 cases out of the remaining 614 non-converging ACPF dispatch. In conclusion, the combined two-stage approach achieved a 94.9% success rate, by converging a total of 3,701 cases out of the initial 3,899 unsolved cases.

Deep learning↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Load following capability of CANDLE reactor by adjusting coolant operation condition

The load following capability of CANDLE reactor is investigated in the condition that the control rods are unavailable. Both sodium cooled metallic fuel fast reactor (SFR) and {sup 208}Pb cooled metallic fuel fast reactor (LFR) are investigated for their performance in power rate changing by changing its coolant operation condition; either coolant flow rate or coolant inlet temperature. The change by coolant flow rate is difficult especially for SFR because the maximum temperature criteria on cladding material may be violated. The power rate can be changed for its full range easily by changing the coolant temperature at the core inlet. LFR can reduce the same amount of power rate by smaller change of temperature than SFR. However, the coolant output temperature is generally decreased for this method and the thermal efficiency becomes worse.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Turbine Control of a Tidal and River Power Generator

As renewable generation has become less expensive during recent decades, and it becomes more accepted by the global population, the focus on renewable generation has expanded to include new types with promising future applications, such as river and tidal generation. The input variations to these types of resources are slower but also steadier than wind or solar generation. The level of water turbulent flow may vary from one place to another, however, the control algorithm can be adjusted to local environment. This paper describes the hydrokinetic aspects of river and tidal generation based on a river and tidal generator. Although the information given in this paper is not that of an exact generator deployed on site, the data used is representative of a typical river or tidal generator. In this paper, the hydrokinetic and associated electrical controller of the system were not included; however, the focus of this paper is on the hydrodynamic control.

13 HYDRO ENERGY↗