Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Quantum Plasmonic Sensors

The extraordinary sensitivity of plasmonic sensors is well-known in the optics and photonics community. These sensors exploit simultaneously the enhancement and the localization of electromagnetic fields close to the interface between a metal and a dielectric. This enables, for example, the design of integrated biochemical sensors at scales far below the diffraction limit. Despite their practical realization and successful commercialization, the sensitivity and associated precision of plasmonic sensors are starting to reach their fundamental classical limit given by quantum fluctuations of light—known as the shot-noise limit. To improve the sensing performance of these sensors beyond the classical limit, quantum resources are increasingly being employed. This area of research has become known as “quantum plasmonic sensing”, and it has experienced substantial activity in recent years for applications in chemical and biological sensing. This review aims to cover both plasmonic and quantum techniques for sensing, and it shows how they have been merged to enhance the performance of plasmonic sensors beyond traditional methods. We discuss the general framework developed for quantum plasmonic sensing in recent years, covering the basic theory behind the advancements made, and describe the important works that made these advancements. We also describe several key works in detail, highlighting their motivation, the working principles behind them, and their future impact. The intention of the review is to set a foundation for a burgeoning field of research that is currently being explored out of intellectual curiosity and for a wide range of practical applications in biochemistry, medicine, and pharmaceutical research.

47 OTHER INSTRUMENTATION↗

Uncovering temperature-dependent exciton-polariton relaxation mechanisms in hybrid organic-inorganic perovskites

Hybrid perovskites have emerged as a promising material candidate for exciton-polariton (polariton) optoelectronics. Thermodynamically, low-threshold Bose-Einstein condensation requires efficient scattering to the polariton energy dispersion minimum, and many applications demand precise control of polariton interactions. Thus far, the primary mechanisms by which polaritons relax in perovskites remains unclear. In this work, we perform temperature-dependent measurements of polaritons in low-dimensional perovskite wedged microcavities achieving a Rabi splitting of ℏΩ Rabi = 260 ± 5 meV. We change the Hopfield coefficients by moving the optical excitation along the cavity wedge and thus tune the strength of the primary polariton relaxation mechanisms in this material. We observe the polariton bottleneck regime and show that it can be overcome by harnessing the interplay between the different excitonic species whose corresponding dynamics are modified by strong coupling. This work provides an understanding of polariton relaxation in perovskites benefiting from efficient, material-specific relaxation pathways and intracavity pumping schemes from thermally brightened excitonic species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proton reconstruction with the TOTEM Roman pot detectors for high- β * LHC data

The TOTEM Roman pot detectors are used to reconstruct the transverse momentum of scattered protons and to estimate the transverse location of the primary interaction. This paper presents new methods of track reconstruction, measurements of strip-level detection efficiencies, cross-checks of the LHC beam optics, and detector alignment techniques, along with their application in the selection of signal collision events. The track reconstruction is performed by exploiting hit cluster information through a novel method using a common polygonal area in the intercept-slope plane. The technique is applied in the relative alignment of detector layers with μm precision. A tag-and-probe method is used to extract strip-level detection efficiencies. The alignment of the Roman pot system is performed through time-dependent adjustments, resulting in a position accuracy of 3 μm in the horizontal and 60 μm in the vertical directions. The goal is to provide an optimal reconstruction tool for central exclusive physics analyses based on the high-β* data-taking period at $\sqrt({s})$ = 13 TeV in 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mid-infrared spectroscopy with a broadly tunable thin-film lithium niobate optical parametric oscillator

Mid-infrared spectroscopy, an important technique for sensing molecules, has encountered barriers from sources either limited in tuning range or excessively bulky for widespread use. We present a compact, efficient, and broadly tunable optical parametric oscillator surmounting these challenges. Leveraging dispersion-engineered thin-film lithium niobate-on-sapphire photonics and a singly resonant cavity allows broad, controlled tuning over an octave from 1.5–3.3 µm. The device generates >25mW of mid-infrared light at 3.2 µm with 15% conversion efficiency. The ability to precisely control the device’s mid-infrared emission enables spectroscopy of methane and ammonia, demonstrating our approach’s relevance for sensing. Our work signifies an important advance in nonlinear photonics miniaturization, bringing practical field applications of high-speed, broadband mid-infrared spectroscopy closer to reality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On optical properties and scintillation performance of emerging Ga 2 O 3 : Crystal growth, emission mechanisms and doping strategies

As an emerging ultra-wide bandgap compound semiconductor, Ga 2 O 3 has attracted rapidly growing interest due to its unique physical properties for harsh condition applications. Compared to Ga 2 O 3 ’s electrical-characteristic based uses, such as power electronics, photodetectors and solar cells, a much less explored area for Ga 2 O 3 is its promising optical properties and its related scintillation capabilities. Undoped Ga 2 O 3 is a strong scintillator with excellent scintillation characteristics such as fast decay constants and encouraging light yield which is comparable to that of the classic Bi 4 Ge 3 O 12 (BGO) scintillator. The scintillation capability of Ga 2 O 3 can be precisely tuned via a series of approaches including systematic crystal growth control, post-growth annealing, targeted doping, and optimization of operation temperature. Here we summarize exciting progress of Ga 2 O 3 scintillators which have been pursued over the past few years. Our efforts cover a series of growth techniques of Ga 2 O 3 materials as well as discussion of emission mechanisms. Here we dedicate a targeted portion toward the doping strategies to improve the performance of Ga 2 O 3 . A detailed analysis is provided to compare the impact of different dopants. Through these efforts, we hope to provide useful perspectives to help accelerate the development of high performance Ga 2 O 3 scintillators.

36 MATERIALS SCIENCE↗

Probing the Mechanism of Cadmium Sulfide Cluster Nucleation and Growth via Sequential Infiltration Synthesis

Few-atom metal chalcogenide clusters may be realized through the sequential infiltration of metal–organic precursors in polymer films. However, the underlying nucleation and growth mechanisms that allow for cluster synthesis with near atomic-scale precision are not fully resolved. The kinetics of the sequential infiltration synthesis (SIS) method that control the nucleation and growth mechanisms of primarily Cd 4 S 4 -core clusters within a poly­(4-vinylpyridine) (P4VP) matrix are probed with in situ UV–visible absorbance spectroscopy. Density functional theory (DFT) calculations that allow simulation of the optical properties of cluster fragments further reveal the thermodynamics that guide cluster growth within the P4VP matrix. Here, we conclude that a reactive capture mechanism for cluster nucleation and growth is dominant, although transient dimethyl cadmium adduction to the polymer backbone may contribute to cluster nucleation under shorter metal–organic purge process conditions. Grazing incidence X-ray diffraction (GI-XRD) and X-ray absorption spectroscopy (XAS) analyses further corroborate the cluster size and atom connectivity throughout the stepwise synthesis.

Jayaweera, Nuwanthaka P. [Argonne National Laborat↗

CdSe Magic-Size Clusters Deviate from Nanocrystal-Size Scalings for Ultrafast Intraband Relaxation and Auger Recombination

The cluster regime of colloidal semiconductor quantum dots (QDs) occupies an interesting space on the continuum from molecule to bulk material and allow the study of QD properties at extreme quantum confinement limits. For typical QDs, several size-dependent property trends are well established including intraband relaxation rates and universal scaling of Auger recombination with particle volume. Advances in synthesis now allow isolation of atomically precise semiconductor magic-size clusters (MCs), which offer experimental insight regarding how electronic structure changes with particle size in the ultrasmall limit. Here, we report intraband cooling and Auger recombination for several stable CdSe MCs as a function of particle size and observe deviation from QD response in the cluster regime. We additionally show optical signatures ascribed to transient disordering 2 that appear in the single exciton regime for MCs, which point to complexities regarding their implementation.

Auger recombination↗

Tunable interaction between excitons and hybridized magnons in a layered semiconductor

The interaction between distinct excitations in solids is of both fundamental interest and technological importance. One example of such interactions is coupling between an exciton, a Coulomb bound electron-hole pair, and a magnon, a collective spin excitation. The recent emergence of van der Waals magnetic semiconductors1 provides a powerful platform for exploring these exciton-magnon interactions and their fundamental properties, such as strong correlation2, as well as their photo-spintronic and quantum transduction3 applications. Here we demonstrate precise control of coherent exciton-magnon interactions in the layered magnetic semiconductor CrSBr. We show that by controlling the direction of applied magnetic fields relative to the crystal axes, and thus the rotational symmetry of the magnetic system4, we can tune not only the exciton coupling to the bright magnon, but also to an optically dark mode via magnon hybridization. The exciton-magnon coupling and associated magnon dispersion curves can be further modulated by applying a uniaxial strain. At the critical strain, a dispersionless dark magnon band emerges. Our results demonstrate unprecedented control of the opto-mechanical-magnonic coupling, and a step towards the predictable and controllable implementation of hybrid quantum magnonics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design of experiments to spectroscopically characterize radiation flow in stochastic media

Precise characterization of experimental radiation flow is required to validate the high energy density physics models, numerical methods, and codes that are used to simulate radiation-hydrodynamics phenomena such as thermal radiation transport in stochastic media. The Cassio code is used to simulate thermal radiation flow through inhomogeneous, stochastic-media-foam configurations containing optically thick clumps dispersed within an optically thin background aerogel. Cassio can model small inhomogeneous problems directly, but most problems require approximations to meet computer limitations on run-times and memory usage. Various examples of these approximations are methods that produce, in one calculation, an ensemble-averaged solution and associated standard deviation; reduced spatial dimensionality with approximate geometries; and full material homogenization with no geometric detail. Cassio simulations are used to design experiments at the OMEGA-60 Laser Facility that can measure the radiation flow using the spatially resolved COAX absorption spectroscopy diagnostic. The experimental platforms flow radiation through foam targets ranging from a background-only aerogel, to a single configuration of a specified stochastic medium, to a fully homogenized foam of the background and clump materials. Under constant total clump mass, larger clumps (here, larger than 10 μm diameter) will mix more slowly with the background such that the bulk radiation flow is faster than it would be in a fully homogenized material. The COAX platform can be used to infer temperature and density profiles in both the background material and clumps, simultaneously, and therefore to differentiate radiation flow in a range of stochastic and homogeneous media.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Label-free DNA biosensing by topological light confinement

Large-area and transparent all-dielectric metasurfaces sustaining photonic bound states in the continuum (BICs) provide a set of fundamental advantages for ultrasensitive biosensing. BICs bridge the gap of large effective mode volume with large experimental quality factor. Relying on the transduction mechanism of reactive sensing principle, herein, we first numerically study the potential of subwavelength confinement driven by topological decoupling from free space radiation for BIC-based biosensing. Then, we experimentally combine this capability with minimal and low-cost optical setup, applying the devised quasi-BIC resonator for PNA/DNA selective biosensing with real-time monitoring of the binding event. A sensitivity of 20 molecules per micron squared is achieved, i.e. ≃0.01 pg. Further enhancement can easily be envisaged, pointing out the possibility of single-molecule regime. This work aims at a precise and ultrasensitive approach for developing low-cost point-of-care tools suitable for routine disease prescreening analyses in laboratory, also adaptable to industrial production control.

59 BASIC BIOLOGICAL SCIENCES↗

Development of advanced machine learning models for analysis of plutonium surrogate optical emission spectra

This work investigates and applies machine learning paradigms seldom seen in analytical spectroscopy for quantification of gallium in cerium matrices via processing of laser-plasma spectra. Ensemble regressions, support vector machine regressions, Gaussian kernel regressions, and artificial neural network techniques are trained and tested on cerium-gallium pellet spectra. A thorough hyperparameter optimization experiment is conducted initially to determine the best design features for each model. The optimized models are evaluated for sensitivity and precision using the limit of detection (LoD) and root mean-squared error of prediction (RMSEP) metrics, respectively. Gaussian kernel regression yields the superlative predictive model with an RMSEP of 0.33% and an LoD of 0.015% for quantification of Ga in a Ce matrix. This study concludes that these machine learning methods could yield robust prediction models for rapid quality control analysis of plutonium alloys.

Rao, Ashwin P. (ORCID:0000000319312568)↗

Improving Energy Transfer within Metal–Organic Frameworks by Aligning Linker Transition Dipoles along the Framework Axis

Crystalline metal-organic frameworks (MOFs) can assemble chromophoric molecules into a wide range of spatial arrangements, which are controlled by the MOF topology. Like natural light-harvesting complexes (LHCs), the precise arrangement modulates interchromophoric interactions, in turn determining excitonic behavior and migration dynamics. To unveil the key factors that control efficient exciton displacements within MOFs, we first developed linkers with low electronic symmetry (as defined by large transition dipoles) and then assembled them into MOFs. These linkers possess extended conjugation along one molecular axis, engendering low optical bandgaps and improved oscillator strength for their lowest-energy transition (S 0 → S 1 ). This enhances absorption-emission spectral overlap and boosts the efficiency of Forster resonance energy transfer, which was observed experimentally by a sizable decrease in emission quantum yield (QY), accompanied by a faster population decay profile. We find that MOFs that orient these elongated linkers along their asymmetric pore channel, e.g., the hexagonal pores in an xly network, manifested >50% decrease in their emission QY with faster decay profiles relative to their corresponding solution dissolved linkers. This is due to an efficient migration of photogenerated excitons at the crystallite peripheral sites to internal sites, which was facilitated by polarized absorption-emission overlap among the parallelly aligned linkers. In contrast, symmetric MOFs, such as those with sqc-a topological net, orient elongated linkers along two perpendicular crystal axes, which hinders efficient exciton migration. This study underscores that MOFs are promising to develop artificial LHCs, but that to achieve an efficient exciton displacement, appropriate topology-guided assembly is required to fully realize the true potential of linkers with low electronic symmetry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High precision control of laser energy for laser–matter interaction studies

Precise, highly reproducible control of the laser energy is required for high confidence laser–matter interaction research such as in dynamic compression science and high energy density physics. The energy must be adjustable without affecting the pulse shape (time varying intensity) or beam smoothness. We have developed a convenient two-stage energy tuning method for a nominal 100 J, 351 nm (UV) laser. The energy is adjusted in 10 J (10%) increments by operating the laser at full energy and inserting a beam splitter in the laser output. As the splitter is located after the final frequency tripling optics, the UV pulse shape is unchanged. The energy is varied by substituting a splitter of different reflectivity. For finer 3 J (3%) increments, the infrared pulse is attenuated inside the laser before the final amplifier. This requires modest tuning to preserve the pulse shape. The demonstrated variation in shot-to-shot reproducibility is less than +/–2.5 J (5% of the full energy), irrespective of the laser output energy. These approaches can be adapted to most ~100 J class lasers. We describe these techniques and show two examples where they have elucidated the underlying physics in laser shock compression experiments. One used only the beam splitters to establish the pressure for melting in iron. The other combined both techniques to finely increment the peak stress (~2 GPa steps) in germanium to precisely determine the onset and completion of melting—including the melting kinetics. Furthermore, these unambiguous results would not be possible without the developments described here.

47 OTHER INSTRUMENTATION↗

Defect Engineering in Large‐Scale CVD‐Grown Hexagonal Boron Nitride: Formation, Spectroscopy, and Spin Relaxation Dynamics

Recently, numerous techniques have been reported for generating optically active defects in exfoliated hexagonal boron nitride (hBN), which hold transformative potential for quantum photonic devices. However, achieving on-demand generation of desirable defect types in scalable hBN films remains a significant challenge. Here, it is demonstrated that formation of negative boron vacancy defects, V B − , in suspended, large-area CVD-grown hBN is strongly dependent on the type of bombarding particles (ions, neutrons, and electrons) and irradiation conditions. In contrast to suspended hBN, defect formation in substrate-supported hBN is more complex due to the uncontrollable generation of secondary particles from the substrate, and the outcome strongly depends on the thickness of the hBN. Different defect types are identified by correlating spectroscopic and optically detected magnetic resonance features, distinguishing boron vacancies (formed by light ions and neutrons and emitting at 800 nm) from other optically active defects emitting at 650 nm assigned to anti-site nitrogen vacancy (N B V N ) and reveal the presence of additional “dark” paramagnetic defects that influence spin-lattice relaxation time (T 1 ) and zero-field splitting parameters, all of which strongly depend on the defect density. These results underscore the potential for precisely engineered defect formation in large-scale CVD-grown hBN, paving the way for the scalable fabrication of quantum photonic devices.

CVD↗

Generation of realistic input parameters for simulating atmospheric point-spread functions at astronomical observatories

High-fidelity simulated astronomical images are an important tool in developing and measuring the performance of image-processing algorithms, particularly for high precision measurements of cosmic shear – correlated distortions of images of distant galaxies due to weak gravitational lensing caused by the large-scale mass distribution in the Universe. For unbiased measurements of cosmic shear, all other sources of correlated image distortions must be modeled or removed. One such source is the correlated blurring of images due to optical turbulence in the atmosphere, which dominates the point-spread function (PSF) for ground-based instruments. In this work, we leverage data from weather forecasting models to produce wind speeds and directions, and turbulence parameters, that are realistically correlated with altitude. To study the resulting correlations in the size and shape of the PSF, we generate simulated images of the PSF across a ~10 square-degree field of view – the size of the camera focal plane for the Vera C. Rubin Observatory in Chile – using weather data and historical seeing for a geographic location near the Observatory. We make quantitative predictions for two-point correlation functions (2PCF) that are used in analyses of cosmic shear. We observe a strong anisotropy in the two-dimensional 2PCF, which is expected based on observations in real images, and study the dependence of the orientation of the anisotropy on dominant wind directions near the ground and at higher altitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗

Mathematical Underpinnings of the Multiwavelength Structure of the Tip of the Red Giant Branch

We consider the application of the tip of the red giant branch (TRGB) in the optical and in the near-infrared for the determination of distances to nearby galaxies. We analyze ACS VI (F555W and F814W) data and self-consistently cross-calibrate WFC3-IR JH (F110W and F120W) data using an absolute magnitude calibration of M {sub I} = −4.05 mag as determined in the Large Magellanic Cloud using detached eclipsing binary star geometric parallaxes. We demonstrate how the optical and near-infrared calibrations of the TRGB method are mathematically self-consistent, and illustrate the mathematical basis and relations among these multiwavelength calibrations. We go on to present a method for determining the reddening, extinction, and the true modulus to the host galaxy using multiwavelength data. The power of the method is that with high-precision data, the reddening can be determined using the TRGB stars themselves, and decreases the systematic (albeit generally small) uncertainty in distance due to reddening for these halo stars.

79 ASTRONOMY AND ASTROPHYSICS↗