Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Charge injection device as a candidate sensor for stellar tracking

Charge transfer devices (CTDs) are superior to the image dissector as stellar tracking sensors, considering their low voltage requirements, insensitivity to magnetic fields, good linearity, and low weight and power. An analysis of one type of CTD, called the charge injection device (CID), revealed an X-Y addressing capability which provides exceptional flexibility in array readout and results in enhanced S/N capability, a surface channel device which produces a larger dynamic range of operation, and exceptional and unique tolerance to optical overloads. A 128 row by 128 column CID array processed on silicon was evaluated in a cooled breadboard camera, and measured results indicate projected performance parameters of a large area CID array as follows: 20 micron square sensing site, noise not greater than 25 carriers per pixel, quantum yield of approximately 40% from 0.4 to 1.0 micron, and cooling requirements on the order of 0 degrees C.

Jones, C. S., Jr.↗

Detector arrays for photometric measurements at soft X-ray, ultraviolet and visible wavelengths

The construction and modes of operation of the Multi-Anode Microchannel Array (MAMA) detectors are described, and the designs of spectrometers utilizing them are outlined. MAMA consists of a curved microchannel array plate, an opaque photocathode (peak quantum efficiency of 19% at 1216 A), and a multi-anode (either discrete- or coincidence-anode) readout array. Designed for use in instruments on spaceborne telescopes, MAMA can be operated in a windowless configuration in extreme-ultraviolet and soft X-ray wavelengths, or in a sealed configuration at UV and visible wavelengths. Advantages of MAMA include low applied potential (less than 3.0 kV), high gain (greater than 10 to the 6th electrons/pulse), low sensitivity to high-energy charged particles, and immunity to external magnetic fields of less than 500 Gauss

Timothy, J. G.↗

A fully monolithic InSb infrared CCD array

Fully monolithic infrared CCD arrays fabricated in InSb are described. The process used in fabrication includes planar junction formation by ion implantation, and an aluminum and SiO2 overlapping CCD gate structure which makes use of conventional chemical and plasma etching. IR detection and readout is demonstrated with the arrays.

Thom, R. D.↗

Log-Output Signal Processor Scans Eight Decades

Processor has automatic range switching and continuous readout over eight decades. Comparator output switches logarithmic converter to detector of interest and enables blinder grid to protect more-sensitive detector when operating in high-input range. Could be used to process any wide-varying signal that is to be read on a limited-range recording device such as a strip-chart recorder.

Hayden, J. L.↗

Portable Radiometer Monitors Plant Growth

Three-band hand-held spectral radiometer measures electromagnetic energy reflected from plant canopies in the visible and infrared portions of the spectrum. It is mobile and easy to use for rapid, repeated measurements. Radiometer probe is held level over plant canopy, readout range switches are set and measurements are recorded. Chlorophyll content, leaf area index and leaf water content can be quickly and easily measured.

Tucker, C. J., III↗

Electronically Calibratable Clock

Calibration circuit corrects apparent clock rate (ACR) of digital clock without altering oscillator frequency. Calibration circuit does not require iterative adjustments to reference frequency or rate, and correction to ACR is controlled by pushbuttons. Technique is applicable to any timer or counter that counts up to predetermined number then outputs a pulse to a readout register or to control another device.

Davidson, J. R.↗

Cryogenic switched MOSFET characterization

Both p channel and n channel enhancement mode MOSFETs can be readily switched on and off at temperatures as low as 2.8 K so that switch sampled readout of a VLWIR Ge:Ga focal plane is electronically possible. Noise levels as low as 100 rms electrons per sample (independent of sample rate) can be achieved using existing p channel MOSFETs, at overall rates up to 30,000 samples/second per multiplexed channel (e.g., 32 detectors at a rate of almost 1,000 frames/second). Run of the mill devices, including very low power dissipation n channel FETs would still permit noise levels of the order of 500 electrons/sample.

Source record↗

Charge injection device evaluation hardware

A microprocessor based system which provides maximum testing flexibility via software reconfiguration is described. This system has the capability to evaluate a charge injection device (CID) and to characterize its performance. The construction and operation of the CID offer advantages over the various CCD configurations available. These advantages include a less sophisticated manufacturing process, no images smearing during readout, high transfer efficiencies, and high resistance to blooming due to optical overload.

Source record↗

Time delay and integration detectors using charge transfer devices

An imaging system comprises a multi-channel matrix array of CCD devices wherein a number of sensor cells (pixels) in each channel are subdivided and operated in discrete intercoupled groups of subarrays with a readout CCD shift register terminating each end of the channels. Clock voltages, applied to the subarrays, selectively cause charge signal flow in each subarray in either direction independent of the other subarrays. By selective application of four phase clock voltages, either one, two or all three of the sections subarray sections cause charge signal flow in one direction, while the remainder cause charge signal flow in the opposite direction. This creates a form of selective electronic exposure control which provides an effective variable time delay and integration of three, six or nine sensor cells or integration stages. The device is constructed on a semiconductor sustrate with a buried channel and is adapted for front surface imaging through transparent doped tin oxide gates.

Mccann, D. H.↗

Superconducting tensor gravity gradiometer for satellite geodesy and inertial navigation

A sensitive gravity gradiometer can provide much needed gravity data of the earth and improve the accuracy of inertial navigation. Superconductivity and other properties of materials at low temperatures can be used to obtain a sensitive, low-drift gravity gradiometer; by differencing the outputs of accelerometer pairs using superconducting circuits, it is possible to construct a tensor gravity gradiometer which measures all the in-line and cross components of the tensor simultaneously. Additional superconducting circuits can be provided to determine the linear and angular acceleration vectors. A tensor gravity gradiometer with these features is being developed for satellite geodesy. The device constitutes a complete package of inertial navigation instruments with angular and linear acceleration readouts as well as gravity signals.

Paik, H. J.↗

Low-power portable geophysical data acquisition system and its use in geomagnetic measurements

A low-power portable data acquisition system presently in use for geomagnetic measurements is described. The system is composed of a data-processing system containing a low-power microprocessor, a 9-track digital tape recorder, and a rechargeable battery pack. The magnetometer is a low-power three axis fluxgate design. Under program control the data processing system keeps track of time of day and date, samples three analog magnetometer outputs at intervals of either 0.4 or 2 s, digitizes the data to 15-bit resolution, and, depending upon relative magnetic activity, decides upon data compression to increase the tape storage capacity. It also monitors and records internal voltages and provides self-checking functions which may be monitored through a visual readout on the control panel. The system is mounted in a rugged, weather-tight carrying case suitable for use outdoors with minimal protection. The system, including magnetometer, uses 1.6-W power and can store 5.7 Mbytes of data.

Medford, L. V.↗

High speed techniques for synthetic aperture radar image formation

One possible approach to high speed synthetic aperture radar signal reconstruction involves the utilization of two dimensional real time spatial light modulators as recyclable replacements for photographic film in the input transducer plane of a modified synthetic aperture radar (SAR) coherent optical processor. Leading candidate spatial light modulators include modified Pockels readout optical modulators (PROM), charge coupled devices (CCD) addressed liquid crystal light valves, and CCD addressed membrane light modulators. The fundamental physical limitations affecting SAR processor performance characteristics of such real time devices are under investigation. Current research on PROM is focused on the effects of device operatonal mode, device constitutive parameters, electro-optic crystal orientation, writing wavelength, frame rate/data overwrite/presuming, erasure completeness, and image retention on the overall quality of SAR image formation. Both modulated laser scanning and intensified CRT temporal to spatial input approaches are being examined.

Psaltis, D.↗

Microchannel spatial light modulator

The Microchannel Spatial Light Modulator (MSLM), a versatile, highly sensitive, and optically addressed device being developed for real time optical information processing is discussed. The MSLM operates by converting an input optical image into a charge distribution at the surface of an electro-optic crystal. The charge distribution generates an electric field which modulates the refractive index of the crystal and thereby the phase or intensity of an image readout beam. Prototype devices employing 250 micron thick crystals exhibited a spatial resolution of 5 cycles/mm at 50% contrast, an exposure sensitivity of 2.2 nJ/cu cm and framing rates of 40 Hz with full modulation depth. The image processing operations that have been achieved using the internal processing mode of the MSLM include contrast reversal, contrast enhancement, edge enhancement, image addition and subtraction, analog and digital intensity thresholding, and binary level logic operations such as AND, OR, EXCLUSIVE OR, and NOR.

Warde, C.↗

Breadboard stellar tracker system test report, volume 1

The performance of a star tracker equipped with a focal plane detector was evaluated. The CID board is an array of 256 x 256 pixels which are 20 x 20 micrometers in dimension. The tracker used for test was a breadboard tracker system developed by BASD. Unique acquisition and tracking algorithms are employed to enhance performance. A pattern recognition process is used to test for proper image spread function and to avoid false acquisition on noise. A very linear, high gain, interpixel transfer function is derived for interpolating star position. The lens used in the tracker has an EFL of 100 mm. The tracker has an FOV of 2.93 degrees resulting in a pixel angular subtense of 41.253 arc sec in each axis. The test procedure used for the program presented a star to the tracker in a circular pattern of positions; the pattern was formed by projecting a simulated star through a rotatable deviation wedge. Further tests determined readout noise, Noise Equivalent Displacement during track, and spatial noise during acquisition by taking related data and reducing it.

Kollodge, J. C.↗

The design and evaluation of superconducting connectors

The development of a superconducting connector for superconducting circuits on space flights is described. It is proposed that such connectors be used between the superconducting readout loop and the SQUID magnetometer in the Gravity Probe B experiment. Two types of connectors were developed. One type employs gold plated niobium wires making pressure connections to gold plated niobium pads. Lead-plated beryllium-copper spring contacts can replace the niobium wires. The other type is a rigid solder or weld connection between the niobium wires and the niobium pads. A description of the methods used to produce these connectors is given and their performance analyzed.

Payne, J. E.↗

A tactual display aid for primary flight training

A means of flight instruction is discussed. In addition to verbal assistance, control feedback was continously presented via a nonvisual means utilizing touch. A kinesthetic-tactile (KT) display was used as a readout and tracking device for a computer generated signal of desired angle of attack during the approach and landing. Airspeed and glide path information was presented via KT or visual heads up display techniques. Performance with the heads up display of pitch information was shown to be significantly better than performance with the KT pitch display. Testing without the displays showed that novice pilots who had received tactile pitch error information performed both pitch and throttle control tasks significantly better than those who had received the same information from the visual heads up display of pitch during the test series of approaches to landing.

Gilson, R. D.↗