Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPORIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Validation of MIPAS IMK-IAA Temperature, Water Vapor, and Ozone Profiles with MOHAVE-2009 Campaign Measurements

MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK) and CSIC, Instituto de Astrofısica de Andalucıa (IAA) and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infrared (FTIR) spectrometers. For MIPAS temperatures (version V4O_T_204), no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203) is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause), but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202) has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution. No further significant biases have been detected. Cross-comparison to co-located observations of other satellite instruments (Aura/MLS, ACE-FTS, AIRS) is provided as well.

MIPAS validation↗

Contrasting Effects of Central Pacific and Eastern Pacific El Nino on Stratospheric Water Vapor

Targeted experiments with a comprehensive chemistry-climate model are used to demonstrate that seasonality and the location of the peak warming of sea surface temperatures dictate the response of stratospheric water vapor to El Nino. In spring, El Nino events in which sea surface temperature anomalies peak in the eastern Pacific lead to a warming at the tropopause above the warm pool region, and subsequently to more stratospheric water vapor (consistent with previous work). However, in fall and in early winter, and also during El Nino events in which the sea surface temperature anomaly is found mainly in the central Pacific, the response is qualitatively different: temperature changes in the warm pool region are nonuniform and less water vapor enters the stratosphere. The difference in water vapor in the lower stratosphere between the two variants of El Nino approaches 0.3 ppmv, while the difference between the winter and spring responses exceeds 0.5 ppmv.

water vapor↗

Demonstration of Multilayer Insulation, Vapor Cooling of Structure, and Mass Gauging for Large Scale Upper Stages: Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) Final Report

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The hardware consists of a 4 meter diameter stainless steel tank, structural skirts supporting the tank in the aft direction, and an aluminum forward skirt with vapor cooling channels bolted to it. The initial testing of the SHIIVER hardware was with liquid hydrogen and liquid nitrogen (as a substitute fluid for liquid oxygen and liquid methane) and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full with no MLI on the domes. It reduced the heat load to the tank by approximately 10%, but the boil-off was essentially unchanged at 50% full whether or not vapor cooling was operational with MLI on the domes. The MLI reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment and profile envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed as a result of acoustic testing. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads.

SHIIVER↗

Review of Vapor Compression Refrigeration in Microgravity Environments

Using a vapor compression cycle for cooling in microgravity environments was already suggested in the 1970s to leverage the high coefficient of performance. Since then, only a few systems have operated in microgravity with scarce documentation of these flights. The lack of measured data and detailed documentation makes identifying the necessary next steps difficult for researchers entering the field of refrigeration in space. This paper provides a review of available literature for vapor compression systems flown in microgravity by outlining the history of vapor compression devices in space and presenting performance data. Moreover, gaps in the literature are highlighted and open questions are posed based on the reviewed material. Next steps of research are suggested to support and ultimately achieve reliable vapor compression refrigeration in space. Calculating equivalent masses for a fair comparison of different microgravity cooling technologies is proposed by capturing both energy consumption and used volume.

Vapor compression↗

Equivalent Mass Benefits from Employing Vapor Compression Refrigeration on Spacecraft

Thermoelectric cooling, reversed Brayton cycles and Stirling cycle devices are common cooling technologies employed on spacecraft where temperatures below the radiator temperature are needed. Although used less often in microgravity, vapor compression refrigeration was proposed for microgravity applications as early as the 1970s. Researchers proposed the vapor compression cycle over other cooling technologies for its superior energy efficiency in the typical refrigerator/freezer and air-conditioning temperature range. The higher energy efficiency should alleviate the mass penalty of the thermal system, conceivably both for satellites and manned spacecraft. Despite numerous propositions, the literature lacks a discussion of the absolute equivalent mass benefit achievable and the value of it relative to the total mass of the thermal system of the spacecraft or the spacecraft itself. This paper presents the equivalent mass benefits of employing a vapor compression system over other cooling technologies using a mass penalty factor for power consumption. Additionally, a prototype vapor compression cooler sized to fit into an ISS locker is presented.

refrigerator↗

Possible Role of Mixing on Water Vapor and Ozone Anomalies During RF05

We investigate the possible role of mixing on the observed variations in water vapor and ozone anomalies during DCOTSS 29 July 2021 flight. Preliminary results indicate that enhanced water vapor is more often associated with enhanced ozone, opposite of what one might expect during convective plume encounters. We use the turbulence eddy dissipation rate as a proxy of mixing to show that when water vapor is significantly enhanced (> 30 ppmv), water vapor anomalies are negatively correlated with mixing strength: strong turbulence and large mixing are associated with relatively dry air. The mechanism behind this relationship as well as the origins of the observed turbulence and mixing will be investigate in the figure.

Mixing↗

Convective Impact on the Global Lower Stratospheric Water Vapor Budget

Water vapor in the stratosphere is primarily controlled by temperatures in the tropical upper troposphere and lower stratosphere. However, the direct impact of deep convection on the global lower stratospheric water vapor budget is still an actively debated issue. Two complementary modeling approaches are used to investigate the convective impact in boreal winter and summer. Convective influence is diagnosed by tracing trajectories through convective cloud top altitude fields derived from global rainfall and brightness temperature data. Backward trajectory model simulations coupled with a detailed treatment of cloud microphysical processes indicate that convection moistens the global lower stratosphere by approximately 0.3 ppmv in boreal winter and summer 2010. The diurnal peak in convection is responsible for about half of the total convective moistening during winter and nearly all of the convective moistening during summer. Deep convective clouds overshooting the tropopause have relatively minor effect on global lower stratospheric water vapor. A forward trajectory model coupled with a simplified cloud module is used to estimate the relative magnitude of the interannual variability of the convective impact. Combining the results from the two models, we find that the convective impact on the global lower stratospheric water vapor during 2006-2016 is approximately 0.3 ppmv with year-to-year variations of up to 0.1 ppmv. An important mechanism of convective hydration of the lower stratosphere is via the detrainment of saturated air and ice into the tropical uppermost troposphere and the subsequent upward transport of some of these moist air parcels across relatively warm and subsaturated tropopause.

CONVECTION↗

Observing and Projecting the Lasting Fate of the Hunga Eruption on Atmospheric Water Vapor and Hydroxyl Radical

On 15th Jan. 2022 the submarine Hunga volcano erupted injecting approximately 0.5 Tg of sulfur dioxide into the stratosphere, but more significantly added 150-170 Tg of water vapor to the stratospheric background (over a 10% perturbation) in a matter of several hours. The sulfur dioxide rapidly converted to sulfate aerosol and along with water vapor, was transported around the Southern Hemisphere sub-tropics into midlatitudes and beyond with some transport into the Northern Hemisphere. With a much longer lifetime than sulfate aerosol, measurable water vapor mass anomalies have persisted with only small losses over more than 2 years since the eruption and are likely to continue above background for the remainder of the decade. Satellite measurements from limb and nadir viewing observing instruments provide the information needed to reasonably initialize the Hunga eruption in the Goddard Earth Observing System (GEOS) model using the “replay” framework coupled to the Global Modeling Initiative (GMI) stratosphere-troposphere chemical mechanism for the recent past and have continued the simulations into the future with the free running chemistry climate model (CCM). Using a number of model ensemble members together with the satellite observations, we quantify how the Hunga eruption is perturbing atmospheric composition and climate and projecting the influences to come as the enhanced water vapor continues in the stratosphere with only very slow removal mechanisms. Modeling suggests that the water rich eruption enhanced stratospheric hydroxyl radiacal (OH) and is supported by the speed of the observed conversion of SO2 into sulfate aerosol. These simulations also suggest a significant reduction in tropospheric OH over the mid-high latitude Southern Hemisphere, which has implications for numerous species that are impacted by this radical. The Hunga eruption provides a useful test of chemistry climate models and an opportunity for observation-based process understanding and in making new connections.

Hunga volcano↗

XeF2 vapor phase silicon etch used in the fabrication of movable SOI structures.

Vapor phase XeF{sub 2} has been used in the fabrication of various types of devices including MEMS, resonators, RF switches, and micro-fluidics, and for wafer level packaging. In this presentation we demonstrate the use of XeF{sub 2} Si etch in conjunction with deep reactive ion etch (DRIE) to release single crystal Si structures on Silicon On Insulator (SOI) wafers. XeF{sub 2} vapor phase etching is conducive to the release of movable SOI structures due to the isotropy of the etch, the high etch selectivity to silicon dioxide (SiO{sub 2}) and fluorocarbon (FC) polymer etch masks, and the ability to undercut large structures at high rates. Also, since XeF{sub 2} etching is a vapor phase process, stiction problems often associated with wet chemical release processes are avoided. Monolithic single crystal Si features were fabricated by etching continuous trenches in the device layer of an SOI wafer using a DRIE process optimized to stop on the buried SiO{sub 2}. The buried SiO{sub 2} was then etched to handle Si using an anisotropic plasma etch process. The sidewalls of the device Si features were then protected with a conformal passivation layer of either FC polymer or SiO{sub 2}. FC polymer was deposited from C4F8 gas precursor in an inductively coupled plasma reactor, and SiO{sub 2} was deposited by plasma enhanced chemical vapor deposition (PECVD). A relatively high ion energy, directional reactive ion etch (RIE) plasma was used to remove the passivation film on surfaces normal to the direction of the ions while leaving the sidewall passivation intact. After the bottom of the trench was cleared to the underlying Si handle wafer, XeF{sub 2} was used to isotropically etch the handle Si, thus undercutting and releasing the features patterned in the device Si layer. The released device Si structures were not etched by the XeF{sub 2} due to protection from the top SiO{sub 2} mask, sidewall passivation, and the buried SiO{sub 2} layer. Optimization of the XeF{sub 2} process and the sidewall passivation layers will be discussed. The advantages of releasing SOI devices with XeF{sub 2} include avoiding stiction, maintaining the integrity of the buried SiO{sub 2}, and simplifying the fabrication flow for thermally actuated devices.

36 MATERIALS SCIENCE↗

The Influence of Water Vapor on the Electrochemical Shift of an Ionic Liquid Measured by Ambient Pressure X-ray Photoelectron Spectroscopy

Ionic liquids (ILs) are considered to be one of the steppingstones to fabricate next generation electrochemical devices given their unique physical and chemical properties. The addition of water to ILs significantly impact electrochemical related properties including viscosity, density, conductivity, and electrochemical window. Here, we utilize ambient pressure X-ray photoelectron spectroscopy (APXPS) to examine the impact of water on values of the electrochemical shift (S), which is determined by measuring changes in binding energy shifts as a function of an external bias. APXPS spectra of C 1s, O 1s and N 1s regions are examined for the IL 1-butyl-3-methylimidazolium acetate, [C 4 mim][OAc], at the IL/gas interface as a function of both water vapor pressure and external bias. Results reveal that in the absence of water vapor there is an IL ohmic drop between the working electrode and quasi reference electrode, giving rise to chemical specific S values of less than one. Upon introducing water vapor, S values approach one as a function of increasing water vapor pressure, indicating a decrease in the IL ohmic drop as the IL/water mixture becomes more conductive and the potential drop is driven by the electric double layer at the electrode/IL interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water vapor exposure chamber for constant humidity and hydrogen and oxygen stable isotope composition

Rationale: Water vapor exposure experiments have applications for studying water physisorption and chemisorption hydration and hydroxylation reactions on a wide variety of material surfaces. The stable isotopes of hydrogen and oxygen in the water molecule are useful tracers of water exchange mechanisms and/or rates in such vapor exposure experiments. Methods: We designed and built a humidity chamber system that uses membrane-mediated liquid–vapor exchange of water followed by mixing with dry air to control the relative humidity of air and its δ 2 H and δ 18 O isotopic composition. We tested the stability and precision of the humidity and its isotopic composition on hourly to 90-day timescales. Results: The humidity chamber design reported here is capable of providing relative humidity control to within ±1%, and consistent δ 2 H and δ 18 O values of the water vapor that are similar to our cavity ringdown spectroscopy (CRDS) measurement precision (δ2H vap ± 0.7‰ and δ18O vap ± 0.24‰). We quantify the isotopic enrichment effects of Rayleigh distillation in the system and provide information on water reservoir sizes large enough to buffer isotopic enrichment effects to within measurement precision. Conclusions: The humidity chamber design reported here provides a means to create constant δ2H and δ18O values over the course of an exposure experiment. The design has applications to a wide range of studies of water sorption on material surfaces from foods and pharmaceuticals to geological materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of vapor-liquid interactions in condensing ejectors

Ejectors are compact mechanical devices that utilize the expansion of a high-pressure primary fluid to entrain and compress a low-pressure secondary fluid by means of momentum transfer between the two streams of fluid. Condensing ejectors feature both momentum and heat transfer through the interaction between the vapor and liquid streams. The goal of this paper is to develop and validate a one-dimensional slug flow model to simulate the vapor–liquid interactions in two types of condensing ejectors – one with primary liquid and secondary vapor flows (Type I), and the other with primary vapor and secondary liquid flows (Type II). Control volume analysis of the mass, momentum, and energy balance in each phase and across the interface was conducted for the ejectors. The slug flow models for both types of ejectors are validated with published results in the literature. The friction coefficient on the inner wall of the ejectors and the interfacial heat transfer coefficient are identified as controlling parameters for the ejector performance in terms of pressure and temperature distributions along the axis. The detailed parametric study shows that the liquid inlet velocity and mixing tube diameter have a significant impact on the performance of the Type I ejectors, and the performance of the Type II ejectors is mainly controlled by the secondary liquid flow inlet temperature.

42 ENGINEERING↗

Recent trends and variability of temperature and atmospheric water vapor over South Asia

This study examines the recent trends and variability of temperature and atmospheric water vapor over South Asia during the summer monsoon season from 1970 to 2022. We employ gridded reanalysis and observational datasets to assess the trends and variability in surface temperature and further investigate the associated physical processes. Our results show that the surface temperature over South Asia has increased by 0.5 °C per decade. Notably, we find a statistically significant major transition in the surface temperature series in 1995, such that 1970–1994 (1995–2022) is associated with anomalous cooling (anomalous warming). Since 1995, not only have the temporal variations in regional surface temperature, atmospheric water vapor, and clear-sky downward longwave radiation been synchronous at interannual scales, but their largest spatial variations have been located mainly over the same region. A diagnosis of the atmospheric moisture budget reveals that the observed changes in water vapor convergence over South Asia are dominated by changes in mean circulation dynamics, while the change in thermodynamics is relatively small. The enhancement of the Somali low-level jet may contribute to increased water vapor in South Asia by modulating low-level circulations.

Atmospheric circulations↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Experimental Study of the Solubility of Rare Earth Chloride Salts (La, Nd, Er) in HCl Bearing Water Vapor from 350 – 425 °C

In this work, the solubilities of the rare earth chlorides REECl 3 , where REE = (La, Nd, Er), were measured in HCl bearing water vapor from 350 – 425°C with water partial pressures ranging from 8 – 170 bar. Solubility data were fit to the Pitzer-Pabalan quasi-chemical model in order to extract thermodynamic parameters for the formation of the gaseous REE-chloride-water clusters REECl 3 (H 2 O) n . The data show that the solubility of the REE chlorides are orders of magnitude higher than salts such as NaCl or CuCl at low water fugacities, despite their sublimation energies being substantially higher. This enhanced solubility is likely due to the high enthalpy associated with binding a single water molecule to form the species REECl 3 (H 2 O), with derived enthalpies ranging from –378 to –465 kJ/mol. Addition of further water molecules to form higher order clusters (n > 1) involves enthalpy changes of ~ -20 kJ/mol, and are in effect thermodynamically suppressed over the temperature range 350 – 425°C. Despite the enhanced solubility of small REECl 3 water clusters, simulations of boiling processes demonstrate that the REE show highly conservative behavior, partitioning strongly into the dense aqueous phase. Not surprisingly, the presence of phosphates in the system makes this effect even more pronounced, completely immobilizing the REE. This would reduce transport in both the vapor and aqueous phase to negligible levels. However, we suggest that vapor phase transport of the REE may play a significant role in systems having a relatively low partial pressure of water (below the saturation point), where the relatively high stability of the first hydrated REE chloride clusters (REECl 3 (H 2 O) and REECl 3 (H 2 O) 2 ) will give a preference for gas transport of the REE relative to other elements. This can likely happen in systems involving a gas/melt exchange in fumarolic exhalations, where water vapor discharges at relatively low (close to atmospheric) pressures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical model of dielectrophoretic water vapor condensation during multiphase flow of electrically charged water droplets in air

Water droplet growth in air, influenced by vapor diffusion and electrical charging, has significant implications for indoor air quality, cloud formation, and aerosol dynamics. Here, this study presents a comprehensive theoretical model that describes the growth dynamics of electrically charged water droplets under external electric fields, incorporating diffusion, electrostatic, and dielectrophoretic forces to enhance understanding and practical applications in air dehumidification and environmental control. A theoretical model was established to analyze the growth dynamics of the charged water droplets. The approach extended the thermodynamic framework of the Modified Kelvin-Thomson equation by integrating electrostatic and dielectrophoretic effects, enabling a comprehensive evaluation of vapor concentration near the surface of charged droplets. A sensitivity analysis was performed to assess the roles of droplet size, electric field intensity, surface charge, and vapor concentration on condensation rates. The study progressed beyond the classical diffusion-limited growth of neutral droplets, addressing the behavior of charged droplets in electrohydrodynamic environments. The model highlighted the significance of dielectrophoretic drift flux for dipolar vapor molecules, especially in micron-sized droplets ranging from 10 to 100 µm. Findings demonstrated that, for smaller droplets subjected to elevated electrical charge, average growth rates varied from 0.3 to 1.6 µm/s if the air relative humidity increased from 50 to 100 %. Analytical results are corroborated by numerical simulations, which exhibited strong concordance, thereby validating the proposed theoretical approach. This research introduced an innovative and scalable analytical methodology for electric field-enhanced droplet growth, offering valuable insights into the advancement of energy-efficient air dehumidification, water desalination, and atmospheric water harvesting technologies.

42 ENGINEERING↗

Physics of lithium bromide (LiBr) solution dewatering through vapor venting membranes

The physics of water desorption from a lithium bromide (LiBr) solution flow through an array of microchannels capped by a porous membrane is studied. The membrane allows the vapor to exit the flow and retains the liquid. Effects of different parameters such as wall temperature, solution and vapor pressures, and solution mass flux on the desorption rate were studied. Two different mechanisms of desorption are analyzed. These mechanisms consisted of: (1) direct diffusion of water molecules out of the solution and their subsequent flow through the membrane and (2) formation of water vapor bubbles within the solution and their venting through the membrane. Direct diffusion was the dominant desorption mode at low surface temperatures and its magnitude was directly related to the vapor pressure, the solution concentration, and the heated wall temperature. Desorption at the boiling regime was predominantly controlled by the solution flow pressure and mass flux. Microscale visualization studies suggested that at a critical mass flux, some bubbles are carried out of the desorber through the solution microchannels rather than being vented through the membrane. Overall, an order of magnitude higher desorption rate compare to a previous study on a membrane-based desorber was achieved. Published by Elsevier Ltd.

Isfahani, RN↗

Effect of H 2 O Vapor on the Adsorption and Desorption Behavior of CO 2 in a Solid Amine Sorbent

The effect of H 2 O vapor on the adsorption and desorption of CO 2 and vice versa, both on a commercially viable solid amine sorbent (SAS), were studied using a thermogravimetric analyzer at constant temperature. The SAS was prepared by physically immobilizing PEI (M n 423) in a porous silica (CARiACT G10). Studies were carried out at two concentrations of CO 2 (2 vol % in N 2 and 100 vol %), one concentration of H 2 O vapor (2 vol %), and four temperatures (40, 60, 80, and 100 °C). The results revealed three separate and identifiable mechanisms or processes taking place on the SAS, i.e., the individual adsorption of CO 2 or H 2 O and the coadsorption of H 2 O and CO 2 . The individual adsorption of either CO 2 or H 2 O was noncompetitive or completely independent of each other thermodynamically for both concentrations of CO2 and all four temperatures. In addition, the individual adsorption of CO 2 was fully reversible, while the individual adsorption of H 2 O was only partially reversible. The coadsorption of CO 2 and H 2 O was exothermic, with either irreversible or very slow desorption kinetics. Coadsorption was observed appreciably only at 60 and 40 °C at both CO 2 concentrations and only very slightly at 80 °C and 2 vol % CO 2 . It was not observed at 100 °C at either CO 2 concentration or at 80 °C at 100 vol % CO 2 . The influence of CO 2 or H 2 O on the kinetics of any of these processes was revealed only at the two lower temperatures, with H 2 O having a positive influence on the desorption kinetics of CO 2 at 40 °C and with CO 2 , if adsorbed previously, having a negative influence on the adsorption kinetics of both H 2 O and the coadsorption of both CO 2 and H 2 O at both 60 and 40 °C. When these effects existed, they were not that significant, at least not at 2 vol % H 2 O vapor. Finally, these results thus indicated that the effect of H 2 O vapor in the feed of a CO 2 stream does not have to be accounted for mechanistically when modeling a cycle adsorption process based on this commercially viable SAS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗