Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Support of the Laboratory for Terrestrial Physics for Dynamics of the Solid Earth (DOSE)

This final report summarizes the accomplishments during the contract period. Under the contract NVI, Inc. provided support to the VLBI group at NASA's Goddard Space Flight Center. The contract covered a period of approximately eight years during which geodetic and astrometric VLBI evolved through several major changes. This report is divided into four sections which correspond to major task areas in the contract: A) Coordination and Scheduling, B) Field System, C) Station Support, and D) Analysis and Research and Development.

Vandenberg, Nancy R.↗

Support for the Laboratory for Terrestrial Physics for Dynamics of the Solid Earth (DOSE)

This final report summarizes the accomplishments during the contract period. Under the contract NVI, Inc. provided support to the VLBI group at NASA's Goddard Space Flight Center. The contract covered a period of approximately eight years during which geodetic and astrometric VLBI evolved through several major changes. This report is divided into four sections which correspond to major task areas in the contract: A) Coordination and Scheduling, B) Field System, C) Station Support, and D) Analysis and Research and Development.

Ma, C.↗

Support of the Laboratory for Terrestrial Physics for Dynamics of the Solid Earth (DOSE)

This final report summarizes the accomplishments during the contract period. Under the contract Nepal, Inc. provided support to the VLBI group at NASA's Goddard Space Flight Center. The contract covered a period of approximately eight years during high geodetic and astrometric VLBI evolved through several major changes. This report is divided into five sections that correspond to major task areas in the contract: A) Coordination rid Scheduling, B) Field System, CN Station Support, D) Analysis and Research and Development, and E) Computer Support.

Vandenberg, N. R.↗

Total Ionizing Dose Effects in MOS Oxides and Devices

The development of military and space electronics technology has traditionally been heavily influenced by the commercial semiconductor industry. The development of MOS technology, and particularly CMOS technology, as dominant commercial technologies has occurred entirely within the lifetime of the NSREC. For this reason, it is not surprising that the study of radiation interactions with MOS materials, devices and circuits has been a major theme of this conference for most of its history. The basic radiation problem in a MOS transistor is illustrated. The application of an appropriate gate voltage causes a conducting channel to form between the source and drain, so that current flows when the device is turned on. In Fig. lb, the effect of ionizing radiation is illustrated. Radiation-induced trapped charge has built up in the gate oxide, which causes a shift in the threshold voltage (that is, a change in the voltage which must be applied to turn the device on). If this shift is large enough, the device cannot be turned off, even at zero volts applied, and the device is said to have failed by going depletion mode.

Oldham, Timothy R.↗

Solar Particle Events Observed by the Odyssey MARIE Instrument at Mars: Dose and Model Calculations

One of the primary concerns prior to human exploration of Mars is the need to accurately characterize the charged particle radiation environment both for the surface stay, and for the transit period to and from the planet. The Odyssey spacecraft, currently in Mars orbit includes a charged particle radiation detector, MARIE, which can measure particle fluxes with energies above approx. 30 MeV and charges between 1 and 10. Two classes of particles are of particular interest: the Galactic Cosmic Rays, (GCR), and those charged particles associated with Solar Particle Events, (SPE). The GCR are present continuously throughout the solar activity cycle, and their numbers vary inversely with the level of solar activity. They are characteristically more energetic than those particles originating from solar activity, and hence less influences by the solar magnetic field.

Cleghorn, T. F.↗

Long term effects of low doses of 56Fe ions on the brain and retina of the mouse: ultrastructural and behavioral studies

Eight month old male C57BL6 mice were exposed without anesthesia to whole-body irradiation in circular holders. The mice were tested for behavioral decrements after 0.5 and 50 rads of Fe particle irradiation at 6 and 12 months post irradiation to obtain long term results. A standard maze was used and the animals were timed for completion thereof. A string test also was administered to the mice, testing their ability to grasp and move along a string to safety. The results from animals exposed to 50 rads were significantly different from [correction of fron] control results to p = < .001 in both systems of testing. The hippocampus (believed to be the location of environmental interaction in the brain) and the retina were examined for ultrastructural changes. The ultrastructural changes were similar to those we found in our Cosmos 782, 936 and in our Argon experiments. The mouse data indicate that iron particles were able to induce long term changes in the central nervous system which lead to behavioral impairment.

NASA Program Space Medicine↗

Dose limits for astronauts

Radiation exposures to individuals in space can greatly exceed natural radiation exposure on Earth and possibly normal occupational radiation exposures as well. Consequently, procedures limiting exposures would be necessary. Limitations were proposed by the Radiobiological Advisory Panel of the National Academy of Sciences/National Research Council in 1970. This panel recommended short-term limits to avoid deterministic effects and a single career limit (of 4 Sv) based on a doubling of the cancer risk in men aged 35 to 55. Later, when risk estimates for cancer had increased and were recognized to be age and sex dependent, the NCRP, in Report No. 98 in 1989, recommended a range of career limits based on age and sex from 1 to 4 Sv. NCRP is again in the process of revising recommendations for astronaut exposure, partly because risk estimates have increased further and partly to recognize trends in limiting radiation exposure occupationally on the ground. The result of these considerations is likely to be similar short-term limits for deterministic effects but modified career limits.

Review↗

Total Dose Effects and Hardness Assurance for Optocouplers

The operation and efficiency of optocouplers depend on a number of different factors, and the way that these factors are degraded by radiation must be properly understood in order to apply these devices in space systems.

optocouplers optocoupler efficiency LED degradatio↗

Total Dose Effects in Conventional Bipolar Transistors

This paper examines various factors in bipolar device construction and design, and discusses their impact on radiation hardness. The intent of the paper is to improve understanding of the underlying mechanisms for practical devices without special test structures, and to provide (1) guidance in ways to select transistor designs that are more resistant to radiation damage, and (2) methods to estimate the maximum amount of damage that might be expected from a basic transistor design. The latter factor is extremely important in assessing the risk that future lots of devices will be substantially below design limits, which are usually based on test data for older devices.

Bipolar Devices Cassini Ionizing radiation effects↗

Total Ionizing Dose Effects in 12-Bit Successive-Approximation Analog-To-Digital Converters

Analog-to-digital (A/D) converters are critical components in many space and military systems, and there have been numerous advances in A/D converter technology that have increased the resolution and conversion time. The increased performance is due to two factors: (1) advances in circuit design and complexity, which have increased the number of components and the integration density; and (2) new process technologies, such as BiCMOS, which provide better performance, cost, and smaller size in mixed-signal circuits. High-speed A/D converters, with conversion rates above 1 MHz, present a challenge to circuit designers and test engineers. Their complex architectures and high-performance specifications result in numerous possible failure modes when they are subjected to ionizing radiation. The dominant failure mode may depend on the specific application because the fundamental effects on MOS and bipolar transistors are strongly affected by bias conditions.

Lee, C. I.↗

Probabilistic Risk Model for Organ Doses and Acute Health Effects of Astronauts on Lunar Missions

Exposure to large solar particle events (SPEs) is a major concern during EVAs on the lunar surface and in Earth-to-Lunar transit. 15% of crew times may be on EVA with minimal radiation shielding. Therefore, an accurate assessment of SPE occurrence probability is required for the mission planning by NASA. We apply probabilistic risk assessment (PRA) for radiation protection of crews and optimization of lunar mission planning.

Kim, Myung-Hee Y.↗

Dose-Response Evaluation of Braslet-M Occlusion Cuffs

Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current non-imaging calibration techniques.

Ebert, Douglas↗

Simulation and Measurement of Absorbed Dose from 137 Cs Gammas Using a Si Timepix Detector

The TimePix readout chip is a hybrid pixel detector with over 65k independent pixel elements. Each pixel contains its own circuitry for charge collection, counting logic, and readout. When coupled with a Silicon detector layer, the Timepix chip is capable of measuring the charge, and thus energy, deposited in the Silicon. Measurements using a NIST traceable 137Cs gamma source have been made at Johnson Space Center using such a Si Timepix detector, and this data is compared to simulations of energy deposition in the Si layer carried out using FLUKA.

Stoffle, Nicholas↗