Search NASASearch

SEARCH · Search NASA

Results for “thermal insulation materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,797 records · Page 32

Formation of Bimetallic Nanoparticles via Exsolution Using a Reducible Metal Oxide Capping Layer

Bimetallic nanoparticles are promising catalysts that can improve performance in heterogeneous catalysis and solid-state electrochemistry. Exsolution is a useful method for forming such nanoparticles; however, it is limited by the elements present within the host oxide lattice. Here, in this work, we develop and demonstrate a strategy to form bimetallic particles from La 0.5 Sr 0.5 Ti 0.94 Ni 0.06 O 3 (LSTN) exsolution and using a reducible SnO 2 capping layer, expanding the range of elements available for bimetallic nanoparticle formation. Using this capping layer strategy, we formed nickel–tin (Ni 0 –Sn 0 ) bimetallic nanoparticles via exsolution. We used in situ near-ambient pressure X-ray photoelectron spectroscopy to monitor surface chemical changes during exsolution, showing that first, SnO 2 volatilized. This SnO 2 loss exposed the perovskite surface of LSTN to reducing conditions, which induced Ni exsolution, and compounded with SnO 2 reduction led to the formation of bimetallic Ni 0 –Sn 0 particles. To evaluate the associated microstructural evolution, we measured grazing incidence small-angle X-ray scattering (GISAXS), which confirmed the loss of the SnO 2 capping layer, and scattering simulations suggested the formation of bimetallic particles. We confirmed the bimetallic nanoparticle composition and morphology by Auger spectroscopy and scanning transmission electron microscopy. The resulting bimetallic nanoparticles were smaller and more thermally stable than the monometallic Ni counterparts on LSTN. This capping layer and exsolution approach allow synthesizing multimetallic nanoparticles and can be applied to other reducible metal oxides and perovskite hosts, broadening the compositional space for advanced catalytic materials.

36 MATERIALS SCIENCE

The Roman Space Telescope Optical System: Status, Test, and Verification Update

The Nancy Grace Roman Space Telescope (“Roman”) is NASA’s next flagship observatory. Launching in 2026, Roman will explore the nature of dark energy as well as expand the census of exoplanets in our galaxy via microlensing. Roman’s large field of view, agile survey capabilities, and excellent stability enable these scientific objectives, yet present unique challenges for the design, test, and verification of its optical system. Roman recently completed a comprehensive thermal vacuum test of the Spacecraft bus + Integrated Payload Assembly (SCIPA), followed by integrating the Outer Barrel Assembly (OBA), Solar Array Sunshield (SASS), and Deployable Aperture Cover (DAC) with SCIPA to complete the Observatory. This paper will present an overview of the thermal vacuum optical testing as well as a status of the optical system performance and verification.

Matthew Bolcar

Chiral edge state control of thermoelectric effects

Thermoelectric responses in two-dimensional electron gases subjected to magnetic fields have the potential to provide unique information about quasiparticle statistics. In this study, we show that chiral edge states play a key role in thermoelectric Hall bar measurements by completely controlling the direction of the internal thermal gradient. To this end, we perform measurements of the magnetothermoelectric responses of cadmium arsenide quantum wells. The magnetothermoelectric responses in the quantum Hall regime agree with theoretical predictions if one considers the role of chiral edge states, which flow in opposite directions on either side of the Hall bar and establish an internal temperature gradient that is perpendicular to the externally applied thermal gradient. We show that the results are self-consistent within this picture under different measurement conditions. We discuss potential applications of the findings, such as in nanoscale control of local temperature gradients and thermoelectric effects along with the characterization of other topological systems with chiral edges states.

Science & Technology - Other Topics

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

Medical Aspects of Gemini Extravehicular Activities

The medical aspects of Gemini extravehicular activities are principally concerned with the physiological responses to high workloads, high thermal stresses, and low fatigue tolerance. Analysis of physiological instrumentation data. from extravehicular flights and training operations contributed significantly to the understanding of extra-vehicular workloads and the means of controlling these workloads.

G Fred Kelly

Bypass heat exchanger configuration to reroute core flow

A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.

Terwilliger, Neil

Enabling Mission Flexibility to Battery Driven Deep Space Endeavors With Generalized Battery-Health-Monitoring Using Physics-Based and Data-Driven Reduced-Order Models

The needs and requirements for an electrochemical energy storage for deep space exploration is well explored. It is often understood that different mission sites and environmental conditions require different battery chemistries or technologies. Additionally, various engineering solutions are deployed to overcome specific chemical challenges. One often overlooked need is the “health” monitoring of an electrochemical storage system. The term generalized health monitoring, as envisioned in this work, refers to the monitoring of various aspects such as electrode health, electrolyte health, reaction pathway health, cooling system health, sensor health, and BMS health [1]. Generalized health monitoring allows mission leads, engineers, and scientists to incorporate flexibility in mission designs, make on-the-fly mission changes, and extend the duration of science missions. Moreover, it enables automation and data-driven decision-making without compromising safety and performance. Recently, our group developed a hierarchy of thermal reduced-order models (TROM) by combining a physics-based modeling approach and data-driven model reduction techniques applied to flight data [2]. The resulting TROMs were found to be not only accurate but also identifiable from the flight data. Consequently, the coefficient of variance of the model parameters is small over the course of hundreds of flights, allowing for monitoring the parameter evolution trajectories as the battery ages and degrades. These parameters constitute the metrics of the generalized health of a battery. Monitoring their evolution allows such models to be used for anomaly detection and prognostics, improving early detection of abnormal behavior and thus enabling timely maintenance, longer battery life, and enhanced battery safety. For this presentation, the practicality of the thermal model will be validated on a pack of 14cells under various topology configurations such as 1S14P, 2P7S, 7S2P, and 1P14S. It is well known that manufacturing and non-uniform aging lead to variability in the performance of a cell, which is exacerbated by cell balancing during active load. Additionally, in extreme scenarios, the paramount objective is to complete the mission, regardless of the stresses on the battery. Topology-induced balancing issues further stress the battery. The goal of this study is to determine if the noise (identifiability) in the reduced-order thermal model parameters is sensitive to topology, cell spacing, cooling strategy, and manufacturing or age variability. The variability in cells is considered by assuming a multimodal distribution for microscopic parameters of a cell (such as porosity, tortuosity, reaction kinetics, volumetric thermal conductivity, and volumetric heat capacity). The compounded effect of manufacturing variability, topological selection, cooling strategies, and cell balancing ages each cell in a battery differently. The study aims to clarify whether the challenge in extracting maximum information depends on the minimum number of sensors or models used for data extraction.

Automation

Characterizing and modeling the mechanical behavior of an anion exchange membrane for carbon capture applications

A new direct air capture (DAC) technology uses a moisture swing (MS) process with anion exchange membranes, potentially offering a more energy-efficient way to remove CO₂ from the air. In this MS process, the membrane absorbs CO₂ as it dries and releases it when water is added. Understanding the mechanical behavior of these membranes is essential for improving the design and efficiency of DAC systems and prolonging sorbent lifetime. This study tested one anion exchange membrane, Fumasep’s FAA-3, under mechanical loading and various temperature and humidity conditions to measure its swelling, stiffness, strength, plastic deformation, and stress relaxation. Experimental results were used to identify a mechanical model for FAA-3 that can be used to predict the material’s nonlinear viscous behavior under various loads and environments. Unlike prior studies that assumed linear elastic behavior, this work incorporates humidity-dependent swelling, thermal expansion, and nonlinear viscoelasticity of FAA-3 in both the experiments and the model.

Direct air capture

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277

Electric Propulsion for Manned Missions

Electric propulsion is of interest for manned interplanetary missions, primarily because it offers the potential of delivering and returning relatively large payload fractions from the planets. This can be achieved because of the high specific impulse obtainable when the propellant is accelerated by electrical means rather than thermally, as in chemical and nuclear rockets.

Robert J Denington

The phase diagram of quantum chromodynamics in one dimension on a quantum computer

The quantum chromodynamics (QCD) phase diagram, which reveals the state of strongly interacting matter at different temperatures and densities, is key to answering open questions in physics, ranging from the behaviour of particles in neutron stars to the conditions of the early universe. However, classical simulations of QCD face significant computational barriers, such as the sign problem at finite matter densities. Quantum computing offers a promising solution to overcome these challenges. Here, we take an important step toward exploring the QCD phase diagram with quantum devices by preparing thermal states in one-dimensional non-Abelian gauge theories. We experimentally simulate the thermal states of SU(2) and SU(3) gauge theories at finite densities on a trapped-ion quantum computer using a variational method. This is achieved by introducing two features: Firstly, we add motional ancillae to the existing qubit register to efficiently prepare thermal probability distributions. Secondly, we introduce charge-singlet measurements to enforce colour-neutrality constraints. This work pioneers the quantum simulation of QCD at finite density and temperature for two and three colours, laying the foundation to explore QCD phenomena on quantum platforms.

Quantum information

Exploration Extravehicular Mobility Unit 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert Marsch

Validation of the SINDA/FLUINT Code Using Several Analytical Solutions

The Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA/FLUINT) code has often been used to determine the transient and steady-state response of various thermal and fluid flow networks. While this code is an often used design and analysis tool, the validation of this program has been limited to a few simple studies. For the current study, the SINDA/FLUINT code was compared to four different analytical solutions. The thermal analyzer portion of the code (conduction and radiative heat transfer, SINDA portion) was first compared to two separate solutions. The first comparison examined a semi-infinite slab with a periodic surface temperature boundary condition. Next, a small, uniform temperature object (lumped capacitance) was allowed to radiate to a fixed temperature sink. The fluid portion of the code (FLUINT) was also compared to two different analytical solutions. The first study examined a tank filling process by an ideal gas in which there is both control volume work and heat transfer. The final comparison considered the flow in a pipe joining two infinite reservoirs of pressure. The results of all these studies showed that for the situations examined here, the SINDA/FLUINT code was able to match the results of the analytical solutions.

John R Keller

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Fracture Analysis of Cohesive Zone Models for Modeling Residual Stress Induced Delamination in Composite Structures

A fracture study of coupon-scale composite cylinders with embedded defects was conducted with an objective to assess and validate a modeling approach using two available cohesive material models. The study included experimental and simulation evaluations of initiation of crack growth and progression. Interrupted thermal experiments used acoustic emissions monitoring to identify the onset of crack progression during each cooling interval and ultrasonic scanning provided images of defect growth. Verification, validation, and uncertainty quantification (VVUQ) processes were performed in the assessment of the simulation predicted temperature at which crack propagation begins (quantity of interest). The Sobol sensitivity analysis identified the hoop direction elastic modulus in the carbon fiber reinforced polymer (CFRP) plies as the most influential parameter for simulations using both cohesive models, accounting for at least 70% of the variation in the temperature at crack propagation. The UQ temperature range for the Tvergaard-Hutchinson model was higher (more conservative) than the experimental acoustic measurement indicators of crack progression, while the temperature range for the Thouless-Parmigiani model enveloped the experimental data points for the primary defect size of 0.75 x 1 in. The simulations could not capture the stable crack growth indicated in the experiments. This is likely due to the models’ inability to represent anisotropic fracture toughness attributed to the structure of the orthotropic fiber weave in a woven composite laminate.

42 ENGINEERING

Unraveling interphase-driven failure pathways in LiMn0.6Fe0.4PO4/graphite pouch cells

LiMnxFe1−xPO4 (LMFP) is a promising high-voltage, thermally stable, and earth-abundant cathode material, yet its practical application is limited by interphase instability and Mn dissolution. In this work, we systematically evaluate LiMn0.6Fe0.4PO4/graphite pouch cells using three electrolyte formulations including control carbonate electrolyte, control + 2 wt% vinylene carbonate (VC), and control + 2 wt% VC + 1 wt% 1,3,2-dioxathiolane 2,2-dioxide (DTD), to establish how electrolyte composition governs interphase chemistry and long-term degradation. Electrochemical testing shows that both additives are preferentially reduced prior to ethylene carbonate (EC) during cell formation, generating robust cathode-electrolyte interphase (CEI) and solid-electrolyte interphase (SEI) layers that suppress gas evolution and raise the first-cycle coulombic efficiency to 89.3%. Additionally, the dual-additive electrolyte delivers the most stable performance, retaining over 85% capacity after 600 cycles while minimizing impedance growth under long-term cycling at C/3 and 40 °C. Soft X-ray absorption spectroscopy confirms that VC + DTD effectively suppresses electrolyte oxidation at the cathode surface, and micro-X-ray fluorescence shows substantially reduced Mn dissolution and deposition on the graphite anode. Density functional theory simulations further provided insights into the structural and energetic influences of alkoxide species on the cathode surface, proposing a Mn2+ extraction mechanism. The combined experimental and computational findings establish a mechanistic link between electrolyte composition and interphase evolution, highlighting the effectiveness of electrolyte engineering for extending the operational lifetime of LMFP-based lithium-ion batteries.

Chak, Chanmonirath Michael

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science

Exploration Extravehicular Mobility Unit (xEMU) 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert F Marsch