Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A Multi-Anode Photomultiplier Tube Based Wavelength-Shifting-Fiber Detector for neutron diffraction

The wavelength-shifting (WLS) fiber scintillator neutron detectors were developed for two time-of-flight (TOF) neutron powder diffractometers (POWGEN, VULCAN) at Spallation Neutron Source (SNS). In a recent module (v3.0), however, there are 32 1-inch-diameter photomultiplier tubes (PMTs) which are bulky and expensive. We built a new detector module (v3.1) based on four multi-anode (MA) PMTs, and tested its performance including detection efficiency, count rate capability, spatial resolution, ghosting properties, and gamma-ray sensitivity. The v3.1 module was compared with two prior v3.0 modules, and 3He tube detectors.

Berry, Kevin D↗

Advanced Characterization of Irradiated Fuels and Materials at INL

Advanced characterization of the irradiated fuels and materials is crucial to help understanding the material and fuel property changes under irradiation. Microstructural defect evolution down to nanometer scale could strongly affect the material and fuel performance on macroscale. Radiation-induced material degradation include dimensional instability, hardening and embrittlement, intergranular cracking, radiation-enhanced chemical interaction at the interfaces and breakaway swelling. To mitigate the radiation damage, advanced characterization on irradiated microstructure, microchemistry, micromechanical property and local thermal property is necessary to identify the controlling mechanisms that are responsible to the degradations. This presentation provides a summary of the advanced characterization capabilities at the Irradiation Materials Characterization Laboratory (IMCL), Materials and Fuels Complex (MFC), Idaho National Laboratory (INL). It highlights the recently established capabilities including shield sample preparation area (SSPA), shield confinement cells for two focused ion beam (FIB) systems, a shielded electron probe microanalysis (EPMA), the thermal property microscopy (TPM) along with non-shielded instruments like scanning electron microscopy (SEM), X-ray diffractometer, and transmission electron microscopy (TEM). Some examples on advanced characterizations on irradiated structural materials and fuels will be presented. It demonstrates the power of combining sample preparation of highly radioactive materials with the advanced characterization down to atomic resolutions within one facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solid-state synthesis, characterization and luminescent properties of Eu{sup 3+}-doped gadolinium tungstate and molybdate phosphors: Gd{sub (2-x)}MO{sub 6}:Eu{sub x}{sup 3+} (M=W, Mo)

Red phosphors gadolinium tungstate and molybdate with the formula Gd{sub (2-x)}MO{sub 6}:Eu{sub x}{sup 3+} (M=Mo, W) were successfully synthesized by the solid-state reaction at 900 and 1300 deg. C for 4 h, respectively. The products were characterized by an X-ray powder diffractometer (XRD), TG-DSC, FT-IR, PL, UV-vis and SEM. Room-temperature photoluminescence indicated that the as-prepared Gd{sub (2-x)}MO{sub 6}:Eu{sub x}{sup 3+} (M=Mo, W) had a strong red emission, which is due to the characteristic transitions of Eu{sup 3+} ({sup 5}D{sub 0}{yields}{sup 7}F{sub J}, J=0, 1, 2, 3, 4) for these phosphors. Meanwhile, the {sup 5}D{sub 0}{yields}{sup 7}F{sub 2} is in the dominant position. The emission quantum efficiency of Eu{sup 3+} in the Gd{sub (2-x)}MO{sub 6}:Eu{sub x}{sup 3+} (M=Mo, W) system has been investigated. The XRD results indicate that both Gd{sub 2}WO{sub 6} and Gd{sub 2}MoO{sub 6} belong to the monoclinic system with space group C2/c [A. Bril, G. Blasse, J. Chem. Phys. 45 (1966) 2350-2356] and I2/a [A. Bril, G. Blasse, J. Chem. Phys. 45 (1966) 2350-2356], respectively. SEM images indicate that the shape of Gd{sub 1.96}WO{sub 6}:Eu{sub 0.04}{sup 3+} is aggregated small particles with a mean diameter of about 300 nm, and the shape of Gd{sub 1.96}MoO{sub 6}:Eu{sub 0.04}{sup 3+} is block-like structures. - Graphical abstract: Excellent red phosphors gadolinium tungstate and molybdate with the formula Gd{sub (2-x)}MO{sub 6}:Eu{sub x}{sup 3+} (M = Mo, W) were synthesized by the conventional solid-state reaction at 900 and 1300deg. C for 4 h, respectively. SEM imagines indicate that the morphology of Gd{sub 1.96}WO{sub 6}:Eu{sup 3+}{sub 0.04} has 3D micro-pore network structures better than the block-like Gd{sub 1.96}MoO{sub 6}:Eu{sup 3+}{sub 0.04}. Their quantum efficiency has been investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent upgrades and new scientific infrastructure of MARIA research reactor, Otwock-Swierk, Poland

The MARIA reactor is open-pool type, water and beryllium moderated. It has two independent primary cooling systems: fuel and pool cooling system. Each fuel assembly is cooled down separately in pressurized channels with individual performances characterization. The fuel assemblies consist of five layers of bent plates or six concentric tubes. Currently it is one of the most powerful research reactors in Europe with operation availability at least up to 2030. Its nominal thermal power is 30 MW. It is characterized by high neutron flux density: up to 3x10{sup 14} n cm{sup -2} s{sup -1} in case of thermal neutrons, and up to 2x10{sup 13} n cm{sup -2} s{sup -1} in case of fast neutrons. The reactor is operated for ca. 4000 h per year. The reactor facility is equipped with fully equipped three hot cells with shielding up to 10{sup 15} Bq. Adjacent to the reactor facility, the radio-pharmaceutics plant (POLATOM) and Material Research Laboratory are located. They are equipped with a number of hot cells with instrumentation. The transport system of radioactive materials from reactor facility to Material Research Laboratory is available. During 2014 the MARIA reactor has been operated with three different types of fuel the same time: previous 36% enriched fuel, and two types of new LEU fuels. In the meantime, molybdenum irradiation programme has been developed. Maria is a multifunctional research tool, with a notable application in production of radioisotopes, radio-pharmaceutics manufacturing (ca. 600 TBq/y), {sup 99}Mo for medical scintigraphy (ca. 6000 TBq/y), neutron transmutation doping of silicon single crystals, wide scientific research based on neutron beams utilization. From the beginning MARIA reactor was intended for loop and fuel testing research activities. Currently it is used mostly as material testing and irradiation facility and for that reason it has wide experimental capabilities. There are eight horizontal irradiation channels from among whom six of them are equipped with instrumentation for condensed matter physics research: - H3 - spectrometer and diffractometer with double monochromator; - H4 - small angle scattering spectrometer; - H5 - polarized neutrons spectrometer; - H6, H7 - two 3-axial crystal neutron spectrometers; - H8 - neutron radiography stand. For two horizontal channels are ongoing exploitation programs: - H2 - station with epithermal neutron beam produced in uranium converter is being developed. Intelligent converter will be installed on the periphery of reactor core. The intensity of the beam will be at the level 2x10{sup 9} n cm{sup -2}s{sup -1} what makes the beam unique in the Europe. - H1 - special pneumatic horizontal mail is being developed for irradiation material samples in the vicinity of the core i.e. in the distal part of the H1 channel. The number of neutron irradiation facilities in MARIA reactor is increasing every year. Numerous of thermal neutron irradiation channels including fast hydraulic rabbit system and large size channels for fast neutron irradiation are used routinely. Recently new in-pile facility with ITER-like neutron energy spectrum for 14 MeV neutron irradiation has been constructed. Taking into account its performance and ability of almost incessant operation the facility appears as one of the most powerful 14 MeV neutron sources. The facility shall be used for material research connected with thermonuclear devices (ITER) and 4. generation nuclear reactors. The system of independent fuels channels used in MARIA reactor appear to be very flexible and very convenient to be used as irradiation channels for uranium targets for {sup 99}Mo production. Currently, MARIA reactor supplies ca. 18% world production of {sup 99}Mo. The MARIA reactor research activities are still extended. The current scientific projects are connected e.g. with silicon neutron transmutation doping, in-pile gamma heating measurements, French calculation codes implementation (TRIPOLI4, APOLLO2). The horizontal neutron beams utilization is also developed. The MARIA reactor, due to its primary application connected with loop and fuel testing, is very convenient for testing the nuclear instrumentation, control and measurement systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

{sup 6}LiF:ZnS(Ag) Neutrons Scintillator Detector Configuration for Optimal Readout

A Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is under development at the NIST Center for Neutron Research (NCNR). The CANDOR neutron sensor will rely on scintillator material for detecting the neutrons scattered by the sample under test. It consists of {sup 6}LiF:ZnS(Ag) scintillator material into which wavelength shifting (WLS) fibers have been embedded. Solid state photo-sensors (silicon photomultipliers) coupled to the WLS fibers are used to detect the light produced by the neutron capture event ({sup 6}Li (n,α) {sup 3}H reaction) and ionization of the ZnS(Ag). This detector configuration has the potential to accomplish the CANDOR performance requirements for efficiency of 90% for 5 A (3.35 meV) neutrons with high gamma rejection (10{sup 7}) along with compact design, affordable cost and materials availability. However this novel design includes challenges for precise neutron detection. The recognizing of the neutron signature versus the noise event produce by gamma event cannot be easy overcome by pulse height discrimination obstacle as can be achieved with {sup 3}He gas tube. Furthermore the selection of silicon photomultipliers (SiPM) as the light sensor maintains the obstacle of dark noise that does not exist when a photomultiplier tube is coupled to the scintillator. A proper selection of SiPM should focus on increasing the output signal and reducing the dark noise in order to optimize the detection sensitivity and to provide a clean signal pulse shape discrimination. The main parameters for evaluation are: - Quantum Efficiency (QE) - matching the SiPM peak QE with the peak transmission wavelength emission of the WLS. - Recovery time - a short recovery time is preferred to minimize the pulse width beyond the intrinsic decay time of the scintillator crystal (improves the gamma rejection based output pulse shape (time)). - Diode dimensions -The dark noise is proportional to the diode active area while the signal is provided by the WLS fibers; therefore the diode area should ideally be only minimally larger than fiber bundle area. - Low dark noise - it is desirable to minimize the dark noise during the pulse integration period so as to minimize the background for pulse shape discrimination. - Photon Detection Efficiency - it is desirable to increase the SiPM PDE in order to enhance light collection. This will increase the likelihood of detecting neutron events with lower light production and will present a cleaner raw signal for pulse shape discrimination. We will present the SiPM optimization process and studies of dark noise and gamma and neutron sensitivity as a function of bias voltage and operating temperature that have enabled us to optimize the detector sensitivity and gamma rejection. The gamma rejection performance goal requires to overcome the challenge of discriminating between the light signature accepted by neutron event to the one received by the noise. In addition there is a huge variation between the number of light photons that reaching the WLS fibers for different neutron events caused by the heavy ions energy losses prior to ionizing the ZnS(Ag) and the high light attenuation of the scintillation mixture. This variation in the light signal along with the long decay time of the ZnS(Ag) (tens of microseconds) can cause double counting of the same neutron event in the case of high light output signature or preventing the detection of low sequential light output signature neutron event. We will presents the algorithm developed for {sup 6}LiF:ZnS(Ag) sensor readout and the results achieved by an off-line analysis by Matlab software code that successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-crystal neutron diffraction studies on Ni-based metal-pnictide superconductor BaNi2As2

We report the results of single-crystal neutron diffraction studies of the superconductor BaNi{sub 2}As{sub 2}. The experiments were performed on a tiny crystal of mass 0.8 mg at several temperatures between 20 and 200 K using the Single Crystal Diffractometer, SCD, at the Los Alamos Neutron Science Center. Above 130 K, BaNi{sub 2}As{sub 2} crystallizes in the tetragonal ThCr{sub 2}Si{sub 2} structure. Our neutron diffraction data corroborate a first-order structural transition around 130 K with a relatively large hysteresis of about 10K, in agreement with observations from bulk studies. The anisotropic thermal displacement coefficients are enhanced along c-axis approaching the transition, and a splitting is observed for in-plane type reflections below the transition, which is evidence for a change in crystal structure.

36 MATERIALS SCIENCE↗

Investigation on Growth and Surface Analysis of DAST Single Crystals

We have explored the growth of bulk size N, N-dimethylamino-N'-methylstilbazolium p-toluenesulphonate (DAST) using slope nucleation method. The grown crystal was characterized by single crystal X-ray diffraction (XRD), and CHN analyses. The surface morphology of the crystal was analyzed using Scanning electron microscopy (SEM).

36 MATERIALS SCIENCE↗

Milestones and basic principles of grating-based x-ray and neutron phase-contrast imaging

This is a review of the most important milestones in the last ten years of development in the field of grating-based x-ray and neutron imaging. It provides a description of the basic imaging principles of grating-based phase-contrast and dark-field radiography and present some exemplary multimodal radiography results obtained with x-rays and neutrons. Furthermore, it reviews the theory of grating-based quantitative transmission, phase-contrast, and dark-field scattering computed tomography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument Monitoring, Data Sharing, and Archiving Using Common Instrument Middleware Architecture (CIMA)

The Common Instrument Middleware Architecture (CIMA) aims at Grid-enabling a wide range of scientific instruments and sensors to enable easy access to and sharing and storage of data produced by these instruments and sensors. This paper describes the implementation of CIMA applied to the field of single-crystal X-ray crystallography. To allow the researchers to easily view the current and past data streams from the instruments or sensors in a laboratory, a crystallography portal and associated portlets were developed for this application. The CIMA-based crystallography system provides an opportunity for anyone with Web access to observe and use crystallographic and other data from laboratories that previously had only limited access.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An instrument for combining x-ray multiple diffraction and x-ray topographic imaging for examining crystal microcrystallography and perfection

Diffraction imaging using x-ray topography (XRT) and x-ray multiple diffraction (XRMD) provide valuable tools for examining the growth defects in crystals and the distributions from ideal lattice symmetry (microcrystallography). The topographic x-ray multiple diffraction microprobe (TMDM) combines the complementary aspects of both techniques enabling XRT and XRMD studies within the same instrument providing a useful resource for the structural characterization of materials that are not very stable in vacuum and electron beam environments. The design of the TMDM instrument is described together with data taken on GaAs (001) and potassium dihydrogen phosphate (001)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Construction of x-ray scattering and x-ray absorption fine structure beamline at the Pohang Light Source

A new hard x-ray beamline, 10B KIST-PAL beamline (BL10B), has been designed and constructed at the Pohang Light Source (PLS) in Korea. The beamline, operated by Pohang Accelerator Laboratory-Korean Institute of Science and Technology consortium, is dedicated to x-ray scattering (XRS) and x-ray absorption fine structure (XAFS) experiments. X rays with photon energies from 4.0 to 16.0 keV are delivered to the experimental station passing a collimating mirror, a fixed-exit double-crystal Si(111) monochromator, and a toroidal mirror. Basic experimental equipments for XAFS measurement, a high resolution diffractometry, an image plate detector system, and a hot stage have been prepared for the station. From our initial commissioning and performance testing of the beamline, it is observed that BL10B beamline can perform XRS and XAFS measurements successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffuse Neutron Scattering Calculation of Spinel Structure of LiMn{sub 2}O{sub 4}

Neutron scattering experiment has been performed on powder LiMn{sub 2}O{sub 4} at room temperature. The structure of LiMn{sub 2}O{sub 4} is analyzed from the Bragg line. The crystal of LiMn{sub 2}O{sub 4} has spinel structure. The profile of diffuse scattering is analyzed including the correlation effects among thermal displacement of atoms Li-Li, Li-Mn, Li-O, Mn-Mn, Mn-O and O-O. The interatomic distance dependence of the values of correlation effects is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Submicrometer Single Crystal Diffractometry for Highly Accurate Structure Determination

Submicrometer single crystal diffractometry for highly accurate structure determination was developed using the extremely stable and highly brilliant synchrotron radiation from SPring-8. This was achieved using a microbeam focusing system and the submicrometer precision low-eccentric goniometer system. We demonstrated the structure analyses with 2x2x2 {mu}m{sup 3} cytidine, 600x600x300 nm{sup 3} BaTiO{sub 3}, and 1x1x1 {mu}m{sup 3} silicon. The observed structure factors of the silicon crystal were in agreement with the structure factors determined by the Pendelloesung method and do not require absorption and extinction corrections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructure Study For Optimization Of Dielectric Property Of Electrical Porcelain

Five sample mixtures of kaolin, ball clay, feldspar and Quartz were formulated and porcelain samples fabricated. Crystalline phases and mullite morphology were studied using XRD and SEM respectively. A composition of 30% kaolin, 15% ball clay, 30% feldspar and 25% quartz yielded a body with high dielectric strength of 19 kV/mm compare to an ISO graded product having dielectric strength 14.6 KV/mm after firing at 1225 deg. C.

36 MATERIALS SCIENCE↗

The effect of exit beam phase aberrations on parallel beam coherent x-ray reconstructions

Diffraction artifacts from imperfect x-ray windows near the sample are an important consideration in the design of coherent x-ray diffraction measurements. In this study, we used simulated and experimental diffraction patterns in two and three dimensions to explore the effect of phase imperfections in a beryllium window (such as a void or inclusion) on the convergence behavior of phasing algorithms and on the ultimate reconstruction. A predictive relationship between beam wavelength, sample size, and window position was derived to explain the dependence of reconstruction quality on beryllium defect size. Defects corresponding to this prediction cause the most damage to the sample exit wave and induce signature error oscillations during phasing that can be used as a fingerprint of experimental x-ray window artifacts. The relationship between x-ray window imperfection size and coherent x-ray diffractive imaging reconstruction quality explored in this work can play an important role in designing high-resolution in situ coherent imaging instrumentation and will help interpret the phasing behavior of coherent diffraction measured in these in situ environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality Control On Strained Semiconductor Devices

New semiconductor devices are based very often on strained silicon which promises to squeeze more device performance out of current devices. With strained silicon it is possible to get the same device performance using less power. The technique is using strain as a 'design element' for silicon to improve the device performance and has become a hot topic in semiconductor research in the past years. However in the same time topics like 'System in Package'(SiP) on thin wafers are getting more and more important. The chips of thin wafers in advanced packaging are extremely sensitive to induced stresses due to packaging issues. If we are using now strain as a design element for improving device performance we increase the sensitivity again and therefore also the risk of aging of such SiP's. High Resolution X-ray diffraction (HRXRD) techniques such as Rocking Curves (RC's) and Reciprocal Space Mapping (RSM) are therefore very powerful tools to study the stresses in packaged devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗