The Historical Development of Large‐Scale Paleoclimate Field Reconstructions Over the Common Era

Abstract Climate field reconstructions (CFRs) combine modern observational data with paleoclimatic proxies to estimate climate variables over spatiotemporal grids during time periods when widespread observations of climatic conditions do not exist. The Common Era (CE) has been a period over which many seasonally‐ and annually‐resolved CFRs have been produced on regional to global scales. CFRs over the CE were first produced in the 1970s using dendroclimatic records and linear regression‐based approaches. Since that time, many new CFRs have been produced using a wide range of proxy data sets and reconstruction techniques. We assess the early history of research on CFRs for the CE, which provides context for our review of advances in CFR research over the last two decades. We review efforts to derive gridded hydroclimatic CFRs over continental regions using networks of tree‐ring proxies. We subsequently explore work to produce hemispheric‐ and global‐scale CFRs of surface temperature using multi‐proxy data sets, before specifically reviewing recently‐developed data assimilation techniques and how they have been used to produce simultaneous reconstructions of multiple climatic fields globally. We then review efforts to develop standardized and digitized databases of proxy networks for use in CFR research, before concluding with some thoughts on important next steps for CFR development.

Smerdon, Jason E.↗

Describing Function Analysis of Transformer Magnetizing Inductance for Direct Power Control of Back-to-Back Modular Multilevel Converters with Advanced Grid Support

This paper provides a detailed investigation into the application of describing function-based analysis for assessing transformer magnetizing inductance and its impact on system performance. The focus is on a back-to-back modular multilevel converter architecture, designed to interconnect systems operating at different frequencies. The study explores the implementation of a Direct Power Control strategy, examining its effects on transformer magnetizing inductance saturation and offering effective mitigation techniques. Furthermore, the integration of advanced grid support functionalities is highlighted, demonstrating how these enhancements bolster the converter's ability to improve grid stability and power quality, positioning it as a robust solution for modern power systems. The proposed approach is validated through extensive computer simulations based MAT LAB/Simulink domain, supported by significant case study results, confirming its practical effectiveness.

back-to-back modular multilevel converters (B2B- M↗

Elevation Grid for top Columbia River Basalt (CRBG) in the Portland Basin used in DDU Feasibility Study

The Portland Basin is a prime location to assess the feasibility of DDU-TES because natural geologic conditions provide thermal and hydraulic separation from overlying aquifers that would otherwise sweep away stored heat. Under the Portland Basin, the lower Columbia River Basalt Group (CRBG) aquifers contain brackish water (1,000-10,000 mg/L TDS), indicating low groundwater flow rates and poor connection with the overlying regional aquifer. Further, CRBG lavas tend to have comparatively low thermal conductivity, indicating that the 400-1,000 ft thick CRBG may be an effective thermal barrier to the overlying aquifer. A temporally and spatially limited previous study of a Portland Basin CRBG aquifer demonstrated that the injection of waste heat resulted in an increase in temperature by more than a factor of two, indicating a high potential for storing heat. This data submission includes ASCII grid surfaces for the Portland and Tualatin Basins including a DEM of modern topography, the top of Columbia River Basalt (CRB), the base of CRB, and basement. It also includes three isochore (thickness) maps between these intervals. In addition, there is an ArcGIS attribute table for associated data points, a map of data types used to constrain the top of CRB, and cross-sections, all made using IHS Kingdom Suite, Petrosys PRO, ESRI ArcGIS, and Adobe Illustrator software.

15 GEOTHERMAL ENERGY↗

Simulation of the 23 July 2012 Extreme Space Weather Event: What if This Extremely Rare CME Was Earth Directed?

Extreme space weather events are known to cause adverse impacts on critical modern day technological infrastructure such as high-voltage electric power transmission grids. On 23 July 2012, NASA's Solar Terrestrial Relations Observatory-Ahead (STEREO-A) spacecraft observed in situ an extremely fast coronal mass ejection (CME) that traveled 0.96 astronomical units (approx. 1 AU) in about 19 h. Here we use the SpaceWeather Modeling Framework (SWMF) to perform a simulation of this rare CME.We consider STEREO-A in situ observations to represent the upstream L1 solar wind boundary conditions. The goal of this study is to examine what would have happened if this Rare-type CME was Earth-bound. Global SWMF-generated ground geomagnetic field perturbations are used to compute the simulated induced geoelectric field at specific ground-based active INTERMAGNET magnetometer sites. Simulation results show that while modeled global SYM-H index, a high-resolution equivalent of the Dst index, was comparable to previously observed severe geomagnetic storms such as the Halloween 2003 storm, the 23 July CME would have produced some of the largest geomagnetically induced electric fields, making it very geoeffective. These results have important practical applications for risk management of electrical power grids.

SPACE WEATHER↗

Voices of Experience: Microgrids for Resiliency

Modern attitudes around microgrids have evolved, from the idea that microgrids represent "grid defection" to perceiving them as a tool that utilities can use to solve challenges. One such challenge is improving resiliency. Faced with unpredictable, yet intensifying and dynamic weather and cyber risks, the value of resiliency is only growing for utility customers, regulators, and policymakers. Moreover, policymakers and regulators are increasingly asking utilities to accommodate the expansion and enhancement of such resiliency. The purpose of Voices of Experience: Microgrids for Resiliency is to guide discussions around this topic - everything from defining the many types of microgrids, to siting, ownership, control, and value streams. Utilities who participated in this project were generous with their time, insights, and examples of how they are using microgrids to solve one of their most urgent challenges: resiliency.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clean Grid Vision: A U.S. Perspective - Chapter 5. Global Power Market Trends

The evolution of the electricity sector toward competitive modern markets is occurring over a long period and responding to rapid changes in technologies, business models, and other market factors. No reformed power market anywhere in the world looks the same today as it did a decade ago. Technology has enabled some of the evolution, but perhaps it is more important that people and institutions learn from experience how to make markets better over time. Governments still have an important role—not as the authority controlling prices, but as the authority safeguarding the integrity of the economic processes that create prices in response to supply and demand and ensure reliability and other objectives are met. More VRE resources will change market conditions, but they will not change market fundamentals. Prices provide important signals for new investments and how the grid operates—including new technologies and processes discussed elsewhere in this report. If poor market design or the exercise of market power by a large entity distort these signals, outcomes will cease to be efficient and the public will bear the additional cost. Fundamentally, prices reflect supply, demand, and the cost of technological options.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Opportunities and Challenges for Solar Minigrid Development in Rural India

The goal of this report is to inform investors about the potential of solar minigrid technologies to serve India’s rural market. India, a rapidly emerging economy with the world’s second largest population, is facing a surging energy demand. A large portion of India’s rural population, which represents 60% of the total population, does not have access to reliable electricity or has limited access and relies heavily on fuels such as wood, diesel, and kerosene to fulfill energy needs. Using the most recent available expenditure data, it is estimated that India’s rural consumers currently spend US$\$$4.86 billion (INR 243 billion ) per year on energy. Because of the linkages between reliable electricity supply, gross domestic product growth, and living standards, the Indian government is accelerating the deployment of electricity to India’s rural population. In January 2010, India’s Ministry of New and Renewable Energy (MNRE) under the Jawaharlal Nehru National Solar Mission (JNNSM) announced the goal of deploying 20 gigawatts (GW) of grid-connected solar power and 2 GW of off-grid solar by 2022. Their objective is to invest in India’s vast solar resources by deploying solar energy on a broad scale and extending modern power services to millions. Specifically, the JNNSM in Phase I of the mission has set the goal of implementing 1 GW of grid-connected solar and 200 megawatts (MW) of off-grid solar power (rural village electrification) by March 2013. By providing many incentives for renewable energy projects, including capital subsidies of up to 90%, tax holidays, and low-interest loans, the government is hoping to spur clean energy development in key areas. India’s electricity demand is expected to increase from 900 billion kilowatt-hours (kWh) to 1,400 billion kWh by March 2017. To meet this demand, India’s power sector overall will need an investment of US$\$$300 billion to US$\$$400 billion during the five-year economic plan that started April 2012 and ends March 2017 to meet its generation targets. MNRE’s target of installing 1,100 MW of solar minigrid capacity in the next five years will require public and private sector investments of roughly $\$$US4.4 billion.

14 SOLAR ENERGY↗

A Computational Review of Privacy-Preserving Mechanisms for the Smart Grid

Smart grid technologies have rapidly become one of the largest and most comprehensive sources of data for the modern utility. For the most part, data streams are seen as an essential tool that enable utilities to carry their day-to-day business operations, but they also create the need for efficient and secure data management strategies. In the context of the smart grid, ensuring data privacy is becoming an increasing concern due to a combination of factors that range from shifts in operational paradigms and rapid technology evolution to changes in legislation. Furthermore, researchers have highlighted the risks associated with improperly protected energy records. For example, energy consumption data from homes could be used to infer the behaviors and habits of home occupants through activity recognition or user profiling (Fan, 2017), which may lead to unfair service pricing, targeted advertising, or other personal security violations. Similarly, Electric Vehicles’ (EVs) charging metadata could be used to reveal private information about the owner such as their payment methods, preferred charging stations, and other locational and timing information that could be used to reconstruct the vehicle owner’s behaviors. The privacy of user data, even when used for statistical analysis or machine learning training processes, also needs to be carefully considered, as an individual’s private traits may still be vulnerable if their inclusion/exclusion greatly impacts the result or could be linked to a public dataset through cross-reference. The breach of user privacy also has severe impacts for organizations that store, transmit, or work on the data in the form of diminishing the public’s trust in them while potentially incurring legal consequences (e.g., fines and suspensions under the European Union General Data Protection Regulation, Health Insurance Portability and Accountability Act, etc.). Because of these risks, several privacy-preserving mechanisms are available to help organizations comply with privacy legislations and prevent the unauthorized and malicious use of user data. In light of these concerns, this report focuses on performing a computational review of privacy-preserving mechanisms that have received a significant amount of interest in literature. It specifically focuses on 1) homomorphic encryption, 2) zero-knowledge proofs, 3) differential privacy, and 4) federated learning. It is worth noting that although many of the methods presented in this document rely on cryptographic primitives, their intent is not to provide perfect secrecy, but rather to enable users to maintain privacy, and thus they shall not be compared or equated to other constructs that are aimed to address cybersecurity constructs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resolving Mesoscale Convective Systems: Grid Spacing Sensitivity in the Tropics and Midlatitudes

Abstract Mesoscale convective systems (MCSs) are a critical global water cycle component and drive extreme precipitation events in tropical and midlatitude regions. However, simulating deep convection remains challenging for modern numerical weather and climate models due to the complex interactions of processes from microscales to synoptic scales. Recent models with kilometer‐scale horizontal grid spacings offer notable improvements in simulating deep convection compared to coarser‐resolution models. Still, deficiencies in representing key physical processes, such as entrainment, lead to systematic biases. Additionally, evaluating model outputs using process‐oriented observational data remain difficult. This study presents an ensemble of MCS simulations with spanning the deep convective gray zone ( from 12 km to 125 m) in the Southern Great Plains of the U.S. and the Amazon Basin. Comparing these simulations with Atmospheric Radiation Measurement (ARM) wind profiler observations, we find greater sensitivity in the Amazon Basin compared to the Great Plains. Convective drafts converge structurally at sub‐kilometer scales, but some deficiencies remain. In both regions, simulated up and downdrafts are too deep and extreme downdrafts are not strong enough. Furthermore, Amazonian updrafts are too strong. Overall, we observe higher sensitivity in the tropics, including an artificial buildup in vertical kinetic energy at scales of , suggesting a need for 250 m in this region. Nevertheless, bulk convergence—agreement of storm‐average statistics—is achievable with kilometer‐scale simulations within a 10% error margin with 1 km providing a good balance between accuracy and computational cost.

54 ENVIRONMENTAL SCIENCES↗

Adoption of a token-based authentication model for the CMS Submission Infrastructure

The CMS Submission Infrastructure (SI) is the main computing resource provisioning system for CMS workloads. A number of HTCondor pools are employed to manage this infrastructure, which aggregates geographically distributed resources from the WLCG and other providers. Historically, the model of authentication among the diverse components of this infrastructure has relied on the Grid Security Infrastructure (GSI), based on identities and X509 certificates. In contrast, commonly used modern authentication standards are based on capabilities and tokens. The WLCG has identified this trend and aims at a transparent replacement of GSI for all its workload management, data transfer and storage access operations, to be completed during the current LHC Run 3. As part of this effort, and within the context of CMS computing, the Submission Infrastructure group is in the process of phasing out the GSI part of its authentication layers, in favor of IDTokens and Scitokens. The use of tokens is already well integrated into the HTCondor Software Suite, which has allowed us to fully migrate the authentication between internal components of SI. Additionally, recent versions of the HTCondor-CE support tokens as well, enabling CMS resource requests to Grid sites employing this CE technology to be granted by means of token exchange. After a rollout campaign to sites, successfully completed by the third quarter of 2022, the totality of HTCondor CEs in use by CMS are already receiving Scitoken-based pilot jobs. On the ARC CE side, a parallel campaign was launched to foster the adoption of the REST interface at CMS sites (required to enable token-based job submission via HTCondor-G), which is nearing completion as well. In this contribution, the newly adopted authentication model will be described. We will then report on the migration status and final steps towards complete GSI phase out in the CMS SI.

Pérez-Calero Yzquierdo, Antonio↗

GRAPEVINE: Grids about anything by Poisson's equation in a visually interactive networking environment

A proven 3-D multiple-block elliptic grid generator, designed to run in 'batch mode' on a supercomputer, is improved by the creation of a modern graphical user interface (GUI) running on a workstation. The two parts are connected in real time by a network. The resultant system offers a significant speedup in the process of preparing and formatting input data and the ability to watch the grid solution converge by replotting the grid at each iteration step. The result is a reduction in user time and CPU time required to generate the grid and an enhanced understanding of the elliptic solution process. This software system, called GRAPEVINE, is described, and certain observations are made concerning the creation of such software.

Sorenson, Reese L.↗

Reimagining Energy Efficiency Resource Standards

Energy Efficiency Resource Standards (EERS) are a long-standing policy used to advance state goals and priorities, such as reliability, affordability and decarbonization. They ensure cost-effective energy efficiency is used to lower energy consumption, reduce peak demand, and enable grid flexibility. Adapting EERS through strategic design, and integrating EERS into broader energy plans and policies, can help states optimize their approach to meet modern and evolving power system needs and achieve sustainable energy outcomes. This report examines how states consider energy efficiency in the context of four policy priorities: providing grid benefits, addressing load growth, reducing emissions, and promoting affordability. It provides examples of states that are pursuing these priorities, reviews the role of energy efficiency in them and identifies opportunities to further promote energy efficiency alongside the priorities. Decisionmakers and stakeholders can draw directly from these examples and findings to design an EERS that maximizes co-benefits, captures synergies, and promotes consideration of the all the possible solutions to advance their goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Review of Codes and Standards for Energy Storage Systems

This article identifies several examples of industry efforts and successes in removing gaps in energy storage (ES) Codes & Standards (C&S) by updating or creating and publishing new standards. A particular challenge discussed in this article is that while modern battery technologies including lithium ion (Li-ion) increase technical and economic viability of grid energy storage, newer battery technologies also present new or unknown risks to managing the safety of energy storage systems (ESS). There has been progress in filling gaps in published ES C&S that recognize and address the expanding range of technologies and their unique characteristics. However, there remain significant need and opportunity for researchers to contribute to the underlying knowledge base that informs development of technical references and standards, and ultimately the application of published standards for the effective and safe design and use of modern ESS.

Energy Storage, Codes and Standards↗

Rapid Event Detection via Synchro-Waveform Based Temporal Attention Network in Distributed Grid

Compared with the information collected from phasor measurement units, synchro-waveforms contain high-fidelity disturbances of the grid, which can be a granular and authentic representation of measurements in the modern power system. However, the dynamic changing morphology makes it challenging to effectively capture various disturbance information from the synchro-waveforms. To tackle this issue, this paper proposes a Synchro-waveform based Temporal Attention (STA) network to achieve rapid event detection. First, a multi-scenario distributed model with renewable integration is established to generate synchro-waveforms under various uncertainties. Then, three typical temporal features are extracted directly from the synchro-waveform measurements. Additionally, the lightweight STA network is deployed to identify the most common event types in renewable energy systems via the self-attention based vision transformer module. The results from simulated experiments demonstrate that the proposed approach can achieve rapid and real-time detection within 0.81 ms and over 96.27 % accuracy.

Dong, Yuqing [University of Tennessee (UT)]↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Utility-Scale Operational Consequences for Solar Grid Services

This report delves into the critical aspects of grid services provided by solar inverter-based resources (IBRs), with an emphasis on the evolving landscape of microgrids, virtual power plants (VPPs), aggregators, and distributed energy resource management systems (DERMS). As the energy sector undergoes a transformative shift towards more decentralized and resilient grid architectures, understanding the multifaceted risks associated with these technologies becomes paramount. The report categorizes these risks into organizational, technical, and procedural domains, providing a thorough risk assessment framework that stakeholders can utilize to anticipate and mitigate potential issues. In addressing the increasing complexity of grid interconnections, the report highlights the importance of Cyber-Informed Engineering (CIE). By embedding engineering controls and cybersecurity measures into the early stages of system design, this approach aims to fortify grid infrastructure against emerging cyber threats. The analysis includes an exploration of best practices and strategies for integrating CIE principles to enhance grid security and resilience. To provide practical insights, the report conducts a detailed consequence analysis of various grid services and cyber mitigations that can be applied through the interconnection process. This analysis evaluates the potential impacts of different failure modes and vulnerabilities, offering a clear understanding of the consequences that could arise from disruptions within the energy grid. The findings are further enriched by a series of case studies that illustrate real-world scenarios and lessons learned from past incidents. Through this comprehensive examination of grid services and their criticality, the report aims to prepare industry professionals with the knowledge and tools necessary to navigate the complexities of modern energy systems. By providing a comprehensive approach that includes risk assessment, cybersecurity, and consequence analysis, solar stakeholders can more effectively guarantee the reliability, efficiency, and security of the energy grid.

14 SOLAR ENERGY↗

Cyber Threat and Vulnerability Analysis of the U.S. Electric Sector

With utilities in the U.S. and around the world increasingly moving toward smart grid technology and other upgrades with inherent cyber vulnerabilities, correlative threats from malicious cyber attacks on the North American electric grid continue to grow in frequency and sophistication. The potential for malicious actors to access and adversely affect physical electricity assets of U.S. electricity generation, transmission, or distribution systems via cyber means is a primary concern for utilities contributing to the bulk electric system. This paper seeks to illustrate the current cyber-physical landscape of the U.S. electric sector in the context of its vulnerabilities to cyber attacks, the likelihood of cyber attacks, and the impacts cyber events and threat actors can achieve on the power grid. In addition, this paper highlights utility perspectives, perceived challenges, and requests for assistance in addressing cyber threats to the electric sector. There have been no reported targeted cyber attacks carried out against utilities in the U.S. that have resulted in permanent or long term damage to power system operations thus far, yet electric utilities throughout the U.S. have seen a steady rise in cyber and physical security related events that continue to raise concern. Asset owners and operators understand that the effects of a coordinated cyber and physical attack on a utility’s operations would threaten electric system reliability–and potentially result in large scale power outages. Utilities are routinely faced with new challenges for dealing with these cyber threats to the grid and consequently maintain a set of best practices to keep systems secure and up to date. Among the greatest challenges is a lack of knowledge or strategy to mitigate new risks that emerge as a result of an exponential rise in complexity of modern control systems. This paper compiles an open-source analysis of cyber threats and risks to the electric grid, utility best practices for prevention and response to cyber threats, and utility suggestions about how the federal government can aid utilities in combating and mitigating risks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent development of the Multi-Grid detector for large area neutron scattering instruments

Most of the Neutron Scattering facilities are committed in a continuous program of modernization of their instruments, requiring large area and high performance thermal neutron detectors. Beside scintillators detectors, {sup 3}He detectors, like linear PSDs (Position Sensitive Detectors) and MWPCs (Multi-Wires Proportional Chambers), are the most current techniques nowadays. Time Of Flight instruments are using {sup 3}He PSDs mounted side by side to cover tens of m{sup 2}. As a result of the so-called '{sup 3}He shortage crisis{sup ,} the volume of 3He which is needed to build one of these instruments is not accessible anymore. The development of alternative techniques requiring no 3He, has been given high priority to secure the future of neutron scattering instrumentation. This is particularly important in the context where the future ESS (European Spallation Source) will start its operation in 2019-2020. Improved scintillators represent one of the alternative techniques. Another one is the Multi-Grid introduced at the ILL in 2009. A Multi-Grid detector is composed of several independent modules of typically 0.8 m x 3 m sensitive area, mounted side by side in air or in a vacuum TOF chamber. One module is composed of segmented boron-lined proportional counters mounted in a gas vessel; the counters, of square section, are assembled with Aluminium grids electrically insulated and stacked together. This design provides two advantages: First, magnetron sputtering techniques can be used to coat B{sub 4}C films on planar substrates, and second, the neutron position along the anode wires can be measured by reading out individually the grid signals with fast shaping amplifiers followed by comparators. Unlike charge division localisation in linear PSDs, the individual readout of the grids allows operating the Multi-Grid at a low amplification gain, hence this detector is tolerant to mechanical defects and its production accessible to laboratories equipped with standard equipment. Prototypes of different configurations and sizes have been developed and tested. A demonstrator, with a sensitive area of 0.8 m x 3 m, has been studied during the CRISP European project; it contains 1024 grids, and a surface of isotopically enriched B{sub 4}C film close to 80 m{sup 2}. Its size represented a challenge in terms of fabrication and mounting of the detection elements. Another challenge was to make the gas chamber mechanically compatible with operation in a vacuum TOF chamber. Optimal working condition of this detector was achieved by flushing Ar-CO{sub 2} at a pressure of 50 mbar, and by applying 400 Volts on the anodes. This unusual gas pressure allows to greatly simplifying the mechanics of the gas vessel in vacuum. The detection efficiency has been measured with high precision for different film thicknesses. 52% has been measured at 2.5 Angstrom, in good agreement with the MC simulation. A high position resolution has been achieved by centre of gravity measurement of the TOT (Time-Over-Threshold) signals between neighbouring grids. These results, as well as other detection parameters, including gamma sensitivity and spatial uniformity, will be presented. (author)