Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Dirac Fermion Cloning, Moiré Flat Bands, and Magic Lattice Constants in Epitaxial Monolayer Graphene

Tuning interactions between Dirac states in graphene has attracted enormous interest because it can modify the electronic spectrum of the 2D material, enhance electron correlations, and give rise to novel condensed-matter phases such as superconductors, Mott insulators, Wigner crystals, and quantum anomalous Hall insulators. Previous works predominantly focus on the flat band dispersion of coupled Dirac states from different twisted graphene layers. Here in this work, a new route to realizing flat band physics in monolayer graphene under a periodic modulation from substrates is proposed. Graphene/SiC heterostructure is taken as a prototypical example and it is demonstrated experimentally that the substrate modulation leads to Dirac fermion cloning and, consequently, the proximity of the two Dirac cones of monolayer graphene in momentum space. Theoretical modeling captures the cloning mechanism of the Dirac states and indicates that moiré flat bands can emerge at certain magic lattice constants of the substrate, specifically when the period of modulation becomes nearly commensurate with the ($\sqrt{3}$ x $\sqrt{3}$) R30° supercell of graphene. Our results show that epitaxial single monolayer graphene on suitable substrates is a promising platform for exploring exotic many-body quantum phases arising from interactions between Dirac electrons.

36 MATERIALS SCIENCE↗

Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr 3 Single‐Crystal Semiconductor Detector

Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .

Pan, Lei↗

Perovskite CsPbBr 3 Single-Crystal Detector Operating at 10 10 Photons s -1 mm -2 for Ultra-High Flux X-ray Detection

Semiconductors for detecting hard radiation are confronted with considerable problems when operating at high photon fluxes. A perovskite CsPbBr 3 single-crystal detector capable of operating at X-ray fluxes of up to 10 10 photons s -1 mm -2 with beam area ≤ 0.25 mm 2 at 58.61 keV for current-mode X-ray detection is reported. The spectrometer-grade melt-grown CsPbBr 3 detectors show a gamma-ray energy resolution of ~7.5% at 122 keV for 57 Co and dark current as low as 4.3 nA (0.5 nA mm -2 ) at a reverse bias voltage of 200 V (118 V mm -1 ). The detector is tested at X-ray energies of 8.2, 10, and 58.61 keV at a synchrotron light source under a reverse bias voltage of up to 1000 V (588 V mm -1 ). Under a sufficiently high bias voltage and within several hundreds of seconds X-ray exposure, good photocurrent linearity (goodness of fit R 2 > 0.99) and reproducibility are obtained up to a flux of ≈10 10 photons s -1 mm -2 at beam area 0.25 mm 2 with Lower Limit of Detection of ≈10 5 photons s -1 mm -2 and Charge Collection Efficiency of ≈100% for 58.61 keV X-rays. Therefore, wide application of CsPbBr 3 detectors in high-flux X-ray detection is anticipated.

36 MATERIALS SCIENCE↗

First results of the CAST-RADES haloscope search for axions at 34.67 μ eV

We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67 μeV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g aγ ≳ 4 × 10 -13 GeV -1 over a mass range of 34.6738 μeV < m a < 34.6771 μeV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 μeV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for solar axions produced through the axion-electron coupling gae using a new GridPix detector at CAST

We present a search for solar axions produced through the axion-electron coupling (g ae ) using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride windows and multiple veto systems, collected approximately 160 hours of solar tracking data between 2017–2018. Using machine learning techniques and the veto systems, we achieved a background rate of 1.06 × 10 −5 keV −1 cm −2 s −1 at a signal efficiency of about 80% in the 0.2 to 8 keV range. Analysis of the data yielded no significant excess above background, allowing us to set a new upper limit on the product of the axion-electron and axion-photon couplings of g ae · g aγ < 7.35 × 10 −23 GeV −1 at 95% confidence level for axion masses below 10 meV. This result improves upon the previous best helioscope limit and demonstrates the potential of GridPix technology for rare event searches. Additionally, we derived a limit on the axion-photon coupling of g aγ < 9.0 × 10 −11 GeV −1 at 95% CL, which, while not surpassing CAST’s best limit, provides complementary constraints on axion models.

Beyond Standard Model↗

Synthesis of novel benzimidazole–oxadiazole derivatives as potent anticancer activity

DNA topoisomerase I regulates DNA topological structure in many cellular metabolic processes and is a validated target for the development of antitumor agents. In this work, a series of novel 2-[(5-(4-(5(6)-substituted-1H-benzimidazol-2-yl)phenyl)-1,3,4-oxadiazol-2-yl)thio]-1-(4-substitutedphenyl)ethan-1-ones (4a–4s) derivatives have been synthesized and evaluated for DNA Topo I inhibition and cytotoxicity. The structures of the compounds (4a–4s) were confirmed by IR, {sup 1}H-NMR, {sup 13}C-NMR, 2D NMR, and mass spectroscopy. Anticancer activity of these compounds was assessed against two different human cancer cell lines A549 (human lung adenocarcinoma) and HepG2 (human liver cancer cell line), as well as normal mouse embryonic fibroblast cells (NIH3T3). IC{sub 50} values of compounds 4a, 4c, and 4f were highest than those exhibited for the reference drug cisplatin. Then, the inhibitory effect of 4a, 4c, and 4f compounds on topoisomerase I enzyme with the relaxation assay was investigated on supercoiled DNA using agarose gel electrophoresis. The Annexin V-FITC assay demonstrated that these compounds induce cell death by apoptosis.

60 APPLIED LIFE SCIENCES↗

Development of Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Scattering and Energy Dispersive Diffraction Imaging

In this paper we present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electroplating, and proofof-principle fabrication of long strips of SiNx membranes. We demonstrate minimal unwanted effect of strip geometry on X-ray pulse response and showlinear relationship of 1/pulse height and pulse decay times with absorber length. For the absorber lengths studied, our preliminary measurements show energy resolutions of 40-180eV near 17 keV. Furthermore, we show that the heat flow to the cold bath is nearly independent of the absorber area and depends on the SiNx membrane geometry.

47 OTHER INSTRUMENTATION↗

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in X-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard X-ray TESs to measure the absolute energies of muonic-argon (R-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. Here, we achieved similar to 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Devices for Thermal Conductivity Measurements of Electroplated Bi for X-ray TES Absorbers

Electroplated bismuth (Bi) is commonly used in transition-edge sensors (TESs) for X-rays because of its high stopping power and low heat capacity (Collan in Phys Rev B 1:2888, 1970, Yan in Appl Phys Lett 111:192602, 2017). Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow us to measure resistance as a function of temperature of electroplated Bi independently of Au. The results show that the thermal conductivity of the Bi at 3 K is high enough to ensure the correct thermalization of X-ray photons when used as an absorber for TESs.

Bismuth↗

Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a 24-pixel hard X-ray spectrometer array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but larger in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to defects in the bias wiring or microwave multiplexing circuit. We use a method based on group-triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/Delta E similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$E/\Delta {}E \sim$$\end{document} 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can now consider mitigations.

Triamkitsawat, Panthita↗

The structural modification and magnetism of many-layer epitaxial graphene implanted with low-energy light ions

Modifying the properties of graphene has gained wide interest for a plethora of potential applications, including spintronics. One approach has demonstrated that proton irradiation can induce ferromagnetism in graphene as well as in graphite. However, little is known about how the protons interact with graphene, the mechanism that creates the ferromagnetism, or whether the protons remain in the graphene. Here we report an investigation, broadly relevant to graphitic carbon, using low-energy (360–2000 eV) ions of hydrogen, deuterium, and helium implanted into multilayer epitaxial graphene. Complementary x-ray and neutron reflectivity demonstrate that essentially all of the implanted hydrogen remains chemisorbed in graphene. In situ x-ray diffraction reveals significantly different rates of interlayer expansion of the multilayer graphene. Analysis of these data demonstrates that the interlayer expansion arises entirely from the interstitials created by the ions and not from hydrogen that remains in the graphene. The results also establish a quantitative measure of the layer expansion due to carbon interstitials. Magnetometry and x-ray diffraction studies show that the magnetic moment relates to the amount of interstitial carbon rather than the amount of hydrogen, demonstrating that the induced room-temperature ferromagnetism arises directly from the disrupted bonding of the carbon lattice.

36 MATERIALS SCIENCE↗

Disorder and hydrogenation in graphene nanopowder revealed by complementary X-ray and neutron scattering

Functionalization of graphene's two-dimensional sheets can be used to modify the physical properties of graphene, such as changing its conductivity or inducing ferromagnetism, which is of broad interest for a myriad of applications. However, functionalized graphene can possess significant structural disorder that is often overlooked and is difficult to characterize quantitatively. Here we investigate hydrogenated graphene nanopowder (H-Gr) produced by Birch reduction of graphene oxide. By combining complementary x-ray and neutron diffraction, we show how to quantitatively characterize the H-Gr nanostructure, including the hydrogen content. Further, we show that the majority of the H-Gr consists of highly disordered molecular-scale carbon while a small portion of the sample contains few-layered graphene having an expanded interlayer spacing. Modeling the coherent diffuse scattering for both x-ray and neutron diffraction, and comparing it with the incoherent neutron scattering, the hydrogen to carbon ratio was measured and it was determined that most of the hydrogen resides within the disordered carbon rather than in the graphene. Evidence is presented for hydrogen clustering as well as for hydrogen bonded perpendicular to the plane of molecular-carbon bonds. Our quantitative approach to characterizing carbon nanopowders has broad relevance to understanding disorder and bonding of hydrogen in graphitic carbons and other nanomaterials.

36 MATERIALS SCIENCE↗

Proton Radiotherapy to Preserve Fertility and Endocrine Function: A Translational Investigation

Photon radiation therapy (x-ray radiation therapy [XRT] and gamma-ray radiation therapy [GRT]) of tumors close to ovaries causes reproductive and endocrine sequelae due to ovarian primordial follicle depletion. Given its finite range, proton radiation therapy (PRT) can preserve ovarian function when ovaries are positioned distal to the spread-out Bragg peak (SOBP) in tumors of the abdominopelvic region. This study compared anti-Müllerian hormone (AMH) levels (a biomarker of ovarian function) and primordial follicle survival after in vivo mouse pelvic GRT versus PRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dietary Methionine Supplementation Exacerbates Gastrointestinal Toxicity in a Mouse Model of Abdominal Irradiation

Identification of appropriate dietary strategies for prevention of weight and muscle loss in cancer patients is crucial for successful treatment and prolonged patient survival. High-protein oral nutritional supplements decrease mortality and improve indices of nutritional status in cancer patients; however, high-protein diets are often rich in methionine, and experimental evidence indicates that a methionine-supplemented diet (MSD) exacerbates gastrointestinal toxicity after total body irradiation. Here, we sought to investigate whether MSD can exacerbate gastrointestinal toxicity after local abdominal irradiation, an exposure regimen more relevant to clinical settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Interleukin-7 on Radiation-Induced Lymphopenia and Its Antitumor Effects in a Mouse Model

Local ionizing radiation (IR) can lead to systemic lymphocyte depletion, which is associated with poor survival outcomes in patients with cancer. Interleukin-7 (IL-7) plays an important role in lymphocyte homeostasis; however, its role in alleviating radiation-induced lymphopenia remains unclear. Hence, we established a radiation-induced lymphopenia animal model and evaluated the effect of exogenous IL-7 administration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Mouse Model for Microbeam Radiation Therapy of the Lung

Radiation therapy is an important treatment component for patients with lung cancer. However, the survival time gained with clinical radiation therapy techniques is relatively short. Data from preclinical experiments suggest that synchrotron microbeam radiation therapy could be much better suited to control malignant brain tumors than current clinical concepts of radiation therapy. Even at peak doses of several hundred gray, the extent of functional deficits is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗