Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

System and Component Transport Considerations of Micro-Pin Based Solar Receivers With High Temperature Gaseous Working Fluids

This paper explores the interactions between micro-pin concentrated receiver designs with overall solar thermal energy system performance, with different operating conditions, working fluid, and required materials of construction. A 320 MW thermal plant coupled to a 160 MW electric sCO2 Brayton cycle is considered as the baseline. The circulating fluid enters the receiver at 550°C, and leaves at 720°C. The thermal storage/power block are located 150 m from the receiver at the base of the receiver tower. A resistance network based thermal and hydraulic model is used to predict heat transfer and pressure drop performance of the micro-pin receiver. This output of this model is coupled to a system level model of the pressure loss and compressor power required in the remainder of the high temperature gas loop. Overall performance is investigated for supercritical carbon dioxide and helium as working fluids, at pressures from 7.5 to 25 MPa, and at delivery temperatures of 720°C. The results show that by modifying pin depth and flow lengths, there are design spaces for micro-pin devices that can provide high thermal performance without significantly reducing the overall solar thermal system output at lower operating pressures. Use of lower pressure fluids enables lower cost materials of construction in the piping and distribution system, reducing the cost of electricity.

14 SOLAR ENERGY↗

Spectral optimization for micro-CT

Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.

60 APPLIED LIFE SCIENCES↗

Implementation and commissioning of an integrated micro-CT/RT system with computerized independent jaw collimation

Purpose: To design, construct, and commission a set of computer-controlled motorized jaws for a micro-CT/RT system to perform conformal image-guided small animal radiotherapy.Methods: The authors designed and evaluated a system of custom-built motorized orthogonal jaws, which allows the delivery of off-axis rectangular fields on a GE eXplore CT 120 preclinical imaging system. The jaws in the x direction are independently driven, while the y-direction jaws are symmetric. All motors have backup encoders, verifying jaw positions. Mechanical performance of the jaws was characterized. Square beam profiles ranging from 2 × 2 to 60 × 60 mm{sup 2} were measured using EBT2 film in the center of a 70 × 70 × 22 mm{sup 3} solid water block. Similarly, absolute depth dose was measured in a solid water and EBT2 film stack 50 × 50 × 50 mm{sup 3}. A calibrated Farmer ion chamber in a 70 × 70 × 20 mm{sup 3} solid water block was used to measure the output of three field sizes: 50 × 50, 40 × 40, and 30 × 30 mm{sup 2}. Elliptical target plans were delivered to films to assess overall system performance. Respiratory-gated treatment was implemented on the system and initially proved using a simple sinusoidal motion phantom. All films were scanned on a flatbed scanner (Epson 1000XL) and converted to dose using a fitted calibration curve. A Monte Carlo beam model of the micro-CT with the jaws has been created using BEAMnrc for comparison with the measurements. An example image-guided partial lung irradiation in a rat is demonstrated.Results: The averaged random error of positioning each jaw is less than 0.1 mm. Relative output factors measured with the ion chamber agree with Monte Carlo simulations within 2%. Beam profiles and absolute depth dose curves measured from the films agree with simulations within measurement uncertainty. Respiratory-gated treatments applied to a phantom moving with a peak-to-peak amplitude of 5 mm showed improved beam penumbra (80%–20%) from 3.9 to 0.8 mm.Conclusions: A set of computer-controlled motorized jaws for a micro-CT/RT system were constructed with position reliably better than a tenth of a millimeter. The hardware system is ready for image-guided conformal radiotherapy for small animals with capability of respiratory-gated delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-CAMPUS-I-05: Investigation of An EMCCD Detector with Variable Gain in a Micro-CT System

Purpose: To investigate the performance of a newly built Electron Multiplying Charged Coupled Device (EMCCD) based Micro-CT system, with variable detector gain, using a phantom containing contrast agent of different concentrations. Methods: We built a micro- CT system with an EMCCD having 8 microns pixels and on-chip variable gain. We tested the system using a phantom containing five tubes filled with different iodine contrast solutions (30% to 70%). First, we scanned the phantom using various x-ray exposures values at 40 kVp and constant detector gain. Next, for the same tube currents, the detector gain was increased to maintain the air value of the projection image constant. A standard FDK algorithm was used to reconstruct the data. Performance was analyzed by comparing the signal-to-noise ratio (SNR) measurements for increased gain with those for the low constant gain at each exposure. Results: The high detector gain reconstructed data SNR was always greater than the low gain data SNR for all x-ray settings and for all iodine features. The largest increases were observed for low contrast features, 30% iodine concentration, where the SNR improvement approached 2. Conclusion: One of the first implementations of an EMCCD based micro- CT system was presented and used to image a phantom with various iodine solution concentrations. The analysis of the reconstructed volumes showed a significant improvement of the SNR especially for low contrast features. The unique on-chip gain feature is a substantial benefit allowing the use of the system at very low x-ray exposures per frame.Partial support: NIH grant R01EB002873 and Toshiba Medical Systems Corp. Partial support: NIH grant R01EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Gold nanoparticles as high-resolution X-ray imaging contrast agents for the analysis of tumor-related micro-vasculature

Angiogenesis is widely investigated in conjunction with cancer development, in particular because of the possibility of early stage detection and of new therapeutic strategies. However, such studies are negatively affected by the limitations of imaging techniques in the detection of microscopic blood vessels (diameter 3-5 {micro}m) grown under angiogenic stress. We report that synchrotron-based X-ray imaging techniques with very high spatial resolution can overcome this obstacle, provided that suitable contrast agents are used. We tested different contrast agents based on gold nanoparticles (AuNPs) for the detection of cancer-related angiogenesis by synchrotron microradiology, microtomography and high resolution X-ray microscopy. Among them only bare-AuNPs in conjunction with heparin injection provided sufficient contrast to allow in vivo detection of small capillary species (the smallest measured lumen diameters were 3-5 {micro}m). The detected vessel density was 3-7 times higher than with other nanoparticles. We also found that bare-AuNPs with heparin allows detecting symptoms of local extravascular nanoparticle diffusion in tumor areas where capillary leakage appeared. Although high-Z AuNPs are natural candidates as radiology contrast agents, their success is not guaranteed, in particular when targeting very small blood vessels in tumor-related angiography. We found that AuNPs injected with heparin produced the contrast level needed to reveal--for the first time by X-ray imaging--tumor microvessels with 3-5 {micro}m diameter as well as extravascular diffusion due to basal membrane defenestration. These results open the interesting possibility of functional imaging of the tumor microvasculature, of its development and organization, as well as of the effects of anti-angiogenic drugs.

36 MATERIALS SCIENCE↗

Interference effects in laser-induced plasma emission from surface-bound metal micro-particles

Here, the light-matter interaction of an optical beam and metal micro-particulates at the vicinity of an optical substrate surface is critical to the many fields of applied optics. Examples of impacted fields are laser-induced damage in high power laser systems, sub-wavelength laser machining of transmissive materials, and laser-target interaction in directed energy applications. We present a full-wave-based model that predicts the laser-induced plasma pressure exerted on a substrate surface as a result of light absorption in surface-bound micron-scale metal particles. The model predictions agree with experimental observation of laser-induced shallow pits, formed by plasma emission and etching from surface-bound metal micro-particulates. It provides an explanation for the prototypical side lobes observed along the pit profile, as well as for the dependence of the pit shape on the incident laser and particle parameters. Furthermore, the model highlights the significance of the interference of the incident light in the open cavity geometry formed between the micro-particle and the substrate in the resulting pit shape.

42 ENGINEERING↗

Ablating nanoscale pores in crystalline quartz using laser-induced micro-plasmas in tri-layer structures

We demonstrate a novel approach for achieving rapid, consistent, and controllable micro-pore fabrication in single-crystalline quartz. These micro-pores are essential for applications in biology, i.e., studying ion channels in general and mechano-sensitive channels (MSC) in particular. The fabrication process consists of direct material ablation using pulsed UV light from a 193 nm excimer laser. These pulses ablate single-crystalline quartz chips by burning a laser-induced plasma in a tri-layer structure. Controllable plasma confinement and thus pore size is achieved by sandwiching a thin layer of a selected organic solution between the quartz chip and different substrates. This solution causes the confined micro-plasma to generate special ablation conditions, to create uniformly sized and shaped nanopores.

36 MATERIALS SCIENCE↗

Micro-Bubble Experiments at the Van de Graaff Accelerator

In order to test and verify the experimental designs at the linear accelerator (LINAC), several micro-scale bubble ("micro-bubble") experiments were conducted with the 3-MeV Van de Graaff (VDG) electron accelerator. The experimental setups included a square quartz tube, sodium bisulfate solution with different concentrations, cooling coils, gas chromatography (GC) system, raster magnets, and two high-resolution cameras that were controlled by a LabVIEW program. Different beam currents were applied in the VDG irradiation. Bubble generation (radiolysis), thermal expansion, thermal convection, and radiation damage were observed in the experiments. Photographs, videos, and gas formation (O 2 + H 2 ) data were collected. The micro-bubble experiments at VDG indicate that the design of the full-scale bubble experiments at the LINAC is reasonable.

43 PARTICLE ACCELERATORS↗

Performance Monitoring of African Micro-Grids: Good Practices and Operational Data

This report investigates the current understanding and use of performance monitoring in the micro-grid sector by developers. It highlights the importance of performance monitoring by providing key performance monitoring indicators and suggesting performance monitoring activities that improve projects and programs. This report also presents the analysis of the performance data of 36 micro-grids currently operating in Africa, in one of the largest such assessments conducted to date within the sector and concludes by recommending potential next steps towards integrating performance monitoring into the micro-grid sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load Following Analysis of the Holos-Quad 10MWe Micro-Reactor with Plant Dynamics Code

This report presents the load following analysis of the “Holos-Quad” 10MWe micro-reactor design developed by HolosGen LLC. This analysis is focused on the Holos-Quad micro-reactor ability to match the changing grid demand at 10%/min rate. The control mechanisms for the plant are identified, simulated, and compared. Based on the comparison results, control strategy for load following of the Holos-Quad micro-reactor is developed. The control strategy and load following capabilities are demonstrated in a full-range down-and-up reactor power transient from 100% to 0% and back to 100% load at 10%/min rate. All calculations are carried out with Argonne’s Plant Dynamics Code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Precision Low-Cost Micro Birdbath Resonating Gyroscope (CRADA Final Report)

As part of the Cyclotron Road program, Enertia Microsystems Inc. (EMI) investigated a high-performance micro mechanical resonator called the micro birdbath resonator and a high-precision micro electromechanical systems (MEMS) gyroscope called the birdbath resonator gyroscope (BRG). The BRG is a novel fused-silica MEMS gyroscope. The BRG can obtain significantly greater accuracy, comparable size, and comparable cost with MEMS gyroscopes made of silicon that are currently on the market.

47 OTHER INSTRUMENTATION↗

Accelerating the identification of novel secondary metabolites in bioenergy plant root exudates using MicroED

Small molecule metabolites drive inter- and intraspecies communication and dependencies in diverse biological systems, yet a large proportion of these important chemical compounds remain uncharacterized in plants and microbes. Approximately 90% of the metabolites in root exudate profiles are unknown compounds, despite the importance of root exudate composition in plant-microbe interactions. We need advanced analytical capabilities that will support rapid discovery and structural elucidation of metabolites from biological samples that may be limited in quantity and high in complexity. To fill this gap, this project aimed to develop an integrated workflow involving metabolite extraction, separation, and crystallization from plant root exudates followed by characterization using nuclear magnetic resonance (NMR) spectroscopy, mass spectrometry, and microcrystal electron diffraction (MicroED). Using crude root exudates from sorghum, this project successfully developed higher throughput exudate fractionation strategies to obtain pure compounds for crystallization and identified crystals in multiple fractions that diffracted. Additional efforts to increase the throughput of high-quality crystal generation for MicroED, such as crystallization screening and crystallization chaperone exploration, will be needed to further advance root exudate metabolite identification. The overall optimized sample preparation process can then be integrated with the existing data collection and data analysis pipelines for MicroED at PNNL to facilitate more rapid natural product discovery.

59 BASIC BIOLOGICAL SCIENCES↗

The Physics of Micro-Pinches

This project focused on using pulsed-power-driven techniques to study the coupling of high-energy-density (HED) magnetic fields to HED matter in the laboratory. Specifically, we studied a phenomenon known as "micro-pinching" to obtain HED conditions on a modest, university-scale pulsed-power driver: the 1-MA, 100-ns MAIZE linear transformer driver (LTD) facility at the University of Michigan. We used the "X-pinch" platform as a means of generating micro-pinch HED plasmas. An X-pinch is formed when two or more wires are crossed into the shape of an 'X' and a large electrical current is driven through the wires. This creates an intense electrical current density at the crossing point of the wires. Associated with this current density is an intense magnetic field and an intense magnetic field pressure. The magnetic field pressure compresses and heats the wire material into the HEDP regime. The use of an X-pinch platform ensures that the micro-pinch HED plasma will form in a well-controlled location, which helps with diagnostics alignment. This platform allowed us to explore the extreme plasma conditions and magnetic field pressures that can be generated with compact pulsed-power technology and intensely focused discharge currents. Understanding the limits of intensely focused discharge currents could have an enormous impact on HED science, especially when one considers the scaling of these platforms to the 30-MA Z facility at Sandia National Laboratories, where pressures well in excess of 1 Gbar could be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Research on micro-sized acoustic bandgap structures.

Phononic crystals (or acoustic crystals) are the acoustic wave analogue of photonic crystals. Here a periodic array of scattering inclusions located in a homogeneous host material forbids certain ranges of acoustic frequencies from existence within the crystal, thus creating what are known as acoustic (or phononic) bandgaps. The vast majority of phononic crystal devices reported prior to this LDRD were constructed by hand assembling scattering inclusions in a lossy viscoelastic medium, predominantly air, water or epoxy, resulting in large structures limited to frequencies below 1 MHz. Under this LDRD, phononic crystals and devices were scaled to very (VHF: 30-300 MHz) and ultra (UHF: 300-3000 MHz) high frequencies utilizing finite difference time domain (FDTD) modeling, microfabrication and micromachining technologies. This LDRD developed key breakthroughs in the areas of micro-phononic crystals including physical origins of phononic crystals, advanced FDTD modeling and design techniques, material considerations, microfabrication processes, characterization methods and device structures. Micro-phononic crystal devices realized in low-loss solid materials were emphasized in this work due to their potential applications in radio frequency communications and acoustic imaging for medical ultrasound and nondestructive testing. The results of the advanced modeling, fabrication and integrated transducer designs were that this LDRD produced the 1st measured phononic crystals and phononic crystal devices (waveguides) operating in the VHF (67 MHz) and UHF (937 MHz) frequency bands and established Sandia as a world leader in the area of micro-phononic crystals.

42 ENGINEERING↗

Micro-Kelvin cold molecules.

We have developed a novel experimental technique for direct production of cold molecules using a combination of techniques from atomic optical and molecular physics and physical chemistry. The ability to produce samples of cold molecules has application in a broad spectrum of technical fields high-resolution spectroscopy, remote sensing, quantum computing, materials simulation, and understanding fundamental chemical dynamics. Researchers around the world are currently exploring many techniques for producing samples of cold molecules, but to-date these attempts have offered only limited success achieving milli-Kelvin temperatures with low densities. This Laboratory Directed Research and Development project is to develops a new experimental technique for producing micro-Kelvin temperature molecules via collisions with laser cooled samples of trapped atoms. The technique relies on near mass degenerate collisions between the molecule of interest and a laser cooled (micro-Kelvin) atom. A subset of collisions will transfer all (nearly all) of the kinetic energy from the 'hot' molecule, cooling the molecule at the expense of heating the atom. Further collisions with the remaining laser cooled atoms will thermally equilibrate the molecules to the micro-Kelvin temperature of the laser-cooled atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron-Based Micro-CT Investigation of Oxic Corrosion of Copper-Coated Carbon Steel for Potential Use in a Deep Geological Repository for Used Nuclear Fuel

Within the multi-barrier system proposed for the permanent disposal of used nuclear fuel, the primary engineered barrier is the sealed metallic container. The present Canadian container design utilizes a carbon steel vessel coated with Cu for corrosion protection. In the event of a defect in the Cu coating that exposes the steel substrate, galvanically accelerated corrosion of steel is, in principle, possible. In this work, the progression of corrosion at a simulated through-coating defect in 3.0 mol/L NaCl solution containing dissolved O2 was monitored using electrochemical measurements and imaged non-destructively using synchrotron X-ray micro computed tomography (micro-CT). The damage volume at the base of the simulated defect was measured from the 3D micro-CT data and used to calculate the amount of O2 used to drive steel corrosion. The results demonstrate that the availability of O2 determines the rate and overall extent of corrosion, while the coatings produced using different deposition and treatment methods (cold spray deposition, heat-treated cold spray deposition, electrodeposition) lead to different corrosion propagation geometries, with the distribution of damage depending on the quality of the Cu/steel interface.

Standish, Thalia↗