Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plant Protection System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Implementing a Low-Activity Waste Direct Feed Capability in the Waste Treatment and Immobilization Plant Project - 15594

The current design of the Waste Treatment and Immobilization Plant (WTP) requires that all waste be processed through the Pretreatment (PT) Facility. The U.S. Department of Energy (DOE) has developed a strategic, phased approach to completing the WTP Project, beginning with feeding some liquid waste from the tank farms to the Low-Activity Waste (LAW) Facility, bypassing the PT Facility. To accomplish this, the DOE Office of River Protection (ORP) will construct a new capability outside WTP to remove cesium and solids from the liquid portion of the tank waste before transferring that waste to the LAW Facility. This new capability, referred to as the Low-Activity Waste Pretreatment System, is outside WTP and not included in the project's scope. The primary driver for the Direct-Feed LAW (DFLAW) approach is to enable commissioning of the LAW Facility for low-activity waste processing before the PT and High-Level Waste Facilities are complete and operational. As such, the functions intended to be provided to the LAW Facility by the PT Facility and the common functionality with the High-Level Waste Facility must be refined and modified. The DFLAW approach will provide necessary systems and facilities to replace these enabling PT Facility functions until the PT Facility is completed and commissioned. In February 2014, ORP requested the WTP contractor to develop separate contract modification proposals for completing: (1) the LAW Facility, Balance of Facilities, and Analytical Laboratory work scope in the current contract through hot commissioning in a manner to accommodate a phased start of the WTP mission; and (2) initial planning and design for incorporating a permanent capability to accommodate DFLAW in the WTP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ELECTRONICS UPGRADE TO THE SAVANNAH RIVER NATIONAL LABORATORY COULOMETER FOR PLUTONIUM AND NEPTUNIUM ASSAY

The Savannah River Site (SRS) has the analytical measurement capability to perform high-precision plutonium concentration measurements by controlled-potential coulometry. State-of-the-art controlled-potential coulometers were designed and fabricated by the Savannah River National Laboratory and installed in the Analytical Laboratories process control laboratory. The Analytical Laboratories uses coulometry for routine accountability measurements of and for verification of standard preparations used to calibrate other plutonium measurement systems routinely applied to process control, nuclear safety, and other accountability applications. The SRNL Coulometer has a demonstrated measurement reliability of {approx}0.05% for 10 mg samples. The system has also been applied to the characterization of neptunium standard solutions with a comparable reliability. The SRNL coulometer features: a patented current integration system; continuous electrical calibration versus Faraday's Constants and Ohm's Law; the control-potential adjustment technique for enhanced application of the Nernst Equation; a wide operating room temperature range; and a fully automated instrument control and data acquisition capability. Systems have been supplied to the International Atomic Energy Agency (IAEA), Russia, Japanese Atomic Energy Agency (JAEA) and the New Brunswick Laboratory (NBL). The most recent vintage of electronics was based on early 1990's integrated circuits. Many of the components are no longer available. At the request of the IAEA and the Department of State, SRNL has completed an electronics upgrade of their controlled-potential coulometer design. Three systems have built with the new design, one for the IAEA which was installed at SAL in May 2011, one system for Los Alamos National Laboratory, (LANL) and one for the SRS Analytical Laboratory. The LANL and SRS systems are undergoing startup testing with installation scheduled for this summer.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AP1000{sup R} severe accident features and post-Fukushima considerations

The AP1000{sup R} passive nuclear power plant is uniquely equipped to withstand an extended station blackout scenario such as the events following the earthquake and tsunami at Fukushima without compromising core and containment integrity. The AP1000 plant shuts down the reactor, cools the core, containment and spent fuel pool for more than 3 days using passive systems that do not require AC or DC power or operator actions. Following this passive coping period, minimal operator actions are needed to extend the operation of the passive features to 7 days using installed equipment. To provide defense-in-depth for design extension conditions, the AP1000 plant has engineered features that mitigate the effects of core damage. Engineered features retain damaged core debris within the reactor vessel as a key feature. Other aspects of the design protect containment integrity during severe accidents, including unique features of the AP1000 design relative to passive containment cooling with water and air, and hydrogen management. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Regulatory Considerations for Nuclear Energy Applications of Digital Twin Technologies

Digital twins (DTs) in complex industrial and engineering applications have potential benefits that include increased operational efficiencies, enhanced safety and reliability, improved security engineering, reduced errors, faster information sharing, and better predictions. The interest in DT technologies continues to grow, and many of these advanced technologies are expected to experience rapid and wide industry adoption in the near future. Some of the potential application areas for DTs in the nuclear industry are design, licensing, plant construction, training simulators, predictive operations and maintenance, autonomous operation and control, failure and degradation prediction, physical protection modeling and simulation, and safety and reliability analyses. The Office of Nuclear Regulatory Research at the U.S. Nuclear Regulatory Commission (NRC) has initiated a future-focused research project to assess the regulatory viability of DTs for nuclear power plants and other NRC-regulated activities, such as fuel cycle facilities and operations. This report explores the potential impact of DT technologies in nuclear applications on NRC-regulated activities of interest. This report describes a nuclear DT system and its capabilities for nuclear power plant applications, followed by identification and discussion of some regulated activities that merit special consideration and present opportunities in implementing DT-enabling technologies and capabilities.

99 GENERAL AND MISCELLANEOUS↗

Pretreatment Engineering Platform Phase 1 Final Test Report

Pacific Northwest National Laboratory (PNNL) was tasked by Bechtel National Inc. (BNI) on the River Protection Project, Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to conduct testing to demonstrate the performance of the WTP Pretreatment Facility (PTF) leaching and ultrafiltration processes at an engineering-scale. In addition to the demonstration, the testing was to address specific technical issues identified in Issue Response Plan for Implementation of External Flowsheet Review Team (EFRT) Recommendations - M12, Undemonstrated Leaching Processes.( ) Testing was conducted in a 1/4.5-scale mock-up of the PTF ultrafiltration system, the Pretreatment Engineering Platform (PEP). Parallel laboratory testing was conducted in various PNNL laboratories to allow direct comparison of process performance at an engineering-scale and a laboratory-scale. This report presents and discusses the results of those tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Nuclear Technology. Using Technology for Small Modular Reactor Staff Optimization, Improved Effectiveness, and Cost Containment, 3002007071

Through this grant, the U.S. Department of Energy (DOE) will review several functional areas within a nuclear power plant, including fire protection, operations and operations support, refueling, training, procurement, maintenance, site engineering, and others. Several functional areas need to be examined since there appears to be no single staffing area or approach that alone has the potential for significant staff optimization at new nuclear power plants. Several of the functional areas will require a review of technology options such as automation, remote monitoring, fleet wide monitoring, new and specialized instrumentation, human factors engineering, risk informed analysis and PRAs, component and system condition monitoring and reporting, just in time training, electronic and automated procedures, electronic tools for configuration management and license and design basis information, etc., that may be applied to support optimization. Additionally, the project will require a review key regulatory issues that affect staffing and could be optimized with additional technology input. Opportunities to further optimize staffing levels and staffing functions by selection of design attributes of physical systems and structures need also be identified. A goal of this project is to develop a prioritized assessment of the functional areas, and R&D actions needed for those functional areas, to provide the best optimization

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct-Feed Low-Activity Waste: First Feed Flowsheet - 17108

In support of hot commissioning of the Low-Activity Waste Pretreatment System (LAWPS) and the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW facility, the First Feed Flowsheet was initiated to project process stream characteristics and unit operation performance. The First Feed Flowsheet uses flowsheet models to simulate the preparation of the first feed campaign in Tank Farms and the subsequent feeding of the waste to the Low-Activity Waste Pretreatment System (LAWPS) and the WTP LAW facility. Three different models were used: a chemistry model of waste transfers developed in the Environmental Simulation Program (ESP), Washington River Protection Solutions' (WRPS') dynamic gPROMS{sup TM} LAWPS flowsheet model, and WTP's Dynamic G2 flowsheet model. Information from all three models showed favorable comparison of the waste feeds and secondary liquid wastes against waste compatibility assessment and waste acceptance criteria at multiple stages in the flowsheet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Compact high-resolution gamma-ray computed tomography system for multiphase flow studies

In this paper, a compact high-resolution gamma-ray Computed Tomography (CompaCT) measurement system for multiphase flow studies and tomographic imaging of technical objects is presented. Its compact and robust design makes it particularly suitable for studies on industrial facilities and outdoor applications. Special care has been given to thermal ruggedness, shock resistance, and radiation protection. Main components of the system are a collimated {sup 137}Cs isotopic source, a thermally stabilised modular high-resolution gamma-ray detector arc with 112 scintillation detector elements, and a transportable rotary unit. The CompaCT allows full CT scans of objects with a diameter of up to 130 mm and can be operated with any tilting angle from 0 Degree-Sign (horizontal) to 90 Degree-Sign (vertical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-152: Experimental Validation and Calculation Benchmark for a Commercial Monte Carlo Pencil BeamScanning Proton Therapy Treatment Planning System in Heterogeneous Media

Purpose: Eclipse AcurosPT 13.7, the first commercial Monte Carlo pencil beam scanning (PBS) proton therapy treatment planning system (TPS), was experimentally validated for an IBA dedicated PBS nozzle in the CIRS 002LFC thoracic phantom. Methods: A two-stage procedure involving the use of TOPAS 1.3 simulations was performed. First, Geant4-based TOPAS simulations in this phantom were experimentally validated for single and multi-spot profiles at several depths for 100, 115, 150, 180, 210 and 225 MeV proton beams, using the combination of a Lynx scintillation detector and a MatriXXPT ionization chamber array. Second, benchmark calculations were performed with both AcurosPT and TOPAS in a phantom identical to the CIRS 002LFC, with the exception that the CIRS bone/mediastinum/lung tissues were replaced with similar tissues that are predefined in AcurosPT (a limitation of this system which necessitates the two stage procedure). Results: Spot sigmas measured in tissue were in agreement within 0.2 mm of TOPAS simulation for all six energies, while AcurosPT was consistently found to have larger spot sigma (<0.7 mm) than TOPAS. Using absolute dose calibration by MatriXXPT, the agreements between profiles measurements and TOPAS simulation, and calculation benchmarks are over 97% except near the end of range using 2 mm/2% gamma criteria. Overdosing and underdosing were observed at the low and high density side of tissue interfaces, respectively, and these increased with increasing depth and decreasing energy. Near the mediastinum/lung interface, the magnitude can exceed 5 mm/10%. Furthermore, we observed >5% quenching effect in the conversion of Lynx measurements to dose. Conclusion: We recommend the use of an ionization chamber array in combination with the scintillation detector to measure absolute dose and relative PBS spot characteristics. We also recommend the use of an independent Monte Carlo calculation benchmark for the commissioning of a commercial TPS. Partially supported by Varian Medical System under the master agreement between Varian and University of pennsylvania.

60 APPLIED LIFE SCIENCES↗

Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages over many other bulk electrical tests. Two commercial FDR systems plus a laboratory vector network analyzer are used to test an array of aged and un-aged cables under identical conditions. Several conclusions are set forth, and a number of knowledge gaps are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scan of an Unpublished Report: "Fission Product Behavior During Severe LWR Accidents: Recommendations for the MELCOR Code System"

This document provides a scanned version of a 1987 SAND report that was never formally published. However, this report was referenced within the MELCOR Reference Manual and, therefore, provides historical information and technical basis for the MELCOR code. This document is being made available to permit users of the MELCOR code access to the information. The title page has been edited to prevent any confusion with regards to the possible documentation identifiers, such as the SAND report number or the intended date of publication. Beyond these modifications, a cover, distribution, and back cover are prepended and appended to the document to conform to modern SAND report style guidelines. The first four chapters of this report were updated and released under the title "Fission Product Behavior During Severe LWR Accidents: Recommendations for the MELCOR Code System. Volume I" and were made available by the U.S. NRC through the Adams database under accession number ML19227A327. No prior release of the remaining content of this report has occurred.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New Field Instrument for Leaf Volatiles Reveals an Unexpected Vertical Profile of Isoprenoid Emission Capacities in a Tropical Forest

Both plant physiology and atmospheric chemistry are substantially altered by the emission of volatile isoprenoids (VI), such as isoprene and monoterpenes, from plant leaves. Yet, since gaining scientific attention in the 1950’s, empirical research on leaf VI has been largely confined to laboratory experiments and atmospheric observations. Here, we introduce a new field instrument designed to bridge the scales from leaf to atmosphere, by enabling precision VI detection in real time from plants in their natural ecological setting. With a field campaign in the Brazilian Amazon, we reveal an unexpected distribution of leaf emission capacities (EC) across the vertical axis of the forest canopy, with EC peaking in the mid-canopy instead of the sun-exposed canopy surface, and moderately high emissions occurring in understory specialist species. Compared to the simple interpretation that VI protect leaves from heat stress at the hot canopy surface, our results encourage a more nuanced view of the adaptive role of VI in plants. We infer that forest emissions to the atmosphere depend on the dynamic microenvironments imposed by canopy structure, and not simply on canopy surface conditions. We provide a new emissions inventory from 52 tropical tree species, revealing moderate consistency in EC within taxonomic groups. We highlight priorities in leaf volatiles research that require field-portable detection systems. Our self-contained, portable instrument provides real-time detection and live measurement feedback with precision and detection limits better than 0.5 nmol VI m -2 leaf s -1 . We call the instrument ‘PORCO’ based on the gas detection method: photoionization of organic compounds. We provide a thorough validation of PORCO and demonstrate its capacity to detect ecologically driven variation in leaf emission rates and thus accelerate a nascent field of science: the ecology and ecophysiology of plant volatiles.

54 ENVIRONMENTAL SCIENCES↗

Comparison With Global Soil Radiocarbon Observations Indicates Needed Carbon Cycle Improvements in the E3SM Land Model

We evaluated global soil organic carbon (SOC) stocks and turnover time predictions from a global land model (ELMv1-ECA) integrated in an Earth System Model (E3SM) by comparing them with observed soil bulk and Δ 14 C values around the world. We analyzed observed and simulated SOC stocks and Δ 14 C values using machine learning methods at the Earth System Model grid cell scale (~200 km). In grid cells with sufficient observations, the model provided reasonable estimates of soil carbon stocks across soil depth and Δ 14 C values near the surface but underestimated Δ 14 C at depth. Among many explanatory variables, soil albedo index, soil order, plant function type, air temperature, and SOC content were major factors affecting predicted SOC Δ 14 C values. The influences of soil albedo index, soil order, and air temperature were primarily important in the shallow subsurface (≤30 cm). We also performed sensitivity studies using different vertical root distributions and decomposition turnover times and compared to observed SOC stock and Δ 14 C profiles. The analyses support the role of vegetation in affecting soil carbon turnover, particularly in deep soil, possibly through supplying fresh carbon and degrading physical-chemical protection of SOC via root activities. Allowing for grid cell-specific rooting and decomposition rates substantially reduced discrepancies between observed and predicted Δ 14 C values and SOC content. Furthermore, our results highlight the need for more explicit representation of roots, microbes, and soil physical protection in land models.

58 GEOSCIENCES↗

Annual Energy Outlook 2011 with Projections to 2035

The projections in the Energy Information Administration's (EIA) Annual Energy Outlook 2011 (AEO2011) focus on the factors that shape the U.S. energy system over the long term. Under the assumption that current laws and regulations remain unchanged throughout the projections, the AEO2011 Reference case provides the basis for examination and discussion of energy production, consumption, technology, and market trends and the direction they may take in the future. It also serves as a starting point for analysis of potential changes in energy policies. But AEO2011 is not limited to the Reference case. It also includes 57 sensitivity cases (see Appendix E, Table E1), which explore important areas of uncertainty for markets, technologies, and policies in the U.S. energy economy. Key results highlighted in AEO2011 include strong growth in shale gas production, growing use of natural gas and renewables in electric power generation, declining reliance on imported liquid fuels, and projected slow growth in energy-related carbon dioxide (CO2) emissions even in the absence of new policies designed to mitigate greenhouse gas (GHG) emissions. AEO2011 also includes in-depth discussions on topics of special interest that may affect the energy outlook. They include: impacts of the continuing renewal and updating of Federal and State laws and regulations; discussion of world oil supply and price trends shaped by changes in demand from countries outside the Organization for Economic Cooperation and Development or in supply available from the Organization of the Petroleum Exporting Countries; an examination of the potential impacts of proposed revisions to Corporate Average Fuel Economy standards for light-duty vehicles and proposed new standards for heavy-duty vehicles; the impact of a series of updates to appliance standard alone or in combination with revised building codes; the potential impact on natural gas and crude oil production of an expanded offshore resource base; prospects for shale gas; the impact of cost uncertainty on construction of new electric power plants; the economics of carbon capture and storage; and the possible impact of regulations on the electric power sector under consideration by the U.S. Environmental Protection Agency (EPA). Some of the highlights from those discussions are mentioned in this Executive Summary. Readers interested in more detailed analyses and discussions should refer to the 'Issues in focus' section of this report.

02 PETROLEUM↗

Grande Ronde Basin Fish Habitat Enhancement Project : 2007 Annual Report.

On July 1, 1984 the Bonneville Power Administration and the Oregon Department of Fish and Wildlife entered into an intergovernmental contract to initiate fish habitat enhancement work in the Joseph Creek subbasin of the Grande Ronde River Basin in northeast Oregon. In 1985 the Upper and Middle Grande Ronde River, and Catherine Creek subbasins were included in the contract, and in 1996 the Wallowa River subbasin was added. The primary goal of 'The Grande Ronde Basin Fish Habitat Enhancement Project' is to create, protect, and restore riparian and instream habitat for anadromous salmonids, thereby maximizing opportunities for natural fish production within the basin. This project provided for implementation of Program Measure 703 (C)(1), Action Item 4.2 of the Northwest Power Planning Council's Columbia River Basin Fish and Wildlife Program (NPPC, 1987), and continues to be implemented as offsite mitigation for mainstem fishery losses caused by the Columbia River hydro-electric system. All work conducted by the Oregon Department of Fish and Wildlife and partners is on private lands and therefore requires that considerable time be spent developing rapport with landowners to gain acceptance of, and continued cooperation with this program throughout 10-15 year lease periods. Both passive and active restoration treatment techniques are used. Passive regeneration of habitat, using riparian exclosure fencing and alternate water sources are the primary method to restore degraded streams when restoration can be achieved primarily through changes in management. Active restoration techniques using plantings, bioengineering, site-specific instream structures, or whole stream channel alterations are utilized when streams are more severely degraded and not likely to recover in a reasonable timeframe. Individual projects contribute to and complement ecosystem and basin-wide watershed restoration efforts that are underway by state, federal, and tribal agencies, and coordinated by the Grande Ronde Model Watershed Program (Project. No.199202601). Work undertaken during 2007 included: (1) Starting 1 new fencing project in the NFJD subbasin that will protect an additional 1.82 miles of stream and 216.2 acres of habitat; (2) Constructing 0.47 miles of new channel on the Wallowa River to enhance habitat, restore natural channel dimensions, pattern and profile and reconnect approximately 18 acres of floodplain and wetland habitat; (3) Planting 22,100 plants along 3 streams totaling 3.6 stream miles; (4) Establishing 34 new photopoints on 5 projects and retaking 295 existing photopoint pictures; (5) Monitoring stream temperatures at 10 locations on 5 streams and conducting other monitoring activities; (6) Completing riparian fence, water gap and other maintenance on 116.8 miles of project fences; (7) Initiated writing of a comprehensive project summary report that will present a summary of conclusions of the benefits to focal species and management recommendations for the future. Since initiation of this program 56 individual projects have been implemented, monitored and maintained along 84.8 miles of anadromous fish bearing streams that protect and enhance 3,501 acres of riparian and instream habitat.

13 HYDRO ENERGY↗

TH-AB-209-02: Gadolinium Measurements in Human Bone Using in Vivo K X-Ray Fluorescence (KXRF) Technique

Purpose: Improvement in an in vivo K x-ray fluorescence system, based on 109Cd source, for the detection of gadolinium (Gd) in bone has been investigated. Series of improvements to the method is described. Gd is of interest because of the extensive use of Gd-based contrast agents in MR imaging and the potential toxicity of Gd exposure. Methods: A set of seven bone equivalent phantoms with different amount of Gd concentrations (from 0–100 ppm) has been developed. Soft tissue equivalent plastic plates were used to simulate the soft tissue overlaying the tibia bone in an in vivo measurement. A new 5 GBq 109Cd source was used to improve the source activity in comparison to the previous study (0.17 GBq). An improved spectral fitting program was utilized for data analysis. Results: The previous published minimum detection limit (MDL) for Gd doped phantom measurements using KXRF system was 3.3 ppm. In this study the MDL for bare bone phantoms was found to be 0.8 ppm. Our previous study used only three layers of plastic (0.32, 0.64 and 0.96 mm) as soft tissue equivalent materials and obtained the MDL of 4–4.8 ppm. In this study the plastic plates with more realistic thicknesses to simulate the soft tissue covering tibia bone (nine thicknesses ranging from 0.61–6.13 mm) were used. The MDLs for phantoms were determined to be 1.8–3.5 ppm. Conclusion: With the improvements made to the technology (stronger source, improved data analysis algorithm, realistic soft tissue thicknesses), the MDL of the KXRF system to measure Gd in bare bone was improved by a factor of 4.1. The MDL is at the level of the bone Gd concentration reported in literature. Hence, the system is ready to be tested on human subjects to investigate the use of bone Gd as a biomarker for Gd toxicity.

60 APPLIED LIFE SCIENCES↗

Performance Criteria for Capture and/or Immobilization Technologies (Revision 1)

The capture and subsequent immobilization of regulated volatile radionuclides from the off-gas streams of a used nuclear fuel (UNF) reprocessing facility has been a topic of substantial research interest for the US Department of Energy and its international counterparts. Removal of specific radionuclides from the plant effluent streams before discharge to the environment is required to meet regulations set forth by the US Environmental Protection Agency. Upon removal, the radionuclides, as well as associated sorbents that cannot be regenerated in a cost-effective manner, are destined for conversion to a waste form. Research in separation and capture methodologies has included a wide range of technology types, and studies of waste forms are correspondingly diverse. In considering the future development and implementation of both sorbents and waste forms, it is necessary to identify benchmark measures of performance to objectively evaluate each sorbent system or waste form. Sets of performance criteria and associated metrics have been developed for sorbent and waste form evaluation. These criteria address physical, radiological, and chemical characteristics, technical practicality, technical maturity, cost, and, for sorbents, system performance. The criteria and metrics appear to be robust and should be applicable despite the eventual waste classification (as either high- or low-level waste). They are flexible enough to address both aqueous reprocessing and electrochemical reprocessing of UNF. These criteria sets can serve as tools to evaluate performance at multiple stages within the development process, and in this revision (Revision 1) they have been used to assess technologies relating to krypton/xenon separations and iodine capture from off-gas streams arising from UNF reprocessing. Assessment of krypton/xenon separations using engineered forms of two zeolite minerals (silver mordenite and hydrogen mordenite in a polyacrylonitrile-based binder [AgZ-PAN/HZ-PAN]) found that the zeolite-based separation is relatively advanced in its development, but several key issues require resolution. First, desorption processes for both krypton and xenon require refinement to provide an understanding of the product purity that can be achieved. Second, adsorption rate data is needed in order to calculate the bed depth required for effective separation. Finally, it is strongly recommended that a technical review of krypton/xenon separation by AgZ-PAN/HZ-PAN be performed to synergize available data and assess the cost savings and operational benefits that may be realized from implementation of this technology. Assessment of metal organic frameworks (MOFs) for their use in the separation of krypton/xenon found that the ideal separation would be performed using a single-column system with a MOF selective for krypton over xenon. A robust research effort should work to identify a krypton-selective MOF designed to operate at temperatures of approximately 0°C or higher, which could be preferred over cryogenic krypton/xenon capture for used fuel reprocessing off-gas streams. In the case of the CaSDB-MOF (the most well-understood xenon sorbent to date), two issues are judged of high importance. First, xenon breakthrough capacity for the CaSDB-MOF in prototypical conditions should be determined. Preliminary research indicates that breakthrough may be near immediate, presenting a substantial obstacle in separative system design. Second, development of desorption methodology should be performed to determine regeneration time, energy requirements, and the product stream composition. Silver-based sorbents (AgZ and AgAero) for use in iodine capture from the dissolver off-gas were evaluated against the established criteria. These sorbents are significantly better understood for this application as a result of research efforts over the past decade. The potential implementation of AgAero at a large scale is hindered by its physical degradation by components of the dissolver off-gas stream. Less is known about the adsorption of iodine by these sorbents from other off-gas streams in the plant. Initial experimental efforts have been closely coordinated in an effort to understand organic iodine (such as would be found in the vessel off-gas) adsorption by AgZ and AgAero. Future work should expand this experimental program, and analysis of other reprocessing facility off-gas streams such as the vitrification off-gas stream should be conducted to better understand other potential applications for iodine sorbents. A review of iodine waste form development shows that this area is diverse and that multiple promising waste forms have been identified for the immobilization of radioactive iodine. Efforts related to the direct conversion of iodine sorbents (including AgZ and AgAero) should be continued because of the advantages of direct conversion in a waste management strategy and other sorbents should continue to be advanced as merited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗