Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A reversible Renilla luciferase protein complementation assay for rapid identification of protein-protein interactions reveals the existence of an interaction network involved in xyloglucan biosynthesis in the plant Golgi apparatus

A growing body of evidence suggests that protein–protein interactions (PPIs) occur amongst glycosyltransferases (GTs) required for plant glycan biosynthesis (e.g. cell wall polysaccharides and N-glycans) in the Golgi apparatus, and may control the functions of these enzymes. However, identification of PPIs in the endomembrane system in a relatively fast and simple fashion is technically challenging, hampering the progress in understanding the functional coordination of the enzymes in Golgi glycan biosynthesis. To solve the challenges, we adapted and streamlined a reversible Renilla luciferase protein complementation assay (Rluc-PCA), originally reported for use in human cells, for transient expression in Nicotiana benthamiana. We tested Rluc-PCA and successfully identified luminescence complementation amongst Golgi-localizing GTs known to form a heterodimer (GAUT1 and GAUT7) and those which homooligomerize (ARAD1). In contrast, no interaction was shown between negative controls (e.g. GAUT7, ARAD1, IRX9). Rluc-PCA was used to investigate PPIs amongst Golgi-localizing GTs involved in biosynthesis of hemicelluloses. Although no PPI was identified among six GTs involved in xylan biosynthesis, Rluc-PCA confirmed three previously proposed interactions and identified seven novel PPIs amongst GTs involved in xyloglucan biosynthesis. Notably, three of the novel PPIs were confirmed by a yeast-based split-ubiquitin assay. Finally, Gateway-enabled expression vectors were generated, allowing rapid construction of fusion proteins to the Rluc reporters and epitope tags. In conclusion, our results show that Rluc-PCA coupled with transient expression in N. benthamiana is a fast and versatile method suitable for analysis of PPIs between Golgi resident proteins in an easy and mid-throughput fashion in planta.

59 BASIC BIOLOGICAL SCIENCES↗

Performance evaluation approach for the supercritical helium cold circulators of ITER

The ITER project design foresees Supercritical Helium (SHe) forced flow cooling for the main cryogenic components, namely, the superconducting (SC) magnets and cryopumps (CP). Therefore, cold circulators have been selected to provide the required SHe mass flow rate to cope with specific operating conditions and technical requirements. Considering the availability impacts of such machines, it has been decided to perform evaluation tests of the cold circulators at operating conditions prior to the series production in order to minimize the project technical risks. A proposal has been conceptualized, evaluated and simulated to perform representative tests of the full scale SHe cold circulators. The objectives of the performance tests include the validation of normal operating condition, transient and off-design operating modes as well as the efficiency measurement. A suitable process and instrumentation diagram of the test valve box (TVB) has been developed to implement the tests at the required thermodynamic conditions. The conceptual engineering design of the TVB has been developed along with the required thermal analysis for the normal operating conditions to support the performance evaluation of the SHe cold circulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Bandwidth Low-Inductance Current Shunt for Wide-Bandgap Devices Dynamic Characterization

High bandwidth sensors are required to measure the wide-bandgap devices' transient behavior because of their fast switching speed. In addition to high bandwidth, the current sensor must introduce little extra parasitic inductance to the switching power loop. The analysis of conventional shunt resistors shows the key to high bandwidth is the coaxial structure and its parasitic inductance is proportional to its transient heat energy rating. Additionally, by combining the structure of coaxial shunt resistor and alumina substrate surface mount thin film resistors, a novel surface mount coaxial shunt resistor is introduced. Experimental measurement verifies its capability of achieving very high bandwidth while introducing very low parasitic inductance. The design can achieve up to 2.23-GHz measurement bandwidth while keeping its parasitic inductance as low as 0.12 nH. Application in gallium nitride heterojunction-field-effect-transistors double pulse test shows it can faithfully capture the transient current waveform while introducing little interference to the switching behavior.

42 ENGINEERING↗

High temperature high velocity direct power extraction using an open-cycle oxy-combustion system

The implementation of oxy-fuel technology in fossil-fuel power plants may contribute to increased system efficiencies and a reduction of pollutant emissions. One technology that has potential to utilize the temperature of undiluted oxy-combustion flames is open-cycle magnetohydrodynamic (MHD) power generators. These systems can be configured as a topping cycle and provide high enthalpy, electrically conductive flows for direct conversion of electricity. This report presents the design and modeling strategies of a MHD combustor operating at temperatures exceeding 3000 K. Throughout the study, computational fluid dynamics (CFD) models were extensively used as a design and optimization tool. A lab-scale 60 kWth model was designed, manufactured and tested as part of this project. A fully-coupled numerical method was developed in ANSYS FLUENT to characterize the heat transfer in the system. This study revealed that nozzle heat transfer may be predicted through a 40% reduction of the semi-empirical Bartz correlation. Experimental results showed good agreement with the numerical evaluation, with the combustor exhibiting a favorable performance when tested during extended time periods. A transient numerical method was employed to analyze fuel injector geometries for the 60-kW combustor. The ANSYS FLUENT study revealed that counter-swirl inlets achieve a uniform pressure and velocity ratio when the ports of the injector length to diameter ratio (L/D) is 4. An angle of 115 degrees was found to increase distribution efficiency. The findings show that this oxy-combustion concept is capable of providing a high-enthalpy environment for seeding, in order to render the flow to be conductive. Based on previous findings, temperatures in the range of 2800-3000 K may enable magnetohydrodynamic power extraction. The heat loss fraction in this oxy-combustion system, based on CFD and analytical calculations, at optimal operating conditions, was estimated to be less than 10 percent. Furthermore, the heat transfer design removed approximately 7 MW/m2. The results observed in the lab-scale system were employed to develop a 1-MW scaled prototype. Scaling methods were based on critical design criteria found in similar systems, aimed at replicating combustion flow fields and reducing possible instabilities. A numerical simulation of the combustor wall was developed for a combined thermal steady model and static structural model. This combined model was developed predict combined stress parameters within the wall during testing conditions. Both models were developed within ANSYS FEA software package. The relative accuracy presented as well major performance parameters are discussed to assess the design's validity and ensure safety. The scaled prototype was manufactured through selective laser melting (SLM)-based additive manufacturing to reduce lead times and increase geometrical complexity. Additional CFD models were developed to optimize coolant manifold system parameters and perform a parametric study on channel geometry. An investigation on coolant manifold geometry demonstrated improvements in channel flow distribution when enlarging manifold lengths and increasing the number of tubes feeding into the flow. A three-dimensional model based on a single channel was developed to capture the effect of variable properties and thermal stratification. All cases in the simulation exhibited higher wall temperatures and lower convective coefficients than those determined through 1-D analytical equations. This implies that pressure and velocity safety factors must be implemented during system operation. Overall, the findings made in this investigation are thought to be of value to researchers and industrial practitioners when designing oxy-fuel direct power extraction systems operating at temperatures exceeding 3000 K. In addition to this, the implementation of the developed technology at pilot and commercial scales could result in a significant improvement in the efficiencies of heritage and next-generation power cycles.

03 NATURAL GAS↗

Deep-level transient spectroscopy on an amorphous InGaZnO{sub 4} Schottky diode

The first direct measurement is reported of the bulk density of deep states in amorphous IGZO (indium-gallium-zinc oxide) semiconductor by means of deep-level transient spectroscopy (DLTS). The device under test is a Schottky diode of amorphous IGZO semiconductor on a palladium (Pd) Schottky-barrier electrode and with a molybdenum (Mo) Ohmic contact at the top. The DLTS technique allows to independently measure the energy and spatial distribution of subgap states in the IGZO thin film. The subgap trap concentration has a double exponential distribution as a function energy, with a value of ∼10{sup 19} cm{sup −3} eV{sup −1} at the conduction band edge and a value of ∼10{sup 17} cm{sup −3} eV{sup −1} at an energy of 0.55 eV below the conduction band. Such spectral distribution, however, is not uniform through the semiconductor film. The spatial distribution of subgap states correlates well with the background doping density distribution in the semiconductor, which increases towards the Ohmic Mo contact, suggesting that these two properties share the same physical origin.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparing wall performance predicted from hygrothermal simulations to wall performance measured from environmental chamber experiments

To effectively mitigate prevailing perceptions of potential moisture risks in high-R wall assemblies, a comprehensive moisture durability assessment that incorporates BA team field evaluations, lab tests and simulations has been completed over the last couple years. In FY18, three stick-built walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The measured temperature, relative humidity and moisture content within these walls were compared to WUFI hygrothermal simulation results. In FY19, similar experiments and comparison to WUFI results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The following tasks were completed for these two walls: 1. Measure air permeance of each individual wall using ASTM E283 Standard Test Method. 2.Test walls in diffusion scenario as only moisture transport mechanism and compare measured transient temperature and relative humidity of select wall components to WUFI model results. Chicago summer and weather will be investigated. 3. Test walls in wetting event scenario and compare measured transient temperature and relative humidity of select wall components with Chicago summer weather to WUFI model results. 4. Test walls in diffusion/advection scenario. In addition to controlling outdoor chamber to match real outdoor weather, a pressure differential across the wall will be varied. Measured transient temperature and relative humidity of select wall components will be compared to WUFI model results. 5. Test walls in diffusion/advection with solar heating of cladding. In addition to the variables above, IR lamps will be used to heat the cladding on a diurnal cycle. Measured transient OSB MC and temperature will be compared to WUFI model results. This report documents the experimental method, results and comparison of the measured experimental hygrothermal performance of the two walls to simulations results.

42 ENGINEERING↗

FAST-1.2 User Installation and Verification Guide: Developed Under NQA-1-2017

The purpose of this document is to provide the user information about the installation of Fuel Analysis for Steady state and Transient (FAST)-1.2 on their computers or servers. General information about the code and supported operating systems is described in Section 1.0. Self-service oriented FAST-1.2 software licensing steps are described in Section 2.0. An installation verification test suite is provided with FAST-1.2 and described in Section 3.0. A convenience script for converting Fuel Rod Analysis Program – Constant (FRAPCON) to FAST inputs is discussed in Section 4.0. FAST-1.2 was developed and released under a software quality assurance program based upon NQA-1-2017 at Pacific Northwest National Laboratory (PNNL). FAST-1.2 is the latest baseline code. The installation verification test suite contains both steady state and transient Anticipated Operation Occurrences (AOOs), accident conditions, such as Reactivity Initiated Accidents (RIAs) and Loss of Coolant Accidents (LOCAs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scalable modular dynamic molten salt reactor system model with decay heat

Nodal dynamic models allow rapid reduced-order simulations of complex systems. This paper presents a publicly available system dynamic model of a molten salt reactor system with a topology of the Molten Salt Reactor Experiment (MSRE), in MATLAB/Simulink, building upon a model previously published and validated with MSRE data. It adds scaling of nominal power, dynamic representation of decay heat generation, a generic decay heat removal system, improved documentation, modularity, and test cases. One hour of system transient runs in less than 10 min on a laptop. This model is intended for first order engineering calculations, developing insights into system transient behavior, equipment sizing, parameter sensitivity studies. The model contains an easy to use toolkit which can be customized and expanded to describe any molten salt reactor system. Finally, scenarios involving off-normal transients are presented. Relation between shutdown reactivity insertions, decay heat removal, core recriticality, and safe shutdown conditions are discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lifetime analysis of laser crystallized silicon films on glass

Only recently, the quality of liquid phase crystallized silicon directly on glass substrates made a huge leap towards the quality of multi-crystalline wafers with open circuit voltages well above 600 mV. In this paper, we investigate the material quality in order to identify the factors limiting further performance improvements. We employ photoluminescence imaging on a state of the art test structure with lifetime calibration by transient photoluminescence. The resulting lifetime map is converted into an effective diffusion length map and the origin of regions with short lifetimes is investigated with electron backscattering and transmission electron microscopy. High local dislocation densities in areas with dissociated coincidence site lattice boundaries were found to be responsible for the localised quenching of the photoluminescence signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermophysical properties and conduction mechanisms in As x Se 1-x chalcogenide glasses ranging from x = 0.2 to 0.5

The arsenic (As) to selenium (Se) ratio in As x Se 1-x glasses ranging from x = 0.2 to 0.5 was varied in order to examine the effect of chemical and topological ordering on the glass' thermal transport behavior. The fundamental thermal properties of glass transition temperature (T g ), thermal conductivity (k), and heat capacity (c p ) were experimentally measured using differential scanning calorimetry, transient plane source method, and ultrasonic testing. Based on topological constraint theory, inflections in T g and k were found at the structural coordination number $\langle$r$\rangle$ of 2.4, whereas a slight increase in heat capacity (c p ) with increasing $\langle$r$\rangle$ was observed. A maximum in total thermal conductivity of 0.232 W/m·K was measured for the composition with x = 0.4, which corresponds to the stoichiometric As 2 Se 3 . Gas kinetic theory was used to derive an expression for the photon (k p ) portion of thermal conductivity, which was calculated by measurements of the glass' absorption coefficient (α) and refractive index (n). Models based on Debye theory were then used to derive expressions for specific heat (c v ) and the lattice (k l ) portion of thermal conductivity. The maximum value for k p was 0.173 W/m·K for the composition with x = 0.2, and a minimum value of 0.144 W/m·K was measured for the composition with x = 0.4. Photonic conduction was found to be the dominant carrier mechanisms in all compositions, comprising 60% to 95% of the measured total thermal conductivity.

36 MATERIALS SCIENCE↗

Arabidopsis SEIPIN Proteins Modulate Triacylglycerol Accumulation and Influence Lipid Droplet Proliferation

The lipodystrophy protein SEIPIN is important for lipid droplet (LD) biogenesis in human and yeast cells. In contrast with the single SEIPIN genes in humans and yeast, there are three SEIPIN homologs in Arabidopsis thaliana, designated SEIPIN1, SEIPIN2, and SEIPIN3. Essentially nothing is known about the functions of SEIPIN homologs in plants. Here, a yeast (Saccharomyces cerevisiae) SEIPIN deletion mutant strain and a plant (Nicotiana benthamiana) transient expression system were used to test the ability of Arabidopsis SEIPINs to influence LD morphology. In both species, expression of SEIPIN1 promoted accumulation of large-sized lipid droplets, while expression of SEIPIN2 and especially SEIPIN3 promoted small LDs. Arabidopsis SEIPINs increased triacylglycerol levels and altered composition. In tobacco, endoplasmic reticulum (ER)-localized SEIPINs reorganized the normal, reticulated ER structure into discrete ER domains that colocalized with LDs. N-terminal deletions and swapping experiments of SEIPIN1 and 3 revealed that this region of SEIPIN determines LD size. Ectopic overexpression of SEIPIN1 in Arabidopsis resulted in increased numbers of large LDs in leaves, as well as in seeds, and increased seed oil content by up to 10% over wild-type seeds. By contrast, RNAi suppression of SEIPIN1 resulted in smaller seeds and, as a consequence, a reduction in the amount of oil per seed compared with the wild type. Finally, overall, our results indicate that Arabidopsis SEIPINs are part of a conserved LD biogenesis machinery in eukaryotes and that in plants these proteins may have evolved specialized roles in the storage of neutral lipids by differentially modulating the number and sizes of lipid droplets.

59 BASIC BIOLOGICAL SCIENCES↗

Observation of Electromagnetic Transients in a Nb3Sn 4-layer Dipole Mirror Magnet

During testing of the Stress Managed Cosine-Theta dipole mirror magnet SMCTM1, magnet quenches were observed following large voltage spikes in the half-coil voltage taps which preceded normal quench initiation. Following some recent work at CERN measuring power current converter transients in relation to flux jumps, an additional differential current probe was added to the magnet instrumentation. Measurements of this probe, as well as the half coil voltage taps show a fast and substantial current change preceding the quench, hinting at coil motion. A simple model based on relative shift of the inner and outer layer coils was developed which suggests the magnitude of coil shift events is on the estimated relative coil shift from the magnet constraint conditions. The behavior is shown to be reversible and characteristic of stick-slip.

Krave, Steven [Fermilab] (ORCID:0000000217521457)↗

Results of high heat flux tests of tungsten divertor targets under plasma heat loads expected in ITER and tokamaks (review)

Heat loads on the tungsten divertor targets in the ITER and the tokamak power reactors reach ~10MW m{sup −2} in the steady state of DT discharges, increasing to ~0.6–3.5 GW m{sup −2} under disruptions and ELMs. The results of high heat flux tests (HHFTs) of tungsten under such transient plasma heat loads are reviewed in the paper. The main attention is paid to description of the surface microstructure, recrystallization, and the morphology of the cracks on the target. Effects of melting, cracking of tungsten, drop erosion of the surface, and formation of corrugated and porous layers are observed. Production of submicron-sized tungsten dust and the effects of the inhomogeneous surface of tungsten on the plasma–wall interaction are discussed. In conclusion, the necessity of further HHFTs and investigations of the durability of tungsten under high pulsed plasma loads on the ITER divertor plates, including disruptions and ELMs, is stressed.

36 MATERIALS SCIENCE↗

Low-Cost HTS Based Magnet System with an Inductively Coupled Pulsed Energy Extraction Protection System

In this project, RadiaBeam Technologies was tasked with developing a novel solution for a cost effective quench protection based on fast expansion of the normal zone. By inductively coupling a strong electromagnetic pulse via a resonant LC circuit, we attempted to demonstrate accelerated normal zone propagation. The AC field induces currents in the superconducting layer with the current density exceeding that of the critical current density, J c . This creates a large normal zone, uniformly distributing the dissipation through the magnet body. The method does not rely on thermal heating of the conductor, thus enabling nearly instantaneous protection. Through the course of the Phase II project, RadiaBeam Technologies continued extensive numerical modeling of the inductive quench system, re-designed and built several iterations of the POC system for testing and observed evidence of a transient partial quench being induced. However the final device was not fabricated. This was a consequence of the fundamentally complex nature of the energy extraction process and the challenges associated even with demonstrating the proof of concept in a bench top device.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development and Validation of SAM Multi-dimensional Flow Model for Thermal Mixing and Stratification Modeling

Thermal mixing and stratification in large pools or enclosures are very important phenomena that are critical to nuclear reactor safety. Because of the wide ranges of time and length scales associated with such phenomena, accurate modeling and simulation of thermal mixing and stratification remain as the key unresolved, challenging problems for reactor transient analyses. In traditional system analysis codes, simplified zero-dimensional (0-D) models are widely used for their high numerical efficiency, but they generally suffer from very limited prediction accuracies or range of applicability. Like traditional system analysis codes, the current version of the SAM code has implemented such simplified 0-D and one-dimensional mixing models. On the other hand, high-resolution Computational Fluid Dynamics (CFD) tools are often used to model complex thermal mixing and stratification phenomena. They are, however, generally numerically expensive, and they require large amounts of computational resources. It is therefore desirable to implement advanced and efficient thermal mixing and stratification modeling capabilities embedded in a system analysis code. This approach will improve the accuracy of reactor safety analyses when thermal mixing and stratification are involved, and also avoid using the large computational resources needed for high-resolution CFD analysis. Currently, with the support of the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation program, an effort has been launched to develop and implement a multi-dimensional flow model in the system analysis code SAM, and demonstrate its applications to model thermal mixing and stratification phenomena in large enclosures. The main outcomes of this research and development activity are summarized in this report, which presents an attempt to include a built-in advanced multi-dimensional flow model in a system analysis code with the focus on overcoming the simulation challenges of thermal mixing and stratification phenomena. In this report, we start with the introduction of existing SAM code capabilities to simulate thermal mixing and stratification phenomena, which is followed by a short summary of the multi-dimensional model implemented in the SAM code, including both the physical model and the Finite Element Method code implementation. In this study, two options were implemented in the SAM code to model turbulent flows: a relatively simple built-in turbulence model and an interface to accept externally computed turbulent viscosities (e.g., from a high- resolution CFD simulation). Code validation studies on this newly added capability were then carried out to compare SAM simulation results with experimental data from the SUPERCAVNA facility, which was designed to study the complex flow recirculation and thermal stratification phenomena relevant to sodium fast reactor designs. In this study, one transient and two steady-state test cases were used for code validation. Different approaches have been used to model the complex turbulence flow fields in the SUPERCAVNA facility. A highly simplified zero-equation turbulence model was first used, but it was determined that it is too simple to capture the complex turbulence flow fields in these test cases. Subsequently, the code validation continued with the use of turbulent viscosity data from high-resolution STAR-CCM+ CFD simulations to improve the accuracy of the results. Using this approach, the SAM simulation results showed very good agreement with both the SUPERCAVNA experimental data and STAR-CCM+ simulation results. In this report, we demonstrate the development, implementation, and successful validation of a multi-dimensional flow model in the SAM code, which aims to improve the simulation accuracy for complex thermal mixing and stratification phenomena. Lessons have also been learned, including that in cases where the flow fields are not well predicted by the zero-equation model, the iinput of turbulent viscosities from an external source can enhance the overall predictive capabilities needed to accurately capture complex thermal-hydraulic phenomena. Therefore, future research will be needed to further improve the code’s capabilities, such as by developing a more efficient and robust approach to capture the turbulence effects in the SAM code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrochemical Compression for Ammonia Storage and Refrigeration System (Phase 2)

In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm 2 of active area. We demonstrated the operation of larger cells with 100 cm 2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state.

25 ENERGY STORAGE↗

PHEV Real World Driving Cycle Energy and Fuel and Consumption Reduction Potential for Connected and Automated Vehicles

This paper presents real-world driving energy and fuel consumption results for the second-generation Chevrolet Volt plug-in hybrid electric vehicle (PHEV). A drive cycle, local to Michigan Technological University, was designed to mimic urban and highway driving test cycles in terms of distance, transients and average velocity, but with significant elevation changes to establish an energy intensive real-world driving cycle for assessing potential energy savings for connected and automated vehicle (CAV) control. The investigation began by establishing baseline and repeatability of energy consumption at various battery states of charge. It was determined that drive cycle energy consumption under a randomized set of boundary conditions varied within 3.6% of mean energy consumption regardless of initial battery state of charge. After completing 30 baseline drive cycles, a design for six sigma (DFSS) L18 array was designed to look at sensitivity of a range of parameters to energy consumption as related to connected and automated vehicles to target highest return on engineering development effort. The parameters explored in the DFSS array that showed the most sensitivity, in order of importance, were battery state of charge, vehicle mass, propulsion system thermal conditioning, HVAC setting and driver behavior. Each of these areas are explored for energy savings and discussed briefly in the context of CAV control opportunity for energy savings potential.

33 ADVANCED PROPULSION SYSTEMS↗