Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Design and engineering challenges of a multi-energy hard x-ray camera for long-pulse profile measurements at WEST tokamak

The WEST tokamak has recently been prepared for long pulse operation with a water-cooled full first wall. Heating is provided by radiofrequency systems, including Lower Hybrid Current Drive (LHCD). The Princeton Plasma Physics Laboratory has developed a multi-energy hard x-ray camera for profile measurements at WEST. The camera is based on a new generation of 2D pixel array detectors that allow the energy threshold to be independently set for each pixel. The diagnostic will provide spatial, temporal and energy resolved measurements of the hard x-ray emission from the full plasma cross-section, investigating several physical quantities such as the electron temperature from continuum emission, the fast electron tail density produced by radiofrequency current drive and runaway electrons, as well as characteristic tungsten x-rays due to beam-target emission at the edge. Overall, this work describes the engineering challenges that the WEST long pulse scenario poses for this diagnostic and how the design addresses and solves them. Vacuum, thermal stress and heat transfer calculations are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence

Purpose: To develop and validate a novel delivery strategy for reducing the respiratory motion–induced dose uncertainty of spot-scanning proton therapy. Methods and Materials: The spot delivery sequence was optimized to reduce dose uncertainty. The effectiveness of the delivery sequence optimization was evaluated using measurements and patient simulation. One hundred ninety-one 2-dimensional measurements using different delivery sequences of a single-layer uniform pattern were obtained with a detector array on a 1-dimensional moving platform. Intensity modulated proton therapy plans were generated for 10 lung cancer patients, and dose uncertainties for different delivery sequences were evaluated by simulation. Results: Without delivery sequence optimization, the maximum absolute dose error can be up to 97.2% in a single measurement, whereas the optimized delivery sequence results in a maximum absolute dose error of ≤11.8%. In patient simulation, the optimized delivery sequence reduces the mean of fractional maximum absolute dose error compared with the regular delivery sequence by 3.3% to 10.6% (32.5-68.0% relative reduction) for different patients. Conclusions: Optimizing the delivery sequence can reduce dose uncertainty due to respiratory motion in spot-scanning proton therapy, assuming the 4-dimensional CT is a true representation of the patients' breathing patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional mapping of mineral in intact shark centra with energy dispersive x-ray diffraction

The centra of shark vertebrae consist of cartilage mineralized by a bioapatite similar to bone's carbonated hy-droxyapatite, and, without a repair mechanism analogous to remodeling in bone, these structures still survive millions of cycles of high-strain loading. The main structures of the centrum are an hourglass-shaped double cone and the intermedialia which supports the cones. Little is known about the nanostructure of shark centra, spe-cifically the relationship between bioapatite and cartilage fibers, and this study uses energy dispersive diffraction (EDD) with polychromatic synchrotron x-radiation to study the spatial organization of the mineral phase and its crystallographic texture. The unique energy-sensitive detector array at beamline 6-BM-B, the Advanced Photon Source, enables EDD to quantify the texture within each sampling volume with one exposure while constructing 3D maps via specimen translation across the sampling volume. Herein this study maps a centrum from two shark orders, a carcharhiniform and a lamniform, with different intermedialia structures. In the blue shark (Prionace glauca, Carcharhiniformes), the bioapatite's c-axes are oriented laterally within the centrum's cone walls but axially within the wide wedges of the intermedialia; the former is interpreted to resist lateral deformation, the latter to support axial loads. In the shortfin mako (Isurus oxyrinchus, Lamniformes), there is some tendency for c-axis variation with position, but the situation is unclear because one dimension of the sampling volume is consid-erably larger than the thickness and spacing of the intermedialia's radially-oriented lamellae. Because elastic modulus in collagen plus bioapatite mineralized tissues varies significantly with both volume fraction of bio-apatite and crystallographic texture, the present 3D EDD-derived maps should inform future 3D numerical models of shark centra under applied load.

59 BASIC BIOLOGICAL SCIENCES↗

Nuclear Data Sheets for A = 139

The experimental nuclear spectroscopic data for known nuclides of mass number 139 (Sn, Sb, Te, I, Xe, Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu, Gd, Tb, Dy) have been evaluated and presented together with adopted properties for levels and gamma rays. This evaluation represents a revision of previous one (2001Bu16) by T.W. Burrows. Since then extensive new data have become available for many A=139 nuclides although, no excited state data are yet available for {sup 139}Sn, {sup 139}Sb, {sup 139}Tb, and {sup 139}Dy. The decay schemes of {sup 139}Sn, {sup 139}Sb, {sup 139}I, {sup 139}Tb and {sup 139}Dy nuclei are not known, and those for {sup 139}Gd and {sup 139}Eu are poorly known. Particle-transfer data are available for {sup 139}Ba, {sup 139}La, {sup 139}Ce and {sup 139}Pr. Limited high-spin data are available for {sup 139}Te, {sup 139}I, {sup 139}Cs, {sup 139}Ba, {sup 139}La and {sup 139}Ce, while such data are extensive for {sup 139}Pr, {sup 139}Nd, {sup 139}Pm, {sup 139}Sm, {sup 139}Eu and {sup 139}Gd. Recent {sup 139}Pm high-spin data from two independent studies using the same reaction and similar beam energy are in conflict and could be improved using state-of-the-art large gamma-detector arrays in contrast to the smaller arrays currently used. Cases for which no new experimental information are available since the last update have undergone checking resulting in some changes in the current work, but for the most part these are taken from the previous evaluations. Thus, the present work has greatly benefited from all prior NDS evaluations (2001Bu16, 1989Bu12, 1981Pe04, 1974Gr46), but at the same time data presented herein supersede those in the earlier evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A=189

Evaluated experimental data are presented for 13 known mass 189 nuclides (Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po). Since the 2003Wu02 publication, structure and decay data from 25 new and primary publications have been incorporated in the current work, while adding a new 189 Hf nuclide. New data have been added for all nuclides except 189 Au and 189 Hg. Moreover, several previous datasets were modified for β-decay Q values and conversion coefficients even when no new publications appeared since 2003Wu02. In spite of large amounts of data available for A=189 nuclides, several deficiencies remain, which are pointed out below in the hope that further experimental work may improve our knowledge of structure of these nuclides. For 189 Hf and 189 Ta, ground-state half-lives, and their decay schemes are unknown. An isomer in 189 Ta has recently been established but its decay characteristics are unknown, even though several gamma rays were connected with its decay. No excited states are known in 189 W and only one in 189 Po. The decay scheme of 189 W is known poorly with most gamma rays left as unassigned. The decay schemes of 189 Au and 189 Pb g.s. suffer from incompleteness, while those for the g.s. and isomer of 189 Tl are almost absent. The decay schemes of g.s. and isomer of 189 Hg are very complex as apparent from the study by 1996Wo04. Evaluators feel that these two decay schemes could be improved with modern gamma-ray detector arrays. While several isomers are known in many of the A=189 nuclides, there is in general lack of information of level half-lives, thus limiting the knowledge of transition probabilities. High-spin structures, including SD bands in 189 Hg and 189 Tl, are known in 189 Re, 189 Ir, 189 Pt, 189 Au, 189 Hg, 189 Tl, 189 Pb and 189 Bi. Single-particle transfer data are available for 189 Re, 189 Os, and 189 Pt; and two-neutron transfer data for 189 Ir.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A=64

The evaluated experimental data are presented and evaluated for 13 known nuclides of mass 64 (Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se). For each nuclide, the best values combining all available data are recommended for spectroscopic properties. No excited states have been identified in 64 Ti, 64 As, and 64 Se. Only one excited state in 64 V as an isomer, and three in 64 Cr have been identified. Data for excited states in 64 Mn, 64 Fe, and 64 Co remain limited. 64 Ni, 64 Cu, and 64 Zn are the most studied nuclides through various reactions and decays, followed by 64 Ga and 64 Ge. In the opinion of the evaluators, there are several incomplete or discrepant aspects of the high-spin portion of the level scheme for 64 Zn above ≈5 MeV excitation which need to be resolved in further experiments using large γ-detector arrays. The decay schemes of 64 Ti β - , 64 As ε and 64 Se ε are unknown, while very little information is available for 64 V β - and 64 Cr β - . The decay schemes of 64 Mn β - , 64 Fe β - , 64 Co β - and 64Ge ε are somewhat better known, but still considered incomplete by evaluators. The decay scheme of 64 Ga ε decay is known in detail, however there is the possibility of additional levels populated above 4713 keV, as the Q(ε) value is 7171 keV. The β - , β + and ε decay modes of 64 Cu are well known, as this radionuclide is of great importance in applications, for example, as a dosimeter for neutron flux determination in nuclear reactors, and as a radiopharmaceutical for positron emission tomography (PET). This work supersedes earlier full evaluations of A=64 by 2007Si04, 1996Si12, 1991Si03, 1979Ha35 and 1974Au04.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron and gamma-ray energy reconstruction for characterization of special nuclear material

Characterization of special nuclear material may be performed using energy spectroscopy of either the neutron or gamma-ray emissions from the sample. Gamma-ray spectroscopy can be performed relatively easily using high-resolution semiconductors such as high-purity germanium. Neutron spectroscopy, by contrast, is a complex inverse problem. Here, results are presented for 252 Cf and PuBe energy spectra unfolded using a single EJ309 organic scintillator; excellent agreement is observed with the reference spectra. Neutron energy spectroscopy is also possible using a two-plane detector array, whereby time-offlight kinematics can be used. With this system, energy spectra can also be obtained as a function of position. Finally, spatial-dependent energy spectra are presented for neutron and gamma-ray sources that are in excellent agreement with expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than ± 1% with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 × 4 array of 6 mm × 6 mm × 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of ≈270 e - rms for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8% FWHM at 238 keV and 0.9% FWHM at 662 keV.

3D↗

Rapid simulation of X-ray scatter measurements for threat detection via GPU-based ray-tracing

Scatter-based X-ray imaging has increased in prominence in areas ranging from cancer diagnostics to threat detection in aviation security, due largely to the development of new algorithms and components over the last decade. However, system design and algorithm development are often hindered by an inability to generate a sucient amount of accurate data. To further the development of scatter-based systems, we created a rapid X-ray scatter simulation tool built with a GPU-centric, parallel ray-tracing framework (NVIDIA OptiX). This tool models a full range of X-ray imaging components and describes 3D objects formed with heterogeneous media using polygon meshes. The scatter simulation algorithm we used is similar to the previously-described hybrid approach; however, instead of employing Monte Carlo techniques, we developed a purely analytical algorithm to sample the distribution of single-scatter events throughout the region of interest. The contribution of scattered photons to the measured signal is then calculated using the first-Born approximation. Here, the accuracy of the implemented pipeline has been validated by comparing simulated against experimental data obtained with a laboratory X-ray scattering system and phantoms of varied materials. Using a single desktop computer with an NVIDIA GTX 770 GPU, we show that the scatter signal generated by an incident fan beam and recorded by a 125 125 element detector array can be simulated in on the order of a few to tens of minutes (depending on the object extent and complexity). As a point of comparison, simulations performed via CPU-based Monte Carlo tools, such as GEANT4 (i.e., the gold standard), can take up to tens of hours to achieve comparable results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New insights into the nuclear structure in neutron-rich 112,114,115,116,117,118Pd

New level schemes of 112,114,115,116,117,118Pd are established by means of ?–?–??–?–?, ?–?–?–??–?–?–? and ?–?(0)?–?(0) measurements of prompt fission y rays from 252Cf using the Gammasphere multi-detector array. Spins/parities were assigned to levels based on ?–??–? angular correlation measurements, level systematics and decay patterns. In the even-N isotopes 112,114,116Pd, two sets of odd-parity bands were identified and extended with spins measured in each band. The odd-parity bands with large level staggerings were interpreted as disturbed chirality with less pronounced triaxial deformations in the Pd isotopes than observed in the chiral symmetry breaking 110,112Ru with maximum triaxiality. Onset of wobbling motion was identified from the sign of the signature splitting in the ? band of even–even 114Pd, and probably also in 116Pd, as first seen in the N=68N=68 isotone 112Ru. Maximal triaxiality in Ru and Pd isotopes is found to be reached for N=68N=68, 112Ru and 114Pd, 4 neutrons more than predicted in the theoretical calculations. The new data and TRS calculations allowed a systematic study of the band crossings in the even-N112,114,116Pd and odd-N115,117Pd isotopes. Now we find a new overall, more complex shape evolution than previously proposed from triaxial prolate in 110Pd via triaxial oblate in 112Pd to nearly oblate in 114,116Pd with a large change of the triaxial deformation parameter y toward nearly oblate in the (pi g 9/2)2 alignment in 114,115,116,117,118Pd, and triaxial-prolate–triaxial-oblate shape coexisting bands in 115Pd.

112,114,115,116,117,118Pd↗

Excited states in semi-magic 82 Ge populated in the βn-decay of 83 Ga

For this work, the βn and β-decay of the neutron-rich 83 Ga isotopes produced in proton-induced fission of 238 U were studied at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory using on-line mass separation and the hybrid-3Hen neutron-γ detector array. Excited states in semi-magic 82 Ge populated in βn decay of 83 Ga were identified using neutron-γ coincidences. The measured relative population of excited states in 82 Ge is compared with a βn emission model, where the neutron emission model combines the strength distribution obtained from the shell-model calculations with the statistical Hauser-Feshbach model.

3HEN↗

Direct Reaction Measurements Using GODDESS

GODDESS is a coupling of the charged-particle detection system ORRUBA to the gamma-ray detector array Gammasphere. This coupling has been developed in order to facilitate the high-resolution measurement of direct reactions in normal and inverse kinematics with stable and radioactive beams. GODDESS has been commissioned using a beam of 134 Xe at 10 MeV/A, in a campaign of stable beam measurements. The measurement demonstrates the capabilities of GODDESS under radioactive beam conditions, and provides the first data on the single-neutron states in 135 Xe, including previously unobserved states based on the orbitals above the N=82 shell closure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Energy Spectrum of Cosmic Rays above $10^{18}$ eV Using the Pierre Auger Observatory

We report a measurement of the flux of cosmic rays with unprecedented precision and statistics using the Pierre Auger Observatory. Based on fluorescence observations in coincidence with at least one surface detector we derive a spectrum for energies above 10 18 eV. We also update the previously published energy spectrum obtained with the surface detector array. The two spectra are combined addressing the systematic uncertainties and, in particular, the influence of the energy resolution on the spectral shape. The spectrum can be described by a broken power law E-γ with index γ=3.3 below the ankle which is measured at log10(Eankle/eV)=18.6 . Above the ankle the spectrum is described by a power law with index 2.6 followed by a flux suppression, above about log10(E/eV)=19.5 , detected with high statistical significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Grains and Strains from Cepstral Analysis of 4D-STEM Nano-Diffraction Datasets

We report the availability of fast, high dynamic range pixel array detectors makes scanning convergent beam electron diffraction (CBED) a powerful tool for rapid, spatially resolved characterization of lattice structure over a wide range of length scales. However, to extract useful structural information from the large 4-dimensional datasets, especially for complex, 3D specimens, we must confront challenges with CBED intensity variations due to crystal mistilts and multiple scattering as well as challenges with precisely localizing diffracted disk centers.

36 MATERIALS SCIENCE↗

Continuous Simultaneous Detection in Mass Spectrometry

In mass spectrometry, several advantages can be derived when multiple mass-to-charge values are detected simultaneously. One such advantage is an improved duty cycle, which leads to superior limits of detection, better precision, shorter analysis times, and reduced sample sizes. A second advantage is the ability to reduce correlated noise by taking the ratio of two or more simultaneously collected signals, enabling greatly enhanced isotope ratio data. A final advantage is the elimination of spectral skew, leading to more accurate transient signal analysis. Here, these advantages are demonstrated by means of a novel Faraday-strip array detector coupled to a Mattauch-Herzog mass spectrograph. The same system is used to monitor elemental fractionation phenomena in laser ablation inductively coupled plasma mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Characterization of Brown Carbon in Biomass Burning Aerosol Particles

Emissions from biomass burning are a significant source of brown carbon (BrC) in the atmosphere. In this study, we investigate the molecular composition of freshly-emitted biomass burning organic aerosol (BBOA) samples collected during test burns of selected biomass fuels: sawgrass, peat, ponderosa pine, and black spruce. We characterize individual BrC chromophores present in these samples using high performance liquid chromatography coupled to a photodiode array detector and a high-resolution mass spectrometer. We demonstrate that both the overall BrC absorption and the chemical composition of light-absorbing compounds depend significantly on the type of biomass fuels and burning conditions. Common BrC chromophores in the selected BBOA samples include nitro-aromatics, polycyclic aromatic hydrocarbon derivatives, and polyphenols spanning a wide range of molecular weights, structures, and light absorption properties. A number of biofuel-specific BrC chromophores are observed, indicating that some of them may be used as potential markers of BrC originating from different biomass burning sources. On average, ~50% of the light absorption above 300 nm can be attributed to a limited number of strong BrC chromophores, which may serve as representative light-absorbing species for studying atmospheric processing of BrC aerosol. The absorption coefficients of BBOA are affected by solar photolysis. Specifically, under typical atmospheric conditions, the 300 nm absorbance decays with a half-life of 16 hours. A “molecular corridors” analysis of the BBOA volatility distribution suggests that many BrC compounds in the fresh BBOA have low volatility (<1 g m-1) and will be retained in the particle phase under atmospherically relevant conditions.

Environmental Molecular Sciences Laboratory↗

Mechanistic Insights into Superlattice Transformation at a Single Nanocrystal Level Using Nanobeam Electron Diffraction

Understanding the mechanism and ultimately directing nanocrystal (NC) superlattice assembly and attachment have important implications on future advances in this emerging field. Here, we use 4D-STEM to investigate a monolayer of PbS NCs at various stages of the transformation from a hexatic assembly to a nonconnected square-like superlattice over large fields of view. Maps of nanobeam electron diffraction patterns acquired with an electron microscope pixel array detector (EMPAD) offer unprecedented detail into the 3D crystallographic alignment of the polyhedral NCs. Our analysis reveals that superlattice transformation is dominated by translation of prealigned NCs strongly coupled along the <11n>AL direction and occurs stochastically and gradually throughout single grains. We validate the generality of the proposed mechanism by examining the structure of analogous PbSe NC assemblies using conventional transmission electron microscopy and selected area electron diffraction. Here, the experimental results presented here provide new mechanistic insights into NC self-assembly and oriented attachment.

36 MATERIALS SCIENCE↗

Fluorescence Correlation Spectroscopy at Micromolar Concentrations without Optical Nanoconfinement

Fluorescence correlation spectroscopy (FCS) is an important technique for studying biochemical interactions dynamically that may be used in vitro and in cell-based studies. It is generally claimed that FCS may only be used at nM concentrations. We show that this general consensus is incorrect and that the limitation to nM concentrations is not fundamental but due to detector limits as well as laser fluctuations. With a high count rate detector system and applying laser fluctuation corrections, we demonstrate FCS measurements up to 38 μM with the same signal-to-noise as at lower concentrations. Optical nanoconfinement approaches previously used to increase the concentration range of FCS are not necessary, and further increases above 38 μM may be expected using detectors and detector arrays with higher saturation rates and better laser fluctuation corrections. This approach greatly widens the possibilities of dynamic measurements of biochemical interactions using FCS at physiological concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗