Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Synchrotron radiation x-ray topography and defect selective etching analysis of threading dislocations in GaN

The crystal quality of bulk GaN crystals is continuously improving due to advances in GaN growth techniques. Defect characterization of the GaN substrates by conventional methods is impeded by the very low dislocation density and a large scale defect analysis method is needed. White beam synchrotron radiation x-ray topography (SR-XRT) is a rapid and non-destructive technique for dislocation analysis on a large scale. In this study, the defect structure of an ammonothermal c-plane GaN substrate was recorded using SR-XRT and the image contrast caused by the dislocation induced microstrain was simulated. The simulations and experimental observations agree excellently and the SR-XRT image contrasts of mixed and screw dislocations were determined. Apart from a few exceptions, defect selective etching measurements were shown to correspond one to one with the SR-XRT results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analytical (S)TEM Studies of Defects Associated with PID in Stressed Si PV Modules

We report the results of analytical transmission electron microscopy studies of defects associated with potentialinduced degradation (PID) of a laboratory stressed multicrystalline silicon mini-module. Shunt defects were first identified using dark lock in thermography (DLIT) and scanning electron microscopy (SEM) electron beam induced current (EBIC) imaging. Transmission electron microscopy (TEM) crosssection samples were then prepared of selected shunt defects using conventional focused ion beam (FIB) lift out techniques and examined by TEM and scanning transmission electron microscopy (STEM). The defects were identified as {111} planar defects and compositional mapping of the defects revealed elevated levels of both Na, expected from previous work, and also surprisingly O at some of the defect cores.

14 SOLAR ENERGY↗

Comparison of Shadowgraphy and X-Ray Phase Contrast Methods for Characterizing a DT Ice Layer in an Inertial Confinement Fusion Target

Shadowgraphy and x-ray phase contrast (XPC) imaging are two techniques that are used for characterizing the deuterium-tritium ice layer in Inertial Confinement Fusion targets. Each technique has limitations that affect how accurately they can characterize small crystalline defects and measure the ice-thickness non-uniformities that may be only a few micrometers in height. The concern is that shadowgraphy may be overly sensitive to the shape and depth of defects in the surface and insufficiently sensitive to the shape of longer-wavelength roughness, while x-ray phase contrast may be too insensitive to defects in the ice surface. Multiple ice layers with different thicknesses (40 to 63 μm), thickness uniformities (peak-valley variations that range from <2- to 12 μm), and crystal defects were analyzed using shadowgraphy and x-ray phase contrast techniques. The results from each method agree when the ice layer is uniformly thick and the crystal lacks defects. That agreement worsens as the number of defects in the surface of the ice layer increases and the roughness that is determined from a shadowgram image of the target’s limb is greater than can be justified by the number of defects that are seen in the target’s front and rear surfaces. The XPC technique is considerably less sensitive to surface defects, in part due to the poorer dynamic range and image resolution compared to shadowgraphy. Localized regions of the ice layer that are thicker or thinner than the average thickness of the layer are reported by shadowgraphy to be smaller in height and footprint (by up to 30%) than by XPC. As a result, the two techniques report different ice layer thicknesses that can vary by up to 10%. Shadowgraphy results from two caustics that trace different paths through the target, and, in theory, image the same ice-vapor surface (but reflect from either the vapor or ice side of the interface) did not consistently characterize the size or shape of ice features to be the same magnitude. Here, the XPC technique provides the best assessment of low-mode (l < 7) roughness in the ice layer. Shadowgraphy results using the strongest caustic is best for detecting the presence of grooves in the ice, though not for quantifying the size of them. If multiple grooves are present it is best to discard and reform the ice layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The application of an optical Fourier spectrum analyzer on detecting defects in mass-produced satellite photographs

Various defects in mass-produced pictures transmitted to earth from a satellite are investigated. It is found that the following defects are readily detectable via Fourier spectrum analysis: (1) bit slip, (2) breakup causing loss of image, and (3) disabled track at the top of the imagery. The scratches made on the film during mass production, which are difficult to detect by visual observation, also show themselves readily in Fourier spectrum analysis. A relation is established between the number of scratches, their width and depth and the intensity of their Fourier spectra. Other defects that are found to be equally suitable for Fourier spectrum analysis or visual (image analysis) detection are synchronous loss without blurring of image, and density variation in gray scale. However, the Fourier spectrum analysis is found to be unsuitable for detection of such defects as pin holes, annotation error, synchronous loss with blurring of images, and missing image in the beginning of the work order. The design of an automated, real time system, which will reject defective films, is treated.

Athale, R.↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localized UV emitters on the surface of β-Ga 2 O 3

Abstract Monoclinic gallium oxide (β-Ga 2 O 3 ) is attracting intense focus as a material for power electronics, thanks to its ultra-wide bandgap (4.5–4.8 eV) and ability to be easily doped n -type. Because the holes self-trap, the band-edge luminescence is weak; hence, β-Ga 2 O 3 has not been regarded as a promising material for light emission. In this work, optical and structural imaging methods revealed the presence of localized surface defects that emit in the near-UV (3.27 eV, 380 nm) when excited by sub-bandgap light. The PL emission of these centers is extremely bright—50 times brighter than that of single-crystal ZnO, a direct-gap semiconductor that has been touted as an active material for UV devices.

36 MATERIALS SCIENCE↗

Matrix phased arrays for the inspection of CFRP-components

Lightweight components are increasingly used in different industrial sectors such as transportation, energy generation and automotive. This growing field includes different types of CFRP-structures, hybrid materials and glued components showing - compared to their pure metallic counterparts- a significant more complicated structure in terms of internal interfaces and anisotropy of material parameters. In this work we present the use of matrix phased array to increase the amount of obtained information to enhance the inspection quality. We used different types of carbon materials such as 6 mm thick uni- and bidirectional prepreg specimens containing impact damages. The latter were introduced with different energy levels ranging from 1.3 to 7.2 J. By scanning a 2.25 MHz matrix array with 6 × 10 elements above the prepreg surface and using different angels of incidence a complete 3D-image was generated which allows the detection of defects as small as 1mm in a depth of 4 mm. A comparison with conventional approaches show that the signal-to-noise ratio can be highly increased. This enables us to visualize the region of damage within the impact zone, clearly showing the cone-like damage distribution along increasing material depth. The detection quality allows the estimation of the opening angles of the cone shaped damage, which can be used for further evaluation and quantitation of energy dependent impact damages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust frequency diversity based algorithm for clutter noise reduction of ultrasonic signals using multiple sub-spectrum phase coherence

This paper presents a robust frequency diversity based algorithm for clutter reduction in ultrasonic A-scan waveforms. The performance of conventional spectral-temporal techniques like Split Spectrum Processing (SSP) is highly dependent on the parameter selection, especially when the signal to noise ratio (SNR) is low. Although spatial beamforming offers noise reduction with less sensitivity to parameter variation, phased array techniques are not always available. The proposed algorithm first selects an ascending series of frequency bands. A signal is reconstructed for each selected band in which a defect is present when all frequency components are in uniform sign. Combining all reconstructed signals through averaging gives a probability profile of potential defect position. To facilitate data collection and validate the proposed algorithm, Full Matrix Capture is applied on the austenitic steel and high nickel alloy (HNA) samples with 5MHz transducer arrays. When processing A-scan signals with unrefined parameters, the proposed algorithm enhances SNR by 20dB for both samples and consequently, defects are more visible in B-scan images created from the large amount of A-scan traces. Importantly, the proposed algorithm is considered robust, while SSP is shown to fail on the austenitic steel data and achieves less SNR enhancement on the HNA data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of nanoscale embedded layers using laboratory specular X-ray diffraction

Unusual specular X-ray diffraction patterns have been observed from certain thin film intergrowths of metal monochalcogenide (MX) and transition metal dichalcogenide (TX{sub 2}) structures. These patterns exhibit selective “splitting” or broadening of selected (00l) diffraction peaks, while other (00l) reflections remain relatively unaffected [Atkins et al., Chem. Mater. 24, 4594 (2012)]. Using a simplified optical model in the kinematic approximation, we illustrate that these peculiar and somewhat counterintuitive diffraction features can be understood in terms of additional layers of one of the intergrowth components, MX or TX{sub 2}, interleaved between otherwise “ideal” regions of MX-TX{sub 2} intergrowth. The interpretation is in agreement with scanning transmission electron microscope imaging, which reveals the presence of such stacking “defects” in films prepared from non-ideal precursors. In principle, the effect can be employed as a simple, non-destructive laboratory probe to detect and characterize ultrathin layers of one material, e.g., 2-dimensional crystals, embedded between two slabs of a second material, effectively using the two slabs as a highly sensitive interferometer of their separation distance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanisms for long carrier lifetime in Cd(Se)Te double heterostructures

II–VI semiconductors are used in numerous electro-optical applications. For example, CdTe-based solar technology is cost competitive with other electricity generation sources, yet there is still significant room to improve. Carrier lifetime has historically been well below the radiative recombination limit. Lifetimes reaching beyond 100 ns can significantly enhance performance and enable novel device structures. Here, double heterostructures (DHs) with passivated interfaces demonstrate lifetimes exceeding 1 µs, yet this appears only for CdSeTe and not for CdTe DHs. We compare the passivation mechanisms in CdTe and CdSeTe DHs. CdSeTe lifetimes on the order of 1 µs correspond to a combination of superior intragrain lifetime, extremely low grain boundary recombination and greater Te4+ interfacial presence compared to CdTe.

36 MATERIALS SCIENCE↗

Aspherical Electron Scattering Factors and Their Parameterizations for Elements from H to Xe

The formalism for, and the values of, aspherical electron scattering factors using relativistic wavefunctions are presented. The parameterizations of electron form factors valid for a full range of scattering vectors from 0.0 to 6.0 {angstrom}{sup -1} were obtained for atoms with atomic number 1 (H) to 54 (Xe) by fitting a linear combination of Gaussian functions. Eight Gaussians were needed to achieve high-quality fittings. The tabulated aspherical p- and d-orbital parameters are invaluable for probing orbital electrons and calculating high-resolution electron microscopy images and diffractions, especially those involving interfaces and defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electroluminescence Analysis and Grading of Hail Damaged Solar Panels

We analyzed more than 4000 electroluminescence images of hail damaged solar panels from a cluster of houses in Texas. We enhanced the images for ease of analysis and classified the defects within each solar cell into categories of glass breakage, installer damage, inactive substrings, crack severity, interconnect wire problems, and whether the damage was likely caused by hail. From these statistics, we quantified each panel into five levels of hail damage for insurance claims, and four levels of overall quality for potential resale pricing. Here, we share here some statistics regarding the defects with the hope that the data is useful to others attempting to predict the invisible damage to systems based just on the easily observable glass breakage statistics.

14 SOLAR ENERGY↗

Beam Hardening Artifact Reduction in X-Ray CT Reconstruction of 3D Printed Metal Parts Leveraging Deep Learning and CAD Models

Nondestructive evaluation (NDE) of additively manufactured (AM) parts is important for understanding the impacts of various process parameters and qualifying the built part. X-ray computed tomography (XCT) has played a critical role in rapid NDE and characterization of AM parts. However, XCT of metal AM parts can be challenging because of artifacts produced by standard reconstruction algorithms as a result of a confounding effect called “beam hardening.” Beam hardening artifacts complicate the analysis of XCT images and adversely impact the process of detecting defects, such as pores and cracks, which is key to ensuring the quality of the parts being printed. In this work, we propose a novel framework based on using available computer-aided design (CAD) models for parts to be manufactured, accurate XCT simulations, and a deep-neural network to produce high-quality XCT reconstructions from data that are affected by noise and beam hardening. Using extensive experiments with simulated data sets, we demonstrate that our method can significantly improve the reconstruction quality, thereby enabling better detection of defects compared with the state of the art. We also present promising preliminary results of applying the deep networks trained using CAD models to experimental data obtained from XCT of an AM jet-engine turbine blade.

Ziabari, Amir↗

Assessment of three dead detector correction methods for cone-beam computed tomography

Purpose: Dead detectors due to manufacturing defects or radiation damage in the electronic portal imaging devices (EPIDs) used for cone-beam computed tomography (CBCT) can lead to image degradation and ring artifacts. In this work three dead detector correction methods were assessed using megavoltage CBCT (MVCBCT) as a test system, with the goals of assessing the relative effectiveness of the three methods and establishing the conditions for which they fail. Methods: MVCBCT projections acquired with four linacs at 8 and 60 MU (monitor units) were degraded with varying percentages (2%-95%) of randomly distributed dead single detectors (RDSs), randomly distributed dead detector clusters (RDCs) of 2 mm diameter, and nonrandomly distributed dead detector disks (NRDDs) of varying diameter (4-16 mm). Correction algorithms were bidirectional linear interpolation (BLI), quad-directional linear interpolation (QLI), and a Laplacian solution (LS) method. Correction method failure was defined to occur if ring artifacts were present in the reconstructed phantom images from any linac or if the modulation transfer function (MTF) for any linac dropped below baseline with a p value, calculated with the two sample t test, of less than 0.01. Results: All correction methods failed at the same or lower RDC/RDS percentages and NRDD diameters for the 60 MU as for the 8 MU cases. The LS method tended to outperform or match the BLI and QLI methods. If ring artifacts anywhere in the images were considered unacceptable, the LS method failed for 60 MU at >33% RDS, >2% RDC, and >4 mm NRDD. If ring artifacts within 4 mm longitudinally of the phantom section interfaces were considered acceptable, the LS method failed for 60 MU at >90% RDS, >80% RDC, and >4 mm NRDD. LS failed due to MTF drop for 60 MU at >50% RDS, >25% RDC, and >4 mm NRDD. Conclusions: The LS method is superior to the BLI and QLI methods, and correction algorithm effectiveness decreases as imaging dose increases. All correction methods failed first due to ring artifacts and second due to MTF drop. If ring artifacts in axial slices within a 4 mm longitudinal distance from phantom section interfaces are acceptable, statistically significant loss in spatial resolution does not occur until over 25% of the EPID is covered in randomly distributed dead detectors, or NRDDs of 4 mm diameter are present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic relaxation in GeSi layers on Si (001) and Si (115) substrates

It is demonstrated using X-ray diffraction and atomic force microscopy that elastic stresses in GeSi layers on Si (115) substrates relax more effectively than in the same layers on Si (001) substrates. This fact is attributed to the predominant contribution of one of the (111) slip planes on the (115) cut. The atomicforce-microscopy image of the GeSi/Si(115) surface reveals unidirectional slip planes, while the GeSi/Si(001) image contains a grid of orthogonal lines and defects at the points of their intersection. As a result, thick GeSi layers on Si (115) have a reduced surface roughness. A technique for calculating the parameters of relaxation of the layer on the Si (115) substrate using X-ray diffraction data is discussed.

36 MATERIALS SCIENCE↗

CryoTARPOS Vibration Mitigation System for Layered Experiments

The goal of this project is to implement a system that can eliminate or mitigate vibration so that clear images can be taken without bypassing the cryocooler. By allowing for layer characterization and cryocooler operation at the same time, cooling capacity and thermal stability of the target would be improved, and more layer characterization data could be taken. Increased cooling capacity and thermal stability could allow for layering during occasional off normal conditions that would typically result in a loss of temperature control and NIF operational delays ranging from several hours to several days per month. The increased cooling capacity and thermal stability could also allow for layering of new target platforms that have less cooling margin. Additional layer images could be used for better characterization of defects and non-uniformities in the layer and would reduce the likelihood of layer seed loss, which typically adds ~12 hours per week in layering time. Motion blur from vibration due to off normal activity in the NIF Target Bay could also be mitigated that would usually result in NIF operational delays of several hours every month.

42 ENGINEERING↗

“Seeing Is Believing”—In-Depth Analysis by Co-Imaging of Periodically-Poled X-Cut Lithium Niobate Thin Films

Nonlinear and quantum optical devices based on periodically-poled thin film lithium niobate (PP-TFLN) have gained considerable interest lately, due to their significantly improved performance as compared to their bulk counterparts. Nevertheless, performance parameters such as conversion efficiency, minimum pump power, and spectral bandwidth strongly depend on the quality of the domain structure in these PP-TFLN samples, e.g., their homogeneity and duty cycle, as well as on the overlap and penetration depth of domains with the waveguide mode. Hence, in order to propose improved fabrication protocols, a profound quality control of domain structures is needed that allows quantifying and thoroughly analyzing these parameters. In this paper, we propose to combine a set of nanometer-to-micrometer-scale imaging techniques, i.e., piezoresponse force microscopy (PFM), second-harmonic generation (SHG), and Raman spectroscopy (RS), to access the relevant and crucial sample properties through cross-correlating these methods. Based on our findings, we designate SHG to be the best-suited standard imaging technique for this purpose, in particular when investigating the domain poling process in x-cut TFLNs. While PFM is excellently recommended for near-surface high-resolution imaging, RS provides thorough insights into stress and/or defect distributions, as associated with these domain structures. In this context, our work here indicates unexpectedly large signs for internal fields occurring in x-cut PP-TFLNs that are substantially larger as compared to previous observations in bulk LN.

Reitzig, Sven (ORCID:0000000286970379)↗