At least 595 records · Page 33

Total dose bias dependency and ELDRS effects in bipolar linear devices

Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.

ELDRS voltage regulator voltage reference↗

New Technology for Microfabrication and Testing of a Thermoelectric Device for Generating Mobile Electrical Power

We report the results of fabrication and testing of a thermoelectric power generation module. The module was fabricated using a new "flip-chip" module assembly technique that is scalable and modular. This technique results in a low value of contact resistivity ( < or = 10(exp 5) Ohms-sq cm). It can be used to leverage new advances in thin-film and nanostructured materials for the fabrication of new miniature thermoelectric devices. It may also enable monolithic integration of large devices or tandem arrays of devices on flexible or curved surfaces. Under mild testing, a power of 22 mW/sq cm was obtained from small (<100 K) temperature differences. At higher, more realistic temperature differences, approx.500 K, where the efficiency of these materials greatly improves, this power density would scale to between 0.5 and 1 Watt/cm2. These results highlight the excellent potential for the generation and scavenging of electrical power of practical and usable magnitude for remote applications using thermoelectric power generation technologies.

Prasad, Narashimha S.↗

REALIZATION OF A AUTOMATED T-WAY COMBINATORIAL TESTING APPROACH FOR A SOFTWARE BASED EMBEDDED DIGITAL DEVICE

Under the Department of Energy’s Light Water Reactor Sustainability Program, within the Plant Modernization research pathway, the Digital I&C Qualification Project is identifying new methods that would be beneficial in qualifying digital I&C systems and devices for safety-related usage. One such method that would be useful in qualifying field components such as sensors and actuators is the concept of testability. The Nuclear Regulatory Commission (NRC) considers testability to be one of two design attributes sufficient to eliminate consideration of software-based or software logic-based common cause failure (the other being diversity). The NRC defines acceptable “testability” as follows: Testability – A system is sufficiently simple such that every possible combination of inputs and every possible sequence of device states are tested and all outputs are verified for every case (100% tested). [NUREG 0800, Chapter 7, Branch Technical Position (BTP) 7-19] This qualification method has never proven to be practical in view of the very large number of combinations of inputs and sequences of device states for a typical I&C device. However, many of these combinations are not unique in the sense that they represent the same state space or in that that they represent state space that would not affect the critical design basis functions of the device. Therefore, the state space of interest might possibly be reduced to a manageable dimension through such analysis. This project will focus on a representative I&C device similar in design, function, and complexity to the types of devices that would likely be deployed in nuclear power plants as digital or software based sensors and actuators (e.g. Smart Sensors). Analysis will be conducted to determine the feasibility of testing this device in a manner consistent with the NRC definition. This report describes the development of test process for Bounded Exhaustive Testing with respect to Combinatorial Test (CT) methods. The report describes the candidate Device Under Test SW – the VCU smart sensor, conceptual experimental methods for stated test objectives, description of the process, tools, resources, and computing. This information will be used to fully develop a detailed test plan (based on statistical measure needs) and test environment for conducting an I&C device testability demonstration study. The future planed experimental study of this project is to demonstrate digital qualification via Bounded Exhaustive Testability with respect to Common Cause Failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impedance Based Fixture Neutralization (FINE) Method to Replicate Field Environments in Laboratory Settings

Test article vibration test responses will vary from one test laboratory to another due to differences in shaker and fixture dynamic characteristics. This is also seen between the field and laboratory due to the differing dynamic characteristics between field assembly loading and boundary conditions compared to the laboratory configuration. This work introduces a technique called Impedance Fixture Neutralization which customizes input forces to cause consistent responses for the Device Under Test across different vibration testing conditions. The customized force neutralizes the dynamic variations between configurations for the Device Under Test. The device responses can be replicated in several situations: when using a different fixture with the same attachment points, when the test article mounting location on the fixture changes, when the force location changes, or any combination of these situations. Impedance Fixture Neutralization uses the uncoupled dynamic characteristics of the test article and excitation fixtures to customize the input thereby causing the same test article responses between two mounting configurations (either field to laboratory or two different laboratory configurations). The application of the technique is shown using an analytical model of a two-beam system and analytically using experimental FRFs from plate and frame component hardware characterization tests. In both cases a device under test is attached to two test fixtures wherein the dynamic differences in the configurations are neutralized.

Laboratory↗

Cryogenic User Facilities for R&D on Noble Liquid Detectors and Low Temperature Devices

Cryogenic test facilities are critical infrastructure for physics experiments in a variety of fields, perhaps most notably for particle detection with noble liquid detectors, low-temperature device development, and quantum information research. However, considerable investment and technical knowledge are required to construct and operate such facilities. This white paper discusses proposals for user facilities aimed at broadening the availability of testing capabilities for the scientific community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers

A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population

59 BASIC BIOLOGICAL SCIENCES↗

Initial Results from On-Orbit Testing of the Fram Memory Test Experiment on the Fastsat Micro-Satellite

The Memory Test Experiment is a space test of a ferroelectric memory device on a low Earth orbit satellite that launched in November 2010. The memory device being tested is a commercial Ramtron Inc. 512K memory device. The circuit was designed into the satellite avionics and is not used to control the satellite. The test consists of writing and reading data with the ferroelectric based memory device. Any errors are detected and are stored on board the satellite. The data is sent to the ground through telemetry once a day. Analysis of the data can determine the kind of error that was found and will lead to a better understanding of the effects of space radiation on memory systems. The test is one of the first flight demonstrations of ferroelectric memory in a near polar orbit which allows testing in a varied radiation environment. The initial data from the test is presented. This paper details the goals and purpose of this experiment as well as the development process. The process for analyzing the data to gain the maximum understanding of the performance of the ferroelectric memory device is detailed.

MacLeond, Todd C.↗

Passive safety device and internal short tested method for energy storage cells and systems

A passive safety device for an energy storage cell for positioning between two electrically conductive layers of the energy storage cell. The safety device also comprising a separator and a non-conductive layer. A first electrically conductive material is provided on the non-conductive layer. A first opening is formed through the separator between the first electrically conductive material and one of the electrically conductive layers of the energy storage device. A second electrically conductive material is provided adjacent the first electrically conductive material on the non-conductive layer, wherein a space is formed on the non-conductive layer between the first and second electrically conductive materials. A second opening is formed through the non-conductive layer between the second electrically conductive material and another of the electrically conductive layers of the energy storage device. The first and second electrically conductive materials combine and exit at least partially through the first and second openings to connect the two electrically conductive layers of the energy storage device at a predetermined temperature.

25 ENERGY STORAGE↗

OpenSim Model Improvements to Support High Joint Angle Resistive Exercising

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Rigorous testing of these proposed devices in space flight is difficult so computational modeling provides an estimation of the muscle forces and joint loads during exercise to gain insight on the efficacy to protect the musculoskeletal health of astronauts. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts

Bioengineering↗

Electrostatic testing of thin plastic materials

Ten thin plastic materials (Velostat, RCAS 1200, Llumalloy, Herculite 80, RCAS 2400, Wrightlon 7000, PVC, Aclar 22A, Mylar, and Polyethylene) were tested for electrostatic properties by four different devices: (1) The static decay meter, (2) the manual triboelectric testing device, (3) the robotic triboelectric testing device, and (4) the resistivity measurement adapter device. The static decay meter measured the electrostatic decay rates in accordance with the Federal Test Method Standard 101B, Method 4046. The manual and the robotic triboelectric devices measured the triboelectric generated peak voltages and the five-second decay voltages in accordance with the criteria for acceptance standards at Kennedy Space Center. The resistivity measurement adapter measured the surface resistivity of each material. An analysis was made to correlate the data among the four testing devices. For the material tested the pass/fail results were compared for the 4046 method and the triboelectric testing devices. For the limited number of materials tested, the relationship between decay rate and surface resistivity was investigated as well as the relationship between triboelectric peak voltage and surface resistivity.

Skinner, S. Ballou↗

Nondestructive testing of electro thermal devices

This paper describes the results of a recent investigation into 'thermal time constant' nondestructive testing of high reliability electrical fuses. The use of established nondestructive test technology for examining the quality and firing characteristics of electro-explosive devices has been successfully applied to the inspection and prediction of the functional performance of electrical fuses. The technique requires application of a low level current pulse to the electrical fuse with an oscilloscope display of the curve as generated by the temperature coefficient of resistance feedback. The heating curve of temperature vs time is composed of one predominant thermal time constant, which is the product of the test unit's thermal capacity and thermal resistance. It has been found that the quality of the individual electrical fuse, for instance, the relative condition of the critical internal weld or solder joint, can be examined nondestructively.

Earnest, J. E., Jr.↗

Burst-Disk Device Simulates Effect Of Pyrotechnic Device

Expendable disks substituted for costly pyrotechnic devices for testing actuators. Burst-disk device produces rush of pressurized gas similar to pyrotechnic device. Designed to reduce cost of testing pyrotechnically driven emergency actuators (parachute-deploying mechanisms in original application).

Rogers, James P.↗

Microsemi RTG4 Rev C Field Programmable Gate Array Single Event Effects (SEE) Heavy-Ion Test Report

The goal of this study was to perform an independent investigation of single event destructive and transient susceptibility of the Microsemi RTG4 device. The devices under test were the Microsemi RTG4 field programmable gate array (FPGA) Rev C. The devices under test will be referenced as the DUT or RTG4 Rev C throughout this document. The DUT was configured to have various test structures that are geared to measure specific potential susceptibilities of the device. DesignDevice susceptibility was determined by monitoring the DUT for Single Event Transient (SET) and Single Event Upset (SEU) induced faults by exposing the DUT to a heavy ion beam. Potential Single Event Latch-up (SEL) was checked throughout heavy-ion testing by monitoring device current.

Field Programmable Gate Array (FPGA)↗

Canceling Electromagnetic Interference During Tests

Old technique solves modern problem. Simple amplitude-and-phase-cancellation technique removes strong electromagnetic interference from received test signal, enabling recovery of relatively weak signal from device under test. Useful in outdoor tests of devices for electromagnetic compatibility.

Robinson, Paul A., Jr.↗

gridPULSE: Catalog of National Laboratory Testing Resources for Grid Devices

This catalog was created through the Grid Modernization Laboratory Consortium's (GMLC) Testing Network project. The GMLC is a strategic partnership between the Department of Energy (DOE) and its National Laboratories to bring together leading experts, technologies, and resources to collaborate on the goal of modernizing the nation's electric grid. The benefits of the GMLC include more efficient use of resources; shared networks; improving learning and preservation of knowledge; enhanced lab coordination and collaboration; and regional perspective and relationships with local stakeholders and industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

JPL pyro shock test approaches and results

This paper presents the overall approach at JPL in performing spacecraft pyrotechnic shock qualification testing. Initially, the assembly shock requirements are developed early in the program based on previous spacecraft test experience and data. Pyrotechnic device development testing firings and spacecraft Development Test Model (DTM) pyro firings are then conducted to verify the adequacy of the assembly shock requirements and to determine the subsystem test firing and the subsequent system level test firing requirements. The electro-dynamic shaker, through shock synthesis techniques, is utilized to qualify the shock sensitive flight equipment with margins applied. Actual pyrotechnic device firings on spacecraft equipment or science instruments are performed when the influence of the pyros is localized and can be ignored at the system level. Full spacecraft system level shock tests, which include multiple firings of certain critical pyro devices, are conducted to verify the spacecraft design structural integrity and functions as well as to qualify hardware items which have not been previously qualified. These tests also provide a source of data from which assembly level requirements can be evaluated and compared. For example, during the Galileo program, the results demonstrated that good agreement between predicted and measured shock environments and adequate qualification of the flight spacecraft was achieved.

Chang, Kurng Y.↗

Calibrating Droplet Generator for Pressurized Testing Vessel

Device helps to aline laser for droplet-sizing interferometer. Monodispersing Droplet Generator creates uniformly sized droplets. Laser source and receiver of interferometer alined and focused on droplets. MDG mounted in high-pressure flange on tank. Line extensions pass through flange to outside. Flange allows MDG to operate at high injector back pressures used for tests.

Defever, G. J.↗

Hazard-Free Pyrotechnic Simulator

Simulator evaluates performance of firing circuits for electroexplosive devices (EED's) safely and inexpensively. Tests circuits realistically when pyrotechnic squibs not connected and eliminates risks of explosions. Used to test such devices as batteries where test conditions might otherwise degrade them.