Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Structure-property relationships in NO x sensor materials composed of arrays of vanadium oxide nanoclusters

Here, the mixed-valent vanadium oxide based three-dimensional framework structure species [Cd 3 (H 2 O) 12 V 16 IV V 2 V O 36 (OH) 6 (AO 4 )]∙24H 2 O, (A=V,S) (Cd 3 (VO) o ) represents a rare example of an interesting sensor material which exhibits NO x {NO+NO 2 } semiconducting gas sensor properties under ambient conditions. The electrical resistance of the sensor material Cd 3 (VO) o decreases in air. Combined characterization studies revealed that the building block, {V 18 O 42 (AO 4 )} cluster, of 3-D framework undergoes oxidation and remains intact for at least 2 months. The decrease in resistance is attributable to the reactivity of molecular oxygen towards vanadium which results in an increase in the oxidation state as well as the coordination number of vanadium center and decrease in band gap of Cd 3 (VO) o . Based on these results we propose that the changes in semiconducting properties of Cd 3 (VO) o under ambient conditions are due to the greater overlap between the O 2p and V 3d orbitals occurring during the oxidation.

36 MATERIALS SCIENCE↗

The Surface Interface Characteristics of Vertically Aligned Carbon Nanotube and Graphitic Carbon Fiber Arrays Grown by Thermal and Plasma Enhanced Chemical Vapor Deposition

The development of nano-arrays for sensors and devices requires the growth of arrays with the proper characteristics. One such application is the growth of vertically aligned carbon nanotubes (CNTs) and graphitic carbon fibers (GCFs) for the chemical attachment of probe molecules. The effectiveness of such an array is dependent not only upon the effectiveness of the probe and the interface between that probe and the array, but also the array and the underlaying substrate. If that array is a growth of vertically aligned CNTs or GCFs then the attachment of that array to the surface is of the utmost importance. This attachment provides the mechanical stability and durability of the array, as well as, the electrical properties of that array. If the detection is to be acquired through an electrical measurement, then the appropriate resistance between the array and the surface need to be fabricated into the device. I will present data on CNTs and GCFs grown from both thermal and plasma enhanced chemical vapor deposition. The focus will be on the characteristics of the metal film from which the CNTs and GCFs are grown and the changes that occur due to changes within the growth process.

Delzeit, Lance↗

The POLARBEAR-2 and Simons Array Focal Plane Fabrication Status

We present on the status of POLARBEAR-2 A (PB2-A) focal plane fabrication. The PB2-A is the first of three telescopes in the Simons Array, which is an array of three cosmic microwave background polarization-sensitive telescopes located at the POLARBEAR site in Northern Chile. As the successor to the PB experiment, each telescope and receiver combination is named as PB2-A, PB2-B, and PB2-C. PB2-A and -B will have nearly identical receivers operating at 90 and 150 GHz while PB2-C will house a receiver operating at 220 and 270 GHz. Each receiver contains a focal plane consisting of seven close-hex packed lenslet-coupled sinuous antenna transition edge sensor bolometer arrays. Each array contains 271 dichroic optical pixels, each of which has four TES bolometers for a total of 7588 detectors per receiver. We have produced a set of two types of candidate arrays for PB2-A. The first we call Version 11 (V11) uses a silicon oxide (SiOx) for the transmission lines and crossover process for orthogonal polarizations. The second we call Version 13 (V13) uses silicon nitride (SiNx) for the transmission lines and cross-under process for orthogonal polarizations. We have produced enough of each type of array to fully populate the focal plane of the PB2-A receiver. The average wirebond yield for V11 and V13 arrays is 93.2% and 95.6%, respectively. The V11 arrays had a superconducting transition temperature (T-c) of 452 +/- 15 mK, a normal resistance (R-n) of 1.25 +/- 0.20 Omega, and saturation powers of 5.2 +/- 1.0 pW and 13 +/- 1.2 pW for the 90 and 150 GHz bands, respectively. The V13 arrays had a superconducting transition temperature (T-c) of 456 +/- 6 mK, a normal resistance (R-n) of 1.1 +/- 0.2 Omega, and saturation powers of 10.8 +/- 1.8 pW and 22.9 +/- 2.6 pW for the 90 and 150 GHz bands, respectively. Production and characterization of arrays for PB2-B are ongoing and are expected to be completed by the summer of 2018. We have fabricated the first three candidate arrays for PB2-C but do not have any characterization results to present at this time.

CMB↗

Optimizing infrasound observations for sample return capsule re-entry: Insights from OSIRIS-REx and Hayabusa2

The atmospheric entry of meteoroids presents a rare and unpredictable phenomenon, posing challenges for systematic observation and detailed characterization. Such events are nonetheless critical for advancing understanding of acoustic wave propagation, atmospheric structure, and entry dynamics. In contrast, sample return capsules (SRCs) from space missions follow well constrained re-entry trajectories, enabling planned observations of shock wave generation and propagation under controlled conditions. This study compares two SRC atmospheric entries, Hayabusa2 in 2020 and OSIRIS-REx in 2023, to assess how different infrasound array configurations influence shock wave detection and trajectory validation. Hayabusa2’s re-entry was monitored using a distributed network of 28 portable infrasound sensors across seven arrays in Woomera, Australia, permitting three-dimensional reconstruction of the trajectory and analysis of wave characteristics. For OSIRIS-REx, a compact four-sensor array deployed near Eureka Airport provided trajectory confirmation through arrival-time differences and back-azimuth estimates. Spectral and waveform analyses revealed differences in signal properties associated with variations in entry angle and velocity. The results illustrate both the strengths and the limitations of the deployed array configurations. The dense and distributed arrays during Hayabusa2’s re-entry enabled detailed trajectory reconstruction, whereas the compact array at Eureka primarily provided confirmation of signal coherence and back-azimuth consistency. These case studies highlight that even relatively small arrays, if located close to the predicted ground track, can still capture useful information on arrival direction and timing. Such insights provide practical guidance for planning future observational campaigns of SRC returns and other controlled atmospheric entries, and may also inform approaches to opportunistic observations of meteoroid events and other atmospheric acoustic phenomena.

celestial mechanics: orbit determination↗

Response of the Land-Atmosphere System Over North-Central Oklahoma During the 2017 Eclipse

On 21 August 2017, a solar eclipse occurred over the continental United States resulting in a rapid reduction and subsequent increase of solar radiation over a large region of the country. The eclipse’s effect on the land-atmosphere system is documented in unprecedented detail using a unique array of sensors deployed at three sites in north-central Oklahoma. The observations showed that turbulent fluxes of heat and momentum at the surface responded quickly to the change in solar radiation. The decrease in the sensible heat flux resulted in a decrease in the air temperature below 200 m, and a large decrease in turbulent motions throughout the boundary layer. Furthermore, the turbulent mixing in the boundary layer lagged behind the change in the surface fluxes, and this lag depended on the height above the surface. The turbulent motions increased and the convective boundary layer was reestablished as the sensible heat flux recovered.

Turner, D. D.↗

Evolving Deep Networks Using HPC

While a large number of deep learning networks have been studiedand published that produce outstanding results on natural imagedatasets, these datasets only make up a fraction of those to whichdeep learning can be applied. These datasets include text data, audiodata, and arrays of sensors that have very different characteristicsthan natural images. As these “best” networks for natural imageshave been largely discovered through experimentation and cannotbe proven optimal on some theoretical basis, there is no reasonto believe that they are the optimal network for these drasticallydifferent datasets. Hyperparameter search is thus often a very im-portant process when applying deep learning to a new problem. Inthis work we present an evolutionary approach to searching thepossible space of network hyperparameters and construction thatcan scale to 18, 000 nodes. This approach is applied to datasets ofvarying types and characteristics where we demonstrate the abilityto rapidly find best hyperparameters in order to enable practitionersto quickly iterate between idea and result.

Young, Steven↗

Development of Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Scattering and Energy Dispersive Diffraction Imaging

In this paper we present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electroplating, and proofof-principle fabrication of long strips of SiNx membranes. We demonstrate minimal unwanted effect of strip geometry on X-ray pulse response and showlinear relationship of 1/pulse height and pulse decay times with absorber length. For the absorber lengths studied, our preliminary measurements show energy resolutions of 40-180eV near 17 keV. Furthermore, we show that the heat flow to the cold bath is nearly independent of the absorber area and depends on the SiNx membrane geometry.

47 OTHER INSTRUMENTATION↗

Semiselective Optoelectronic Sensors for Monitoring Microbes

Sensor systems are under development for use in real-time detection and quantitation of microbes in water without need for sampling. These systems include arrays of optical sensors; miniature, portable electronic data-acquisition circuits; and optoelectronic interfaces between the sensor arrays and data-acquisition circuits. These systems are intended for original use in long-term, inline monitoring of waterborne micro-organisms in water-reclamation systems aboard future spacecraft. They could also be adapted to similar terrestrial uses with respect to municipal water supplies, stored drinking water, and swimming water; for detecting low-level biological contamination in biotechnological, semiconductor, and pharmaceutical process streams; and in verifying the safety of foods and beverages. In addition, they could be adapted to monitoring of airborne microbes and of surfaces (e.g., to detect and/or quantitate biofilms). The designs of the sensors in these systems are based partly on those of sensors developed previously for monitoring airborne biological materials. The designs exploit molecular- recognition and fluorescence-spectroscopy techniques, such that in the presence of micro-organisms of interest, fluorescence signals change and the changes can be measured. These systems are characterized as semiselective because they respond to classes of micro-organisms and can be used to discriminate among the classes. This semiselectivity is a major aspect of the design: It is important to distinguish between (1) the principle of detection and quantitation of classes of micro-organisms by use of these sensors and (2) the principle of detection and quantitation of individual microbiological species by means of prior immuno-diagnostic and/or molecular-biology techniques. Detection of classes (in contradistinction to species) is particularly valuable when the exact nature of a contaminant is unknown.

Tabacco, Mary Beth↗

Biochemical Sensors Using Carbon Nanotube Arrays

Method and system for detecting presence of biomolecules in a selected subset, or in each of several selected subsets, in a fluid. Each of an array of two or more carbon nanotubes ("CNTs") is connected at a first CNT end to one or more electronics devices, each of which senses a selected electrochemical signal that is generated when a target biomolecule in the selected subset becomes attached to a functionalized second end of the CNT, which is covalently bonded with a probe molecule. This approach indicates when target biomolecules in the selected subset are present and indicates presence or absence of target biomolecules in two or more selected subsets. Alternatively, presence of absence of an analyte can be detected.

Li, Jun↗

Parallel Quantum-Enhanced Sensing

Quantum metrology takes advantage of quantum correlations to enhance the sensitivity of sensors and measurement techniques beyond their fundamental classical limit, given by the shot-noise limit. The use of both temporal and spatial correlations present in quantum states of light can extend quantum-enhanced sensing to a parallel configuration that can simultaneously probe an array of sensors or independently measure multiple parameters. To this end, we use multispatial-mode bright twin beams of light, which are characterized by independent quantum-correlated spatial subregions in addition to quantum temporal correlations, to probe a four-sensor quadrant plasmonic array. We show that it is possible to independently and simultaneously measure local changes in refractive index for all four sensors with a quantum enhancement in sensitivity in the range of 22% to 24% over the corresponding classical configuration. Finally, these results provide a first step toward highly parallel spatially resolved quantum-enhanced sensing techniques and pave the way toward more complex quantum sensing and quantum imaging platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Energy Laser Diagnostic Sensors

Recent advancements in high energy laser (HEL) sources have outpaced diagnostic tools capable of accurately quantifying system performance. Diagnostic tools are needed that allow system developers to measure the parameters that define HEL effectiveness. The two critical parameters for quantifying HEL effectiveness are the irradiance on target and resultant rise in target temperature. Off-board sensing has its limitations, including unpredictable changes in the reflectivity of the target, smoke and outgassing, and atmospheric distortion. On-board sensors overcome the limitations of off-board techniques but must survive high irradiance levels and extreme temperatures.We have developed sensors for on-target diagnostics of high energy laser beams and for the measurement of the thermal response of the target. The conformal sensors consist of an array of quantum dot photodetectors and resistive temperature detectors. The sensor arrays are lithographically fabricated on flexible substrates and can be attached to a variety of laser targets. We have developed a nanoparticle adhesive process that provides good thermal contact with the target and that ensures the sensor remains attached to the target for as long as the target survives. We have calibrated the temperature and irradiance sensors and demonstrated them in a HEL environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Planishing apparatus and method

Planishing or stress relief in a welded joint (34) is accomplished with a hammer (12) and a backing bar (26). The hammer is applied on a first side (1) to a first surface (31) of the structure (30). To indicate the proper position of the backing bar, a first magnet (20; 320) is associated with the hammer, and a magnetic sensor arrangement (24; 224; 300) is located on the other side (2) of the structure. In one embodiment, the sensor arrangement is a second magnet (24) which is held in place by the magnetic field (40) of the first magnet. In a second embodiment, the sensor includes a line array (262) of individual sensors, each associated with an indicator of a line array (264) of indicators. In a third embodiment, the sensor includes a line array (300) of two magnetic sensors, which are coupled to a differential indicator (324).

Venable, Richard Allen↗

Development of a He{sup 3}−He{sup 4} sub Kelvin active magnetic regenerative refrigerator (AMRR) with no moving parts

Current state of the art particle and photon detectors such as Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) use large arrays of sensors or detectors for space science missions. As the size of these space science detectors increases, future astrophysics missions will require sub-Kelvin cooling over larger areas. This leads to not only increased cooling power requirements, but also a requirement for distributed sub-Kelvin cooling. We propose an active Magnetic Regenerative Refrigerator (AMRR) that uses a Superfluid Magnetic Pump (SMP) to circulate liquid He{sup 3}−He{sup 4} through a magnetic regenerator to provide the necessary cooling at sub-Kelvin temperatures. Such system will be capable of distributing the cooling load to a relatively large array of objects. One advantage of using a fluid for heat transfer in such systems is to isolate components such as the superconducting magnets from detectors that are sensitive to magnetic fields. Another advantage of the proposed tandem AMRR is that it does not need Gas Gap Heat Switches (GGHS) to transfer heat during various stages of the magnetic cooling. Our proposed system consists of four superconducting magnets, one superleak, and three heat exchangers. It will operate continuously with no moving parts and it will be capable of providing the necessary cooling at sub-Kelvin temperatures for future space science applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Maximum power transfer from a solar-cell array by sensing array temperature

A technique is described in which a spacecraft solar-cell array is caused to operate at or near maximum power output over a wide range of environmental conditions. The output of an array temperature sensor is used to vary the duty cycle of a pulse-width-modulated impedance regulator so that the array operates at the voltage of maximum power. A resistance-type temperature sensor was found to be applicable for most spacecraft missions. However, a solar cell used as a temperature sensor has the advantage of negligible transient errors on lightweight arrays for orbiting spacecraft.

Sussman, M.↗

System and method for cognitive processing for data fusion

A system and method for cognitive processing of sensor data. A processor array receiving analog sensor data and having programmable interconnects, multiplication weights, and filters provides for adaptive learning in real-time. A static random access memory contains the programmable data for the processor array and the stored data is modified to provide for adaptive learning.

Duong, Tuan A.↗

Monitoring of corrosion effects in pipes with multi-mode acoustic signals

Current commercial long-range guided wave inspection and monitoring technologies for pipes usually require establishment of certain specific acoustic modes for wave propagation and use a large number of sensors in a certain geometric arrangement (for example, uniformly-spaced arrays of sensors on a collar, placed around a pipe). This paper, in contrast, presents a long-range corrosion detection method in pipes based on multi-mode guided acoustic waves, generated and received using simple, single-element sensors. In this technique, available guided wave modes in any interrogated zone of the structure are automatically down-selected by the medium, and changes in energy distribution over the selected modes are analyzed through signal processing to monitor material loss or addition. Here, to investigate the feasibility of the proposed method, we have performed both experimental and numerical simulation studies on 50.8-mm (2-in)-diameter schedule-40 carbon steel pipes. In these studies, a linear chirp signal is injected in compression mode, perpendicular to the surface of the pipe, generating multi-mode, multi-directional guided waves that travel within the pipe wall. Corrosion effects in the pipes are simulated numerically and experimentally. To reduce errors in the measurement technique due to changes in the local or global temperature of the measured media, a universal temperature compensation algorithm is introduced. The experimental results show good agreement with simulation results, indicating that the proposed multi-mode wave generation and detection in a pipe could be used for long-range detection and monitoring of corrosion effects, such as pipe wall losses or solid material deposits.

36 MATERIALS SCIENCE↗