Search NASA⌕ Search

SEARCH · Search NASA

Results for “software validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

pnnl-predictive-phenomics/csc031-gem

Genome-Scale Metabolic Model of CarbStor Community member Microbacterium (csc031) Continuous Validation with Memote These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity

McNaughton, Andrew [@PNNL]↗

pnnl-predictive-phenomics/csc009-gem

Genome-Scale Metabolic Model of CarbStore Community member Curtobacterium (csc009) Continuous Validation with Memote These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity

Lin, Tesia↗

pnnl-predictive-phenomics/csc040-gem

Genome-Scale Metabolic Model Continuous Validation with Memote for CarbStor Community Member Rhodococcus These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity.

McNaughton, Andrew [@PNNL]↗

pnnl-predictive-phenomics/csc043-gem

Genome-Scale Metabolic Model Continuous Validation with Memote for CarbStor Community Member Paenibacillus These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity.

Zucker, Jeremy [Pacific Northwest National Laborat↗

Data and Tools for Energy Planning and Analysis

The National Renewable Energy Laboratory (NREL) creates widely used data and tools to facilitate energy system planning and analysis. These software tools have been developed for complex research problems and perfected over real-world applications and laboratory validations. Some tools are award winners, others are open-source data explorers, and all are rigorously designed to empower decision-makers with accurate and accessible information. This software selection shows how NREL resources can help stakeholders achieve a clean, just, and resilient energy transformation.

data↗

Comparison of 3-dimensional dose reconstruction system between fluence-based system and dose measurement-guided system

COMPASS system (IBA Dosimetry, Schwarzenbruck, Germany) and ArcCHECK with 3DVH software (Sun Nuclear Corp., Melbourne, FL) are commercial quasi-3-dimensional (3D) dosimetry arrays. Cross-validation to compare them under the same conditions, such as a treatment plan, allows for clear evaluation of such measurement devices. In this study, we evaluated the accuracy of reconstructed dose distributions from the COMPASS system and ArcCHECK with 3DVH software using Monte Carlo simulation (MC) for multi-leaf collimator (MLC) test patterns and clinical VMAT plans. In a phantom study, ArcCHECK 3DVH showed clear differences from COMPASS, measurement and MC due to the detector resolution and the dose reconstruction method. Especially, ArcCHECK 3DVH showed 7% difference from MC for the heterogeneous phantom. ArcCHECK 3DVH only corrects the 3D dose distribution of treatment planning system (TPS) using ArcCHECK measurement, and therefore the accuracy of ArcCHECK 3DVH depends on TPS. In contrast, COMPASS showed good agreement with MC for all cases. However, the COMPASS system requires many complicated installation procedures such as beam modeling, and appropriate commissioning is needed. In terms of clinical cases, there were no large differences for each QA device. The accuracy of the compass and ArcCHECK 3DVH systems for phantoms and clinical cases was compared. Both systems have advantages and disadvantages for clinical use, and consideration of the operating environment is important. The QA system selection is depending on the purpose and workflow in each hospital.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear Canister Corrosion Detection

The software titled "nccd" is used for running residual neural networks (ResNets) on images of nuclear canisters. The software provides only the code for the implementation (based on the fastai library), but it does not share the image data. The compute code allows the use of residual nets (and more generally of other deep learning models) for classifying images from nuclear canisters as corroded. or intact. An image is considered to be corroded if it contains pitting or stress corrosion cracks. The code trains ResNets on image tiles extracted from original images from nuclear canisters, and then implements a classification rule, which can be applied to a validation set to decide if each original image is corroded or intact. The software automates the process of using images taken from nuclear canisters to detect corrosion. It provides also scope for future research directions on the basis of the existing research and code.

Papamarkou, Theodore↗

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the mirror instability in the presence of electron temperature anisotropy

Computation of the mirror instability growth rate in an ion-electron bi-Maxwellian plasma is revisited, starting from the low-frequency kinetic theory. The role of the electron finite Larmor radius (FLR) effects on the instability quenching is shown to possibly be dominant, even near threshold where the smallest unstable scales significantly exceed the electron gyroscale. Validation of the results by comparison with predictions of the fully kinetic whamp software is also presented. The influence of the electron temperatures on the ion FLR effects very near threshold, where the electron kinetic effects are negligible, is also pointed out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The first measurements of soft x-ray flux from ignition scale Hohlraums at the National Ignition Facility using DANTE (invited)

The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an {approx}20 times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30{+-}10% more flux than predicted by the preshot radiation hydrodynamic simulations. To validate these results, careful verification of all component calibrations, cable deconvolution, and software analysis routines has been conducted. In addition, a half Hohlraum experiment was conducted using a single 2 ns long axial quad with an irradiance of {approx}2x10{sup 15} W/cm{sup 2} for comparison with NIF Early Light experiments completed in 2004. We have also completed a conversion efficiency test using a 128-beam nearly uniformly illuminated gold sphere with intensities kept low (at 1x10{sup 14} W/cm{sup 2} over 5 ns) to avoid sensitivity to modeling uncertainties for nonlocal heat conduction and nonlinear absorption mechanisms, to compare with similar intensity, 3 ns OMEGA sphere results. The 2004 and 2009 NIF half-Hohlraums agreed to 10% in flux, but more importantly, the 2006 OMEGA Au Sphere, the 2009 NIF Au sphere, and the calculated Au conversion efficiency agree to {+-}5% in flux, which is estimated to be the absolute calibration accuracy of the DANTEs. Hence we conclude that the 30{+-}10% higher than expected radiation fluxes from the 96 and 192 beam vacuum Hohlraums are attributable to differences in physics of the larger Hohlraums.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and tuning of the CMS full simulation

The CMS simulation, based on the Geant4 toolkit, has been operational within the new CMS software framework for more than four years. The description of the detector, including the forward regions, has been completed. A detailed investigation of detector positioning and material budget is underway using collision data. Detailed modelling of detector noise has been performed and validated with the collision data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-209-06: Improving X-Ray Imaging with Computer Vision and Augmented Reality

Purpose: To determine the feasibility of using a computer vision algorithm and augmented reality interface to reduce repeat rates and improve consistency of image quality and patient exposure in general radiography. Methods: A prototype device, designed for use with commercially available hardware (Microsoft Kinect 2.0) capable of depth sensing and high resolution/frame rate video, was mounted to the x-ray tube housing as part of a Philips DigitalDiagnost digital radiography room. Depth data and video was streamed to a Windows 10 PC. Proprietary software created an augmented reality interface where overlays displayed selectable information projected over real-time video of the patient. The information displayed prior to and during x-ray acquisition included: recognition and position of ordered body part, position of image receptor, thickness of anatomy, location of AEC cells, collimated x-ray field, degree of patient motion and suggested x-ray technique. Pre-clinical data was collected in a volunteer study to validate patient thickness measurements and x-ray images were not acquired. Results: Proprietary software correctly identified ordered body part, measured patient motion, and calculated thickness of anatomy. Pre-clinical data demonstrated accuracy and precision of body part thickness measurement when compared with other methods (e.g. laser measurement tool). Thickness measurements provided the basis for developing a database of thickness-based technique charts that can be automatically displayed to the technologist. Conclusion: The utilization of computer vision and commercial hardware to create an augmented reality view of the patient and imaging equipment has the potential to drastically improve the quality and safety of x-ray imaging by reducing repeats and optimizing technique based on patient thickness. Society of Pediatric Radiology Pilot Grant; Washington University Bear Cub Fund.

60 APPLIED LIFE SCIENCES↗

Implementing an X-ray validation pipeline for the Protein Data Bank

The implementation of a validation pipeline, based on community recommendations, for future depositions of X-ray crystal structures in the Protein Data Bank is described. There is an increasing realisation that the quality of the biomacromolecular structures deposited in the Protein Data Bank (PDB) archive needs to be assessed critically using established and powerful validation methods. The Worldwide Protein Data Bank (wwPDB) organization has convened several Validation Task Forces (VTFs) to advise on the methods and standards that should be used to validate all of the entries already in the PDB as well as all structures that will be deposited in the future. The recommendations of the X-ray VTF are currently being implemented in a software pipeline. Here, ongoing work on this pipeline is briefly described as well as ways in which validation-related information could be presented to users of structural data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic fracture of functionally graded magnetoelectroelastic composite materials

The stress, magnetic and electric field analysis of multifunctional composites, weakened by impermeable cracks, is of fundamental importance for their structural integrity and reliable service performance. The aim is to study dynamic behavior of a plane of functionally graded magnetoelectroelastic composite with more than one crack. The coupled material properties vary exponentially in an arbitrary direction. The plane is subjected to anti-plane mechanical and in-plane electric and magnetic load. The boundary value problem described by the partial differential equations with variable coefficients is reduced to a non-hypersingular traction boundary integral equation based on the appropriate functional transform and frequency-dependent fundamental solution derived in a closed form by Radon transform. Software code based on the boundary integral equation method (BIEM) is developed, validated and inserted in numerical simulations. The obtained results show the sensitivity of the dynamic stress, magnetic and electric field concentration in the cracked plane to the type and characteristics of the dynamic load, to the location and cracks disposition, to the wave-crack-crack interactions and to the magnitude and direction of the material gradient.

36 MATERIALS SCIENCE↗

Some issues in the simulation of two-phase flows: The relative velocity

In this paper we compare numerical approximations for solving the Riemann problem for a hyperbolic two-phase flow model in two-dimensional space. The model is based on mixture parameters of state where the relative velocity between the two-phase systems is taken into account. This relative velocity appears as a main discontinuous flow variable through the complete wave structure and cannot be recovered correctly by some numerical techniques when simulating the associated Riemann problem. Simulations are validated by comparing the results of the numerical calculation qualitatively with OpenFOAM software. Simulations also indicate that OpenFOAM is unable to resolve the relative velocity associated with the Riemann problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Current–voltage characteristics of Schottky diodes at high current densities under the injection of minority carriers

An analytical expression is derived for the current–voltage characteristic of a Schottky diode at a high injection level of minority carriers. It is shown that, even at very high current densities, the higher the base doping level, the larger the voltage drop across the diode. The physical mechanism responsible for this “paradoxical” result is analyzed. The validity of the analytical result is confirmed by a numerical calculation with software that takes into account the whole set of nonlinear effects caused by a high injection level in the base layer and by heavy doping of the emitter region.

36 MATERIALS SCIENCE↗

Implementing the Data Center Energy Productivity Metric

As data centers proliferate in both size and number, their energy efficiency is becoming increasingly important. We discuss the properties of a number of the proposed metrics of energy efficiency and productivity. In particular, we focus on the Data Center Energy Productivity (DCeP) metric, which is the ratio of useful work produced by the data center to the energy consumed performing that work. We describe our approach for using DCeP as the principal outcome of a designed experiment using a highly instrumented, high performance computing data center. We found that DCeP was successful in clearly distinguishing between different operational states in the data center, thereby validating its utility as a metric for identifying configurations of hardware and software that would improve (or even maximize) energy productivity. We also discuss some of the challenges and benefits associated with implementing the DCeP metric, and we examine the efficacy of the metric in making comparisons within a data center and among data centers.

Sego, Landon H↗