Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Active Noise Control of Low Speed Fan Rotor-Stator Modes

This report describes the Active Noise Cancellation System designed by General Electric and tested in the NASA Lewis Research Center's 48 inch Active Noise Control Fan. The goal of this study was to assess the feasibility of using wall mounted secondary acoustic sources and sensors within the duct of a high bypass turbofan aircraft engine for active noise cancellation of fan tones. The control system is based on a modal control approach. A known acoustic mode propagating in the fan duct is cancelled using an array of flush-mounted compact sound sources. Controller inputs are signals from a shaft encoder and a microphone array which senses the residual acoustic mode in the duct. The canceling modal signal is generated by a modal controller. The key results are that the (6,0) mode was completely eliminated at 920 Hz and substantially reduced elsewhere. The total tone power was reduced 9.4 dB. Farfield 2BPF SPL reductions of 13 dB were obtained. The (4,0) and (4,1) modes were reduced simultaneously yielding a 15 dB modal PWL decrease. Global attenuation of PWL was obtained using an actuator and sensor system totally contained within the duct.

Sutliff, Daniel L.↗

Air transparent soundproof window

A soundproof window or wall which is transparent to airflow is presented. The design is based on two wave theories: the theory of diffraction and the theory of acoustic metamaterials. It consists of a three-dimensional array of strong diffraction-type resonators with many holes centered on each individual resonator. The negative effective bulk modulus of the resonators produces evanescent wave, and at the same time the air holes with subwavelength diameter existed on the surfaces of the window for macroscopic air ventilation. The acoustic performance levels of two soundproof windows with air holes of 20mm and 50mm diameters were measured. The sound level was reduced by about 30 - 35dB in the frequency range of 400 - 5,000Hz with the 20mm window, and by about 20 - 35dB in the frequency range of 700 - 2,200Hz with the 50mm window. Multi stop-band was created by the multi-layers of the window. The attenuation length or the thickness of the window was limited by background noise. The effectiveness of the soundproof window with airflow was demonstrated by a real installation.

36 MATERIALS SCIENCE↗

Propagation of sound waves in tubes of noncircular cross section

Plane-acoustic-wave propagation in small tubes with a cross section in the shape of a flattened oval is described. Theoretical descriptions of a plane wave propagating in a tube with circular cross section and between a pair of infinite parallel plates, including viscous and thermal damping, are expressed in similar form. For a wide range of useful duct sizes, the propagation constant (whose real and imaginary parts are the amplitude attenuation rate and the wave number, respectively) is very nearly the same function of frequency for both cases if the radius of the circular tube is the same as the distance between the parallel plates. This suggests that either a circular-cross-section model or a flat-plate model can be used to calculate wave propagation in flat-oval tubing, or any other shape tubing, if its size is expressed in terms of an equivalent radius, given by g = 2 x (cross-sectional area)/(length of perimeter). Measurements of the frequency response of two sections of flat-oval tubing agree with calculations based on this idea. Flat-plate formulas are derived, the use of transmission-line matrices for calculations of plane waves in compound systems of ducts is described, and examples of computer programs written to carry out the calculations are shown.

Richards, W. B.↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent for Reducing Bat Fatalities at Wind Turbines

Large numbers of bats are killed by wind turbines worldwide and minimizing fatalities is critically important to bat conservation and acceptance of wind energy development. We implemented a 2-year study testing the effectiveness of an ultrasonic acoustic deterrent for reducing bat fatalities at a wind energy facility in Pennsylvania. We randomly selected control and treatment turbines that were searched daily in summer and fall 2009 and 2010. Estimates of fatality, corrected for field biases, were compared between treatment and control turbines. In 2009, we estimated 21–51% fewer bats were killed per treatment turbine than per control turbine. In 2010, we determined an approximate 9% inherent difference between treatment and control turbines and when factored into our analysis, variation increased and between 2% more and 64% fewer bats were killed per treatment turbine relative to control turbines. We estimated twice as many hoary bats were killed per control turbine than treatment turbine, and nearly twice as many silver-haired bats in 2009. In 2010, although we estimated nearly twice as many hoary bats and nearly 4 times as many silver-haired bats killed per control turbine than at treatment turbines during the treatment period, these only represented an approximate 20% increase in fatality relative to the pre-treatment period for these species when accounting for inherent differences between turbine sets. Our findings suggest broadband ultrasound broadcasts may reduce bat fatalities by discouraging bats from approaching sound sources. However, effectiveness of ultrasonic deterrents is limited by distance and area ultrasound can be broadcast, in part due to rapid attenuation in humid conditions. We caution that an operational deterrent device is not yet available and further modifications and experimentation are needed. Future efforts must also evaluate cost-effectiveness of deterrents in relation to curtailment strategies to allow a cost-benefit analysis for mitigating bat fatalities.

60 APPLIED LIFE SCIENCES↗

Analytical and experimental investigation of the propagation and attenuation of sound in extended reaction lined ducts

Results are presented of an analytical and experimental study of the attenuation and propagation of harmonically excited sound waves in an extended reaction lined cylindrical duct. The duct geometry considered consisted of an annular outer region of bulk material surrounding an inner cylinder of air. The coupled wave equations governing the motion of the sound in both the inner and annular regions were solved numerically. The numerically predicted attenuation and propagation constants were in excellent agreement with measured values using Kevlar as the liner material for plane-wave mode (0,0) excitation over the frequency from 100 to 7,000 Hz. Although the numerical model was verified using Kevlar, it can be used with any fibrous constructed bulk liner. The results of this study demonstrate that a good start has been made on the numerical modelling of the acoustic performance of extended reaction liners.

Hersh, A. S.↗

A Method for Optimizing Non-Axisymmetric Liners for Multimodal Sound Sources

Central processor unit times and memory requirements for a commonly used solver are compared to that of a state-of-the-art, parallel, sparse solver. The sparse solver is then used in conjunction with three constrained optimization methodologies to assess the relative merits of non-axisymmetric versus axisymmetric liner concepts for improving liner acoustic suppression. This assessment is performed with a multimodal noise source (with equal mode amplitudes and phases) in a finite-length rectangular duct without flow. The sparse solver is found to reduce memory requirements by a factor of five and central processing time by a factor of eleven when compared with the commonly used solver. Results show that the optimum impedance of the uniform liner is dominated by the least attenuated mode, whose attenuation is maximized by the Cremer optimum impedance. An optimized, four-segmented liner with impedance segments in a checkerboard arrangement is found to be inferior to an optimized spanwise segmented liner. This optimized spanwise segmented liner is shown to attenuate substantially more sound than the optimized uniform liner and tends to be more effective at the higher frequencies. The most important result of this study is the discovery that when optimized, a spanwise segmented liner with two segments gives attenuations equal to or substantially greater than an optimized axially segmented liner with the same number of segments.

Watson, W. R.↗

Modification of Mach 6 Freestream Flow by Pitot Probe Bow Shock as Measured by Line FLDI and SAFS

Measurements of the flow in front of flat-face Pitot probes in NASA Langley ResearchCenter’s 20-Inch Mach 6 Air Tunnel were made using a 35-point line focused laser differentialinterferometer (FLDI), a two-point FLDI, and a self-aligned focusing schlieren system. Thesesystems were used to make measurements of flow unsteadiness between the bow shock andPitot probe face, while also probing the freestream region just upstream of the bow shock.Shock standoff distances from the non-intrusive measurements match closely with analyticalsolutions using the probe face diameter. Acoustic wave angles and velocities in the freestreamcompare favorably with DNS simulations of a Mach 6 freestream flow, and wave velocities in thepost-shock region slow as they approach the probe face. Peak frequencies in the post-shockregion as measured by FLDI compare favorably to the estimates computed from the shockstandoff distance for most probe diameters. With increasing unit Reynolds number, fluctuationintensities in the post-shock region were attenuated below the intensities of the freestream, witha spectral, spatial, and probe size dependence. Pitot probe power spectral density estimatesare presented from the test campaign, which can be compared with FLDI and SAFS data toevaluate the applicability of the transfer functions derived from computational simulations.

Joshua M Weisberger↗

Analysis of Acoustic Modeling and Sound Propagation in Aircraft Noise Prediction

An analysis has been performed of measured and predicted aircraft noise levels around Denver International Airport. A detailed examination was made of 90 straight-out departures that yielded good measurements on multiple monitors. Predictions were made with INM 5, INM 6 and the simulation model NMSIM. Predictions were consistently lower than measurements, less so for the simulation model than for the integrated models. Lateral directivity ("installation effect") patterns were seen which are consistent with other recent measurements. Atmospheric absorption was determined to be a significant factor in the underprediction. Calculations of atmospheric attenuation were made over a full year of upper air data at seven locations across the United States. It was found that temperature/humidity effects could cause variations of up to +/-4 dB, depending on season, for the sites examined. It was concluded that local temperature and humidity should be accounted for in aircraft noise modeling.

Plotkin, Kenneth J.↗

Earthquake detection in a simulated lunar regolith using distributed acoustic sensing

Current models of inner lunar geology have largely been inferred from the seismic experiments and observations performed during the Apollo missions that comprised a relatively small number of seismic instruments. Refining constraints on fundamental lunar relationships such as crust-mantle and mantle-core boundaries in the future will require seismic arrays spanning larger epicentral distances. A promising technology for installing dense seismic arrays with minimal human effort is distributed acoustic sensing (DAS), an approach that allows a single length of fiber optic cable to act as hundreds or thousands of sensors when coupled with a DAS interrogator. While terrestrial uses of DAS technology for seismic monitoring rely on burying the cable to maximize fidelity of seismic signal transmission to the fiber, digging meters of trench to bury optical fiber on lunar or planetary surfaces is logistically infeasible. To evaluate DAS signal attenuation due to surface deployment of cable in lunar regolith, we completed earthquake detection analyses that evaluated the sensitivity of an optic-fiber DAS system to seismic signals at different burial depths. We deployed a single-mode fiber in a 10-m open-bottom wooden box filled with a lunar regolith simulant (LRS) with fiber buried at different depths within the LRS and recorded signals for four regional and local earthquakes. The results were used to identify and evaluate signal attenuation in surface-deployed fiber compared to buried fiber in the LRS. Burial depth responses to active-source signals were also evaluated similar to previous studies characterizing DAS sensitivity of surface-deployed fiber. Atmospheric noise was minimal as the cable was deployed in an indoor environment; however, where observed, atmospheric and anthropogenic noise was filtered out using the same bandpass filtering used to identify earthquake events. We found that signal attenuation of the surface-deployed fiber compared to buried fiber was relatively high in active-source experiments but was not consistently observed in earthquake signals. That burial depth is not highly correlated to attenuation of the observed earthquake signals indicates that in a noise-limited environment, placing DAS-interrogated fiber directly at the regolith surface may be a promising deployment strategy to consider for sensing remote seismic signals during lunar exploration.

58 GEOSCIENCES↗

Noise reduction as affected by the extent and distribution of acoustic treatment in a turbofan engine inlet

An inlet noise suppressor for a TF-34 engine designed to have three acoustically treated rings was tested with several different ring arrangements. The configurations included: all three rings; two outer rings; single outer ring; single intermediate ring, and finally no rings. It was expected that as rings were removed, the acoustic performance would be degraded considerably. While a degradation occurred, it was not as large as predictions indicated. In fact, the prediction showed good agreement with the data only for the full-ring inlet configuration. The under-predictions which occurred with ring removal were believed a result of ignoring the presence of spinning modes which are known to damp more rapidly in cylindrical ducts than would be predicted by least attenuated mode or plane wave analysis.

Minner, G. L.↗

Anelastic sensitivity kernels with parsimonious storage for adjoint tomography and full waveform inversion

We introduce a technique to compute exact anelastic sensitivity kernels in the time domain using parsimonious disk storage. The method is based on a reordering of the time loop of time-domain forward/adjoint wave propagation solvers combined with the use of a memory buffer. It avoids instabilities that occur when time-reversing dissipative wave propagation simulations. The total number of required time steps is unchanged compared to usual acoustic or elastic approaches. The cost is reduced by a factor of 4/3 compared to the case in which anelasticity is partially accounted for by accommodating the effects of physical dispersion. We validate our technique by performing a test in which we compare the Kα sensitivity kernel to the exact kernel obtained by saving the entire forward calculation. This benchmark confirms that our approach is also exact. We illustrate the importance of including full attenuation in the calculation of sensitivity kernels by showing significant differences with physical-dispersion-only kernels.

Geochemistry & Geophysics↗

Acoustic structure and propagation in highly porous, layered, fibrous materials

The acoustic structure and propagation of sound in highly porous, layered, fine fiber materials is examined. Of particular interest is the utilization of the Kozeny number for determining the static flow resistance and the static structure factor based on flow permeability measurements. In this formulation the Kozeny number is a numerical constant independent of volume porosity at high porosities. The other essential parameters are then evaluated employing techniques developed earlier for open cell foams. The attenuation and progressive phase characteristics in bulk samples are measured and compared with predicted values. The agreements on the whole are very satisfactory.

Lambert, R. F.↗

Acoustic structure and propagation in highly porous, layered, fibrous materials

The acoustic structure and propagation of sound in highly porous, layered, fine fiber materials is examined. Of particular interest is the utilization of the Kozeny number for determining the static flow resistance and the static structure factor based on flow permeability measurements. In this formulation the Kozeny number is a numerical constant independent of volume porosity at high porosities. The other essential parameters are then evaluated employing techniques developed earlier for open cell foams. The attenuation and progressive phase characteristics in bulk samples are measured and compared with predicted values. The agreements on the whole are very satisfactory.

Lambert, R. F.↗

Magneto-acoustic study near the quantum critical point of the frustrated quantum antiferromagnet Cs{sub 2}CuCl{sub 4}

Magneto-acoustic investigations of the frustrated triangular-lattice antiferromagnet Cs{sub 2}CuCl{sub 4} were performed for the longitudinal modes c{sub 11} and c{sub 33} in magnetic fields along the a-axis. The temperature dependence of the sound velocity at zero field shows a mild softening at low temperature and displays a small kink-like anomaly at T{sub N}. Isothermal measurements at T < T{sub N} of the sound attenuation α reveal two closely spaced features of different characters on approaching the material's quantum-critical point (QCP) at B{sub s} ≈ 8.5 T for B || a. The peak at slightly lower fields remains sharp down to the lowest temperature and can be attributed to the ordering temperature T{sub N}(B). The second anomaly, which is rounded and which becomes reduced in size upon cooling, is assigned to the material's spin-liquid properties preceding the long-range antiferromagnetic ordering with decreasing temperature. These two features merge upon cooling suggesting a coincidence at the QCP. The elastic constant at lowest temperatures of our experiment at 32 mK can be well described by a Landau free energy model with a very small magnetoelastic coupling constant G/k{sub B} ≈ 2.8 K. The applicability of this classical model indicates the existence of a small gap in the magnetic excitation spectrum which drives the system away from quantum criticality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ground testing at MSFC

The large-scale field collection of acoustic data and their analysis are described in this review. The entire sound-field program has the purpose of solving complex problems of excessive noise propagation associated with the static test firing of large space-booster powerplants. The site of data collection has been Mississippi Test Facility (MTF), where far-field sound-propagation and correlated meteorological measurements were initiated in 1962. The statistical evaluation of sound-measurement data shows that the polar distribution of sound in the springtime (at MTF) is determined mainly by the temperature field of the atmosphere. Greater deformation of sound-intensity polar distribution occurs in the autumn as a result of the influence of the wind field. The data on sound attenuation as a function of distance from its source revealed attenuation in excess of the expected magnitude. The excess was mainly between 1 and 10 kilometers from the source, with maximum attenuation (17 to 18 decibels) near 6 kilometers. Excess sound attenuation was compared with calculated sound dispersion. For all sound frequencies in all seasons the deviation between reference and empirical attenuation values formed a bell-shaped distribution on a semilogarithmic plot. The physical causes for the sound- attenuation behavior are considered to be atmospheric diffraction and scattering effects. Statistical analysis of sod-intensity extremes indicated amplification of the sound signals by focusing which could be expected along selected azimuths. Empirical amplification values showed the maximum occurring in winter (50 decibels at 22 kilometers). For the analysis of correlation between empirical sound data and local atmospheric sound- propagation conditions, #e concept of analytical classification of sound-velocity profiles has been developed. Examination of over a quarter-million individual sound-velocity profiles indicates that 33 profile types for heights up to 3 kilometers constitute the empirical possibilities of sound-propagation conditions in southeastern United States. Since the focusing qualities of each sound- velocity profile can be determined as a class characteristic, the overall probabilities of focusing occurrence can he obtained. The severity of focusing, as based upon lateral spread of focusing areas, has been determined. The data for MTF indicate focusing is most severe in winter, with the direction toward east being most affected. Sound propagation is a fluctuating phenomenon because atmospheric conditions vary continuously. A measuring system for analyzing the nonstationary sound-propagation phenomena has been established. The analysis of the acoustic fluctuation data is sup- posed to provide "dynamic” perturbation functions of sound, which are to be superimposed on the related characteristic sound-velocity-profile type. The ultimate result of the program will be the establishment of reliable contingency tables showing the relationship between atmospheric parameters and far-field sound intensities. These data will be the basis for more accurate sound-propagation forecasting for static firing tests.

STATIC TESTING↗

Methods for the calculation of axial wave numbers in lined ducts with mean flow

A survey is made of the methods available for the calculation of axial wave numbers in lined ducts. Rectangular and circular ducts with both uniform and non-uniform flow are considered as are ducts with peripherally varying liners. A historical perspective is provided by a discussion of the classical methods for computing attenuation when no mean flow is present. When flow is present these techniques become either impractical or impossible. A number of direct eigenvalue determination schemes which have been used when flow is present are discussed. Methods described are extensions of the classical no-flow technique, perturbation methods based on the no-flow technique, direct integration methods for solution of the eigenvalue equation, an integration-iteration method based on the governing differential equation for acoustic transmission, Galerkin methods, finite difference methods, and finite element methods.

Eversman, W.↗

Full-Scale Turbofan-Engine Turbine-Transfer Function Determination Using Three Internal Sensors

Existing NASA/Honeywell EVNERT full-scale static engine test data is analyzed by using source-separation techniques in order to determine the turbine transfer of the currently sub-dominant combustor noise. The results are used to assess the combustor-noise prediction capability of the Aircraft Noise Prediction Program (ANOPP). Time-series data from three sensors internal to the Honeywell TECH977 research engine is used in the analysis. The true combustor-noise turbine-transfer function is educed by utilizing a new three-signal approach. The resulting narrowband gain factors are compared with the corresponding constant values obtained from two empirical acoustic-turbine-loss formulas. It is found that a simplified Pratt & Whitney formula agrees better with the experimental results for frequencies of practical importance. The 130 deg downstream-direction far-field 1/3-octave sound-pressure levels (SPL) results of Hultgren & Miles are reexamined using a post-correction of their ANOPP predictions for both the total noise signature and the combustion-noise component. It is found that replacing the standard ANOPP turbine-attenuation function for combustion noise with the simplified Pratt & Whitney formula clearly improves the predictions. It is recommended that the GECOR combustion-noise module in ANOPP be updated to allow for a user-selectable switch between the current transmission-loss model and the simplified Pratt & Whitney formula. The NASA Fundamental Aeronautics Program has the principal objective of overcoming today's national challenges in air transportation. The Subsonic Fixed Wing Project's Reduce-Perceived-Noise Technical Challenge aims to develop concepts and technologies to dramatically reduce the perceived aircraft noise outside of airport boundaries. The reduction of aircraft noise is critical to enabling the anticipated large increase in future air traffic.

Hultgren, Lennart S.↗

Coupling of Helmholtz resonators to improve acoustic liners for turbofan engines at low frequency

An analytical and test program was conducted to evaluate means for increasing the effectiveness of low frequency sound absorbing liners for aircraft turbine engines. Three schemes for coupling low frequency absorber elements were considered. These schemes were analytically modeled and their impedance was predicted over a frequency range of 50 to 1,000 Hz. An optimum and two off-optimum designs of the most promising, a parallel coupled scheme, were fabricated and tested in a flow duct facility. Impedance measurements were in good agreement with predicted values and validated the procedure used to transform modeled parameters to hardware designs. Measurements of attenuation for panels of coupled resonators were consistent with predictions based on measured impedance. All coupled resonator panels tested showed an increase in peak attenuation of about 50% and an increase in attenuation bandwidth of one one-third octave band over that measured for an uncoupled panel. These attenuation characteristics equate to about 35% greater reduction in source perceived noise level (PNL), relative to the uncoupled panel, or a reduction in treatment length of about 24% for constant PNL reduction. The increased effectiveness of the coupled resonator concept for attenuation of low frequency broad spectrum noise is demonstrated.

Dean, L. W.↗