Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

In operando studies of CO oxidation on epitaxial SrCoO 2.5+δ thin films

The high abundance and fast kinetics of select transition metal oxide catalysts are attractive features for many chemical and electrochemical device applications. However, the activity of such catalysts can be accompanied by phase instabilities that prevent their widespread usage. Furthermore, complexities associated with variations in phase behavior and oxygen stoichiometry have hindered studies on the true origins of catalytic activity. Here, we explore the interactions between activity, phase stability, and microstructure using in operando synchrotron X-ray techniques and gas chromatography/mass spectroscopy (GCMS) to probe the behavior of model SrCoO 2.5+δ (SCO) catalysts. Pulsed laser deposition was used to prepare SCO thin films on (001) SrTiO 3 , (111) SrTiO 3 , and pseudocubic (001) DyScO 3 substrates. The GCMS catalytic measurements were performed with a custom-built microreactor compatible with a synchrotron X-ray diffractometer at the Advanced Photon Source. The activity for carbon monoxide oxidation was determined as a function of temperature from 500 °C to 800 °C. We show that the SrCoO 2.5+δ films are active for CO oxidation, most likely by direct reaction with lattice oxygen; consequently, the activity was observed to increase as the films become less stable, with the most active film being the one exhibiting the lowest surface and crystal quality. All films decompose at high temperatures, with in operando diffraction indicating the gradual formation of Sr-rich hexagonal and CoO phases. We find that real-time studies of model oxide systems with synchrotron X-rays is a powerful means of gaining insight into the varied processes taking place at catalytic surfaces.

36 MATERIALS SCIENCE↗

An in situ shearing x-ray measurement system for exploring structures and dynamics at the solid–liquid interface

Revealing interfacial structure and dynamics has been one of the essential thematic topics in material science and condensed matter physics. Synchrotron-based x-ray scattering techniques can deliver unique and insightful probing of interfacial structures and dynamics, in particular, in reflection geometries with higher surface and interfacial sensitivity than transmission geometries. We demonstrate the design and implementation of an in situ shearing x-ray measurement system, equipped with both inline parallel-plate and cone-and-plate shearing setups and operated at the advanced photon source at Argonne National Laboratory, to investigate the structures and dynamics of end-tethered polymers at the solid-liquid interface. With a precise lifting motor, a micrometer-scale gap can be produced by aligning two surfaces of a rotating upper shaft and a lower sample substrate. A torsional shear flow forms in the gap and applies tangential shear forces on the sample surface. The technical combination with nanoscale rheology and the utilization of in situ x-ray scattering allow us to gain fundamental insights into the complex dynamics in soft interfaces under shearing. In this work, we demonstrate the technical scope and experimental capability of the in situ shearing x-ray system through the measurements of charged polymers at both flat and curved interfaces upon shearing. Furthermore, through the in situ shearing x-ray scattering experiments integrated with theoretical simulations, we aim to develop a detailed understanding of the short-range molecular structure and mesoscale ionic aggregate morphology, as well as ion transport and dynamics in soft interfaces, thereby providing fundamental insight into a long-standing challenge in ionic polymer brushes with a significant technological impact.

36 MATERIALS SCIENCE↗

Synchrotron characterization of high-Z, current-mode x-ray detectors

Fast x-ray detectors are critical tools in pulsed power and fusion applications, where detector impulse response of a nanosecond or better is often required. Semiconductor detectors can create fast, sensitive devices with extensive operational flexibility. There is typically a trade-off between detector sensitivity and speed, but higher atomic number absorbers can increase hard x-ray absorption without increasing the charge collection time, provided carriers achieve high velocity. This paper presents x-ray pulse characterization conducted at the Advanced Photon Source of x-ray absorption efficiency and temporal impulse response of current-mode semiconductor x-ray detectors composed of Si, GaAs, and CdTe.

47 OTHER INSTRUMENTATION↗

Single-pulse (100 ps) extended x-ray absorption fine structure capability at the Dynamic Compression Sector

Determining real-time changes in the local atomistic order is important for a mechanistic understanding of shock wave induced structural and chemical changes. However, the single event and short duration (nanosecond times) nature of shock experiments pose challenges in obtaining Extended X-ray Absorption Fine Structure (EXAFS) measurements - typically used for monitoring local order changes. Here, we report on a new single pulse (~100 ps duration) transmission geometry EXAFS capability for use in laser shock-compression experiments at the Dynamic Compression Sector (DCS), Advanced Photon Source. We used a flat plate of highly oriented pyrolytic graphite (HOPG) as the spectrometer element to energy disperse x-rays transmitted through the sample. It provided high efficiency with approximately 15% of the x-rays incident on the HOPG reaching an x-ray area detector with high quantum efficiency. This combination resulted in good signal-to-noise ratio (~10 3 ), energy resolution of ~10 eV at 10 keV, EXAFS spectra covering 100s of eV, and good pulse to pulse reproducibility of our single pulse measurements. Ambient EXAFS spectra for Cu and Au are compared to reference spectra, validating our measurement system. Comparison of single pulse EXAFS results for ambient and laser shocked Ge(100) shows large changes to the local structure of the short lived state of shocked Ge. The current DCS EXAFS capability can be used to perform single pulse measurements in laser shocked materials from approximately 9-13 keV. These EXAFS developments will be available to all users of the DCS.

47 OTHER INSTRUMENTATION↗

In situ x-ray and electron scattering studies of oxide molecular beam epitaxial growth

We perform the first in situ synchrotron X-ray ray diffraction (SXRD) / reflection high energy electron diffraction (RHEED) studies on the growth of complex oxide thin films by molecular beam epitaxy. The unique deposition chamber, located at the Advanced Photon Source, allows the preparation of complex oxide samples with monolayer precision and facilitates the formation of direct correlations between in situ X-ray studies and the more prevalent RHEED investigations. Importantly, because SXRD and RHEED probe different atomic-scale processes during thin film synthesis, their concomitant use enables the extraction of details concerning growth behavior than one cannot determine from either probe alone. We describe the results of such in situ studies on the epitaxial growth of perovskite LaNiO3on (La 0.18 Sr 0.82 )(Al 0.59 Ta 0.41 )O 3 (001). We find that during the earliest stages of growth, the RHEED and X-ray signals do not agree with each other, demonstrating that while regular RHEED oscillations may imply high quality growth, the film-substrate interface can undergo significant changes during deposition due to the occurrence of interdiffusion at the growth temperature.

36 MATERIALS SCIENCE↗

Directional shock diode behavior through the interaction of geometric voids in engineered polymer assemblies

With the advent of additive manufacturing (AM) techniques, a new class of shockwave mitigation and structural supports has been realized through the hierarchical assembly of polymer materials. To date, there have been a limited number of studies investigating the role of structure on shockwave localization and whether AM offers a means to tailor shockwave behavior. Of particular interest is whether the mesoscopic structure can be tailored to achieve shockwave properties in one direction of impact vs the other. In this work, we illustrate directional response in engineered polymer foams. In situ time-resolved x-ray phase contrast imaging at the Advanced Photon Source was used to characterize these diode-like structures. This work offers a breakthrough in materials technology for the development of protective structures that require augmentation of shock in one direction while diminishing transmission in the opposite direction.

42 ENGINEERING↗

Detailed diffraction imaging of x-ray optics crystals with synchrotron radiation

Rocking curve topography at the Advanced Photon Source’s beamline 1-BM measures the x-ray reflection from large (many cm 2 ) flat crystals on a sub-mm scale with microradian angular resolution. The $(01\bar{1}1)$ reflection at 8 keV is uniform across the crystal and close to theory for three thick quartz wafers well-polished with increasingly finer grit. However, the reflection is non-uniform for some ~ 0.1mmthin, bendable crystals that are made flat by optical contact with a flat substrate. Here, these thin crystals are bent to serve in certain x-ray diagnostics of plasmas, and similar non-uniformities could then occur in bent crystals as well. The same detail in x-ray reflection in bent crystals is unachievable with the existing topography setup: one way to get the desired resolution is with a standard microfocusing approach.

47 OTHER INSTRUMENTATION↗

Probing the lattice structure of dynamically compressed and released single crystal iron through the alpha to epsilon phase transition

In this work, experiments using broadband Laue x-ray diffraction (XRD) were used to examine the lattice structure of dynamically compressed [100]-oriented single crystal iron samples at the Dynamic Compression Sector at the Advanced Photon Source. These experiments used 1 μm thick iron single crystal samples sandwiched between a polyimide ablator and a polycarbonate window. A 100 J, 10 ns duration laser pulse incident on the polyimide ablator was used to shock compress the iron samples to initial stresses greater than 25 GPa, exceeding the ~13 GPa alpha (body-centered-cubic or bcc structure) to epsilon (hexagonal-close-packed or hcp structure) phase transition stress. XRD measurements were performed at various times relative to the shock wave entering the iron sample: early times, <~150 ps while the initial shock waves propagated through the iron; intermediate times, after the iron equilibrated with the ablator and window reaching a plateau stress state (12 or 17 GPa) lasting several nanoseconds; and late times, during uniaxial strain release. The early time measurements show that in <~150 ps, the high-pressure hcp phase is relaxed with a c/a ratio of 1.61, contrary to previous laser shock experiments where a c/a ratio of 1.7 was inferred. In the plateau stress state and partially released states, XRD measurements showed that the hcp structure retained a c/a ratio of 1.61 with no observable changes in the microstructure. Upon stress release at ~1 GPa/ns release rate, the reverse phase transition (hcp to bcc) to the original single crystal orientation (implying a transformation memory effect) was observed to reach completion somewhere between 13 and 11 GPa, indicating little stress hysteresis under rapid uniaxial strain release. A similar memory effect for the reverse hcp to bcc transformation has been previously observed under hydrostatic compression. However, the bcc/hcp orientation relationships differ somewhat between dynamic and static compression experiments, implying that the transformation pathway under uniaxial dynamic strain differs from the Burgers mechanism.

36 MATERIALS SCIENCE↗

In Situ X-ray Diffraction of High Density Polyethylene During Dynamic Compression: Polymer Chain Compression and Phase Transformations

Polymers are widely implemented materials often used for safety and security in our daily lives. However, we do not have a thorough understanding of the phase transformations of these materials when exposed to extreme condition, high strain rate, events. To study polymers in these severe environments, we performed plate impact experiments that impart a one-dimensional shock wave, at high pressures and temperatures, to observe the materials response. Generally, velocimetry is the experimental diagnostic used to capture the movement of high velocity interfaces to then calculate the mechanical variables associated with shock compression. However, when a material undergoes a phase transition, such as between two crystalline phases or melting to decomposition during shock compression, velocimetry does not explicitly indicate what structural change occurred. At the Dynamic Compression Sector at the Advanced Photon Source gas gun driven compression has been paired with x-ray diffraction, providing the ability to study both the shock parameters and structural changes concurrently. We explored high density polyethylene (HDPE) both on its reactants Hugoniot (<10.12 GPa) and within its transition region (24.3 GPa) where HDPE is hypothesized to decompose from reactants to products. With x-ray diffraction we observed both polymer chain compression and crystal structure reorientation from orthorhombic to monoclinic above 6 GPa, as well as either a possible phase change or chemical decomposition at 24.3 GPa. With these experiments we were able to determine the crystalline and amorphous Hugoniot loci at pressures below the polymer transition region.

36 MATERIALS SCIENCE↗

Observations on the deformation of metal microspheres in shock-driven polymer flows

We report that solid particles can be fragmented by a fast-moving fluid if their velocity difference is great enough, such as during the atmospheric entry of meteoroids or the shock compression of engineered particulate composites. The extent of particle deformation and breakup in such systems is poorly understood because the necessary extreme conditions make observation difficult and data scarce. To meet this need, experiments combining ultrafast synchrotron-based radiography with plate impact loading were performed at the dynamic compression sector at the advanced photon source. Metal microspheres of several densities and strengths (Au, Ta, and W) were placed inside a polymer matrix. A planar shock wave was then produced in the polymer by the impact of a gun-launched flyer plate. X-ray images of the resulting flow were collected at ~150ns intervals. These images document the progression of particle deformation across a range of flow conditions and particle materials. They show that the extent of deformation is sensitive to the ratio of drag stress to particle strength. The deforming particle's shape is determined by the initial shock–particle interaction, fluid stagnation pressure, and vorticity, each acting on its own timescale. A set of scaling relationships is presented to capture these observations and enable comparison with prior hydrodynamic data. The result is a framework for predicting the conditions under which strong particles are severely deformed by a shock-driven flow.

36 MATERIALS SCIENCE↗

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

Static and shock compression studies of eutectic high-entropy alloy AlCoCrFeNi 2.1 to ultrahigh pressures

The high-entropy alloy with composition AlCoCrFeNi 2.1 , additively manufactured with the laser powder-bed fusion technique, has a far-from-equilibrium BCC/FCC eutectic nanolamellar structure. We studied the high-pressure response of this alloy under both static compression and high-strain rate shock compression. The response to static compression using a diamond anvil cell was studied at pressures up to 302 GPa with synchrotron x-ray diffraction at the advanced photon source. The high-pressure FCC-only phase of the EHEA previously observed by Pope et al. [AIP Adv. 13, 035124 (2023)] is found to be stable up to the highest pressure achieved in this study with a volume compression of V/V 0 = 0.587 at ambient temperature. The shock experiments were performed by using GEKKO XII lasers at the Institute of Laser Engineering, Osaka University. The principal Hugoniot equation-of-state of the EHEA was measured up to a pressure of 515 GPa and a compression of V/V 0 = 0.613. Additionally, the thermal equation of state of the EHEA was measured up to 6.2 GPa and 1623 K using a large-volume Paris–Edinburgh cell to obtain the temperature dependence of bulk modulus and thermal expansion coefficients. The melting temperature for EHEA AlCoCrFeNi 2.1 at a pressure of 5.6 GPa was measured to be 1648 ± 25 K. These results can be used to refine stochastic (or special) quasi-random structure (SQS) models for high-pressure high-temperature behavior of high-entropy alloys.

36 MATERIALS SCIENCE↗

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar↗

Measurements of the inert Hugoniot and observation of mechanical ignition in Ni(V) + Al reactive multilayers via x-ray diffraction

This study investigates the inert Hugoniot response, mechanical ignition, and reaction dynamics of Ni(V)+Al multilayers during longitudinal, laser-driven shock compression experiments. Ni(V)+Al multilayers, known for their self-propagating exothermic reactions, were subjected to longitudinal stresses exceeding 50 GPa using the laser shock facility within the Dynamic Compression Sector (DCS) at the Advanced Photon Source (APS). In situ x-ray diffraction (XRD) revealed that Ni(V) and Al were not in equilibrium during compression, with stress discrepancies attributed to twinning, grain structure effects, and/or dislocation density. However, the measured inert Hugoniot closely matched prior experimental and computational studies, confirming the utility of XRD for measuring the equation of state of thin, complex materials. Additionally, reaction was observed at significantly higher stresses than reported previously using laser-launched flyers. This discrepancy suggests a strong influence of externally imposed shear stress on reaction thresholds, which likely arose from deviations in flyer planarity during past experiments. Full reaction of the multilayer occurred within 40 ns after shock-wave passage, evidenced by complete melting of the constituents. Eulerian hydrocode simulations replicated experimental conditions, providing insights into equilibrium dynamics and experimental artifacts. The results highlight how even small shear forces facilitate ignition in Ni(V)+Al multilayers at lower stresses.

Crystallography↗

Watching a signaling protein function in real time via 100-ps time-resolved Laue crystallography

To understand how signaling proteins function, it is necessary to know the time-ordered sequence of events that lead to the signaling state. We recently developed on the BioCARS 14-IDB beamline at the Advanced Photon Source the infrastructure required to characterize structural changes in protein crystals with near-atomic spatial resolution and 150-ps time resolution, and have used this capability to track the reversible photocycle of photoactive yellow protein (PYP) following trans-to-cis photoisomerization of its p-coumaric acid (pCA) chromophore over 10 decades of time. The first of four major intermediates characterized in this study is highly contorted, with the pCA carbonyl rotated nearly 90° out of the plane of the phenolate. A hydrogen bond between the pCA carbonyl and the Cys69 backbone constrains the chromophore in this unusual twisted conformation. Density functional theory calculations confirm that this structure is chemically plausible and corresponds to a strained cis intermediate. This unique structure is short-lived (~600 ps), has not been observed in prior cryocrystallography experiments, and is the progenitor of intermediates characterized in previous nanosecond time-resolved Laue crystallography studies. The structural transitions unveiled during the PYP photocycle include trans/cis isomerization, the breaking and making of hydrogen bonds, formation/relaxation of strain, and gated water penetration into the interior of the protein. This mechanistically detailed, near-atomic resolution description of the complete PYP photocycle provides a framework for understanding signal transduction in proteins, and for assessing and validating theoretical/computational approaches in protein biophysics.

Schotte, Friedrich↗

Improving Beamline X-ray Optics by Analyzing the Damage to Crystallographic Structure

The mission of the X-ray Characterization Laboratory in the X-ray Science Division (XSD) at the Advanced Photon Source (APS) is to support both the users and the Optics Fabrication Facility that produces high performance optics for synchrotron X-ray beamlines. The Topography Test Unit (TTU) in the X-ray Lab has been successfully used to characterize diffracting crystals and test monochromators by quantifying residual surface stresses. This topographic method has also been adapted for testing standard X-ray mirrors, characterizing concave crystal optics and in principle, can be used to visualize residual stresses on any optic made from single crystalline material. The TTU has been instrumental in quantitatively determining crystal mounting stresses which are mechanically induced by positioning, holding, and cooling fixtures. It is this quantitative aspect that makes topography so useful since the requirements and responses for crystal optics and X-ray mirrors are quite different. In the case of monochromator crystals, even small residual or induced stresses, on the order of tens of kPa, can cause detrimental distortions to the perfect crystal rocking curves. Mirrors, on the other hand, are much less sensitive to induced stresses where stresses that are an order of magnitude greater can be tolerated. This is due to the fact that the surface rather than the lattice-spacing determines a mirror’s performance. For the highly sensitive crystal optics, it is essential to measure the in-situ rocking curves using topographs as mounting fixtures are adjusted. In this way, high heat-load monochromator crystals can be successfully mounted with minimum stress. Topographical analysis has been shown to be a highly effective method to visualize and quantify the distribution of stresses, to help identify methods that mitigate stresses, and most notably to improve diffractive crystal optic rocking curves.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synchrotron Radiation and Neutrons in Art and Archaeology (SR2A) Conference 2016

Here, the seventh edition of the international conference on Synchrotron Radiation and Neutrons in Art and Archaeology (SR2A 2016) was held September 6–8, 2016, at the Stock Exchange Room of The Art Institute of Chicago, USA. The conference was jointly organized by seven research laboratories and museums; more precisely, the Center for Scientific Studies in the Arts (NU-ACCESS) of Northwestern University, the Art Institute of Chicago, the Field Museum Chicago, the Advanced Photon Source (APS), the Oriental Institute Chicago, the Detroit Institute of Arts, and the Indianapolis Museum of Art, in close interaction with the SR2A International Committee. Nine years after the organization of the first SR2A conference in Grenoble, the Art Institute hosted the second biennial interdisciplinary meeting in the US.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗