Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Accurate surface estimation from high-resolution 3D microwave images

Active millimeter and microwave imaging techniques can be used to create a high-resolution 3D image volume of a target’s reflectivity. Millimeter-wave imaging is commonly used for personnel security screening and numerous other applications. Backprojection based image reconstruction techniques form a 3D complex-valued volume. The complex-valued volume is commonly reduced to a real-valued volume by taking the magnitude. For anomaly detection and cross image registration of an object it is beneficial to generate an accurate representation of an object’s surface. Extracting a smooth and accurate surface from a magnitude only image is challenging. One difficulty is the magnitude image has limited resolution in the depth direction which normally limits precision to a moderate fraction of the depth resolution. Another difficulty is that the magnitude of the image depends heavily on the geometry and orientation of the object being imaged. The phase information in a complex-valued image volume provides a means to decouple the magnitude of the image from the geometry of an object and provide precision much finer than the depth resolution would indicate. This enables the generation of a smooth and accurate point cloud representation of the surface of an imaged object. A method to extract a point cloud from the phase information in a 3D complex-valued millimeter-wave image volume is developed and results with simulated and experimental data are presented.

Clark, Richard T.↗

Measurement of 2D density profiles using a second-harmonic, dispersion interferometer

A second-harmonic, dispersion interferometer is used to image large-area (≃5 cm 2 ) plasma-jet and gas-jet density profiles. Achromatic telescopes magnify the diameters of the primary-laser beam (1064 nm) and its second-harmonic (532 nm) before probing the sample and de-magnify the beam diameters after the sample, where the primary beam transfers its phase change to a second, second-harmonic beam, allowing the sample’s dispersive-phase change to be measured between two, orthogonally polarized second harmonic beams. The telescopes produce an azimuthally symmetric, dispersive-phase shift in the sample + background phase-change image and in the background phase-change image, which is removed by digital subtraction. The interferometer’s performance was verified using standard-optical components as dispersive elements (BK7 lenses and wedge plates), resolving a minimum, phase-change sensitivity of ΔΦ min ≳ 15 mrad and spatial resolution of Δx res ≃ 100 μm. The phase change produced by unknown-density objects (a pulsed-plasma-jet and a pulsed-gas-jet) was measured, and their data were used to recover the original, 2D density profiles using an inverse Abel transform: peak-number density, N gas ≃ 6 × 10 20 cm –3 and N e ≃ 5 × 10 16 cm –3 ; line-integrated density, ∫N gas dl ~ 2 × 10 19 cm –2 and ∫N e dl ~ 1 × 10 16 cm –2 . The techniques and methods developed here are scalable to even larger probe-beam diameters and frame-capture rates, leading to a diagnostic capability that is well-suited for applications involving the real-time measurement of density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Integrated High-Speed Microstructural Characterization Method Using Simultaneous XRD, Stereo-DIC, and PCI

High-speed characterization of the deformation mechanisms in polycrystalline metals requires the quantification of full strain fields and local microstructural evolutions simultaneously. In this paper, we present a novel experimental method to integrate phase-contrast imaging (PCI), stereographic digital image correlation (stereo-DIC), and full-ring X-ray diffraction (XRD) to allow for the simultaneous characterization of polycrystalline metals at 1MHz or higher. A Kolsky bar was integrated into the synchrotron X-ray source in Sector 32 ID-B at the Advance Photon Source (APS) at Argonne National Laboratory. When the sample is dynamically loaded, the diagnostic methods of full-ring XRD, PCI, and stereo-DIC are properly synchronized to record the deformation behavior at both continuum and microstructural scales as a function of the loading history. An advanced high-strength steel (AHSS) is used as a model material to demonstrate the capabilities of this new experimental method.

36 MATERIALS SCIENCE↗

Real-time visualization of dynamic particle contact failures

Granular materials are widely used to resist impact and blast. Under these dynamic loadings, the constituent particles in the granular system fracture. To study the fracture mechanisms in brittle particles under dynamic compressive loading, a high speed X-ray phase contrast imaging setup was synchronized with a Kolsky bar apparatus. Controlled compressive loading was applied on two contacting particles using the Kolsky bar apparatus and fracture process was captured using the high speed X-ray imaging setup. Five different particles were investigated: soda-lime glass, polycrystalline silica (silicon dioxide), polycrystalline silicon, barium titanate glass, and yttrium stabilized zirconia. For both soda lime glass and polycrystalline silica particles, one of the particles fragmented explosively, thus breaking into many small pieces. For Silicon and barium titanate glass particles, a finite number of cracks were observed in one of the particles causing it to fracture. For yttrium stabilized zirconia particles, a single meridonial crack developed in one of the particles, breaking it into two parts.

36 MATERIALS SCIENCE↗

Time-resolved 3D imaging of two-phase fluid flow inside a steel fuel injector using synchrotron X-ray tomography

The multiphase flow inside a diesel injection nozzle is imaged using synchrotron X-rays from the Advanced Photon Source at Argonne National Laboratory. Through acquisitions performed at several viewing angles and subsequent tomographic reconstruction, in-situ 3D visualization is achieved for the first time inside a steel injector at engine-like operating conditions. The morphology of the internal flow reveals strong flow separation and vapor-filled cavities (cavitation), the degree of which correlates with the nozzle's asymmetric inlet corner profile. Micron-scale surface features, which are artifacts of manufacturing, are shown to influence the morphology of the resulting liquid-gas interface. The data obtained at 0.1 ms time resolution exposes transient flow features and the flow development timescales are shown to be correlated with in-situ imaging of the fuel injector's hydraulically-actuated valve (needle). As more than 98.5% of the X-ray photon flux is attenuated within the steel injector body itself, we are posed with a unique challenge for imaging the flow within. Time-resolved imaging under these low-light conditions is achieved by exploiting both the refractive and absorptive properties of X-ray photons. The data-processing strategy converted these images with a signal-to-noise ratio of similar to 10 into a meaningful dataset for understanding internal flow and cavitation in a nozzle of diameter 200 mu m enclosed within 1-2 millimeters of steel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spherical grating based x-ray Talbot interferometry

Purpose: Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme for a wider range of preclinical and clinical applications. Methods: A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Results: Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh–Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. Conclusions: X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and improves both signal visibility and dose utilization for pre-clinical and clinical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative evaluation of mask phase defects from through-focus EUV aerial images

Mask defects inspection and imaging is one of the most important issues for any pattern transfer lithography technology. This is especially true for EUV lithography where the wavelength-specific properties of masks and defects necessitate actinic inspection for a faithful prediction of defect printability and repair performance. In this paper we will present a technique to obtain a quantitative characterization of mask phase defects from EUV aerial images. We apply this technique to measure the aerial image phase of native defects on a blank mask, measured with the SEMATECH Berkeley Actinic Inspection Tool (AIT) an EUV zoneplate microscope that operates at Lawrence Berkeley National Laboratory. The measured phase is compared with predictions made from AFM top-surface measurements of those defects. While amplitude defects are usually easy to recognize and quantify with standard inspection techniques like scanning electron microscopy (SEM), defects or structures that have a phase component can be much more challenging to inspect. A phase defect can originate from the substrate or from any level of the multilayer. In both cases its effect on the reflected field is not directly related to the local topography of the mask surface, but depends on the deformation of the multilayer structure. Using the AIT, we have previously showed that EUV inspection provides a faithful and reliable way to predict the appearance of mask defect on the printed wafer; but to obtain a complete characterization of the defect we need to evaluate quantitatively its phase component. While aerial imaging doesn't provide a direct measurement of the phase of the object, this information is encoded in the through focus evolution of the image intensity distribution. Recently we developed a technique that allows us to extract the complex amplitude of EUV mask defects using two aerial images from different focal planes. The method for the phase reconstruction is derived from the Gerchberg-Saxton (GS) algorithm, an iterative method that can be used to reconstruct phase and amplitude of an object from the intensity distributions in the image and in the pupil plane. The GS algorithm is equivalent to a two-parameter optimization problem and it needs exactly two constraints to be solved, namely two intensity distributions in different focal planes. In some formulations, adding any other constraint would result in an ill posed problem. On the other hand, the solution's stability and convergence time can both be improved using more information. We modified our complex amplitude reconstruction algorithm to use an arbitrary number of through focus images and we compared its performance with the previous version in terms of convergence speed, robustness and accuracy. We have demonstrated the phase-reconstruction method on native, mask-blank phase defects and compared the results with phase-predictions made from AFM data collected before and after the multilayer deposition. The method and the current results could be extremely useful for improving the modeling and understanding of native phase defects, their detectability, and their printability.

36 MATERIALS SCIENCE↗

Neutron imaging experiments at E-12 beam-line of CIRUS

Neutron imaging beam-line at E-12 beam port of CIRUS reactor India has been developed to implement Neutron tomography, phase contrast imaging and dynamic imaging techniques for various applications. Several experiments on these techniques have been carried out successfully. Neutron radiography and tomography has been used to study blisters formation in pressure tube along with many other applications. Similarly phase contrast imaging has been used to study its feasibility for better contrast in radiographic images. Dynamic imaging has been applied to study the melting of pure and impure lead under heat. In this paper we report the details of various experiments performed at this beam-line.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of fluorite-structured ferroelectrics using transmission electron microscopy: Techniques, challenges, and recent advances

Fluorite-structured ferroelectrics, such as hafnium oxide and its alloyed variants, are key candidates for next-generation memory devices. Yet, fundamental questions about switching mechanisms, domain dynamics, and phase evolution remain open. Transmission electron microscopy (TEM) provides unique capabilities to address these challenges by simultaneously resolving the positions of anions and cations, chemical variations, and structural transformations. Recent advances—including in situ heating, electron beam-induced switching, electron energy loss spectroscopy, and differential phase contrast imaging—have revealed critical insights into phase transitions, potential switching pathways, and oxygen vacancy behavior. However, experimental barriers such as TEM sample-preparation-induced artifacts, high coercive fields, and imaging constraints persist, especially for polycrystalline films. By offering a focused overview of current TEM developments in fluorite ferroelectrics, this work outlines how TEM contributes to understanding key phenomena and proposes a roadmap for future studies.

36 MATERIALS SCIENCE↗

Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry

After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase Calibration Of Polarimetric Radar Images

Report addresses problem of calibration of differences between phases (relative to transmitted signals) of signals received in two polarization channels of polarimetric imaging radar system. Causes of various types of errors discussed. Calibration necessary to deduce information about target area - type of terrain, presence of vegetation, and land/water boundaries.

Freeman, Anthony↗

Estimation of the sugar cane cultivated area from LANDSAT images using the two phase sampling method

A two phase sampling method and the optimal sampling segment dimensions for the estimation of sugar cane cultivated area were developed. This technique employs visual interpretations of LANDSAT images and panchromatic aerial photographs considered as the ground truth. The estimates, as a mean value of 100 simulated samples, represent 99.3% of the true value with a CV of approximately 1%; the relative efficiency of the two phase design was 157% when compared with a one phase aerial photographs sample.

Parada, N. D. J.↗

Picosecond phase-velocity dispersion of hypersonic phonons imaged with ultrafast electron microscopy

We describe the direct imaging—with four-dimensional ultrafast electron microscopy—of the emergence, evolution, dispersion, and decay of photoexcited, hypersonic coherent acoustic phonons in nanoscale germanium wedges. Coherent strain waves generated via ultrafast in situ photoexcitation were imaged propagating with initial phase velocities of up to 35 km/s across discrete micrometer-scale crystal regions. We then observe that, while each wave front travels at a constant velocity, the entire wave train evolves with a time-varying phase-velocity dispersion, displaying a single-exponential decay to the longitudinal speed of sound (5 km/s) and with a mean lifetime of 280 ps. We also find that the wave trains propagate along a single in-plane direction oriented parallel to striations introduced during specimen preparation, independent of crystallographic direction. Elastic-plate modeling indicates the dynamics arise from excitation of a single, symmetric (dilatational) guided acoustic mode. Further, by precisely determining the experiment time-zero position with a plasma-lensing method, we find that wave-front emergence occurs approximately 100 ps after femtosecond photoexcitation, which matches well with Auger recombination times in germanium. We conclude by discussing the similarities between the imaged hypersonic strain-wave dynamics and electron/hole plasma-wave dynamics in strongly photoexcited semiconductors.

36 MATERIALS SCIENCE↗

Shock compression of a low-density carbon foam

Porous polymer foams are found in numerous applications where they may be subjected to dynamic compression. The shockwave properties of polymer foams have several features that make shock Hugoniot measurements and interpretation challenging. Here, we present a comparison of dynamic X-ray phase contrast imaging and traditional optical velocimetry approaches to measuring the shocked states for a low-density carbon foam. Overall, dynamic X-ray phase contrast imaging was found to reduce errors associated with the measured Hugoniot states. In this study, the foam exhibits anomalous compression as expected due to its high initial porosity arising from shock heating.

36 MATERIALS SCIENCE↗

Shock-induced bubble jets: a dual perspective of bubble collapse and interfacial instability theory

Interactions between shock waves and gas bubbles in a liquid can lead to bubble collapse and high-speed liquid jet formation, relevant to biomedical applications such as shock wave lithotripsy and targeted drug delivery. This study reveals a complex interplay between acceleration-induced instabilities that drive jet formation and radial accelerations causing overall bubble collapse under shock wave pressure. Using high-speed synchrotron X-ray phase contrast imaging, the dynamics of micrometre-sized air bubbles interacting with laser-induced underwater shock waves are visualised. These images offer full optical access to phase discontinuities along the X-ray path, including jet formation, its propagation inside the bubble, and penetration through the distal side. Jet formation from laser-induced shock waves is suggested to be an acceleration-driven process. A model predicting jet speed based on the perturbation growth rate of a single-mode Richtmyer–Meshkov instability shows good agreement with experimental data, despite uncertainties in the jet-driving mechanisms. The jet initially follows a linear growth phase, transitioning into a nonlinear regime as it evolves. To capture this transition, a heuristic model bridging the linear and nonlinear growth phases is introduced, also approximating jet shape as a single-mode instability, again matching experimental observations. Upon piercing the distal bubble surface, jets can entrain gas and form a toroidal secondary bubble. Linear scaling laws are identified for the pinch-off time and volume of the ejected bubble relative to the jet’s Weber number, characterising the balance of inertia and surface tension. At low speeds, jets destabilise due to capillary effects, resulting in ligament pinch-off.

Drops and Bubbles: Bubble dynamics↗