Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗

Measuring the Aerosol Collection Efficiency and Detector Face Deposition of the Bladewerx KatanaGBM™ (Glove Box Monitor) Continuous Air Monitor

To assist Bladewerx LLC (the Requestor) in testing their new CAM (continuous air monitor) sampler model Bladewerx™ KatanaGBM™ (Glove Box Monitor), the Laboratory (LANL, i.e. Los Alamos National Laboratory) measured the aerosol particle collection efficiency and detector face deposition for several experimental test conditions. Bladewerx LLC provided a prototype KatanaGBM with a set of requested tests. According to these parameters, LANL designed and performed a series of experiments to (A.) Measure the aerosol particle collection efficiency and detector face deposition of the KatanaGBM at three air flow rates of 5, 42, and 70 ALPM (ambient liters per minute), (B.) Measure the collection efficiency and detector face deposition using two sizes of oil droplet particles: 3±1 and 10±1 µm (micron) AED (aerodynamic equivalent diameter), and (C.) Test the KatanaGBM for aerosol collection efficiency and detector face deposition with the wind tunnel’s air flow at three different angles 0°, 45° and 90° (compared to the KatanaGBM’s filter face).

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing a Hazmatpac Can with Locking Ring as a Secondary Shipping Container for Radium-224/Lead-212 Generators

A Hazmatpac can, paint can style shipping container with locking ring, was tested for use as an alternative shipping configuration for shipment of radium- 224 /lead- 212 generators. 224 Ra ( t 1/2 = 3.63 d) decays by alpha emission to radon-220 ( t 1/2 = 55.6 s). The potential for the radioactive radon gas to escape the generator column and the shipping container is of particular concern for the safe delivery of 224 Ra/ 212 Pb generators to customers. The purpose of this study was to evaluate whether the Hazmatpac can is a suitable shipping configuration, capable of containing the radon gas that may escape the generator column during transit. A 17.3 mCi 224 Ra/ 212 Pb generator was built and packaged into a Hazmatpac can. The can was smeared by a Radiological Control Technician (RCT) every day for seven days to analyze for radioactive contamination on the outside of the can. Over the course of the study, no radioactive contamination was found on the outside of the can. Therefore, the Hazmatpac can was approved as an alternative shipping configuration for shipment of 224 Ra/ 212 Pb generators.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dose Exceedance Distance Sensitivity Based on Parametric Uncertainty

Sandia National Laboratories (SNL) collaborated with the US Nuclear Regulatory Commission's (NRC) Office of Nuclear Security and Incident Response (NSIR) and Office of Nuclear Regulatory Research (RES) to investigate the reasonable variability in the estimation of dose exceedance distances. SNL performed calculations using the MACCS code to elucidate the sensitivity of dose exceedance distances to variations in user input parameters.

61 RADIATION PROTECTION AND DOSIMETRY↗

AMS Joint/Bilateral Surveys

A historical presentation depicting the International Joint Aerial Surveys AMS has co-created and collaborative efforts that were implemented as result of those efforts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Explicit Dynamic Impact Analysis of the Building 3525 Packages

This report describes the methodology used for the safety basis analysis of the Building (Bldg.) 3525 casks and presents preliminary results for a selected geometry. The specific problem analyzed is a free fall load case onto an unyielding target at various orientations. The various orientations were analyzed to ensure that the packages were subjected to the orientation that causes the most damage. The analysis approach, material modeling, finite element modeling, and results for the selected case are presented, along with a brief discussion of conservatism and uncertainties. The results for the analyzed load cases show that through selected administrative controls, no breach of the container or loss of shielding will occur in the package.

42 ENGINEERING↗

1FRAME - 1F Fuel Retrieval and Monitoring Experiments [Poster]

The 1FRAME (1F Fuel Retrieval and Monitoring Experiments) project includes collaborative research and development in the area of neutron detection, analysis, and simulations for fuel debris removal at Fukushima Daiichi nuclear power station. Technical advances are needed in all three focus areas to provide technical recommendations on a course of action for fuel debris removal. This work is part of collaborative research and development efforts between the US, Japan, and France.

Fuel Debris Removal↗

Improved PARE (Pressurized Airborne Release Equipment) for ARF (Airborne Release Fraction) and RF (Respirable Fraction) Testing

An improved version of the PARE (Pressurized Airborne Release Equipment) system (Sutter 1983a and Sutter 1983b and Ballinger et al 1987) has been developed for powder venting testing. This effort seeks to improve the accuracy of risk estimation for the venting of pressurized powders and the venting of gases through pressurized powders.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced Test Reactor Neutron Dosimetry Report - 173B (Rev. 1)

Results of neutron dosimetry measurements in ATR for cycle 173B-1&2 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

173B↗

Microreactor Incident-Free Transportation Radiation Dose Assessment

This report, prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Nuclear Regulatory Commission, provides an estimate of the radiation dose related to the transportation of microreactors following the regulatory limits established in Title 10 of the Code of Federal Regulations (10 CFR) 71.47(b). The transportation of irradiated microreactors poses unique challenges. Microreactors may be challenged to meet the current 10 mrem/hr limit at 2 meters from the vehicle in 10 CFR 71.47(b). The need to modify packaging to be within practical weight and size limits for shipping may limit the amount of shielding that can be applied for a microreactor transportation package design. Operational strategies that would necessitate moving a reactor within a short time after its operating life may result in higher radiation dose rates associated with lower cooling times. This study estimates the radiation dose to maximally exposed individuals (MEIs) under the current regulatory radiation level limit of 10 mrem/hr at 2 meters from the vehicle as well as alternative limits of 10, 50, 100, and 200 mrem/hr at 2 meters from the vehicle. This analysis expands on prior incident free transportation radiation dose assessments conducted for spent nuclear fuel (SNF) and radioactive waste transportation. The key factors analyzed include the microreactor fuel type and burnup, shipment cooling periods, shielding designs integrated into transport packaging, and exposure scenarios for MEIs for highway and rail transport. This report considers additional distances that may be associated with compensatory measures to ensure safe transport conditions under varying radiation dose limits, including enhanced routing measures, escort protocols, vehicle inspections, and operational restrictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

ACRRF High-Bay Dose Calculations using MCNP (Part B)

ACRR radiation outputs through vertical cavities have been documented in two reports. In Part B, the maximum dose from the unshielded central cavity, FREC-II, and NRS is calculated to inform the safety basis. The maximum dose is ≈1430 mrem per 300 MJ, or ≈40,930 rem/hr for full-power operation. A verification study completes the V&V of the modeling. Supplementary studies of variance-reduction techniques, model sensitivities, and aircraft dose above the ACRRF are included.

61 RADIATION PROTECTION AND DOSIMETRY↗

User’s Manual for RESRAD-RDD&IND Code Version 2: Vol. 1—Methodology and Models Used in RESRAD-RDD&IND Code

RESRAD-RDD&IND is part of the RESRAD family of codes that Argonne National Laboratory developed for the U.S. Department of Energy (DOE). An earlier version, RESRAD-RDD published in 2009, dealt only with radiological dispersal device (RDD) incidents (DOE 2009). This new version, RESRAD-RDD&IND, is designed to evaluate both RDD incidents and improvised nuclear device (IND) incidents. This report is Volume 1 of the RESRAD-RDD&IND User’s Manual that documents the methodology, models, and radionuclide-specific data used in RESRAD-RDD&IND code Version 2.0. Volume 2 of the RESRAD-RDD&IND User’s Manual is called the User’s Guide for RESRAD-RDD&IND Code . It describes how to use RESRAD-RDD&IND code Version 2.0 and includes screen shots and parameter information.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Worst Case Sabotage Consequence Modeling for Advanced Reactors

Under proposed rulemaking by the United States Nuclear Regulatory Commission, advanced reactor licensees may qualify for a reduction in onsite responders if the consequences from a sabotage attack do not exceed 25 rem at the reactor site boundary 2 hours after a release occurs. This work presents a preliminary assessment of the feasibility of meeting the 25 rem at the site boundary criteria. Using advanced reactor radionuclide inventories radiological release estimates created by collaborators at Oak Ridge National Laboratory, the MACCS consequence analysis code was used to investigate the distance at the dose from hypothetical sabotage events reaches 25 rem for different advanced reactor technologies. It was found that the distance to 25 rem depended heavily on sampled weather conditions and sabotage release fractions, and further refinement of release fractions and MACCS modeling parameters is recommended.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗