Forced convection and flow boiling with and without enhancement devices for top-side-heated horizontal channels

The effect of enhancement devices on flow boiling heat transfer in coolant channels, which are heated either from the top side or uniformly was studied. Studies are completed of the variations in the local (axial and circumferential) and mean heat transfer coefficients in horizontal, top-heated coolant channels with smooth walls and internal heat transfer enhancement devices. The working fluid is freon-11. The objectives are to: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls or with both a twisted tape and spiral finned walls; (2) examine the effect of channel diameter (and the length-to-diameter aspect ratio) variations for the smooth wall channel; and (3) develop and improved data reduction analysis. The case of the top-heated, horizontal flow channel with smooth wall (1.37 cm inside diameter, and 122 cm heated length) was completed. The data were reduced using a preliminary analysis based on the heated hydraulic diameter. Preliminary examination of the local heat transfer coefficient variations indicated that there are significant axial and circumferential variations. However, it appears that the circumferential variation is more significant than the axial ones. In some cases, the circumferential variations were as much as a factor of ten. The axial variations rarely exceeded a factor of three.

Boyd, Ronald D., Sr.↗

Subcooled freon-11 flow boiling in top-heated finned coolant channels with and without a twisted tape

An experimental study was conducted in top-heated finned horizontal tubes to study the effect of enhancement devices on flow boiling heat transfer in coolant channels. The objectives are to examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for circular coolant channels with spiral finned walls and/or spiral fins with a twisted tape, and improve the data reduction technique of a previous investigator. The working fluid is freon-11 with an inlet temperature of 22.2 C (approximately 21 C subcooling). The coolant channel's exit pressure and mass velocity are 0.19 M Pa (absolute) and 0.21 Mg/sq. ms, respectively. Two tube configurations were examined; i.e., tubes had either 6.52 (small pitch) or 4.0 (large pitch) fins/cm of the circumferential length (26 and 16 fins, respectively). The large pitch fins were also examined with a twisted tape insert. The inside nominal diameter of the copper channels at the root of the fins was 1.0 cm. The results show that by adding enhancement devices, boiling occurs almost simultaneously at all axial locations. The case of spiral fins with large pitch resulted in larger mean (circumferentially averaged) heat transfer coefficients, h sub m, at all axial locations. Finally, when twisted tape is added to the tube with large-pitched fins, the power required for the onset of boiling is reduced at all axial and circumferential locations.

Smith, Alvin↗

Bearing Tester Data Compilation Analysis, and Reporting and Bearing Math Modeling

The magnitude and direction of fluid induced torques and forces on the 57 mm bearing cage is considered to be a contributing factor in possible cage instabilities that can produce intermittent high heating in the bearing. Analyses of the fluid forces and torques are presented. Heat generated by viscous fluid work was estimated for two flow diverter configurations and a coolant flow of 10 lbs/sec to support the thermal evaluation of the LOX Bearing Materials Tester. Results of the analysis of the LOX turbopump turbine end bearings are discussed. Coolant velocities for the no. 4 LOX turbopump turbine end bearings were estimated as a function of shaft speed and coolant flow rate. Contact angles and track width data were developed for the 57 mm bearing as functions of shaft speed, and axial and radial loads. The Advanced Dynamics of Rolling Elements (ADORE) computer program was installed on the MSFC UNIVAC 1100 and a test case successfully run. Both the text output and the plotting output were verified. The Bearing Seal and Materials Tester - Test Condition Data Base was developed. The parametric analysis of the operating characteristics of the LOX turbopump pump end bearing using the 45 mm bearing thermal model was begun.

Source record↗

Influence of geometric features on the performance of pressure-swirl atomizers

The spray characteristics of several different simplex pressure-swirl nozzles are examined using water as the working fluid. Measurements of mean drop size, drop-size distribution, effective spray cone angle, and circumferential liquid distribution are carried out over wide ranges of injection pressure. Eight different nozzles are employed in order to achieve a wide variation in the length/diameter ratio of the final discharge orifice. Generally, it is found that an increase in discharge orifice length/diameter ratio, l(o)/d(o), increases the mean drop size in the spray and reduces the spray cone angle. The circumferential liquid distribution is most uniform when l(o)/d(o) = 2. If l(o)/d(o) is raised above or lowered below this optimum value, the circumferential uniformity of the liquid distribution is impaired. The observed effects of l(o)/d(o) on spray characteristics are generally the same regardless of whether the change in l(o)/d(o) is accomplished by varying l(o) or d(o).

Chen, S. K.↗

Startup of a frozen heat pipe in one-g and micro-g environments - A proposed shuttle flight experiment

An attempt is made to determine how a heat pipe freezes under various low load and/or no load conditions in both one-g and micro-g environments. Also of interest are the mechanisms that can be used to restart the heat pipe after freezing has occurred. Particular attention is given to step function power reductions and the resulting distribution of the working fluid after freezing has occurred and the effect of noncondensible gases on the frozen configuration and the restart characteristics.

Ochterbeck, J. M.↗

Development of the Single Graded Groove high-performance heat pipe

This paper describes the development of a new nonarterial heat pipe with a nominal transport capability of 100,000 W in. Data are presented for one-g transport capability as a function of tilt and working fluid quantity. The transport capability agrees well with theoretical predictions. The LMSC Graded Groove Heat Pipe exhibits the high throughput and excellent heat transfer characteristics of earlier arterial designs such as the LMSC Tapered Artery Heat Pipe. At the same time, it suffers none of the priming difficulties associated with the arterial designs.

Ambrose, J. H.↗

A nuclear driven metallic vapor MHD coupled with MPD thrusters

Nuclear energy as a source of power for space missions, represents an enabling technology for advanced and ambitious space applications. Nuclear fuel in a gaseous or liquid form has been configured as a promising and practical candidate in this regard. The present study investigates and performs a feasibility analysis of an innovative concept for space power generation and propulsion. The system embodies a conceptual nuclear reactor with an MHD generator and coupled to MPD thrusters. The reactor utilizes liquid uranium in droplet form as fuel and superheated metallic vapor as the working fluid. This ultrahigh temperature vapor core reactor brings forward varied and challenging technical issues, and it has been addressed to in this paper. A parametric study of the conceived system has been performed in a qualitative and quantitative manner. Preliminary results show enough promise for further indepth analysis of this novel system.

Anghaie, Samim↗

Characteristics and performance of the variable polarity plasma arc welding process used in the Space Shuttle external tank

Significant advantages of the Variable Polarity Plasma Arc (VPPA) Welding Process include faster welding, fewer repairs, less joint preparation, reduced weldment distortion, and absence of porosity. Flow profiles and power distribution of argon plasma gas as a working fluid to produce plasma arc jet in the VPPA welding process was analyzed. Major loss of heat transfer for flow through the nozzle is convective heat transfer; for the plasma jet flow between the outlet of the nozzle and workpiece is radiative heat transfer; and for the flow through the keyhole of the workpiece is convective heat transfer. The majority of the power absorbed by the keyhole of the workpiece is used for melting the solid metal workpiece into a molten metallic puddle. The crown and root widths and the crown and root heights can be predicted. An algorithm for promoting automatic control of flow parameters and the dimensions of the final product of the welding specification to be used for the VPPA Welding System operated at MSFC are provided.

Hung, R. J.↗

Thermal control systems for low-temperature heat rejection on a lunar base

One of the important issues in the lunar base architecture is the design of a Thermal Control System (TCS) to reject the low temperature heat from the base. The TCS ensures that the base and all components inside are maintained within the operating temperature range. A significant portion of the total mass of the TCS is due to the radiator. Shading the radiation from the sun and the hot lunar soil could decrease the radiator operating temperature significantly. Heat pumps have been in use for terrestrial applications. To optimize the mass of the heat pump augmented TCS, all promising options have to be evaluated and compared. Careful attention is given to optimizing system operating parameters, working fluids, and component masses. The systems are modeled for full load operation.

Sridhar, K. R.↗

A Local Condensation Analysis Representing Two-phase Annular Flow in Condenser/radiator Capillary Tubes

NASA's effort for the thermal environmental control of the Space Station Freedom is directed towards the design, analysis, and development of an Active Thermal Control System (ATCS). A two phase, flow through condenser/radiator concept was baselined, as a part of the ATCS, for the radiation of space station thermal load into space. The proposed condenser rejects heat through direct condensation of ATCS working fluid (ammonia) in the small diameter radiator tubes. Analysis of the condensation process and design of condenser tubes are based on the available two phase flow models for the prediction of flow regimes, heat transfer, and pressure drops. The prediction formulas use the existing empirical relationships of friction factor at gas-liquid interface. An attempt is made to study the stability of interfacial waves in two phase annular flow. The formulation is presented of a stability problem in cylindrical coordinates. The contribution of fluid viscosity, surface tension, and transverse radius of curvature to the interfacial surface is included. A solution is obtained for Kelvin-Helmholtz instability problem which can be used to determine the critical and most dangerous wavelengths for interfacial waves.

Karimi, Amir↗

A study of start-up characteristics of a potassium heat pipe from the frozen state

The start up characteristics of a potassium heat pipe were studied both analytically and experimentally. Using the radiation heat transfer mode the heat pipe was tested in a vacuum chamber. The transition temperature calculated for potassium was then compared with the experimental results of the heat pipe with various heat inputs. These results show that the heat pipe was inactive until it reached the transition temperature. In addition, during the start up period, the evaporator experienced dry-out with a heat input smaller than the capillary limit calculated at the steady state. However, when the working fluid at the condensor was completely melted, the evaporation was rewetted without external aid. The start up period was significantly reduced with a large heat input.

Jang, Jong Hoon↗

Results from the LDEF/A0076 cascaded variable conductance heatpipe experiment

The A0076 Variable Conductance Heat Pipe Experiment (CVCHPE) on the Long Duration Exposure Facility (LDEF) demonstrated temperature control better than +/- 0.3 C during fifty days on on-orbit data collection in a widely varying external environment. The experiment used two series connected, dry reservoir variable conductance heat pipes which require no electrical power for operation. The heat pipes used a central artery design with ammonia working fluid and nitrogen control gas. The LDEF was in orbit for almost six years rather than the planned one year mission. Although no additional data were taken during this extended period, post-test data indicated that the set point drifted upward less than 1 C per year. There were significant changes to the appearance of all external thermal control surfaces primarily due to atomic oxygen degradation, and one small anomaly in the electronics. These changes, though, had little effect on the CVCHPE performance.

Grote, Michael G.↗

NASA Lewis steady-state heat pipe code users manual

The NASA Lewis heat pipe code was developed to predict the performance of heat pipes in the steady state. The code can be used as a design tool on a personal computer or with a suitable calling routine, as a subroutine for a mainframe radiator code. A variety of wick structures, including a user input option, can be used. Heat pipes with multiple evaporators, condensers, and adiabatic sections in series and with wick structures that differ among sections can be modeled. Several working fluids can be chosen, including potassium, sodium, and lithium, for which monomer-dimer equilibrium is considered. The code incorporates a vapor flow algorithm that treats compressibility and axially varying heat input. This code facilitates the determination of heat pipe operating temperatures and heat pipe limits that may be encountered at the specified heat input and environment temperature. Data are input to the computer through a user-interactive input subroutine. Output, such as liquid and vapor pressures and temperatures, is printed at equally spaced axial positions along the pipe as determined by the user.

Tower, Leonard K.↗

Solar thermal energy receiver

A plurality of heat pipes in a shell receive concentrated solar energy and transfer the energy to a heat activated system. To provide for even distribution of the energy despite uneven impingement of solar energy on the heat pipes, absence of solar energy at times, or failure of one or more of the heat pipes, energy storage means are disposed on the heat pipes which extend through a heat pipe thermal coupling means into the heat activated device. To enhance energy transfer to the heat activated device, the heat pipe coupling cavity means may be provided with extensions into the device. For use with a Stirling engine having passages for working gas, heat transfer members may be positioned to contact the gas and the heat pipes. The shell may be divided into sections by transverse walls. To prevent cavity working fluid from collecting in the extensions, a porous body is positioned in the cavity.

Baker, Karl W.↗

Dynamic Modeling of Solar Dynamic Components and Systems

The purpose of this grant was to support NASA in modeling efforts to predict the transient dynamic and thermodynamic response of the space station solar dynamic power generation system. In order to meet the initial schedule requirement of providing results in time to support installation of the system as part of the initial phase of space station, early efforts were executed with alacrity and often in parallel. Initially, methods to predict the transient response of a Rankine as well as a Brayton cycle were developed. Review of preliminary design concepts led NASA to select a regenerative gas-turbine cycle using a helium-xenon mixture as the working fluid and, from that point forward, the modeling effort focused exclusively on that system. Although initial project planning called for a three year period of performance, revised NASA schedules moved system installation to later and later phases of station deployment. Eventually, NASA selected to halt development of the solar dynamic power generation system for space station and to reduce support for this project to two-thirds of the original level.

Hochstein, John I.↗

Development of a nonazeotropic heat pump for crew hygiene water heating

A heat pump system is currently under development to produce hot water for crew hygiene on future manned space missions. The heat pump uses waste heat sources and a nonazeotropic working fluid in a highly efficient cycle. The potential benefits include a reduction in peak power draw from 2 to 5 kW for electric cartridge heaters to just more than 100 W for the heat pump. As part of the heat pump development project, a unique high efficiency compressor was developed to maintain lubrication in a zero-gravity environment.

Walker, David H.↗

Compatibility testing with anhydrous ammonia

Anhydrous ammonia has been proposed as the working fluid for a number of two-phase thermal control systems to be used in future space applications, including the Space Station Freedom and the Earth Observing Station (EOS). The compatibility of ammonia with the components in these systems is a major concern due to the corrosive nature of the fluid. Compatibility of ammonia with stainless steel and some aluminum alloys is well documented; however, data on other materials potentially suitable for aerospace use is less common. This paper documents the compatibility testing of nine materials with both gaseous and liquid ammonia. The test procedures are presented along with the resulting measurement data. Tensile strength was the only mechanical property tested that indicated a significant material incompatibility.

Steve M. Benner↗

Test results of prototype two-phase reservoirs for the CAPL flight experiment

The Capillary Pumped Loop Flight Experiment (CAPL) was designed to test components being considered for inclusion in the Earth Observing System (EOS) instrument thermal control system. The thermal operating conditions of a capillary pumped loop (CPL) heat transport system are controlled by a two-phase reservoir. Three prototype two-phase reservoirs designed for use in microgravity applications were built to CAPL specifications and performance tested at NASA Goddard Space Flight Center using anhydrous ammonia as the working fluid. Test results for liquid expulsion rates and CPL operational control are presented for each reservoir.