Search NASA⌕ Search

SEARCH · Search NASA

Results for “api”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Cross-facility science with the Superfacility Project at LBNL

As data sets from DOE user science facilities grow in both size and complexity there is an urgent need for new capabilities to transfer, analyze and manage the data underlying scientific discoveries. LBNL's Superfacility project brings together experimental and observational research instruments with computational and network facilities at the National Energy Research Scientific Computing Center (NERSC) and the Energy Sciences Network (ESnet) with the goal of enabling user science. Here, we report on recent innovations in the Superfacility project, including advanced data management, API-based automation, real-Time interactive user interfaces, and supported infrastructure for 'edge' services.

Enders, B↗

Flaw Stability Considering Residual Stress for Aging Management of Spent Nuclear Fuel Multiple-Purpose Canisters

A typical multipurpose canister (MPC) is made of austenitic stainless steel and is loaded with spent nuclear fuel assemblies. Because heat treatment for stress relief is not required for the construction of the MPC, the canister is susceptible to stress corrosion cracking in the weld or heat affected zone regions under long-term storage conditions. Logic for flaw acceptance is developed should crack-like flaws be detected by Inservice Inspection. The procedure recommended by API 579-1/ASME FFS-1, Fitness-for-Service, is used to calculate the instability crack length or depth by failure assessment diagram. It is demonstrated that the welding residual stress has a strong influence on the results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demonstrating solarpilot ’s Python Application Programmable Interface Through Heliostat Optimal Aimpoint Strategy Use Case

solarpilot is a software package that generates solar field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. solarpilot was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL’s System Advisor Model (SAM) in a simplified format. Prior means for user interaction with solarpilot have included the application’s graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called “LK.” This article presents a new, full-featured, python-based application programmable interface (API) for solarpilot, which we hereafter refer to as CoPylot. CoPylot enables python users to perform detailed CSP tower analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. CoPylot’s enables CSP researchers to perform analysis that was previously not possible through solarpilot’s existing interfaces. This article discusses the capabilities of CoPylot and presents a use case wherein we populate a model that obtains optimal solar field aiming strategies.

14 SOLAR ENERGY↗

Detailed Design and Cost Estimation of a 300 MWe Oxy-Fuel sCO2 Turbine

The detailed design of a 300 MWe, utility scale oxy-fuel turbine has been completed for purposed operation in the sCO2 direct fired Allam-Fetvedt cycle, targeting near-zero emissions and a 50% LHV system efficiency. The turbine and its supporting plant aim to offer a lower levelized cost of energy than a natural gas combined cycle plant employing carbon capture. The oxy-fuel turbine conditions include an inlet temperature of 1150°C and inlet pressure of 305 bar, representing temperatures near that of a gas turbine simultaneously with pressures near an ultra-supercritical steam turbine. The combustor housing and turbine designs were completed according to the ASME BPVC; the turbine case specifically incorporates a multi-body design with inner high-pressure barrel case and low-pressure (30 bar) horizontally split outer case of low-chromium steel material. Lateral rotordynamic evaluation demonstrated acceptable vibration response for a range of imbalance conditions per API standards. The cooling flow required in the six-stage turbine flowpath for 30,000 hr. blade and stator lifetime is predicted through thermal and structural modeling of the first stage. The provided cost estimate of the turbine is formed through a combination of scaled up-costs from procured 10 MWe scale sCO2 turbomachinery hardware, and vendor provided budgetary quotes of larger components including the turbine case requiring casting, welding, and final machining processes. The performance and cost estimation of the oxy-fuel turbine predicted for the completed detailed design provides important information towards future development needs for market penetration of utility scale direct fired sCO2 power cycles.

Marshall, Michael [Southwest Research Institute, S↗

SU-E-I-97: Smart Auto-Planning Framework in An EMR Environment (SAFEE)

Purpose: Our Radiation Oncology Department uses clinical practice guidelines for patient treatment, including normal tissue sparing and other dosimetric constraints. These practice guidelines were adapted from national guidelines, clinical trials, literature reviews, and practitioner's own experience. Modern treatment planning systems (TPS) have the capability of incorporating these practice guidelines to automatically create radiation therapy treatment plans with little human intervention. We are developing a software infrastructure to integrate clinical practice guidelines and radiation oncology electronic medical record (EMR) system into radiation therapy treatment planning system (TPS) for auto planning. Methods: Our Smart Auto-Planning Framework in an EMR environment (SAFEE) uses a software pipeline framework to integrate practice guidelines,EMR, and TPS together. The SAFEE system starts with retrieving diagnosis information and physician's prescription from the EMR system. After approval of contouring, SAFEE will automatically create plans according to our guidelines. Based on clinical objectives, SAFEE will automatically select treatment delivery techniques (such as, 3DRT/IMRT/VMAT) and optimize plans. When necessary, SAFEE will create multiple treatment plans with different combinations of parameters. SAFEE's pipeline structure makes it very flexible to integrate various techniques, such as, Model-Base Segmentation (MBS) and plan optimization algorithms, e.g., Multi-Criteria Optimization (MCO). In addition, SAFEE uses machine learning, data mining techniques, and an integrated database to create clinical knowledgebase and then answer clinical questions, such as, how to score plan quality or how volume overlap affects physicians' decision in beam and treatment technique selection. Results: In our institution, we use Varian Aria EMR system and RayStation TPS from RaySearch, whose ScriptService API allows control by external programs. These applications are the building blocks of our SAFEE system. Conclusion: SAFEE is a feasible method of integrating clinical information to develop an auto-planning paradigm to improve clinical workflow in cancer patient care.

60 APPLIED LIFE SCIENCES↗

SU-F-BRE-10: Methods to Simulate and Measure the Attenuation for Modeling a Couch Top with Rails for FFF Treatment Delivery On the Varian Edge Linac

Purpose: To measure attenuation for modelling of the KVue Couchtop for 6X and 10X FFF SRS/SBRT treatment Methods: Treatment planning simulation studies were done using 6X FFF beams to estimate the dosimetric impact of KVue couchtops (including the Q-Fix IGRT [carbon fiber] and Calypso [nonconductive Kevlar material]) with a structure model obtained from a research workstation (Eclipse, advanced planning interface (API) v13). Prior to installation on the Varian Edge linac, the couchtop along with (Kevlar) rails were CT scanned with the rails at various positions. An additional scan with the couchtop 15cm above the CT table top was obtained with 20cm solid water to facilitate precised/indexed data acquisition. Measurements for attenuation were obtained for field sizes of 2, 4 and 10 cm{sup 2} at 42 gantry angles including 6 pairs of opposing fields and other angles for oblique delivery where the beams traversed the couchtop and or rails. The delivery was fully automated with xml scripts running in developer mode. The results were then used to determine an accurate structure model for AAA (Eclipse v11) planning of IMRT and RapidArc delivery. Results: The planning simulation relative dose attenuation for oblique entry was not significantly different than the Exact IGRT or BrainLab iBeam couch except that the rails added 6% additional attenuation. The relative attenuation measurements for PA, PA (rails: inner position), oblique, oblique (rails: outer position), oblique (rails: inner position) were: −2.0%, −2.5%, −15.6%, −2.5%, −5.0% for 6X FFF and −1.4%, −1.5%, −12.2%, − 2.5%, −5.0% for 10X FFF with slight decrease in attenuation versus field size. A Couch structure model (with HU values) was developed. Calculation compared to measurement showed good agreement except for oblique (rails: outer position) where differences approached a magnitude of 6%. Conclusion: A model of the couch structures has been developed accounting for attenuation for FFF beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827.

60 APPLIED LIFE SCIENCES↗

SU-E-T-138: Automated Chart Review Module Including Cross-Vendor Data Transfer Verification Developed for IHE-RO Initiative

Purpose: To follow the Integrating Healthcare Enterprise - Radiation Oncology (IHE-RO) initiative of proper cross-vendor technology integration, an automated chart checker (ACC) was developed. ACC compares extracted data from an approved patient plan in the Eclipse treatment planning system (TPS) against data existing in the Mosaiq treatment management system (TMS). ACC automatically analyzes these parameters using built-in quality checklists to provide further aid in chart review. Methods: Eclipse TPS data are obtained using Eclipse scripting API (ESAPI) while Mosaiq TMS data are obtained from a radiotherapy-treatment-planning (RTP) file. Using this information, ACC identifies TPS-TMS discrepancies in 18 primary beam parameters including MU, energy, jaw positions, gantry angle, table angle, accessories, and bolus for up to 31 beams. Next, approximately 40 items from traditional quality checklists are evaluated such as prescription consistency, DRR graticule placement, plan approval status, global max dose, and dose tracking coefficients. Parameters were artificially modified to determine if ACC would detect an error in data transfer and to test each component of quality checklists. Results: Using ESAPI scripting and RTP file-processing, ACC was able to properly aggregate data from TPS and TMS for up to 31 beams. Errors were artificially introduced into each plan parameter, and ACC was able to successfully detect all of them within seconds. Next, ACC was able to successfully detect mistakes in the chart by identifying deviations with its quality checklists, within seconds. Conclusion: ACC effectively addresses the potential issue of faulty cross-vendor data transfer, as described by IHE-RO. In addition, ACC was also able to detect deviations from its built-in quality checklists. ACC is already an invaluable tool for efficient and standardized chart review and will continue to improve as its incorporated checklists become more comprehensive.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-T-01: Radiosurgery of Multiple Brain Metastases with Single-Isocenter VMAT: Optimizing Treatment Geometry to Reduce Normal Brain Dose

Purpose: To develop an optimization algorithm to reduce normal brain dose by optimizing couch and collimator angles for single isocenter multiple targets treatment of stereotactic radiosurgery. Methods: Three metastatic brain lesions were retrospectively planned using single-isocenter volumetric modulated arc therapy (VMAT). Three matrices were developed to calculate the projection of each lesion on Beam’s Eye View (BEV) by the rotating couch, collimator and gantry respectively. The island blocking problem was addressed by computing the total area of open space between any two lesions with shared MLC leaf pairs. The couch and collimator angles resulting in the smallest open areas were the optimized angles for each treatment arc. Two treatment plans with and without couch and collimator angle optimization were developed using the same objective functions and to achieve 99% of each target volume receiving full prescription dose of 18Gy. Plan quality was evaluated by calculating each target’s Conformity Index (CI), Gradient Index (GI), and Homogeneity index (HI), and absolute volume of normal brain V8Gy, V10Gy, V12Gy, and V14Gy. Results: Using the new couch/collimator optimization strategy, dose to normal brain tissue was reduced substantially. V8, V10, V12, and V14 decreased by 2.3%, 3.6%, 3.5%, and 6%, respectively. There were no significant differences in the conformity index, gradient index, and homogeneity index between two treatment plans with and without the new optimization algorithm. Conclusion: We have developed a solution to the island blocking problem in delivering radiation to multiple brain metastases with shared isocenter. Significant reduction in dose to normal brain was achieved by using optimal couch and collimator angles that minimize total area of open space between any of the two lesions with shared MLC leaf pairs. This technique has been integrated into Eclipse treatment system using scripting API.

60 APPLIED LIFE SCIENCES↗

SU-F-T-101: Insight into Dosimetry Workload and Planning Timelines: A 6 Year Review at One Institution

Purpose: To elucidate realistic clinical treatment planning workload and timelines to improve understanding for patients, payers, and other institutions involved in radiotherapy processes. Methods: A web based tool was developed using Oracle Express (Oracle Corp, Redwood City, CA) which allowed communication between the physicians and staff about the current state of the patient plan. For 6 years, all patient courses were logged and time-stamped in 22 discreet steps which detailed start and stop times for simulation, contouring, and treatment planning tasks. This data was combined with the treatment planning database (TPDB) using the Eclipse Scripting API (Varian Medical Systems, Palo Alto, CA) to cross-identify plans between the two systems. This time data was analyzed across our dosimetry staff and treatment modality. Results: In 6 years, 110,477 patient statuses were time-logged for 9683 courses of treatment using our internal software. The courses contained 8305 unique patients who were binned into one of 11 diagnosis site categories. 8253 courses could be reconciled against the TPDB using timestamp data from patient statuses. The average planning volume per dosimetrist was 375.8 ± 142.4 plans per year with the average number of planning revisions per dosimetrist of 71.0 ± 27.1 plans per year. The median treatment planning times by modality ranged from to 48.3 hours for IMRT plans 5 fields or less to 119.6 hours for IMRT with 8 or more fields. Two arc VMAT, three arc VMAT, and 3D plans median times were 89.1 hours, 113.8 hours, and 50.9 hours respectively. Conclusion: Using our web based tool, we have demonstrated the ability to quantify treatment planning timelines and workloads which could help in setting appropriate expectations for patients, payers, and hospital administration. COI: Author received monies from Varian Medical Systems for research and teaching honorarium.

60 APPLIED LIFE SCIENCES↗

SU-F-T-531: Determination of Site-Specific Dynamic-Jaw Versus Static-Jaw RapidArc Delivery

Purpose: Dynamic-jaw tracking maximizes the area blocked by both jaw and MLC in RapidArc. We developed a method to quantify jaw tracking. Methods: An Eclipse Scripting API (ESAPI) was used to export beam parameters for each arc’s control points. The specific beam parameters extracted were: gantry angle, control point number, meterset, x-jaw positions, y-jaw positions, MLC bank-number, MLC leaf-number, and MLC leaf-position. Each arc contained 178 control points with 120 MLC positions. MATLAB routines were written to process these parameters in order to calculate both the beam aperture (unblocked) size for each control point. An average aperture size was weighted by meterset. Jaw factor was defined as the ratio between dynamic-jaw to static-jaw aperture size. Jaw factor was determined for forty retrospectively replanned patients treated with static-jaw delivery sites including lung, brain, prostate, H&N, rectum, and bladder. Results: Most patients had multiple arcs and reduced-field boosts, resulting in 151 fields. Of these, the lowest (0.4722) and highest (0.9622) jaw factor was observed in prostate and rectal cases, respectively. The median jaw factor was 0.7917 meaning there is the potential unincreased blocking by 20%. Clinically, the dynamic-jaw tracking represents an area surrounding the target which would receive MLC-only leakage transmission of 1.68% versus 0.1% with jaws. Jaw-tracking was more pronounced at areas farther from the target. In prostate patients, the rectum and bladder had 5.5% and 6.3% lower mean dose, respectively; the structures closer to the prostate such as the rectum and bladder both had 1.4% lower mean dose. Conclusion: A custom ESAPI script was coupled with a MATLAB routine in order to extract beam parameters from static-jaw plans and their replanned dynamic-jaw deliveries. The effects were quantified using jaw factor which is the ratio between the meterset weighted aperture size for dynamic-jaw fields versus static-jaw fields.

60 APPLIED LIFE SCIENCES↗

TH-D-BRB-04: Pinnacle Scripting: Improving Efficiency While Maintaining Safety

Scripting capabilities and application programming interfaces (APIs) are becoming commonly available in modern treatment planning systems. These links to the treatment planning system (TPS) allow users to read data from the TPS, and in some cases use TPS functionality and write data back to the TPS. Such tools are powerful extensions, allowing automation of routine clinical tasks and supporting research, particularly research involving repetitive tasks on large patient populations. The data and functionality exposed by scripting/API capabilities is vendor dependent, as are the languages used by script/API engines, such as the Microsoft .NET framework or Python. Scripts deployed in a clinical environment must be commissioned and validated like any other software tool. This session will provide an overview of scripting applications and a discussion of best practices, followed by a practical introduction to the scripting capabilities of three commercial treatment planning systems. Learning Objectives: Understand the scripting capabilities available in several treatment planning systems Learn how to get started using scripting capabilities Understand the best practices for safe script deployment in a clinical environment R. Popple, Varian Medical Systems has provided research support unrelated to the topic of this session.R. Cardan, Varian Medical Systems for grant research, product evaluation, and teaching honorarium.

60 APPLIED LIFE SCIENCES↗

Performance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation

We investigate the performance of Opticks, a NVIDIA OptiX API 7.5 GPU-accelerated photon propagation tool compared with a single-threaded Geant4 simulation. We compare the simulations using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Performance results suggest that Opticks improves simulation speeds by between 58.47 ± 0.02 and 181.39 ± 0.28 times relative to a CPU-only Geant4 simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between Opticks and Geant4.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Building a Secure and Feature-rich Mobile Mapping Service App Using HTML5: Challenges and Best Practices

Managing a wide variety of mobile devices across multiple mobile operating systems is a security challenge for any organization [1, 2]. With the wide adoption of mobile devices to access work-related apps, there is an increase in third-party apps that might either misuse or improperly handle user s personal or sensitive data [3]. HTML5 has been receiving wide attention for developing cross-platform mobile apps. According to International Data Corporation (IDC), by 2015, 80% of all mobile apps will be based in part or wholly upon HTML5 [4]. Though HTML5 provides a rich set of features for building an app, it is a challenge for organizations to deploy and manage HTML5 apps on wide variety of devices while keeping security policies intact. In this paper, we will describe an upcoming secure mobile environment for HTML5 apps, called Sencha Space that addresses these issues and discuss how it will be used to design and build a secure and cross-platform mobile mapping service app. We will also describe how HTML5 and a new set of related technologies such as Geolocation API, WebGL, Open Layers 3, and Local Storage, can be used to provide a high end and high performance experience for users of the mapping service app.

Karthik, Rajasekar↗

StreamJIT: a commensal compiler for high-performance stream programming

There are many domain libraries, but despite the performance benefits of compilation, domain-specific languages are comparatively rare due to the high cost of implementing an optimizing compiler. We propose commensal compilation, a new strategy for compiling embedded domain-specific languages by reusing the massive investment in modern language virtual machine platforms. Commensal compilers use the host language's front-end, use host platform APIs that enable back-end optimizations by the host platform JIT, and use an autotuner for optimization selection. The cost of implementing a commensal compiler is only the cost of implementing the domain-specific optimizations. We demonstrate the concept by implementing a commensal compiler for the stream programming language StreamJIT atop the Java platform. Our compiler achieves performance 2.8 times better than the StreamIt native code (via GCC) compiler with considerably less implementation effort.

97 MATHEMATICS AND COMPUTING↗

UNITY: Unified Memory and File Space. In: ROSS '17 Proceedings of the 7th International Workshop on Runtime and Operating Systems for Supercomputers ROSS 2017, Article No. 6

This paper describes the vision for UNITY, a new high-performance computing focused data storage abstraction that places the entire memory hierarchy, including both traditionally separated memory-and file-based data storage, into one storage continuum. Through the use of a novel API and a set of services centered around a smart runtime system, UNITY is able to provide a number of valuable and interesting benefits. The unified storage space provides a scalable and resilient data environment that dynamically manages the mapping of data onto available resources based on multiple factors, including desired persistence and energy budget considerations. By eliminating the need for high-performance computing domain scientists to develop architecture-dependent optimizations for rapidly evolving data storage technologies, UNITY addresses both ease-of-use and performance.

Jones, Terry↗

Caspian: A Neuromorphic Development Platform

Current neuromorphic systems often may be difficult to use and costly to deploy. There exists a need for a simple yet flexible neuromorphic development platform which can allow researchers to quickly prototype ideas and applications. Caspian offers a high-level API along with a fast spiking simulator to enable the rapid development of neuromorphic solutions. It further offers an FPGA architecture that allows for simplified deployment -- particularly in SWaP (size, weight, and power) constrained environments. Leveraging both software and hardware, Caspian aims to accelerate development and deployment while enabling new researchers to quickly become productive with a spiking neural network system.

Mitchell, Parker↗

A Backend-agnostic, Quantum-classical Framework for Simulations of Chemistry in C ++

As quantum computing hardware systems continue to advance, the research and development of performant, scalable, and extensible software architectures, languages, models, and compilers is equally as important to bring this novel coprocessing capability to a diverse group of domain computational scientists. For the field of quantum chemistry, applications and frameworks exist for modeling and simulation tasks that scale on heterogeneous classical architectures, and we envision the need for similar frameworks on heterogeneous quantum-classical platforms. Furthermore, we present the XACC system-level quantum computing framework as a platform for prototyping, developing, and deploying quantum-classical software that specifically targets chemistry applications. We review the fundamental design features in XACC, with special attention to its extensibility and modularity for key quantum programming workflow interfaces and provide an overview of the interfaces most relevant to simulations of chemistry. A series of examples demonstrating some of the state-of-the-art chemistry algorithms currently implemented in XACC are presented, while also illustrating the various APIs that would enable the community to extend, modify, and devise new algorithms and applications in the realm of chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗