Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Linear Systems LSK389 and LSK489 Dual N-Channel JFET Amplifier Total Ionizing Dose and Single-Event Effects Test Report

The purpose of these tests was to characterize the susceptibility of the LSK389 and LSK489 Dual N-Channel JFET from Linear Systems to Single-Event Latchup due to heavy ions and to Total Ionizing Dose (TID) degradation at -65 °C and intermediate dose rate. The test was carried out to assess suitability of the amplifiers for the Ocean Color instrument (OCI) on the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft.

Ray Ladbury↗

A Dedicated, Long Duration Balloon Mission from Antarctica to Measure the Effects of Low Dose Galactic Cosmic Radiation on Biology

Antarctic long duration balloon missions flown by NASA’s Science Mission Directorate (SMD)can be used as a surrogate for the deep space radiation environment, reducing the need to launch orbital experiments to assess the impact of galactic cosmic radiation (GCR) on biology. To date, over fifty NASA balloon missions flown from Antarctica have carried scientific payloads from Astrophysics (APD) and Heliophysics (HPD)in SMD. Only two life science experiments have been flown from Antarctica, and both were ride-along (piggyback) opportunities, limiting the sophistication and types of model organisms that can be incorporated into studies. Herein, we argue for establishing a large, dedicated Antarctic balloon mission for the Biological and Physical Sciences (BPS) Division in SMD to be launched in 2029/2030, with an “omnibus” gondola carrying dozens of independent Space Biology payloads that would receive a sustained exposure to low dose rate GCRs for 30+ days. Our unprecedented, protracted radiation experiment cannot be done using ground-based simulation facilities or in space; it can only be achieved through an Antarctic balloon mission dedicated to BPS Division payloads. By providing more access to radiation research platforms through existing NASA SMD access to Antarctic balloon flight opportunities, the Space Biology community will be better positioned to address unknowns associated with low dose rate GCR exposures in long duration spaceflight.

David J Smith↗

Oxidative Stress and Neuroconsequences of the Spaceflight Environment –A 5-ion GCRsim Dose-response Study

The overall scope of this project is to test the hypothesis that Ionizing Radiation (IR), microgravity and social isolation combine synergistically to trigger an oxidative stress response that alters immune homeostasis, brain structure/function, and neurobehavioral/cognitive performance. Specific Aims for this project are to: (1) Determine dose-response curves for acute ‘Five-Ion GCR Simulation’ exposure for immune, brain and performance responses in crew age-matched adult male and female mice; (2) Determine effects of acute ‘Five-Ion GCR Simulation’ exposure singly and in combination with simulated microgravity and social isolation, on immune, brain and performance responses in crew age-matched male and female mice mimicking deep space missions; and (3) Determine efficacy of the dietary antioxidant, Nicotinamide Mononucleotide (NMN), a key intermediate in nicotinamide adenine dinucleotide (NAD+) biosynthesis. Here we exposed mature (23-24-week-old) male and female mice to simulated 5-Ion GCR (either 0, 5, 15, or 50cGy) at the NASA Space Radiation Laboratory (NSRL). Across ‘Acute’ (IR+72hrs and IR+14 days) and ‘Delayed’ (IR+28 to IR+124 days) phases of the 6-month-long study, we assessed immune, neural, and functional (sensorimotor/behavioral/cognitive) responses anticipated during a transit to Mars. This presentation will report on dose-response curves for 5-ion GCRsim related to potential biomarkers; structural/functional changes in the immune and nervous systems; and behavioral/cognitive performance deficits. This project addresses NASA’s efforts to characterize risks and identify appropriate countermeasures in anticipation of future deep space missions. Ensuring crew health and performance during extended transits necessitates that sensorimotor and cognitive abilities remain strong to avoid potentially catastrophic health and safety outcomes.

deep space↗

Neuro-behavioral Consequences of Low Dose Radiation Social Isolation and Sex Differences in the Longevity MCAT Mouse Model

The physiological responses to spaceflight elicit wide-ranging consequences and resemble aspects of aging on Earth. Previous studies have shown that oxidative damage via reactive oxygen species (ROS), contributes to aging-related pathologies. Our study uses 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation together with social isolation and were euthanized 12 weeks after. We used the longevity MCAT mouse model in which human catalase is overexpressed in the mitochondria, for ROS quenching. We aimed to determine whether in older mice quenching ROS, will mitigate the neuro-behavioral consequences of low dose ionizing radiation and/or social isolation and whether the outcomes will differ in males and females. We have performed five mission relevant behavioral tests which focused on performance, memory, physical stance, and stress. We have detected both sex and radiation effects; the older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was indeed mitigated in the MCAT mice, pointing out to the importance of ROS in response to radiation stress and social isolation. We have measured plasma (7- and 90-days post radiation), cytokines, corticosterone and hippocampal cytokine and microglial activation at the end of the experiment. We saw significant changes in the plasma markers due to radiation, sex, and genotype in both short and long post radiation period and detected long term sex and radiation effects in the brain. Our focus is now on applying advanced statistical modeling to corelate the behavioral tests with our recent molecular findings to look for specific biomarkers that could predict behavioral deficits.

radiation↗

Shields-1 Energetic Proton Dose Comparison from Solar Minimum and Active Periods

Shields-1 has been operating in polar low earth orbit since December 2018 as part of the CubeSat Launch Initiative (CSLI) Educational Launch of Nanosatellites (ELaNa)XIX Mission. Shields-1 has 8 Teledyne µdosimeters behind shielding. These shielded µdosimeters have high minimum proton energy thresholds. The Shields-1 electronics enclosure µdosimeter has a minimum proton threshold energy of 151 MeV. The annualized total ionizing dose (TID) in the electronics enclosure was 75.6 +/- 3.2 RAD from July-August 2019, which was a solar minimum period. In contrast, the annualized TID was 61.0 +/- 2.5 RAD in July 2023, a solar active month. The TID change can be attributed to both the reduction in radiation at the South Atlantic Anomaly (SAA) and the decrease in galactic cosmic radiation during increasing solar activity. The measured GCR dose over the poles was reduced during the July 2023 solar active period in comparison with the July 2019 solar minimum period, using the most sensitive µdosimeter channel for the measurement. Shields-1 has demonstrated the capability of measuring the changes in high energy protons in polar low earth orbit during changes in solar activity, which contributes to the understanding of Earth in the heliosphere.

Shields-1 Dosimetry Space Sciences↗

Doses and fluxes in the proton-irradiated Big Target: A MARS15 analysis

This work is aimed at determination of secondary particle fluxes, prompt and residual doses as well as energy deposition in and around the Big Target, a 20-tonnes cylindrical target made of natural uranium with the lead core and a stainless-steel yoke, which is being considered to be irradiated by a 0.16-μA 600-MeV proton beam of the JINR Phasotron accelerator. The simulations were performed with the use of the MARS15 particle transport code employing the LAQGSM and CEM generators and based on the ENDFB-VIII neutron cross section library. The calculations for 12-hour, 100-hour, and 3-day irradiations with the aforementioned conditions indicate that temperature rise due to the beam does not require target cooling, the target can be safely handled soon after the end of irradiation, and its decommissioning is possible three years past the irradiation. Doses

43 PARTICLE ACCELERATORS↗

Comparison of Measured and Calculated Dose Rates for Ring Injection Dump Exchange at Spallation Neutron Source

According to the accelerator operation plan, the beam-stop and the proton beam window (PBW) assemblies of the existing Ring Injection Dump RID are replaced with fresh assemblies, when they have reached their end-of-life. End of-life is determinate by the stainless-steel beam-stop window having accumulated 10 dpa radiation damage. The exchange process took place during facility maintenance period that started in March 2023. Each of the spent assembles were put into specially designed storage containers temporarily residing near the RID building.The spent beam-stop is predicted to be the part of highest activation that has been removed in Spallation Neutron Source (SNS). The exchange processes require good work planning to minimize radiation exposure to personal. For each exchange step the residual dose rate distribution is calculated and the peak values are identified. This paper gives some examples of calculated vs measured doses during beam-stop assembly exchange.

Popova, Irina I.↗

Residual Dose Rates Analyses from Vent Lines Shield Block on the Target Cart at Spallation Neutron Source

The target carriage supports the mercury target vessel in the Spallation Neutron Source (SNS) in a cantilevered fashion and supplies the liquid mercury flowing to and from the target vessel. The target carriage is designed to move the target vessel into its target monolith position to receive the proton beam and then remove it horizontally back into an adjacent service cell, where the target vessel can be exchanged about 2-3 times per calendar year. At the time of the performed studies, the SNS mercury target can accept a proton beam at 1 GeV energy and 1.4 MW power; however, it will be upgraded to receive 1.3 GeV energy at 2 MW by the end of 2024 year [1]. The cart is practically a shield block on wheels to minimize fluxes and dose rates in the service cell downstream of the carriage. There are vent lines located inside a passage on top of the target carriage, and they are covered by a stepping-up steel shield block (vent lines shield block). Vent lines are permanently attached to the shield block. New vent lines with a different design are going to be installed. These lines are shielded by the new steel block to which the vent lines are attached. The estimate of the residual dose rates from the block after it is extracted from the target carriage is performed to estimate the radiation fields and to decide on the type of storage container to be used.

Popova, Irina I↗

In-situ ion irradiation of a spent UO2 fuel: evolution of fission products and nanograins with radiation dose

This study investigates the behavior of fission gas bubbles, five metal precipitates (5MPs) (Mo, Ru, Rh, Tc, Pd) and nanograins in spent uranium dioxide (UO2) fuel under various ion irradiation doses, temperatures, and flux conditions. Utilizing in-situ ion irradiation and advanced transmission electron microscopy, we analyzed the evolution of fission gas bubbles, 5MPs and nanograins in UO2 samples from the Belgium Reactor 3 (BR-3). Our findings reveal significant shrinkage of fission gas bubbles and 5MPs with increasing irradiation dose, accompanied by a decrease in pair density. The study also reveals nanograin coarsening under irradiation. We demonstrate that ion irradiation induces a homogeneous re-solution process where individual atoms are ejected from bubbles and precipitates, leading to their dissolution and subsequent re-precipitation in the matrix. This study provides critical insights into the dynamic behavior of fission products and nanograins under irradiation, facilitating the development of predictive models and contributing to the optimization of nuclear fuel performance and safety.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gantry-Based 5-Fraction Elective Nodal Irradiation in Unfavorable-Risk Prostate Cancer: Outcomes From 2 Prospective Studies Comparing SABR Boost With MR Dose-Painted HDR Brachytherapy Boost

Guidelines from the American Society of Clinical Oncology and Cancer Care Ontario recommend brachytherapy boost for patients with intermediate-risk or high-risk prostate cancer. SABR is an emerging technique for prostate cancer, but its use in high-risk disease is limited. Efficacy, toxic effects, and quality of life (QoL) were compared in patients treated on 2 prospective protocols that used SABR boost or magnetic resonance–guided high-dose-rate brachytherapy (HDR-BT) boost with 6 to 18 months of androgen deprivation therapy (ADT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inclusion of Radiation Environment Variability in Total Dose Hardness Assurance Methodology

Variability of the space radiation environment is investigated with regard to parts categorization for total dose hardness assurance methods. It is shown that it can have a significant impact. A modified approach is developed that uses current environment models more consistently and replaces the design margin concept with one of failure probability.

radiation hardness assurance↗

HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report

The purpose of this test was to validate the Intersil HSYE-117RH-Q flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for the flight lot date with wafer lot number G3X3CQC and lot date code (LDC) 1830. Low dose rate (LDR) irradiations have been performed by the manufacturer, but only to 100 krad(Si). This test was a follow-on to the original Radiation Lot-Specific Acceptance Testing (RLAT) performed on this LDC. Application-specific load currents were used for the line regulation and load regulation measurements. All other parameters were measured with standard bias conditions as specified in the datasheet.

Total Ionizing Dose (TID)↗

Canister valve and actuator deposition in metered dose inhalers formulated with low-GWP propellants

A challenge in pressurised metered-dose inhaler (pMDI) formulation design is management of adhesion of the drug to the canister wall, valve and actuator internal components and surfaces. Wall-material interactions differ between transparent vials used for visual inspection and metal canister pMDI systems. This is of particular concern for low greenhouse warming potential (GWP) formulations where propellant chemistry and solubility with many drugs are not well understood. In this study, we demonstrate a novel application of X-ray fluorescence spectroscopy using synchrotron radiation to assay the contents of surrogate solution and suspension pMDI formulations of potassium iodide and barium sulphate in propellants HFA134a, HFA152a and HFO1234ze(E) using aluminium canisters and standard components. Preliminary results indicate that through unit life drug distribution in the canister valve closure region and actuator can vary significantly with new propellants. For solution formulations HFO1234ze(E) propellant shows the greatest increase in local deposition inside the canister valve closure region as compared to HFA134a and HFA152a, with correspondingly reduced actuator deposition. This is likely driven by chemistry changes. For suspension formulations HFA152a shows the greatest differences, due to its low specific gravity. These changes must be taken into consideration in the development of products utilising low-GWP propellants.

60 APPLIED LIFE SCIENCES↗

A Phase 1 Dose Escalation Study of Neoadjuvant SBRT Plus Elective Nodal Radiation with Concurrent Capecitabine for Resectable Pancreatic Cancer

The role of neoadjuvant radiation for resectable pancreatic adenocarcinoma is controversial. We performed a prospective dose-escalation study of neoadjuvant stereotactic body radiation therapy (SBRT) with concurrent capecitabine and elective nodal irradiation (ENI) followed by surgical resection to explore the toxicity and feasibility of this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pneumonia After Bacterial or Viral Infection Preceded or Followed by Radiation Exposure: A Reanalysis of Older Radiobiologic Data and Implications for Low-Dose Radiation Therapy for Coronavirus Disease 2019 Pneumonia

Currently, there are about 15 ongoing clinical studies on low dose radiation therapy for Coronavirus Disease 2019 pneumonia. One of the underlying assumptions is that irradiation of 0.5 to 1.5 Gy is effective at ameliorating viral pneumonia. We aimed to reanalyze all available experimental radiobiologic data to assess evidence for such amelioration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗