Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

A class of optimum digital phase locked loops for the DSN advanced receiver

A class of optimum digital filters for digital phase locked loop of the deep space network advanced receiver is discussed. The filter minimizes a weighted combination of the variance of the random component of the phase error and the sum square of the deterministic dynamic component of phase error at the output of the numerically controlled oscillator (NCO). By varying the weighting coefficient over a suitable range of values, a wide set of filters are obtained such that, for any specified value of the equivalent loop-noise bandwidth, there corresponds a unique filter in this class. This filter thus has the property of having the best transient response over all possible filters of the same bandwidth and type. The optimum filters are also evaluated in terms of their gain margin for stability and their steady-state error performance.

Hurd, W. J.↗

X-ray imaging of flare loops and coronal arches

HXIS (Hard X-ray Imaging Spectrometer) results related to preflare, flare-decay, and post-flare phases in the solar corona are summarized. Particularly discussed are miniflares, long-lived X-ray enhancements along filament channels, flare precursors (some signifying the flare position, others possibly related to the onset of mass ejections), growth of post-flare loops, images of sites of field-line reconnections late in the flare development, giant post-flare coronal arches with energy contents comparable to coronal transients, and hot loops interconnecting active regions. The extremely low HXIS background, in particular, made it possible to discover many new, previously unknown features in the solar corona. Also emphasized are some problems that have appeared during the evaluation of HXIS data, for the benefit of those who plan future hard X-ray imaging experiments.

Svestka, Z.↗

The Capillary Pumped Loop (CPL) GAS experiment G-471

The Capillary Pumped Loop (CPL) experiment, 6-471 is a thermal control system with high density heat acquisition and transport capability. The CPL consists of two capillary pumped evaporators with integral heaters, a fluid loop charged with ammonia (NH3), a condenser plate (heat sink), and various control electronics. The purpose of the experiment is to demonstrate the capability of a capillary pumped system under zero gravity conditions for use in the thermal control of large scientific instruments, advanced orbiting spacecraft, and space station components. A unique feature of the CPL is the capillary pumps, which contain no moving parts. Each pump contains a wick of porous material which is saturated with the working fluid (anhydrous ammonia). As heat is added to the fluid, it evaporates and travels to the condenser, thus transporting the heat (via the latent heat of vaporization) from the heat source to its sink at nearly a constant temperature. The evaporation process produces the pressure gradient or pumping action that circulates the fluid. This is the same principal that plants and trees use to transport water and nutrients from their roots to their leaves against gravity. The difference is that the CPL employs a closed system to return the fluid directly to the pumps, whereas "Mother Nature'' has an open system where the fluid is indirectly returned to the roots by condensation of water from the clouds in the form of rain. It should be noted that the CPL experiment was the first flight of a thermal control system of this type. It was also the first shuttle experiment from the Space Station Advanced Development Program.

Dan Butler↗

On the evaluation of expected performance cost for partially observed closed-loop stochastic systems

New methods are presented for evaluating the expected performance cost of partially observed closed-loop stochastic systems. When the variances of the process statistics are small, a linearized model of the closed-loop stochastic system is defined for which the expected cost can be evaluated by recursion on a set of purely deterministic difference equations. When the variances of the process statistics are large, the linearized model can be used in the control variate method of variance reduction for reducing the number of sample paths required for effective Monte Carlo estimation.

Bayard, D. S.↗

Energy release topology in a multiple-loop solar flare

The temporal and spatial structures of the UV and X-ray emissions and the magnetic field configuration in the November 12, 1980 flare observed from SMM have been studied. The UV observations were done in the O V and Fe XXI lines with a spatial resolution of 10 arcsec. The observations show that the impulsive UV bursts, and also the hard X-ray bursts by their temporal correlation with the impulsive O V emission, occurred in small localized kernels. By comparing the O V, Fe XXI, and X-ray raster images of the flare with the magnetogram, these emission kernels were identified as footpoints of interacting magnetic flux loops. The temporal evolution of the O V/Fe XXI emission shows that there was considerable preheating in the flare plasma some 8-9 minutes prior to the onset of the main hard X-ray bursts. The results are interpreted as indicating that the primary flare energy release occurred in a highly sheared multiloop structure, which lies along a magnetic neutral line. By either beam particle propagation or convective motion, flare energy is transported via a common footpoint to another loop which brightened later. The preheating of the flare plasma is shown to create a more favorable environment for energetic particle acceleration which resulted in the main impulsive hard X-ray bursts.

Cheng, C.-C.↗

The Cygnus loop - A detailed comparison of X-ray and optical emission

A comparison at a resolution of 17 arcsec is presented between optical emission from forbidden O III and forbidden S II and the thermal X-ray emission for a field on the southeast edge of the Cygnus Loop SNR. The relationship between optical and X-ray emission in the field is described, generalizing to the Loop as a whole when possible. Several possible explanations for the presence of bright X-ray emission in the vicinity of optical emission are presented and evaluated based on the data. These mechanisms involve evaporation, gradual variations and gradients in the density of the preshock intercloud medium, and additional compression of material which has already been heated to X-ray temperatures by the adiabatic blast wave. The additional compression could result from rapid deceleration of the blast wave itself or from reshocking by reflected or bow shocks around dense clouds. Implications of the observations for models of SNR evolution and the interstellar medium are discussed.

Cox, D. P.↗

Functional and performance tests of two capillary pumped loop engineering models

This paper presents the results of the functional and performance tests for two capillary pumped loop (CPL) engineering models. Both CPL systems are aluminum/ammonia transport systems which contain eight parallel evaporators and six parallel condensers in a single loop. Tests conducted include the transport limit, heat load shearing between evaporators, liquid inventory/temperature control by the reservoir, pressure priming under heat load, diode function of condensers, and isolation of a single deprimed evaporator. Consistent performance results were obtained for both systems. Transport capabilities of up to 70 kw-m with individual evaporators managing up to 1.7 kw, with a corresponding input heat flux of 15w/sq cm, were demonstrated. These tests demonstrated the ability of a CPL system to operate over a wide range of conditions and thus established the viability of these systems for high power thermal management of large spacecraft, such as the NASA Space Station.

Ku, J.↗

Capillary pumped loop GAS and Hitchhiker flight experiments

Flight experiments of a capillary pumped loop (CPL) aboard the Space Shuttle on both the Get Away Special (GAS) and Hitchhiker-G (H/H-G) carriers are described. These tests have shown that a two-phase heat transfer loop utilizing a wicking material as the system pumping mechanism can operate successfully in a zero-g environment. The CPL operating modes demonstrated were start-up, heat load sharing/natural priming, liquid inventory and temperature control via the reservoir, dryout recovery, and isolation of a single pump deprime. Also investigated were high and low power limits, and inlet subcooling requirements. In these CPL flight experiments, successful system operation was demonstrated at input power levels up to 560 watts and inlet subcooling below 2 C.

Ku, J.↗

Design of failure-accommodating multi-loop LQG regulators

This paper investigates the stability of multiloop LQ regulators when various combinations of actuator failures occur. It is proved that the closed-loop stability can be maintained under certain conditions by inserting appropriate constant gains in the control loops. The results are also applicable (via duality) to the design of state estimators which maintain stability in face of sensor failures.

Joshi, S. M.↗

Decimeter continuum radio emission from a post-flare loop

It is shown how radio observations permitted the estimation of magnetic fields in the postflare loop associated with the May 19, 1979 long-lasting burst. The strongest 20-cm burst source is associated with H-alpha brightening at 20:41 UT. A comparison of spatially-resolved microwave and soft X-ray emission connected with the flare loop event showed that, at the time of maximum 20-cm flux from the source associated spatially with the declining X-ray flare, as much as one-half of the 20-cm flux could be thermal bremsstrahlung from the X-ray postflare groups. It is suggested that this 20-cm burst emission is produced either by a thermal free-free process or by thermal/nonthermal gyroradiation.

Kundu, M. R.↗

Intercomparison of numerical models of flaring coronal loops

The proposed Benchmark Problem consists of an infinitesimal magnetic flux tube containing a low-beta plasma. The field strength is assumed to be so large that the plasma can move only along the flux tube, whose shape remains invariant with time (i.e., the fluid motion is essentially one-dimensional). The flux tube cross section is taken to be constant over its entire length. In planar view the flux tube has a semi-circular shape, symmetric about its midpoint s = s sub max and intersecting the chromosphere-corona interface (CCI) perpendicularly at each foot point. The arc length from the loop apex to the CCI is 10,000 km. The flux tube extends an additional 2000 km below the CCI to include the chromosphere, which initially has a uniform temperature of 8000 K. The temperature at the top of the loop was fixed initially at 2 X 1 million K. The plasma is assumed to be a perfect gas (gamma = 5/3), consisting of pure hydrogen which is considered to be fully ionized at all temperatures. For simplicity, moreover, the electron and ion temperatures are taken to be everywhere equal at all times (corresponding to an artificially enhanced electron-ion collisional coupling). While there was more-or-less unanimous agreement as to certain global properties of the system behavior (peak temperature reached, thermal-wave time scales, etc.), no two groups could claim satisfactory accord when a more detailed comparison of solutions was attempted.

Kopp, R. A.↗

Collisional heating by nonthermal electrons in a tapered magnetic loop

The behavior of nonthermal electrons ejected into a tapered magnetic loop, under the action of both Coulomb collisional and magnetic field gradient forces is studied. An approximate analytic formula for the heating rate as a function of distance along the loop is developed, and found to be in good agreement with exact numerical solutions of the relevant equations. Such a formula is useful as a source term in many situations, such as hydrodynamic simulations of atmospheric response to flare energy input.

Chandrashekar, S.↗

Space Station environmental control and life support system distribution and loop closure studies

The NASA Space Station's environmental control and life support system (ECLSS) encompasses functional elements concerned with temperature and humidity control, atmosphere control and supply, atmosphere revitalization, fire detection and suppression, water recovery and management, waste management, and EVA support. Attention is presently given to functional and physical module distributions of the ECLSS among these elements, with a view to resource requirements and safety implications. A strategy of physical distribution coupled with functional centralization is for the air revitalization and water reclamation systems. Also discussed is the degree of loop closure desirable in the initial operational capability status Space Station's oxygen and water reclamation loops.

Humphries, William R.↗

Dynamical behaviour in coronal loops

Rapid variability has been found in two active region coronal loops observed by the X-ray Polychromator (XRP) and the Hard X-ray Imaging Spectrometer (HXIS) onboard the Solar Maximum Mission (SMM). There appear to be surprisingly few observations of the short-time scale behavior of hot loops, and the evidence presented herein lends support to the hypothesis that coronal heating may be impulsive and driven by flaring.

Haisch, Bernhard M.↗

The relative contribution of beam versus thermally produced X-rays in the large loop of the 5 November 1980 flare

Observations of the temporal evolution of loop BC in soft X-rays in the November 5, 1980 flare are reviewed. Calculations are performed to model this evolution. The most consistent interpretation involving a minimum amount of energy is the following: thermal heating near B gives rise to a conduction front which moves out along the loop uninhibited for about 27 s, and beam heating near C gives rise to a second conduction front which moves in the opposite direction and prevents any energy reaching C by thermal conduction from B.

Smith, D. F.↗

Thermal test results of the two-phase thermal bus technology demonstration loop

A two-phase heat transport system, the Thermal Bus Technology Demonstrator, has been built and tested for NASA Johnson Space Center for application on Space Station. The loop is a separated two-phase system that uses evaporator flow control valves and liquid condenser flooding to achieve temperature control. Both ambient and thermal vacuum tests have been completed in NASA's Chamber A, initially using Freon-11 and then ammonia as the working fluid. Overall, the tests were quite successful, with the bus achieving all major test objectives, including operation at 19.5 kW and set points at 35 F (1.7 C), 70 F (21.1 C) and 104 F (40.0 C), load sharing, asymmetrical heating and isothermality around the loop. Low plate to vapor temperature drops were obtained for the monogroove cold plate using ammonia and are indicative of the high evaporative film coefficients obtainable with this design.

Edelstein, Fred↗

Designing Estimator/Predictor Digital Phase-Locked Loops

Signal delays in equipment compensated automatically. New approach to design of digital phase-locked loop (DPLL) incorporates concepts from estimation theory and involves decomposition of closed-loop transfer function into estimator and predictor. Estimator provides recursive estimates of phase, frequency, and higher order derivatives of phase with respect to time, while predictor compensates for delay, called "transport lag," caused by PLL equipment and by DPLL computations.

Statman, J. I.↗