Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Coherent diffractive imaging with twisted X-rays: Principles, applications, and outlook

Recent technological breakthroughs in synchrotron and x-ray free electron laser facilities have revolutionized nanoscale structural and dynamic analyses in condensed matter systems. This review provides a comprehensive overview of the advancements in coherent scattering and diffractive imaging techniques, which are now at the forefront of exploring materials science complexities. These techniques, notably Bragg coherent diffractive imaging and x-ray photon correlation spectroscopy, x-ray magnetic dichroism, and x-ray correlation analysis leverage beam coherence to achieve volumetric three-dimensional imaging at unprecedented sub-nanometer resolutions and explore dynamic phenomena within sub-millisecond timeframes. Such capabilities are critical in understanding and developing advanced materials and technologies. Simultaneously, the emergence of chiral crystals—characterized by their unique absence of standard inversion, mirror, or other roto-inversion symmetries—presents both challenges and opportunities. These materials exhibit distinctive interactions with light, leading to phenomena such as molecular optical activity, chiral photonic waveguides, and valley-specific light emissions, which are pivotal in the burgeoning fields of photonic and spintronic devices. This review elucidates how novel x-ray probes can be leveraged to unravel these properties and their implications for future technological applications. A significant focus of this review is the exploration of new avenues in research, particularly the shift from conventional methods to more innovative approaches in studying these chiral materials. Inspired by structured optical beams, the potential of coherent scattering techniques utilizing twisted x-ray beams is examined. This promising direction not only offers higher spatial resolution but also opens the door to previously unattainable insights in materials science. By contextualizing these advancements within the broader scientific landscape and highlighting their practical applications, this review aims to chart a course for future research in this rapidly evolving field.

Physics↗

High Angular Resolution ALMA Images of Dust and Molecules in the SN 1987A Ejecta

We present high angular resolution (∼80 mas) ALMA continuum images of the SN1987A system, together with CO J = 21, J = 65, and SiO J = 54 to J = 76 images, which clearly resolve the ejecta (dust continuum and molecules) and ring (synchrotron continuum) components. Dust in the ejecta is asymmetric and clumpy, and overall the dust fills the spatial void seen in Hα images, filling that region with material from heavier elements. The dust clumps generally fill the space where CO J = 6 5 is fainter, tentatively indicating that these dust clumps and CO are locationally and chemically linked. In these regions, carbonaceous dust grains might have formed after dissociation of CO. The dust grains would have cooled by radiation, and subsequent collisions of grains with gas would also cool the gas, suppressing the CO J = 6 5 intensity. The data show a dust peak spatially coincident with the molecular hole seen in previous ALMA CO J = 2 1 and SiO J = 5 4 images. That dust peak, combined with CO and SiO line spectra, suggests that the dust and gas could be at higher temperatures than the surrounding material, though higher density cannot be totally excluded. One of the possibilities is that a compact source provides additional heat at that location. Fits to the far-infrared–millimeter spectral energy distribution give ejecta dust temperatures of 18–23 K. We revise the ejecta dust mass to Mdust = 0.2–0.4 Mfor carbon or silicate grains, or a maximum of <0.7 Mfor a mixture of grain species, using the predicted nucleosynthesis yields as an upper limit.

Interstellar dust↗

Transition detection studies in the cryogenic environment

Boundary-layer transition detection studies were carried out in the 0.3 Meter Transonic Cryogenic Tunnel on a supercritical airfoil, using an infrared imaging system. The purpose of the experiments was to determine the extent of the temperature range in which commercially available IR systems can detect transition in cryogenic environment. The experiment was designed to take advantage of a combination of factors including the wind tunnel operation mode, the model construction materials and the IR system image processing options. During the initial phases of the study, the IR based findings were confirmed by measurements done with a micro-thin hot-film system. Ultimately, free and forced transition could be detected down to 170 K.

Gartenberg, Ehud↗

From ground to excited electronic state dynamics of electron and ion irradiated graphene nanomaterials

Microscopes utilizing convergent electron and ion beams are emerging as powerful tools for both imaging and manipulating two-dimensional materials with atomic resolution, allowing the ultimate limits of nanofabrication to be realized. In this chapter, we detail the use of time-dependent electronic structure theory to determine the excited state properties and reactivity of functionalized graphene nanostructures. A time-dependent density functional theory treatment of electronic excitations of materials is presented, with specific emphasis on predicting the position-dependent electronic response of two-dimensional nanomaterials to electron beams. The method is demonstrated in a study highlighting the important role that electronic excitation can play in opening reaction pathways relevant to atomically precise defect manipulation in graphene. Finally, we provide some perspective on future development directions for methods of simulating nonequilibrium electronic and vibrational dynamics induced by electron/ion beams.

Lingerfelt, David↗

Electrical Capacitance Volume Tomography with High-Contrast Dielectrics

The Electrical Capacitance Volume Tomography (ECVT) system has been designed to complement the tools created to sense the presence of water in nonconductive spacecraft materials, by helping to not only find the approximate location of moisture but also its quantity and depth. The ECVT system has been created for use with a new image reconstruction algorithm capable of imaging high-contrast dielectric distributions. Rather than relying solely on mutual capacitance readings as is done in traditional electrical capacitance tomography applications, this method reconstructs high-resolution images using only the self-capacitance measurements. The image reconstruction method assumes that the material under inspection consists of a binary dielectric distribution, with either a high relative dielectric value representing the water or a low dielectric value for the background material. By constraining the unknown dielectric material to one of two values, the inverse math problem that must be solved to generate the image is no longer ill-determined. The image resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. The cuboid geometry of the system has two parallel planes of 16 conductors arranged in a 4 4 pattern. The electrode geometry consists of parallel planes of copper conductors, connected through custom-built switch electronics, to a commercially available capacitance to digital converter. The figure shows two 4 4 arrays of electrodes milled from square sections of copper-clad circuit-board material and mounted on two pieces of glass-filled plastic backing, which were cut to approximately square shapes, 10 cm on a side. Each electrode is placed on 2.0-cm centers. The parallel arrays were mounted with the electrode arrays approximately 3 cm apart. The open ends were surrounded by a metal guard to reduce the sensitivity of the electrodes to outside interference and to help maintain the spacing between the arrays. Other uses for this innovation potentially include quantifying the amount of commodity remaining in the fuel and oxidizer tanks while on-orbit without having to fire spacecraft engines. Another orbit application is moisture sensing in plant-growth experiments because microgravity causes moisture in soil to distribute itself in unusual ways. At the moment, the hardware and image reconstruction technique may only be of interest to people involved in nondestructive evaluation. The reconstructed image takes almost a full week to reproduce with existing computer power. However, because computer power and speeds follows Moore s Law, execution times are likely to become acceptable within the next five to eight years. The code was written in Mathematica for dedicated use with the ECVT system. In its present form, it is not suitable to be used directly as a consumer product. However, the code could be likely improved by rewriting it in a compiled language such as C or Fortran.

Nurge, Mark↗

Multi-slice electron ptychographic tomography for three-dimensional phase-contrast microscopy beyond the depth of focus limits

Electron ptychography is a powerful computational method for atomic-resolution imaging with high contrast for weakly and strongly scattering elements. Modern algorithms coupled with fast and efficient detectors allow imaging specimens with tens of nanometers thicknesses with sub-0.5 Ångstrom lateral resolution. However, the axial resolution in these approaches is currently limited to a few nanometers, limiting their ability to solve novel atomic structures ab initio. Here, we experimentally demonstrate multi-slice ptychographic electron tomography, which allows atomic resolution three-dimensional phase-contrast imaging in a volume surpassing the depth of field limits. We reconstruct tilt-series 4D-STEM measurements of a $\mathrm{Co_3O_4}$ nanocube, yielding 2 Å axial and 0.7 Å transverse resolution in a reconstructed volume of $\mathrm{(18.2\,nm)^3}$. Our results demonstrate a 13.5-fold improvement in axial resolution compared to multi-slice ptychography while retaining the atomic lateral resolution and the capability to image volumes beyond the depth of field limit. Multi-slice ptychographic electron tomography significantly expands the volume of materials accessible using high-resolution electron microscopy. We discuss further experimental and algorithmic improvements necessary to also resolve single weakly scattering atoms in 3D.

36 MATERIALS SCIENCE↗

Evidence of Recent Material Transport within a Binary Asteroid System

Images acquired by the Double Asteroid Redirection Test (DART) before its impact into Dimorphos—the moon of the Didymos binary asteroid system—unexpectedly reveal a set of discontinuous rays spanning the imaged surface. These albedo features are visible only after correcting for lighting differences, which normalize the effects of the pervasive boulders that cover the surface. Comparison to physical experiments and numerical simulations shows that these bright, fan-shaped albedo features are consistent with the aftermath of a low-velocity impact into a field of boulders and provide our first direct evidence for the transfer of material in a binary asteroid system due to the shedding material from radiative torques. Parts of these and possible additional albedo markings from the reentry of boulders after the DART impact may be visible to the Hera mission when it explores the post-DART Didymos system.

Astronomy and AstroPhysics↗

Quantifying particle-scale 3D granular dynamics during rapid compaction from time-resolved in situ 2D x-ray images

Understanding the particle-scale dynamics of granular materials during rapid compaction and flow is of fundamental importance for manufacturing, planetary science, geology, and defense applications. Time-resolved 2D radiography and static 3D x-ray tomography are powerful in situ tools for studying particle-scale dynamics but provide detail only in 2D or with significant time-scale limitations, respectively. Here, we introduce a new method that uses 2D in situ x-ray imaging for determining time-resolved 3D particle-scale dynamics in rapidly compressed granular materials. The method employs initial particle packing structures obtained from x-ray tomography, a 2D x-ray image generation algorithm, and an optimization algorithm. We first describe and validate the method using finite element simulations. Furthermore, we then apply the technique to x-ray phase-contrast images obtained during rapid compaction of granular materials with varying particle morphology and sample thickness. The depth-resolved particle-scale dynamics reveal complex velocity and porosity fields evolving heterogeneously along and perpendicular to the compaction direction. We characterize these features, their fluctuations near the compaction front, and the compaction front thickness. Our technique can be applied to understanding granular dynamics during rapid compaction events, and rearrangements during slower, but non-quasi-static, flows.

36 MATERIALS SCIENCE↗

Poster for 12th World Conference for Neutron Radiography (WCNR-12)

Complimentary Relationships Between Neutron Computed Radiography and Digital X-ray Radiography of Radioactive Specimens The Transient Reactor Test (TREAT) Facility is a 19,000 MW reactor located at the Idaho National Laboratory which is used for transient testing of materials and experiments. A neutron radiography facility is installed which allows for low resolution neutron imaging with a capability of items up to 20 cm wide and 400 cm long. Along with the neutron radiography facility, a 370 kV digital X-ray system is located onsite for when X-ray imaging is more practical or when rapid imaging is requested. The X-ray facility can accommodate specimens up to 61 cm wide and 1000 cm long. This poster discusses the complimentary relationship between transfer-method Neutron Computed Radiography (nCR) and Digital X-ray Radiography (DR) imaging of radioactive specimens along with practical applications for nuclear fuels and materials testing programs. Both nCR and DR images were acquired of inert gas and water filled apparatus containing differing materials at varying radiation levels. Highly radioactive items have no effect on nCR image quality whereas radioactivity has varying degrees of effect in DR. Radioactive items as high as 20 mSv/h have been successfully imaged using X-ray DR methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nanoscale imaging of Gilbert damping using signal amplitude mapping

Ferromagnetic resonance force microscopy (FMRFM) is a powerful scanned probe technique that uses sub-micrometer-scale, spatially localized standing spin wave modes (LMs) to perform local ferromagnetic resonance (FMR) measurements. In this work, we show the spatially resolved imaging of Gilbert damping in a ferromagnetic material (FM) using FMRFM. Typically damping is measured from the FMR linewidth. We demonstrate an approach to image the spatial variation of Gilbert damping utilizing the LM resonance peak height to measure the LM resonance cone angle. This approach enables determination of damping through field-swept FMRFM at a single excitation frequency. The extreme force sensitivity of similar to 2 fN at room temperature can resolve changes of Gilbert damping as small as ~2 x 10 -4 at 2GHz, corresponding to ~0.16Oe in FMR linewidth resolution. This high sensitivity, high spatial resolution, and single frequency imaging of Gilbert damping creates the opportunity to study spin interactions at the interface between an insulating FM and a small volume of nonmagnetic material such as atomically thin two-dimensional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raw electron microscopy images for "The Importance of Nano-edges in Atomic Stencilling and Chiroptically Active Assembly of Patchy Gold Tetrahedra"

This dataset contains the raw transmission electron microscopy (TEM) and scanning electron microscopy (SEM) images used in the main figures of the paper “The Importance of Nano-edges in Atomic Stencilling and Chiroptically Active Assembly of Patchy Gold Tetrahedra (2026).” All the images were acquired at the Materials Research Laboratory, University of Illinois at Urbana-Champaign, by Qian Chen group. 1. We provide five subfolders, each named according to the corresponding figure numbers in the paper. 2. All files in the subfolders for Figures 1–3 and 5 are named as "Panel [letter]_*", where [letter] (e.g., a, b, c) represents the raw images used for the corresponding panels. 3. All files in the subfolder for Figure 4 correspond to panel f and show the configurations of patchy tetrahedra synthesized at varying concentrations of iodide and 2-naphthalenethiol. They are named "Experiment_[number]", where [number] represents the corresponding data points in the phase diagram. 4. In TEM images, the bright and dark regions indicate the polymer patches and nanoparticle cores, respectively. 5. In SEM images, the bright and dark regions indicate the nanoparticle cores and polymer patches, respectively. 6. Abbreviations in file names: HAADF-STEM (high-angle annular dark-field scanning transmission electron microscopy), PINEM (photon-induced near-field electron microscopy), and RCP/LCP (left-/right-handed circularly polarized).

chirality↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wet-chemical etching of FIB lift-out TEM lamellae for damage-free analysis of 3-D nanostructures

Reducing ion beam damage from the focused ion beam (FIB) during fabrication of cross sections is a well-known challenge for materials characterization, especially cross sectional characterization of nanostructures. To address this, a new method has been developed for cross section fabrication enabling high resolution transmission electron microscopy (TEM) analysis of 3-D nanostructures free of surrounding material and free of damage detectable by TEM analysis. Before FIB processing, nanopillars are encapsulated in a sacrificial oxide which acts as a protective layer during FIB milling. Furthermore, the cross sectional TEM lamella containing the nanopillars is then mounted and thinned with some modifications to conventional FIB sample preparation that provide stability for the lamella during the following wet-chemical dip etch. The wet-chemical etch of the TEM lamella removes the sacrificial oxide layer, freeing the nanopillars from any material that would obscure TEM imaging. Both high resolution TEM and aberration corrected scanning TEM images of Si/SiGe pillars with diameters down to 30 nm demonstrate the successful application of this approach.

3-d nanostructure analysis↗

Ultrasonic Imaging Technology Helps American Manufacturer of Nondestructive Evaluation Equipment Become More Competitive in the Global Market

Sonix, Inc., of Springfield, Virginia, has implemented ultrasonic imaging methods developed at the NASA Lewis Research Center. These methods have heretofore been unavailable on commercial ultrasonic imaging systems and provide significantly more sensitive material characterization than conventional high-resolution ultrasonic c-scanning. The technology transfer is being implemented under a cooperative agreement between NASA and Sonix, and several invention disclosures have been submitted by Dr. Roth to protect Lewis interests. Sonix has developed ultrasonic imaging systems used worldwide for microelectronics, materials research, and commercial nondestructive evaluation (NDE). In 1993, Sonix won the U.S. Department of Commerce "Excellence in Exporting" award. Lewis chose to work with Sonix for two main reasons: (1) Sonix is an innovative leader in ultrasonic imaging systems, and (2) Sonix was willing to apply the improvements we developed with our in-house Sonix equipment. This symbiotic joint effort has produced mutual benefits. Sonix recognized the market potential of our new and highly sensitive methods for ultrasonic assessment of material quality. We, in turn, see the cooperative effort as an effective means for transferring our technology while helping to improve the product of a domestic firm.

Source record↗

Secondary Ion Mass Spectral Imaging of Metals and Alloys

Secondary Ion Mass Spectrometry (SIMS) is an outstanding technique for Mass Spectral Imaging (MSI) due to its notable advantages, including high sensitivity, selectivity, and high dynamic range. As a result, SIMS has been employed across many domains of science. In this review, we provide an in-depth overview of the fundamental principles underlying SIMS, followed by an account of the recent development of SIMS instruments. The review encompasses various applications of specific SIMS instruments, notably static SIMS with time-of-flight SIMS (ToF-SIMS) as a widely used platform and dynamic SIMS with Nano SIMS and large geometry SIMS as successful instruments. We particularly focus on SIMS utility in microanalysis and imaging of metals and alloys as materials of interest. Additionally, we discuss the challenges in big SIMS data analysis and give examples of machine leaning (ML) and Artificial Intelligence (AI) for effective MSI data analysis. Finally, we recommend the outlook of SIMS development. It is anticipated that in situ and operando SIMS has the potential to significantly enhance the investigation of metals and alloys by enabling real-time examinations of material surfaces and interfaces during dynamic transformations.

36 MATERIALS SCIENCE↗

Carbon Nanotube-Enhanced Carbon-Phenenolic Ablator Material

This viewgraph presentation reviews the use of PICA (phenolic impregnated carbon ablator) as the selected material for heat shielding for future earth return vehicles. It briefly reviews the manufacturing of PICA and the advantages for the use of heat shielding, and then explains the reason for using Carbon Nanotubes to improve strength of phenolic resin that binds carbon fibers together. It reviews the work being done to create a carbon nanotube enhanced PICA. Also shown are various micrographic images of the various PICA materials.

Kikolaev, P.↗

Organic Analysis in the Miller Range 090657 CR2 Chondrite: Part 3 C and N Isotopic Imaging

Primitive carbonaceous chondrites contain a wide variety of organic material, ranging from soluble discrete molecules to insoluble nanoglobules of macro-molecular carbon. The relationship between the soluble organic molecules, macromolecular organic material, and host minerals are poorly understood. Large H, C and N isotopic anomalies suggest some organic components formed in low-T interstellar or outer Solar System environments. The highest isotope anomalies occur in m-scale inclusions in the most primitive materials, such as cometary dust and the least altered carbonaceous chondrites. Often, the hosts of these isotopically anomalous 'hotspots' are discrete organic nanoglobules that probably formed in the outermost reaches of the protosolar disk or cold molecular cloud. Molecular and isotopic studies of meteoritic organic matter are aimed at identifying the chemical properties and formation processes of interstellar organic materials and the subsequent chemical evolutionary pathways in various Solar System environments. The combination of soluble and insoluble analyses with in situ and bulk studies provides powerful constraints on the origin and evolution of organic matter in the Solar System. Using macroscale extraction and analysis techniques as well as microscale in situ observations we have been studying both insoluble and soluble organic material in primitive astromaterial samples. Here, we present results of bulk C and N isotopic measurements and coordinated in situ C and N isotopic imaging and mineralogical and textural studies of carbonaceous materials in a Cr2 carbonaceous chondrite. In accompanying abstracts we discuss the morphology and distribution of carbonaceous components and soluble organic species of this meteorite.

Messenger, S.↗