Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Sample Return from the Stardust Mission

On January 2,2004, the STARDUST spacecraft made a close flyby (236 km) of the nucleus of a comet - Comet Wild 2. During the flyby the spacecraft collected samples of dust from the coma of the comet. These samples were successfully returned to Earth on January 15,2006. After a six month preliminary examination to establish the nature of the returned samples, they will be made available to the general scientific community for study. STARDUST is one of the missions carried out under NASA's Discovery Mission Program. During my talk I will present a brief overview of the scientific goals of the STARDUST mission and describe the mission's design and flight. I will also discuss the reentry and recovery of the Stardust Sample Return Capsule (SRC) in Utah, with an emphasis on those aspects of the recovery important for minimizing the degree of contamination (particularly organic contamination) of the samples. Finally, I will discuss some of the results coming out of the preliminary examination of the returned samples, with an emphasis on the nature of organic materials found in the samples.

Source record↗

Curation and Analysis of Samples from Comet Wild-2 Returned by NASA's Stardust Mission

The NASA Stardust mission returned the first direct samples of a cometary coma from comet 81P/Wild‐2 in 2006. Intact capture of samples encountered at 6 km/s was enabled by the use of aerogel, an ultralow dense silica polymer. Approximately 1000 particles were captured, with micron and submicron materials distributed along ~mm scale length tracks. This sample collection method and the fine scale of the samples posed new challenges to the curation and cosmochemistry communities. Sample curation involved extensive, detailed photo‐documentation and delicate micro‐surgery to remove particles without loss from the aerogel tracks. This work had to be performed in highly clean facility to minimize the potential of contamination. JSC Curation provided samples ranging from entire tracks to micrometer‐sized particles to external investigators. From the analysis perspective, distinguishing cometary materials from aerogel and identifying the potential alteration from the capture process were essential. Here, transmission electron microscopy (TEM) proved to be the key technique that would make this possible. Based on TEM work by ourselves and others, a variety of surprising findings were reported, such as the observation of high temperature phases resembling those found in meteorites, rarely intact presolar grains and scarce organic grains and submicrometer silicates. An important lesson from this experience is that curation and analysis teams must work closely together to understand the requirements and challenges of each task. The Stardust Mission also has laid important foundation to future sample returns including OSIRIS‐REx and Hayabusa II and future cometary nucleus sample return missions.

Nakamura-Messenger, Keiko↗

A Pilot Evaluation of a 4-Dimensional Cone-Beam Computed Tomographic Scheme Based on Simultaneous Motion Estimation and Image Reconstruction

Purpose: To evaluate the performance of a 4-dimensional (4-D) cone-beam computed tomographic (CBCT) reconstruction scheme based on simultaneous motion estimation and image reconstruction (SMEIR) through patient studies. Methods and Materials: The SMEIR algorithm contains 2 alternating steps: (1) motion-compensated CBCT reconstruction using projections from all phases to reconstruct a reference phase 4D-CBCT by explicitly considering the motion models between each different phase and (2) estimation of motion models directly from projections by matching the measured projections to the forward projection of the deformed reference phase 4D-CBCT. Four lung cancer patients were scanned for 4 to 6 minutes to obtain approximately 2000 projections for each patient. To evaluate the performance of the SMEIR algorithm on a conventional 1-minute CBCT scan, the number of projections at each phase was reduced by a factor of 5, 8, or 10 for each patient. Then, 4D-CBCTs were reconstructed from the down-sampled projections using Feldkamp-Davis-Kress, total variation (TV) minimization, prior image constrained compressive sensing (PICCS), and SMEIR. Using the 4D-CBCT reconstructed from the fully sampled projections as a reference, the relative error (RE) of reconstructed images, root mean square error (RMSE), and maximum error (MaxE) of estimated tumor positions were analyzed to quantify the performance of the SMEIR algorithm. Results: The SMEIR algorithm can achieve results consistent with the reference 4D-CBCT reconstructed with many more projections per phase. With an average of 30 to 40 projections per phase, the MaxE in tumor position detection is less than 1 mm in SMEIR for all 4 patients. Conclusion: The results from a limited number of patients show that SMEIR is a promising tool for high-quality 4D-CBCT reconstruction and tumor motion modeling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pragmatic protocols for working cleanly when measuring ice nucleating particles

We report that measuring ice nucleating particles (INPs) is critical for understanding, and modeling, cloud formation, reflectivity, and precipitation patterns. However, because INPs are very rare in the atmosphere, but abundant—sometimes alarmingly so—in the dust that covers all work surfaces, contamination during processing of collected aerosol samples can be a significant hindrance to obtaining accurate measures of INPs. In preparing this technical note, we questioned the cleanliness of every collection and processing step involved in making immersion freezing measurements of INPs re-suspended from filter samples. The aim was to identify, and then minimize, all potential sources of significant contamination, including containers and tools used to store filters and prepare liquid suspensions, gloves, work surfaces, and the polymerase chain reaction (PCR) trays commonly used for sample analysis. While plasticware released few INPs, most gloves readily shed them, but this can be mitigated by using washed cleanroom vinyl or polyethylene gloves. Work surfaces, even those that had been cleaned, were prodigious reservoirs of contaminating INPs, but simply covering them with aluminum foil will provide an INP-free surface. By applying these practices, we developed a method to reduce the background level of INPs on Nuclepore™ polycarbonate filters in our tests to 0 at -25 °C and < 20 at -27 °C, making them suitable for use in all sampling environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraining Cross Section and Beam Systematics for Future NOvA Sterile Neutrino Search

he NOvA (NuMI Off-axis $\nu_e$ Appearance) experiment measures neutrino oscillations in a nearly pure muon (anti)neutrino beam over a 810 km baseline. We search for sterile neutrino driven oscillations in both neutral current (NC) and charged current (CC) muon neutrino samples. A deficit of NC interactions at the Far Detector could occur since sterile neutrinos do not couple to the Z boson. A modulation of the muon neutrino disappearance probability is possible due to a new mass splitting. The NuMI beam line is capable of running in forward or reverse horn current modes, which creates a neutrino or antineutrino beam, respectively. Samples collected in forward horn current (FHC) or reverse horn current (RHC) modes are subject to beam optics uncertainties, in addition to cross section and hadron production uncertainties. We explore the ategories. To tackle reduction of cross section uncertainties, we study how splitting the neutral current (NC) samples can impact the systematic reduction and its implications on oscillation parameters, leveraging results from Monte Carlo simulations. Additionally, we look at the possibility of using a $\nu$-on-e scattering sample. The $\nu$-on-e scattering process has minimal cross section uncertainties compared to that of neutrino-nucleus interactions, which can help constrain the overall flux normalizations. Using both the ZHC sample, NC split sample, and $\nu$-on-e scattering sample jointly with FHC samples would reduce the focusing uncertainties and the hadron production uncertainties in the future sterile analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DHARMA - Discriminant hyperplane abstracting residuals minimization algorithm for separating clusters with fuzzy boundaries

Learning of discriminant hyperplanes in imperfectly supervised or unsupervised training sample sets with unreliably labeled samples along the fuzzy joint boundaries between sample clusters is discussed, with the discriminant hyperplane designed to be a least-squares fit to the unreliably labeled data points. (Samples along the fuzzy boundary jump back and forth from one cluster to the other in recursive cluster stabilization and are considered unreliably labeled.) Minimization of the distances of these unreliably labeled samples from the hyperplanes does not sacrifice the ability to discriminate between classes represented by reliably labeled subsets of samples. An equivalent unconstrained linear inequality problem is formulated and algorithms for its solution are indicated. Landsat earth sensing data were used in confirming the validity and computational feasibility of the approach, which should be useful in deriving discriminant hyperplanes separating clusters with fuzzy boundaries, given supervised training sample sets with unreliably labeled boundary samples.

Dasarathy, B. V.↗

Elimination of the Characterization of DWPF Pour Stream Sample and the Glass Fabrication and Testing of the DWPF Sludge Batch Qualification Sample

A recommendation to eliminate all characterization of pour stream glass samples and the glass fabrication and Product Consistency Test (PCT) of the sludge batch qualification sample was made by a Six-Sigma team chartered to eliminate non-value-added activities for the Defense Waste Processing Facility (DWPF) sludge batch qualification program and is documented in the report SS-PIP-2006-00030. That recommendation was supported through a technical data review by the Savannah River National Laboratory (SRNL) and is documented in the memorandums SRNL-PSE-2007-00079 and SRNL-PSE-2007-00080. At the time of writing those memorandums, the DWPF was processing sludge-only waste but, has since transitioned to a coupled operation (sludge and salt). The SRNL was recently tasked to perform a similar data review relevant to coupled operations and re-evaluate the previous recommendations. This report evaluates the validity of eliminating the characterization of pour stream glass samples and the glass fabrication and Product Consistency Test (PCT) of the sludge batch qualification samples based on sludge-only and coupled operations. The pour stream sample has confirmed the DWPF's ability to produce an acceptable waste form from Slurry Mix Evaporator (SME) blending and product composition/durability predictions for the previous sixteen years but, ultimately the pour stream analysis has added minimal value to the DWPF's waste qualification strategy. Similarly, the information gained from the glass fabrication and PCT of the sludge batch qualification sample was determined to add minimal value to the waste qualification strategy since that sample is routinely not representative of the waste composition ultimately processed at the DWPF due to blending and salt processing considerations. Moreover, the qualification process has repeatedly confirmed minimal differences in glass behavior from actual radioactive waste to glasses fabricated from simulants or batch chemicals. In contrast, the variability study has significantly added value to the DWPF's qualification strategy. The variability study has evolved to become the primary aspect of the DWPF's compliance strategy as it has been shown to be versatile and capable of adapting to the DWPF's various and diverse waste streams and blending strategies. The variability study, which aims to ensure durability requirements and the PCT and chemical composition correlations are valid for the compositional region to be processed at the DWPF, must continue to be performed. Due to the importance of the variability study and its place in the DWPF's qualification strategy, it will also be discussed in this report. An analysis of historical data and Production Records indicated that the recommendation of the Six Sigma team to eliminate all characterization of pour stream glass samples and the glass fabrication and PCT performed with the qualification glass does not compromise the DWPF's current compliance plan. Furthermore, the DWPF should continue to produce an acceptable waste form following the remaining elements of the Glass Product Control Program; regardless of a sludge-only or coupled operations strategy. If the DWPF does decide to eliminate the characterization of pour stream samples, pour stream samples should continue to be collected for archival reasons, which would allow testing to be performed should any issues arise or new repository test methods be developed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Convergence Rates for Empirical Estimation of Binary Classification Bounds

Bounding the best achievable error probability for binary classification problems is relevant to many applications including machine learning, signal processing, and information theory. Many bounds on the Bayes binary classification error rate depend on information divergences between the pair of class distributions. Recently, the Henze–Penrose (HP) divergence has been proposed for bounding classification error probability. We consider the problem of empirically estimating the HP-divergence from random samples. We derive a bound on the convergence rate for the Friedman–Rafsky (FR) estimator of the HP-divergence, which is related to a multivariate runs statistic for testing between two distributions. The FR estimator is derived from a multicolored Euclidean minimal spanning tree (MST) that spans the merged samples. We obtain a concentration inequality for the Friedman–Rafsky estimator of the Henze–Penrose divergence. We validate our results experimentally and illustrate their application to real datasets.

97 MATHEMATICS AND COMPUTING↗

Delta Modulation

An optimum adaptive delta modulator-demodulator configuration is derived. This device utilizes two past samples to obtain a step size which minimizes the mean square error for a Markov Gaussian source. The optimum system is compared using computer simulations with the linear delta modulator and an enhanced Abate delta modulator. In addition the performance is compared to the rate distortion bound for a Markov source. It is shown that the optimum delta modulator is neither quantization nor slope-overload limited. The results show that the output signal-to-noise ratio is independent of the input signal power and is subject only to the limitations of the hardware employed. In addition, voice was recorded using these systems. The demodulated voice indicates negligible degradation is caused by the optimum system and by the enhanced Abate system while the linear delta modulator suffers significant degradation at a sampling frequency of 56 kilobits/sec.

Schilling, D. L.↗

Determination of Silicon in Hydrazine

Inductively coupled plasma-mass spectrometry (ICP-MS) is a highly sensitive technique sometimes used for the trace determination of silicon at a mass-to-charge (m/z) ratio of 28, the most abundant natural isotope of silicon. Unfortunately, ICP-MS is unable to differentiate between other sources of m/z 28 and false positive results for silicon will result when other sources of m/z 28 are present. Nitrogen was a major source of m/z 28 and contributes to the m/z 28 signal when hydrazine sample or nitric acid preservative is introduced into the plasma. Accordingly, this work was performed to develop a sample preparation step coupled with an ICP-MS analysis that minimized non-silicon sources of m/z 28. In the preparatory step of this method, the hydrazine sample was first decomposed predominately to nitrogen gas and water with copper-catalyzed hydrogen peroxide. In the analysis step, ICP-MS was used without nitric acid preservative in samples or standards. Glass, a potential source of silicon contamination, was also avoided where possible. The method was sensitive, accurate, and reliable for the determination of silicon in monopropellant grade hydrazine (MPH) in AF-E-332 elastomer leaching tests. Results for silicon in MPH were comparable to those reported in the literature for other studies.

McClure, Mark B.↗

GeoLab in NASA's Pressurized Excursion Module: First Results from the 2010 Field Trials

Before humans explore other planets, NASA must develop advanced techniques for collection, preservation and return of unique extraterrestrial samples. To help evaluate hardware requirements and operational concepts for future sample-return missions, we designed and built GeoLab our first generation lab for geological samples into NASA s Habitat Demonstration Unit in the Pressurized Excursion Module (HDU1-PEM). The center of GeoLab is a glovebox for the examination of samples in a shirt-sleeve environment. As part of a deployable habitat, GeoLab can participate in NASA s analog missions that simulate planetary exploration activities and support the testing of relevant technologies for collecting and handling geological samples. Over time, these tests will evaluate sample handling environments (field and lab), sampling tools and analytical instruments, and different scenarios involving both robotic and human procedures. The GeoLab design supports evolving tests and configurations. The glovebox is mounted on the habitat bulkhead, with three sample pass-though chambers that allow for direct sample transfer into the glovebox from the outside. The glovebox design and construction (low-particle shedding, minimally off-gassing materials) provides a clean environment to reduce sample contamination; in the future, we will integrate a positive pressure, enriched nitrogen atmosphere. The glovebox is equipped with configurable instrument ports. The 2010 test included a mass balance, a stereomicroscope with a HD camera for detailed imaging of samples, and a handheld XRF analyzer for preliminary geochemical characterization of samples. Network cameras provided context imagery and sample handling activities. We present early results from the initial field trial of GeoLab during the 2010 Desert Research and Technology Studies (D-RATS) planetary analog test near Flagstaff AZ. The 2010 D-RATS mission involved two rovers, the habitat with GeoLab, four crew members, and a team of scientists and flight controllers. The crewed rovers conducted geological traverses and collected samples on the planetary surface. Selected samples were transferred into GeoLab for detailed examination and initial analysis, providing critical data to the science team for evaluation and prioritization of samples.

Evans, Cynthia A.↗

Emulator-Based Bayesian Calibration of the CISNET Colorectal Cancer Models

Purpose To calibrate Cancer Intervention and Surveillance Modeling Network (CISNET)'s SimCRC, MISCAN-Colon, and CRC-SPIN simulation models of the natural history colorectal cancer (CRC) with an emulator-based Bayesian algorithm and internally validate the model-predicted outcomes to calibration targets.Methods We used Latin hypercube sampling to sample up to 50,000 parameter sets for each CISNET-CRC model and generated the corresponding outputs. We trained multilayer perceptron artificial neural networks (ANNs) as emulators using the input and output samples for each CISNET-CRC model. We selected ANN structures with corresponding hyperparameters (i.e., number of hidden layers, nodes, activation functions, epochs, and optimizer) that minimize the predicted mean square error on the validation sample. We implemented the ANN emulators in a probabilistic programming language and calibrated the input parameters with Hamiltonian Monte Carlo-based algorithms to obtain the joint posterior distributions of the CISNET-CRC models' parameters. We internally validated each calibrated emulator by comparing the model-predicted posterior outputs against the calibration targets.Results The optimal ANN for SimCRC had 4 hidden layers and 360 hidden nodes, MISCAN-Colon had 4 hidden layers and 114 hidden nodes, and CRC-SPIN had 1 hidden layer and 140 hidden nodes. The total time for training and calibrating the emulators was 7.3, 4.0, and 0.66 h for SimCRC, MISCAN-Colon, and CRC-SPIN, respectively. The mean of the model-predicted outputs fell within the 95% confidence intervals of the calibration targets in 98 of 110 for SimCRC, 65 of 93 for MISCAN, and 31 of 41 targets for CRC-SPIN.Conclusions Using ANN emulators is a practical solution to reduce the computational burden and complexity for Bayesian calibration of individual-level simulation models used for policy analysis, such as the CISNET CRC models. In this work, we present a step-by-step guide to constructing emulators for calibrating 3 realistic CRC individual-level models using a Bayesian approach.

artificial neural networks↗

Aerosol Inlets for a Mid-Sized Uncrewed Aerial System (UAS)

The purpose of this technical report is to document the efforts to design and test two inlet systems for aerosol sampling suitable for deployment on a medium-sized fixed-wing Uncrewed Aerial System (UAS). This work, which was supported by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, was conducted at the Pacific Northwest National Laboratory (PNNL) for the ARM Aircraft Facility (AAF) starting in November 2017. The current work is a part of AAF efforts to instrument the ArcticShark (a mid-sized UAS owned and operated by the AAF) for atmospheric research and develop a scientific payload for deployment on a similar-sized UAS with minimal adaptation and integration. An aerosol inlet system is necessary to sample and transport ambient air sample to the scientific instrumentation with minimal distortions to the aerosols. Two isokinetic aerosol inlets were designed: the first is a simple passive system for a single instrument suitable to be installed in a wing pylon; the second is a system with active control designed to sample and distribute air among several heterogeneous instruments and to provide basic humidity control of the air sample so that the measured aerosol parameters should correspond to “dry” conditions (a common requirement). Both systems could be easily adapted for deployment on another platform and/or with a different set of instrumentation. Several conducted flight tests showed that the inlets’ performance met our design goals.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Inlets for a Mid-Sized Uncrewed Aerial System (UAS)

The purpose of this technical report is to document the efforts to design and test two inlet systems for aerosol sampling suitable for deployment on a medium-sized fixed-wing Uncrewed Aerial System (UAS). This work, which was supported by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, was conducted at the Pacific Northwest National Laboratory (PNNL) for the ARM Aircraft Facility (AAF) starting in November 2017. The current work is a part of AAF efforts to instrument the ArcticShark (a mid-sized UAS owned and operated by the AAF) for atmospheric research and develop a scientific payload for deployment on a similar-sized UAS with minimal adaptation and integration. An aerosol inlet system is necessary to sample and transport ambient air sample to the scientific instrumentation with minimal distortions to the aerosols. Two isokinetic aerosol inlets were designed: the first is a simple passive system for a single instrument suitable to be installed in a wing pylon; the second is a system with active control designed to sample and distribute air among several heterogeneous instruments and to provide basic humidity control of the air sample so that the measured aerosol parameters should correspond to “dry” conditions (a common requirement). Both systems could be easily adapted for deployment on another platform and/or with a different set of instrumentation. Several conducted flight tests showed that the inlets’ performance met our design goals.

42 ENGINEERING↗

Frequency extrapolation by nonconvex compressive sensing

Tomographic imaging modalities sample subjects with a discrete, finite set of measurements, while the underlying object function is continuous. Because of this, inversion of the imaging model, even under ideal conditions, necessarily entails approximation. The error incurred by this approximation can be important when there is rapid variation in the object function or when the objects of interest are small. In this work, we investigate this issue with the Fourier transform (FT), which can be taken as the imaging model for magnetic resonance imaging (MRl) or some forms of wave imaging. Compressive sensing has been successful for inverting this data model when only a sparse set of samples are available. We apply the compressive sensing principle to a somewhat related problem of frequency extrapolation, where the object function is represented by a super-resolution grid with many more pixels than FT measurements. The image on the super-resolution grid is obtained through nonconvex minimization. The method fully utilizes the available FT samples, while controlling aliasing and ringing. The algorithm is demonstrated with continuous FT samples of the Shepp-Logan phantom with additional small, high-contrast objects.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a vadose zone advanced monitoring system: Tools to assess groundwater vulnerability

Performing repeat pore-fluid sampling over long time-scales can provide valuable information on unsaturated zone contaminants and their potential flux to ground water. This information can be used to manage groundwater remedies and identify contaminants that need to be sequestered in the vadose zone to minimize flux to ground water. Pore-water samples are commonly used to obtain contaminant concentrations within the vadose zone, but existing methods are limited as they only provide a single sample at one location and time. The vadose zone advanced monitoring system (VZAMS) has been designed to integrate multiple technologies into a single down-borehole system that allows for sampling of pore fluids (liquid and gas) to provide information about contamination and hydraulic conditions at multiple depths (~0.3-m intervals) within a cased borehole. Testing has been completed at the laboratory scale to verify the sampling elements of VZAMS, including geochemical testing for representative contaminants known to exist at the Hanford Site, located in southeastern Washington State. Physical tests focused on the ability of the sampler to draw fluid under unsaturated conditions. Initial geochemical testing showed that the stainless steel material used with the porous cuff may affect the sampled concentrations of redox-sensitive contaminants under very dry conditions. Additional laboratory testing demonstrated that the VZAMS components are able to collect representative samples for substances of interest under expected field conditions. In this paper, the design and functionality of a novel instrument are demonstrated in support of subsequent testing in the field.

54 ENVIRONMENTAL SCIENCES↗

Elemental and Isotopic Analysis of Uranium Oxide an NIST Glass Standards by FEMTOSECOND-LA-ICP-MIC-MS

The objective of this work was to test and demonstrate the analytical figures of merit of a femtosecond-laser ablation (fs-LA) system coupled with an inductively coupled plasma-multi-ion collector-mass spectrometer (ICP-MIC-MS). The mobile fs-LA sampling system was designed and assembled at Ames Laboratory and shipped to Oak Ridge National Laboratory (ORNL), where it was integrated with an ICP-MIC-MS. The test period of the integrated systems was February 2-6, 2009. Spatially-resolved analysis of particulate samples is accomplished by 100-shot laser ablation using a fs-pulsewidth laser and monitoring selected isotopes in the resulting ICP-MS transient signal. The capability of performing high sensitivity, spatially resolved, isotopic analyses with high accuracy and precision and with virtually no sample preparation makes fs-LA-ICP-MIC-MS valuable for the measurement of actinide isotopes at low concentrations in very small samples for nonproliferation purposes. Femtosecond-LA has been shown to generate particles from the sample that are more representative of the bulk composition, thereby minimizing weaknesses encountered in previous work using nanosecond-LA (ns-LA). The improvement of fs- over ns-LA sampling arises from the different mechanisms for transfer of energy into the sample in these two laser pulse-length regimes. The shorter duration fs-LA pulses induce less heating and cause less damage to the sample than the longer ns pulses. This results in better stoichiometric sampling (i.e., a closer correlation between the composition of the ablated particles and that of the original solid sample), which improves accuracy for both intra- and inter-elemental analysis. The primary samples analyzed in this work are (a) solid uranium oxide powdered samples having different {sup 235}U to {sup 238}U concentration ratios, and (b) glass reference materials (NIST 610, 612, 614, and 616). Solid uranium oxide samples containing {sup 235}U in depleted, natural, and enriched abundances were analyzed as particle aggregates immobilized in a collodion substrate. The uranium oxide samples were nuclear reference materials (CRMs U0002, U005-A, 129-A, U015, U030-A, and U050) obtained from New Brunswick Laboratory-USDOE.

07 ISOTOPE AND RADIATION SOURCES↗