Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Species-Selective Detection of Volatile Organic Compounds by Ionic Liquid-Based Electrolyte Using Electrochemical Methods

The detection of volatile organic compounds (VOCs) is an important topic for environmental safety and public health. However, the current commercial VOC detectors suffer from cross-sensitivity and low reproducibility. In this work, we present species-selective detection for VOCs using an electrochemical cell based on ionic liquid (IL) electrolytes with features of high selectivity and reliability. The voltammograms measured with the IL-based electrolyte absorbing different VOCs exhibited species-selective features that were extracted and classified by linear discriminant analysis (LDA). The detection system could identify as many as four types of VOCs, including methanol, ethanol, acetone, formaldehyde, and additional water. A mixture of methanol and formaldehyde was detected as well. The sample required for the VOCs classification system was 50 μL, or 1.164 mmol, on average. The response time for each VOC measurement is as fast as 24 s. The volume of VOCs such as formaldehyde in solution could also be quantified by LDA and electrochemical impedance spectroscopy techniques, respectively. The system showed a tunable detection range for 1.6 and 16% (w/v) CH 2 O solution by adjusting the composition of the electrolyte. The limit of detection was as low as 1 μL. For the 1.6% CH 2 O solution, the linearity calibration range was determined to be from 5.30 to 53.00 μmol with a limit of detection at 0.53 μmol. The mechanisms for VOCs determination and quantification are also thoroughly discussed. Finally, it is expected that this work could provide a new insight into the concept of electrochemical detection of VOCs with machine learning analysis and be applied to both VOCs gas monitoring and fluid detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vapor detection and vapor pressure measurements of fentanyl and fentanyl hydrochloride salt at ambient temperatures

There is a need for non-contact, real-time vapor detection of drugs to combat illicit transportation and help curb the opioid epidemic. The low-volatility of drugs, like fentanyl, makes room temperature vapor detection of illicit drugs challenging, but feasible by atmospheric flow tube-mass spectrometry (AFT-MS). AFT-MS is a non-contact vapor detection approach capable of ultra-trace detection of drugs, including fentanyl and its analogs at low parts-per-quadrillion (ppqv) levels. The determination of vapor pressure values of fentanyl is necessary to understand potential vapor concentrations that may be available for detection. In this paper, vapor pressures of fentanyl free base and fentanyl hydrochloride salt (a common form of the illicit drug) were measured as a function of temperature at or near ambient conditions using the transpiration (gas saturation) method and AFT-MS. Based on our measurements, the vapor pressure of fentanyl at 25 °C is 9.0 × 10-14 atm (90 ppqv), and the vapor pressure of fentanyl hydrochloride at 25 °C is 1.8 x 10-17 atm (0.018 ppqv). We also demonstrate non-contact, real-time vapor detection of fentanyl. Preconcentration of vapors can further extend the detection capabilities. The collection, desorption, and detection of fentanyl vapors at ambient conditions was demonstrated for sampling times of seconds to an hour resulting in increased signal. AFT-MS is a viable detection method of fentanyl and other drugs for screening of packages and cargo.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

DETECTION OF POTENTIAL TRANSIT SIGNALS IN THE FIRST 12 QUARTERS OF KEPLER MISSION DATA

We present the results of a search for potential transit signals in the first three years of photometry data acquired by the Kepler mission. The targets of the search include 112,321 targets that were observed over the full interval and an additional 79,992 targets that were observed for a subset of the full interval. From this set of targets we find a total of 11,087 targets that contain at least one signal that meets the Kepler detection criteria: periodicity of the signal, an acceptable signal-to-noise ratio, and three tests that reject false positives. Each target containing at least one detected signal is then searched repeatedly for additional signals, which represent multi-planet systems of transiting planets. When targets with multiple detections are considered, a total of 18,406 potential transiting planet signals are found in the Kepler mission data set. The detected signals are dominated by events with relatively low signal-to-noise ratios and by events with relatively short periods. The distribution of estimated transit depths appears to peak in the range between 20 and 30 parts per million, with a few detections down to fewer than 10 parts per million. The detections exhibit signal-to-noise ratios from 7.1{sigma}, which is the lower cutoff for detections, to over 10,000{sigma}, and periods ranging from 0.5 days, which is the shortest period searched, to 525 days, which is the upper limit of achievable periods given the length of the data set and the requirement that all detections include at least three transits. The detected signals are compared to a set of known transit events in the Kepler field of view, many of which were identified by alternative methods; the comparison shows that the current search recovery rate for targets with known transit events is 98.3%.

79 ASTRONOMY AND ASTROPHYSICS↗

CONGO²: Scalable Online Anomaly Detection and Localization in Power Electronics Networks

Rapid and accurate detection and localization of electronic disturbances simultaneously are important for preventing its potential damages and determining potential remedies. Existing anomaly detection methods are severely limited by the low accuracy, the expensive computational cost and the need for highly trained personnel. There is an urgent need for a scalable online algorithm for in-field analysis of large-scale power electronics networks. Here in this paper, we propose a fast and accurate algorithm for anomaly detection and localization of power electronics networks: stratified colored-node graph (CONGO2). This algorithm hierarchically models the change of correlated waveforms and then correlated sensors using the colored-node graph. By aggregating the change of each sensor with its neighbors’ inputs, we can spontaneously identify and localize the anomaly that cannot be detected by data collected from a single sensor. As our proposed method only focuses on the changes within a short time frame, it is highly computational efficient and only needs small data storage. Thus, our method is ideal for online and reliable anomaly detection and localization of large-scale power electronic networks. Compared to existing anomaly detection methods, our method is entirely data-driven without training data, highly accurate and reliable for wide-spectrum anomalies detection, and more importantly, capable of both detection and localization. Thus, it is ideal for infield deployment for large-scale power electronic networks. As illustrated by a distributed energy resources (DERs) power grid with 37-node, our method can effectively detect and localize various cyber and physical attacks.

42 ENGINEERING↗

MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection

Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold seeds are either correctly detected or a warning is raised for further manual intervention.

60 APPLIED LIFE SCIENCES↗

Indirectly detected chemical shift correlation NMR spectroscopy in solids under fast magic angle spinning

The development of fast magic angle spinning (MAS) opened up an opportunity for the indirect detection of insensitive low-γ nuclei (e.g., 13 C and 15 N) via the sensitive high-{gamma} nuclei (e.g., 1 H and 19 F) in solid-state NMR, with advanced sensitivity and resolution. In this thesis, new methodology utilizing fast MAS is presented, including through-bond indirectly detected heteronuclear correlation (HETCOR) spectroscopy, which is assisted by multiple RF pulse sequences for 1 H- 1 H homonuclear decoupling. Also presented is a simple new strategy for optimization of 1 H- 1 H homonuclear decoupling. As applications, various classes of materials, such as catalytic nanoscale materials, biomolecules, and organic complexes, are studied by combining indirect detection and other one-dimensional (1D) and two-dimensional (2D) NMR techniques. Indirectly detected through-bond HETCOR spectroscopy utilizing refocused INEPT (INEPTR) mixing was developed under fast MAS (Chapter 2). The time performance of this approach in 1 H detected 2D 1 H{l_brace} 13 C{r_brace} spectra was significantly improved, by a factor of almost 10, compared to the traditional 13 C detected experiments, as demonstrated by measuring naturally abundant organic-inorganic mesoporous hybrid materials. The through-bond scheme was demonstrated as a new analytical tool, which provides complementary structural information in solid-state systems in addition to through-space correlation. To further benefit the sensitivity of the INEPT transfer in rigid solids, the combined rotation and multiple-pulse spectroscopy (CRAMPS) was implemented for homonuclear 1 H decoupling under fast MAS (Chapter 3). Several decoupling schemes (PMLG5 m $\bar{x}$ , PMLG5 mm $\bar{x}$x and SAM3) were analyzed to maximize the performance of through-bond transfer based on decoupling efficiency as well as scaling factors. Indirect detection with assistance of PMLG m $\bar{x}$ during INEPTR transfer proved to offer the highest sensitivity gains of 3-10. In addition, the CRAMPS sequence was applied under fast MAS to increase the 1 H resolution during t 1 evolution in the traditional, 13 C detected HETCOR scheme. Two naturally abundant solids, tripeptide N-formyl-L-methionyl-L-leucyl-L-phenylalanine (f-MLF-OH) and brown coal, with well ordered and highly disordered structures, respectively, are studied to confirm the capabilities of these techniques. Concomitantly, a simple optimization of 1 H homonuclear dipolar decoupling at MAS rates exceeding 10 kHz was developed (Chapter 4). The fine-tuned decoupling efficiency can be obtained by minimizing the signal loss due to transverse relaxation in a simple spin-echo experiment, using directly the sample of interest. The excellent agreement between observed decoupling pattern and earlier theoretical predictions confirmed the utility of this strategy. The properties of naturally abundant surface-bound fluorocarbon groups in mesoporous silica nanoparticles (MSNs) were investigated by the above-mentioned multidimensional solid-state NMR experiments and theoretical modeling (Chapter 5). Two conformations of (pentafluorophenyl)propyl groups (abbreviated as PFP) were determined as PFP-prone and PFP-upright, whose aromatic rings are located above the siloxane bridges and in roughly upright position, respectively. Several 1D and 2D NMR techniques were implemented in the characterizations, including indirectly detected 1 H{l_brace} 13 C{r_brace} and 19 F{l_brace} 13 C{r_brace} 2D HETCOR, Carr-Purcell-Meiboom-Gill (CPMG) assisted 29 Si direct polarization and 29 Si 19 F 2D experiments, 2D double-quantum (DQ) 19 F MAS NMR spectra and spin-echo measurements. Furthermore, conformational details of two types of PFP were confirmed by theoretical calculation, operated by Dr. Takeshi Kobayashi. Finally, the arrangement of two surfactants, cetyltrimetylammoium bromide (CTAB) and cetylpyridinium bromide (CPB), mixed inside the MSN pores, was studied by solid-state NMR (Chapter 6). By analyzing the 1 H- 1 H DQMAS and NOESY correlation spectra, the CTAB and CPB molecules were shown to co-exist inside the pores without forming significant monocomponent domains. A 'folded-over' conformation of CPB headgroups was proposed according to the results from 1 H- 29 Si 2D HETCOR.

01 COAL, LIGNITE, AND PEAT↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards deep computer vision for in-line defect detection in polymer electrolyte membrane fuel cell materials

Polymer Electrolyte Membrane (PEM) fuel cells are a promising source of alternative energy. However, their production is limited by a lack of well-established methods for quality control of their constituent materials like the membrane-electrode assembly during roll-to-roll manufacturing. One potential solution is the implementation of deep learning methods to detect unwanted defects through their detection in scanned images. Here we explore the detection of defects like scratches, pinholes, and scuffs in a sample dataset of PEM optical images using two deep learning algorithms: Patch Distribution Modeling (PaDiM) for unsupervised anomaly detection and Faster-RCNN for supervised object detection. Both methods achieve scores on performance metrics (ROC-AUC and PRO-AUC for PaDiM and AP for Faster-RCNN) that are comparable to their scores on benchmark datasets. These methods also have the potential to detect a wider range of defects compared to IR thermography and previous optical inspection methods. Overall, deep learning shows promise at detecting relevant defects of interest and has the potential to achieve real-time defect detection.

30 DIRECT ENERGY CONVERSION↗

Diffusion-weighted imaging as a part of PET/MR for small lesion detection in patients with primary abdominal and pelvic cancer, with or without TOF reconstruction technique

Objectives: To investigate the value of diffusion-weighted imaging (DWI) in detection of small lesions (≤ 10 mm) in patients with primary abdominal and pelvic cancer in hybrid PET/MR with or without time-of-flight (TOF) technique. Materials and methods: Twenty patients (11 females and 9 males, mean age 67.23 ± 12.90 years) with histologically confirmed primary abdominal and pelvic cancer underwent hybrid PET/MR examination. A total of 64 small lesions were included in this study, which were divided into two groups (≤ 10 mm and 10–30 mm). Visual scores of small lesion detection ability were rated by five-point ordinal scale. The visual scores and detectability of small lesions on TOF PET image, noTOF PET image, and DWI sequences of hybrid PET/MR examination with or without TOF technique were analyzed. Logistic regression model was established for analysis in the value of DWI in hybrid PET/MR examination with or without TOF technique in detection of the small lesions between two groups. Results: The visual evaluation revealed the small lesion (≤ 10 mm) visual scores of DWI (mean ± SD: 4.23 ± 1.41), TOF PET image (mean ± SD: 4.14 ± 0.89), and noTOF PET image (mean ± SD: 2.68 ± 1.13);.and the visual scores of small lesions (10–30 mm) on DWI (mean ± SD: 4.98 ± 0.15), TOF PET image (mean ± SD: 4.57 ± 0.59), and noTOF PET image (mean ± SD: 3.98 ± 1.05). The visual scores of all small lesions on DWI were higher than that on TOF PET data and noTOF PET data in both two groups (**P < 0.01). The missed diagnosis rates of small FDG avid lesions (≤ 10 mm) of DWI and noTOF PET image were 9.1% and 9.1%, respectively. However, the TOF PET-based clinical diagnosis detected all small lesions (≤ 30 mm). DWI was of great importance in detection of small lesions (≤ 10 mm) in the absence of TOF technique in PET/MR examination (**P < 0.01). DWI’s effect on detection of small lesions(10-30 mm) has shown no difference between PET/MR examinations with TOF and without TOF techniques (P > 0.05). Conclusion: DWI has significant value in the detection of small lesions (≤ 10 mm) in hybrid PET/MR examination without TOF technique for patients with primary abdominal and pelvic cancer. However, it had less detection benefits in the small lesions (≤ 10 mm) in hybrid PET/MR examination with TOF PET image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding and quantifying the systematic effects of clutter within a radiation detection scene

Because of low signal-to-noise ratios, the main difficultly in real-world detection scenarios is distinguishing between benign sources and potentially-threatening radioactive materials. The variability in observed signal during a radiation detection search operation can be contributed to the stochastic nature of the underlying physics and the systematic errors inherent to the detection systems employed. This variability is compounded for dynamic detection scenarios, where objects, referred to as clutter, traverse through the primary detection scene, introducing potential suppressions in the observed signal due to the attenuation of background radiation. This study examines the impact that clutter, namely automobiles such as small utility vehicles, sedans, and trucks, produces on the observed signal in a 2 in. × 4 in. × 16 in. NaI(Tl) detector. The clutter is identified and tracked in the detection scene using a time-synced video camera and a 2-D light distance and ranging contextual sensors. Two experiments were performed on the Oak Ridge National Laboratory reservation: one using a distributed source within the scene to understand the systematics of detecting and analyzing the clutter, and the second experiment mimicking an urban environment with large buildings positioned on either side of a roadway. The experiments exhibited unique results in the amount of signal suppression and variability of the cluttered signal, both demonstrating an observable suppression from the clutter-free background. These results reveal a new potential category of signal noise intrinsic to real-world detection scenarios that should be considered when establishing detection thresholds based on expected values.

Stewart, Ian R.↗

Advancing Li-plating detection: Motivating a multi-signal correlation approach

Facilitating fast charging in lithium-ion batteries (LiBs) is often linked to Li-plating, which harms performance, longevity, and safety. Early detection of Li-plating is essential for rapid technological development and for preventing performance deterioration and ensuring safety during operation. Fast and real-time detection, using commonly collected measurements like voltage (V), current (I), temperature (T), and pressure (P), is highly desirable. Existing standalone methods relying on electrochemical and mechanical signatures, using half, smaller, or specially designed cells often operated at lower temperatures, fail to account for real-world fast-charging conditions. These signatures may also have inherent unreliability in aged LiBs, a phenomenon currently not-well understood. All these uncertainties have complicated practical implementation of a robust Li-plating detection technique. This study, through multiple case studies involving real-world fast-charging conditions using automotive-grade 11.6 Ah LiBs, shows that many single signal-based diagnostic techniques may be inadequate to detect Li-plating. Among various signatures, end-of-charge rest pressure, differential pressure-sensing, and end-of-charge rest voltage were identified as particularly useful in detecting Li-plating. Furthermore, A multi-signal-based detection technique is shown to be more robust in detecting Li-plating. Using both fresh and aged cells, the results and analysis highlight how detection capabilities are influenced by various factors, including battery design, size, charging speed, operating temperature, and degradation level. Adopting such a multi-signal Li-plating detection approach may be instrumental in the rapid development of battery technology in laboratories, as well as ensuring the enhanced safety of next-generation LiBs in real-world fast-charging applications.

25 ENERGY STORAGE↗

Analysis of sensitivity and rapid hybridization of a multiplexed Microbial Detection Microarray

Microarrays have proven to be useful in rapid detection of many viruses and bacteria. Pathogen detection microarrays have been used to diagnose viral and bacterial infections in clinical samples and to evaluate the safety of biological drug materials. A multiplexed version of the Lawrence Livermore Microbial Detection Array (LLMDA) was developed and evaluated with minimum detectable concentrations for pure unamplified DNA viruses, along with mixtures of viral and bacterial DNA subjected to different whole genome amplification protocols. In addition the performance of the array was tested when hybridization time was reduced from 17 h to 1 h. The LLMDA was able to detect unamplified vaccinia virus DNA at a concentration of 14 fM, or 100,000 genome copies in 12 μL of sample. With amplification, positive identification was made with only 100 genome copies of input material. When tested against human stool samples from patients with acute gastroenteritis, the microarray detected common gastroenteritis viral and bacterial infections such as rotavirus and E. coli. Accurate detection was found but with a 4-fold drop in sensitivity for a 1 h compared to a 17 h hybridization. The array detected 2 ng (equivalent concentration of 15.6 fM) of labeled DNA from a virus with 1 h hybridization without any amplification, and was able to identify the components of a mixture of viruses and bacteria at species and in some cases strain level resolution. Sensitivity improved by three orders of magnitude with random whole genome amplification prior to hybridization; for instance, the array detected a DNA virus with only 20 fg or 100 genome copies as input. This multiplexed microarray is an efficient tool to analyze clinical and environmental samples for the presence of multiple viral and bacterial pathogens rapidly.

59 BASIC BIOLOGICAL SCIENCES↗

INR-TEM: Robust cavity detection in multifocus TEM images via implicit neural representations

When characterizing materials using transmission electron microscopy (TEM) images, detecting and quantifying small features in microstructures, such as cavities, pose significant challenges. Off-the-shelf object detection models, including YOLOv8, show considerable performance degradation, particularly when images vary in resolution and the objects of interest possess a low percentage of the total image region of interest. In this study, we introduce a novel detection pipeline that incorporates an implicit neural representation (INR)-based detection method, INR-TEM, and two-modality imaging (e.g., under-focused and over-focused images typically acquired during materials characterization) to improve object detection performance. The INR-TEM method incorporates a pixel-wise prediction principle inspired by pixel-wise centerness weighting. INR-TEM demonstrates superior robustness to resolution variability, maintaining high detection accuracy even at low image resolutions compared to YOLOv8. To leverage INR-TEM effectively in real-world two-modality characterization applications, we further integrate a two-stage motion correction pipeline designed explicitly for aligning multifocus TEM images. The alignment process, comprising keypoint (based on scale-invariant feature transform, SIFT) and intensity matching, significantly mitigates the adverse effects of perceived motion-induced image degradation during through-focal TEM imaging, directly enhancing INR-TEM’s detection capability over conventional single-focus images. Our integrated INR-TEM cavity detection framework notably improves performance across various cavity sizes, outperforming off-the-shelf YOLOv8 detections that rely on a single image modality.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasible voltage-tap based quench detection in a Ag/Bi-2212 coil enabled by fast 3D normal zone propagation

For this study, small insert solenoids have been built using a commercial Ag/Bi-2212 multifilamentary round wire, insulated with a new thin TiO 2 – polymer coating insulation (thickness in ~20 μm versus ~100 μm for a commonly used mullite braided sleeve insulation), and characterized in background magnetic field up to 14 T at 4.2 K to explore the high-field performance and quench detection of Bi-2212 magnets. The coil has no visible leakage and no electrical shorts after reaction, and it carries 280 A/mm -2 in a background field 14 T and generates an additional 1.7 T. A notable result is that, despite normal zones propagate slowly along the conductor, the hot spot temperature upon detection increases only from 40 K to 60 K when the resistive quench detection voltage threshold increases from 0.1 V to 1 V for all operating current density investigated, showing that quench detection using voltage taps is feasible for this coil. This is in a strong contrast to a coil we previously built to the same specifications but from wires insulated with the mullite braided sleeve insulation, for which the hot spot temperature upon detection increases from ~80 K to ~140 K while increasing from the detection voltage threshold from 0.1 V to 1 V, and thus for which quench detection using voltage taps presents significant risks, consistent with the common belief that the effectiveness of quench detection using voltage taps for superconducting magnets built using high temperature superconductors is seriously compromised by their slow normal zone propagation. This striking difference is ascribed to the fast transverse quench propagation enabled by thin insulation and improved thermal coupling between conductor turns. Finally, this work demonstrates that quench detection for high-temperature superconducting magnets highly depends on the design and construction of the coils such as insulation materials used and this dependence should be factored into the overall magnet design.

36 MATERIALS SCIENCE↗

Bose-Einstein-condensed scalar field dark matter and the gravitational wave background from inflation: New cosmological constraints and its detectability by LIGO

Here, we consider an alternative to weakly interacting massive particle (WIMP) cold dark matter (CDM), ultralight bosonic dark matter ($m$ ≳ 10 -22 eV /$c$ 2 ) described by a complex scalar field (SFDM) with a global $U(1)$ symmetry, for which the comoving particle number density, or charge density, is conserved after particle production during standard reheating. We allow for a repulsive self-interaction. In a Λ SFDM universe, SFDM starts relativistic, evolving from stiff ($w$ = 1) to radiation-like ($w$ = 1/3), before becoming nonrelativistic at late times ($w$ = 0). Thus, before the familiar radiation-dominated era, there is an earlier era of stiff-SFDM-domination. During both the stiff-SFDM-dominated and radiation-dominated eras, the expansion rate is higher than in Λ CDM. SFDM particle mass $m$ and quartic self-interaction coupling strength λ, are therefore constrained by cosmological observables, particularly $N$ eff , the effective number of neutrino species during big bang nucleosynthesis, and $z$ eq , the redshift of matter-radiation equality. Furthermore, since the stochastic gravitational wave background (SGWB) from inflation is amplified during the stiff-SFDM-dominated era, it can contribute a radiationlike component large enough to affect these observables, by further boosting the expansion rate after the stiff era ends. Remarkably, this same amplification makes detection of the SGWB possible at high frequencies by current laser interferometer experiments, e.g., aLIGO/Virgo and LISA. For SFDM particle parameters that sat isfy these cosmological constraints, the amplified SGWB is detectable by LIGO for a broad range of reheat temperatures $T$ reheat , for values of the tensor-to-scalar ratio $r$ currently allowed by CMB polarization measurements. For a given $r$ and λ/(mc 2 ) 2 , the marginally allowed Λ SFDM model for each $T$ reheat has the smallest $m$ that satisfies the cosmological constraints and maximizes the present SGWB energy density for that $T$ reheat . This SGWB is then maximally detectable for values of $T$ reheat for which modes that reenter the horizon when reheating ended have frequencies today that lie within the LIGO sensitive band. For example, for the family of marginally allowed models with $r$ = 0.01 and λ/($mc$ 2 ) 2 = 10 -18 eV -1 cm 3 , the maximally detectable Λ SFDM model has $T$ reheat ≃ 2×10 4 GeV and $m$ ≃ 1.6×10 -19 eV/c 2 , for which we predict an aLIGO O1 run detection with signal-to-noise ratio of ~ 10. We show that the null detection of the SGWB recently reported by the aLIGO O1 run excludes the parameter range 8.75 × 10 3 ≲ $T$ reheat (GeV) ≲ 1.7 × 10 5 for this illustrative family at 95% confidence, thereby demonstrating that GW detection experiments can already place a new kind of cosmological constraint on SFDM. A wider range of SFDM parameters and reheat temperatures should be accessible to aLIGO/Virgo O5, with the potential to detect this unique signature of the ΛSFDM model. For this same illustrative family, for example, a 3σ detection is predicted for 600 ≲ $T$ reheat (GeV) ≲ 10 7 .

79 ASTRONOMY AND ASTROPHYSICS↗

Regression for Radioactive Source Detection

Detection of radioactive sources is an important capability that led to the deployment of networks for detecting and localizing low-level, hazardous radiation sources. It is generally expected that such networks outperform the individual detectors by intelligently fusing information from several dispersed sensors. In this paper, we develop a network detection method that uses the slope of a linear regression fit as a test statistic for detecting a point radioactive source within a field of detectors. In our regression model, we compute a least-squared linear fit between the average radiation counts at the detectors and the inverse-squared distances of known detector locations to an estimated source location. We show that the slope of this regression fit is an estimate of the source intensity and can be used as a threshold for source detection purposes. We compare performance of our proposed detection method with that of a fusion-based Sequential Probability Ratio Test (SPRT) method. For performance analyses, two datasets from the Domestic Nuclear Detection Ofces Intelligence Radiation Sensors Systems (IRSS) outdoor tests are used. Each of these tests consists of several runs of a single radioactive source moving in and out of a detector network. We present receiver operating characteristic (ROC) curves and optimal threshold values for the performance each detection method, and determine that our detection method using linear regression fit has slightly better overall performance than SPRT method.

Cordone, G.↗

Towards Malware Detection via CPU Power Consumption: Data Collection Design and Analytics

This paper presents an experimental design and data analytics approach aimed at power-based malware detection on general-purpose computers. Leveraging the fact that malware executions must consume power, we explore the postulate that malware can be accurately detected via power data analytics. Our experimental design and implementation allow for programmatic collection of CPU power profiles for fixed tasks during uninfected and infected states using five different rootkits. To characterize the power consumption profiles, we use both simple statistical and novel, sophisticated features. We test a one-class anomaly detection ensemble (that baselines non-infected power profiles) and several kernel-based SVM classifiers (that train on both uninfected and infected profiles) in detecting previously unseen malware and clean profiles. The anomaly detection system exhibits perfect detection when using all features and tasks, with smaller false detection rate than the supervised classifiers. The primary contribution is the proof of concept that baselining power of fixed tasks can provide accurate detection of rootkits. Moreover, our treatment presents engineering hurdles needed for experimentation and allows analysis of each statistical feature individually. This work appears to be the first step towards a viable power-based detection capability for general-purpose computers, and presents next steps toward this goal.

Bridges, Robert↗

Soft-tissue detectability in cone-beam CT: Evaluation by 2AFC tests in relation to physical performance metrics

Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal planes, and the effect of prior knowledge on detectability. Custom-built phantoms ({approx}15 cm diameter cylinders) containing soft-tissue-simulating spheres of variable contrast and diameter were imaged on an experimental CBCT bench. The proportion of correct responses (P{sub corr}) in 2AFC tests was analyzed as a figure of merit, ideally equal to the area under the receiver operating characteristic curve. P{sub corr} was evaluated as a function of the sphere diameter (1.6-12.7 mm), contrast (20-165 HU), dose (1-7 mGy), plane of visualization (axial/sagittal), apodization filter (Hanning and Ram-Lak), and prior knowledge provided to the observer [ranging from stimulus known exactly (SKE) to stimulus unknown (SUK)]. Detectability limits were characterized in terms of the dose required to achieve a given level of P{sub corr} (e.g., 70%). For example, a 20 HU stimulus of diameter down to {approx}6 mm was detected with P{sub corr} 70% at dose {>=}2 mGy. Detectability tended to be greater in axial than in sagittal planes, an effect amplified by sharper apodization filters in a manner consistent with 3D NPS asymmetry. Prior knowledge had a marked influence on detectability - e.g., P{sub corr} for a {approx}6 mm(20 HU) sphere was {approx}55%-65% under SUK conditions, compared to {approx}70%-85% for SKE conditions. Human observer tests suggest practical implications for implementation of CBCT: (i) Detectability limits help to define minimum-dose imaging techniques for specific imaging tasks; (ii) detectability of a given structure can vary between axial and sagittal/coronal planes, owing to the spatial-frequency content of the 3D NPS in relation to the imaging task; and (iii) performance under SKE conditions (e.g., image guidance tasks in which lesion characteristics are known) is maintained at a lower dose than in SUK conditions (e.g., diagnostic tasks in which lesion characteristics are unknown)

62 RADIOLOGY AND NUCLEAR MEDICINE↗