Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

In situ high-temperature Raman spectroscopy for online EAF slag analysis

Real-time monitoring of slag chemistry is critical for optimizing Electric Arc Furnace (EAF) steelmaking operations, where dynamic variations in slag composition directly influence slag foaming, refractory degradation, and thermal efficiency. Conventional techniques such as X-ray fluorescence (XRF), Fourier-transform infrared (FTIR), and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDS) are commonly used to analyze slag composition, but their offline nature and equipment constraints limit their applicability for online monitoring in harsh industrial environments. To address this challenge, we present an in situ, high-temperature analytical approach that integrates Raman spectroscopy with a custom designed fiber-optic probe for real-time slag characterization at 1550 °C. The system enables non destructive spectral acquisition from molten slags, providing molecular-level insights into silicate polymerization and iron oxidation states. Eight synthetic slag samples were evaluated, and key Raman features—such as Q n silicate units and FeO₄/FeO₆ coordination environments—were identified and quantitatively correlated with slag basicity and Fe₂O₃ content. The results demonstrate agreement between Raman spectral ratios and bulk slag chemistry, validating the method’s capability to track compositional and structural changes under molten temperature. This work establishes the feasibility of deploying fiber-optic Raman probe for online EAF slag monitoring and highlights their potential to support closed-loop control strategies, thereby enhancing process stability, refractory protection, and steel quality in industrial steelmaking applications.

47 OTHER INSTRUMENTATION↗

NBC boil-off calorimeter for measuring thermal conductivity of insulating materials

Modern temperature, pressure and flow sensors along with a high speed digital control system have been incorporated into an existing thermal conductivity apparatus (ASTM C745). The system has also been modified to include the use of liquid helium as the refrigerant, if desired. The apparatus can be used to study thermal conductivity in the temperature range from 4 K to room temperature. Preliminary results on insulating materials indicate that the system update has significantly improved the precision and operational characteristics of the apparatus. Basic principles of operation, sources of system error and the reduction of system error by application of digital control and modern sensors are discussed. Preliminary data are presented.

Dube, W. P.↗

Mitigating humidity interference in chemiresistive hydrogen sensors through hydrophobic surface functionalization

Chemiresistive gas sensors based on semiconductor metal oxides, such as tin dioxide (SnO₂), are indispensable for detecting and monitoring toxic gases and pollutants, making them critical components in industrial and environmental applications. To enhance their performance, the metal oxides are loaded with noble metals such as palladium (Pd). However, ambient humidity poses a significant challenge to their performance. The presence of adsorbed water molecules on the oxide surface can considerably impair sensor sensitivity and overall performance. To address this issue, in this paper, we report on the application of an ultrathin, hydrophobic layer of hexamethyldisilazane to the surface of a Pd/SnO 2 sensor. This study investigates the influence of hydrophobic surface modifications on the metal oxide interface, focusing on their impact on sensor sensitivity and selectivity. The resulting sensor exhibits superior hydrogen sensing capabilities, operating effectively at low temperatures even in high humidity environments. Furthermore, the hydrophobic modification reduces the sensor’s susceptibility to interfering gases, thus enhancing its selectivity. The combined enhancements in moisture resistance and selectivity achieved through HMDS surface modification, along with the superior sensitivity of Pd/SnO₂ sensors, facilitate the development of gas sensors with enhanced humidity tolerance and broader applications.

Chemiresistive gas sensors↗

Unravelling the sintering temperature-induced phase transformations in Ba(Fe 0.7 Ta 0.3 )O 3-δ ceramics

This work reports on the fundamental details of the crystal structure and phase transformations in Ba(Fe 0.7 Ta 0.3 )O 3-δ , the best known temperature-independent oxygen-sensing ceramic material for applications in extreme environments. Ba(Fe 0.7 Ta 0.3 )O 3-δ ceramics were synthesized using conventional solid-state ceramic reaction under variable sintering temperatures (T s = 1200–1350 °C). Combined X-ray diffraction (XRD) and high-resolution transmission electron microscopy (TEM) measurements revealed the T s -induced phase transformations and their origin in Ba(Fe 0.7 Ta 0.3 )O 3-δ . Associated with phase transformations, pseudo-cubic (PC) reflections, such as {200} PC , {211} PC , and {220} PC , exhibited distinct anomalies with increasing T s . At T s = 1200 °C, Ba(Fe 0.7 Ta 0.3 )O 3-δ stabilized in mixed orthorhombic + rhombohedral phases (Amm2 + R3m). With increasing T s (≥1250 °C), Ba(Fe 0.7 Ta 0.3 )O 3-δ ceramics stabilized in tetragonal/rhombohedral [P4mm + R3m] mixed phases, while variations in the quantity of the respective phases were observed. Because both structure and crystal chemistry play key roles in achieving enhanced performance in chemical sensing and catalytic converters, detailed understanding of the phase transformations and crystal structure of Ba(Fe 0.7 Ta 0.3 )O 3-δ ceramics, as derived in this work, will be useful to develop chemical sensors with optimum performance for high-temperature and corrosive environments.

36 MATERIALS SCIENCE↗

One-Step Ahead Prediction of Thermal Mixing Tee Sensors with Long Short Term Memory (LSTM) Neural Networks

High-temperature advanced reactors under development, such as sodium fast reactors (SFR) and molten salt cooled reactors (MSCR), are expected to offer lower levelized cost of energy (LCOE) compared to existing light water reactor (LWR’s). In the existing light water reactors (LWR’s), operation and maintenance (O&M) expenses constitute the largest fraction of the total operating cost. Some of the O&M costs are related maintenance of sensors which can fail due to exposure to harsh environment in a reactor. The O&M costs of Advanced Reactor (AR)’s are expected to constitute a significant fraction of the total cost as well, because of high temperature and radiation level in AR are likely to cause material fatigue and premature failure of sensors and components. The O&M costs in AR’s could be reduced through integration of advanced informatics of performance-related sensors into a digital twin designed for reactor monitoring. For example, machine learning (ML) could be employed for real-time validation and correction of performance-related sensors, and reducing the number of performance-related physical sensor units through virtual sensing. As part of the effort, we investigate real-time validation of thermal hydraulic sensors through one-step ahead forecasting of sensor values using long short-term memory (LSTM) recurrent neural networks (RNN). The sensors are installed in a flow loop containing a thermal mixing tee, which is a common experimental model to study thermal fatigue in a thermal hydraulic loop. In addition, nonlinear transients generated in a thermal mixing tee constitute a good challenge data set for training and validation of ML algorithms. Sensors in this study include thermocouples, flow meters, and optical fibers for distributed temperature sensing. In one experiment, measurement data sets were obtained for a loop was filled with water, and in another experiment, measurements were performed on a loop filled with liquid metal Galinstan. We have also conducted preliminary investigation of one-step ahead prediction of fiber optics-based distributed temperature sensing with LSTM networks. In predicting fiber-based temperature measurements, we treated each gauge pitch of the fiber as an independent sensor. Accuracy of one-step ahead forecasting was estimated by calculating root mean square error (RMSE) for the test segment of time series of each sensor. RMSE’s for temperature sensors in water loop were, for the most part, lower than for the same sensors in Galinstan loop. The RMSE’s for flow meters were similar for both loops. The RMSE’s for distributed temperature measured with the fiber optic sensor were similar to those of the point sensors. Results of this study demonstrated the capability of LSTM one-step ahead forecasting with RMSE comparable to uncertainty in sensor measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Superconducting gamma and fast-neutron spectrometers with high energy resolution

Superconducting Gamma-ray and fast-neutron spectrometers with very high energy resolution operated at very low temperatures are provided. The sensor consists of a bulk absorber and a superconducting thermometer weakly coupled to a cold reservoir, and determines the energy of the incident particle from the rise in temperature upon absorption. A superconducting film operated at the transition between its superconducting and its normal state is used as the thermometer, and sensor operation at reservoir temperatures around 0.1 K reduces thermal fluctuations and thus enables very high energy resolution. Depending on the choice of absorber material, the spectrometer can be configured either as a Gamma-spectrometer or as a fast-neutron spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Micro-Pocket Fission Detector for High Temperature Reactors - FY17 FInal Project Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core fission chambers and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for this three year project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance optimization of apodized FBG-based temperature sensors in single and quasi-distributed DWDM systems with new and different apodization profiles

In this work, different FBG temperature sensors are designed and evaluated with various apodization profiles. Evaluation is done under a wide range of controlling design parameters like sensor length and refractive index modulation amplitude, targeting a remarkable temperature sensing performance. New judgment techniques are introduced such as apodization window roll-off rate, asymptotic sidelobe (SL) decay level, number of SLs, and average SL level (SLav). Evaluation techniques like reflectivity, Full width at Half Maximum (FWHM), and Sidelobe Suppression Ratio (SLSR) are also used. A “New” apodization function is proposed, which achieves better performance like asymptotic decay of 18.4 dB/nm, high SLSR of 60 dB, high channel isolation of 57.9 dB, and narrow FWHM less than 0.15 nm. For a single accurate temperature sensor measurement in extensive noisy environment, optimum results are obtained by the Nuttall apodization profile and the new apodization function, which have remarkable SLSR. For a quasi-distributed FBG temperature sensor the Barthann and the new apodization profiles obtain optimum results. Barthann achieves a high asymptotic decay of 40 dB/nm, a narrow FWHM (less than 25 GHZ), a very low SLav of −45.3 dB, high isolation of 44.6 dB, and a high SLSR of 35 dB. The new apodization function achieves narrow FWHM of 0.177 nm, very low SL of −60.1, very low SLav of −63.6 dB, and very high SLSR of −57.7 dB. A study is performed on including an unapodized sensor among apodized sensors in a quasi-distributed sensing system. Finally, an isolation examination is performed on all the discussed apodizations and a linear relation between temperature and the Bragg wavelength shift is observed experimentally and matched with the simulated results.

36 MATERIALS SCIENCE↗

Development of sensors for ceramic components in advanced propulsion systems: Survey and evaluation of measurement techniques for temperature, strain and heat flux for ceramic components in advanced propulsion systems

The report presents the final results of Tasks 1 and 2, Development of Sensors for Ceramic Components in Advanced Propulsion Systems (NASA program NAS3-25141). During Task 1, an extensive survey was conducted of sensor concepts which have the potential for measuring surface temperature, strain and heat flux on ceramic components for advanced propulsion systems. Each sensor concept was analyzed and evaluated under Task 2; sensor concepts were then recommended for further development. For temperature measurement, both pyrometry and thermographic phosphors are recommended for measurements up to and beyond the melting point of ceramic materials. For lower temperature test programs, the thin-film techniques offer advantages in the installation of temperature sensors. Optical strain measurement techniques are recommended because they offer the possibility of being useful at very high temperature levels. Techniques for the measurement of heat flux are recommended for development based on both a surface mounted sensor and the measurement of the temperature differential across a portion of a ceramic component or metallic substrate.

Atkinson, W. H.↗

Thick Films acoustic sensors devoted to MTR environment measurements. Thick Films acoustic sensors devoted to Material Testing Reactor environment measurements

The development of advanced instrumentation for in-pile experiments in Material Testing Reactor constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. An acoustic method for fission gas release detection was tested with success during a first experiment called REMORA 3 in 2010 and 2011, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). The maximal temperature on the sensor during the irradiation was about 150 deg. C. In this paper we present a thick film transducer produce by screen printing process. The screen printing of piezoelectric offers a wide range of possible applications for the development of acoustic sensors and piezoelectric structure for measurements in high temperature environment. We firstly produced a Lead Zirconate Titanate (PZT) based paste composed of Pz27 powder from Ferroperm, CF7575 glass, and organic solvent ESL 400. Likewise a Bismuth Titanate based paste synthesized in our laboratory was produced. With these inks we produced thick film up to 130 μm by screen printing process. Material properties characterizations of these thick-film resonators are essential for device design and applications. The piezoelectric coefficients d33 and pyro-electric P(T) coefficient are investigated. The highest P(T) and d33 are respectively 80 μC.m{sup -2}.K{sup -1} and 130 μC.N{sup -1} for the PZT transducer -which validates the fabrication process-. In view of the development of this transducer oriented for high temperature and irradiation environment, we investigated the electrical properties of the transducers for different ranges of frequencies and temperature - from 20 Hz up to 40 MHz between 30 and 400 deg. C. We highlight the evolution of the impedance response and piezoelectric parameters of screen printed piezoelectric structures on alumina. Shortly an irradiation will be realized in order to investigate their reliability towards neutron fluence. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multiple Waveband Temperature Sensor (MWTS)

This slide presentation reviews the development of Multiple Waveband Temperature Sensor (MWTS). The MWTS project will result in a highly stable, monolithically integrated, high resolution infrared detector array sensor that records registered thermal imagery in four infrared wavebands to infer dynamic temperature profiles on a laser-irradiated ground target. An accurate surface temperature measurement of a target in extreme environments in a non-intrusive manner is required. The development challenge is to: determine optimum wavebands (suitable for target temperatures, nature of the targets and environments) to measure accurate target surface temperature independent of the emissivity, integrate simultaneously readable multiband Quantum Well Infrared Photodetectors (QWIPs) in a single monolithic focal plane array (FPA) sensor and to integrate the hardware/software and system calibration for remote temperature measurements. The charge was therefore to develop and demonstrate a multiband infrared imaging camera with the detectors simultaneously sensitive to multiple distinct color bands for front surface temperature measurements Wavelength ( m) measurements. Amongst the requirements are: that the measurement system will not affect target dynamics or response to the laser irradiation and that the simplest criterion for spectral band selection is to choose those practically feasible spectral bands that create the most contrast between the objects or scenes of interest in the expected environmental conditions. There is in the presentation a review of the modeling and simulation of multi-wave infrared temperature measurement and also a review of the detector development and QWIP capacities.

infrared photodector↗

Capacitance-Based Dimensional Change Sensors for In-Pile Materials Measurements

Advanced fuel compositions, such as accident tolerate fuels (ATF), are an active area of developing in the nuclear power industry. The long-term performance of these newly developed fuels is estimated through physics-based simulation models of irradiation-, temperature-, pressure-, etc.-induced material degradation. As these fuels are deployed in test reactors, measurement and characterization of the fuel pin evolution is used to validate prediction models. In-pile material evolution parameters, such as fuel rod pressurization, fuel stack and cladding elongation, and cladding diameter, are commonly measured using a linear voltage differential transformer (LVDT). However, LVDTs are bulky and limited to lower (350-500C) temperature operation. The high power density and small size of most experimental positions in high performance research reactors used for accelerated materials irradiation studies generally precludes the use of LVDTs in these reactors. There is a critical need for sensors that provide real-time data regarding material evolution under highly accelerated irradiation. These sensors would ideally have a small profile and the ability to withstand irradiation at extremely high dose rates and temperatures for extended periods of time. A capacitance-based sensor is currently under development at the University of Tennessee to provide a direct measurement of in-pile dimensional change during irradiation. Sensor response was simulated using AutoCAD Electromagnetic field simulator (EMS) for a variety of sensor materials and configurations and fuel pin swelling conditions. Initial results of these simulations are summarized and areas of ongoing research and development are discussed.

Naughton, Tyler↗

300°C Capable Electronics Platform and Temperature Sensor System For Enhanced Geothermal Systems (Final Technical Report)

A silicon carbide (SiC) based electronic temperature sensor prototype has been demonstrated to operate at 300°C. We showed continuous operation of 1,000 hours with SiC operational amplifier and surface mounted discreet resistors and capacitors on a ceramic circuit board. This feasibility demonstration is a major milestone in the development of high temperature electronics in general and high temperature geothermal exploration and well management tools in particular. SiC technology offers technical advantages that are not found in competing technologies such as silicon-on-insulator (SOI) at high temperatures of 200°C to 300°C and beyond. The SiC integrated circuits and packaging methods can be used in new product introduction by GE Oil and Gas for high temperature down-hole tools. The existing SiC fabrication facility at GE is sufficient to support the quantities currently demanded by the marketplace, and there are other entities in the United States and other countries capable of ramping up SiC technology manufacturing. The ceramic circuit boards are different from traditional organic-based electronics circuit boards, but the fabrication process is compatible with existing ceramic substrate manufacturing. This project has brought high temperature electronics forward, and brings us closer to commercializing tools that will enable and reduce the cost of enhanced geothermal technology to benefit the public in terms of providing clean renewable energy at lower costs.

15 GEOTHERMAL ENERGY↗

Cryogenic High Pressure Sensor Module

A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

Chapman, John J.↗

Cryogenic, Absolute, High Pressure Sensor

A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

John J Chapman↗

Development of GaN-based microchemical sensor nodes

Sensors based III-N technology are gaining significant interest due to their potential for monolithic integration of RF transceivers and light sources and the capability of high temperature operations. We are developing a GaN-based micro chemical sensor node for remote detection of chemical toxins, and present electrical responses of AlGaN/GaN HEMT (High Electron Mobility Transistor) sensors to chemical toxins as well as other common gases.

extreme environment↗

Effects of break geometry and orientation on helium-air mixing in simulated reactor cavities of high temperature gas reactors

Here, this study experimentally examined the spatial and temporal variations in air and helium concentrations and temperature fields within simulated reactor cavities of a High Temperature Gas Reactor (HTGR) following helium discharge into an initially air-filled reactor cavity system. Detailed temperature maps were generated using a combination of fiber optics temperature sensor and multiple thermocouple probes within the simulated reactor cavities. The research scenario involved a hypothetical small pipe break in the Reactor Pressure Vessel, resulting in the release of high-temperature helium into the surrounding cavity. A scaled multi-compartment experimental facility, modeled after the General Atomics Modular High Temperature Gas Reactor (GA-MHTGR) design, was constructed for helium and air mixing experiments. Oxygen sensors and thermocouple probes were installed in all five cavities to measure the concentrations of oxygen (or helium) and the temperature distributions of the gas mixture. The experimental findings highlighted the significant impact of the injected helium jet velocity on the gas mixing process and demonstrated how the direction of the helium jet influences the air-helium temperature profiles within the cavities.

Air-ingress↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. For this reason, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). The goal of this research is to characterize magnetostrictive and piezoelectric transducer survivability during irradiation, enabling the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). As such, this test will be an instrumented lead test and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers.

In-Pile Instrumentation, Material and Test Reactor↗