Infrared range sensor

Sensor employs triangulation technique to locate objects that lie in intersections of four emitted beams of light and fields of view of four phototransistors. Signals from individual phototransistors are filtered and identified by individual synchronous detectors, one for each beam-intersection point.

Hill, J. W.↗

Surface temperature determination in surface analytic systems by infrared optical pyrometry

An IR pyrometric technique for measuring the surface temperatures of metal specimens in an ultrahigh-vacuum analytic chamber is described and demonstrated. The experimental setup comprises a commercial IR microscope with a long-working-distance right-angle objective (focal spot diameter 1 mm at 53 cm), a metal-coated glass vacuum chamber with a Ta-mesh-covered quartz viewport, an Mo specimen stub with an internal heating element, and a Ta disk test specimen with a flat side coated with a high-emissivity graphite film. The results of an initial calibration test are presented graphically and briefly characterized. The measurement error at 450 C is found to be less than 10 C.

Wheeler, Donald R.↗

Remote spectral identification of surface aggregates by thermal imaging techniques - Progress report

The NASA Thermal Infrared Multispectral Scanner (TIMS) has been successfully used for the remote identification of a variety of soil and aggregate deposits in vegetated areas of two states. Over three million cubic meters of gravel deposits were identified from the imagery during a two year period. Verification was accomplished by ground reconnaissance using drilling machinery and by ground instrumentation. The method has been used to differentiate between fine and coarse grained soils, and gravel deposits. The deposits were found to have been naturally sorted according to grain size by depositional processes, providing each deposit with distinct spectral qualities. It was found that the masking effects of relatively dense vegetation were largely overcome by using imagery acquired at higher altitudes above terrain than 9000 meters, due to loss of resolution of the finer detail. The mechanics of image resolution are discussed, a method of data analysis used is described, and sample spectral signatures are illustrated.

Scholen, Douglas E.↗

Methanol Partial Oxidation on MoO 3 /SiO 2 Catalysts: Application of Vibrational Spectroscopic Imaging Techniques in a High Throughput Operando Reactor

A novel prototype high throughput operando (OHT) reactor designed and built for catalyst screening and characterization is presented in this article. For the first time, this OHT reactor integrates Fourier Transformation infrared (FT-IR) imaging technique and Raman spectroscopy in operando conditions. Using a focal plane array (HgCdTe FPA, 128x128 pixels, and 1,675 Hz frame rate) detector for the FT-IR imaging system, we are able to simultaneously follow the catalyst activity and selectivity of all parallel reaction channels. Each set of image data has 16, 384 IR spectra with a spectral range of 900-4000 cm-1 in an 8 cm-1 resolution. It only takes 2-20 second, depending on signal to noise ratio, to collect a full image of all reaction channels. Results on reactant conversion and product selectivity are obtained from FT-IR spectral analysis. Six home-designed Raman probes, one for each reaction channel, are used for simultaneous collection of Raman spectra of all catalysts and possible reaction intermediates on the catalyst surface under real reaction environment. As a model system, methanol partial oxidation reaction on silica supported molybdenum oxide (MoO 3 /SiO 2 ) catalysts under different reaction conditions has been studied to show the performance of the OHT reactor.

10 SYNTHETIC FUELS↗

Resolution improvement of remote sensing data.

Discussion of the theory of a technique for image restoration in the reconstruction of a spatial input scene mapped by a line scanner. Special attention is given to the application of this technique in reducing the data telemetered from the Infrared Scanning Radiometer of the Apollo 17 spacecraft. The technique is based on the theory of splines and uses the results of optimal approximation studies by Colomb (1959), Sard (1967), and Anselone (1968). A recursive algorithm is also developed to improve the reconstruction. The study treats a one-dimensional case, but the treatment can be readily extended to multi-dimensional situations.

Caprihan, A.↗

Determination of stratospheric temperature and height gradients from Nimbus 3 radiation data

To improve the specification of stratospheric, horizontal, temperature and geopotential height fields needed for high-flying aircraft, we derived a technique to estimate data between satellite tracks using interpolated infrared interferometer spectrometer 15-micron radiation data from Nimbus 3. The interpolation is based on the observed gradients of the medium resolution infrared 15-micron radiances between subsatellite tracks. The technique was verified with radiosonde data taken within 6 hr of the satellite data. Comparison indicates that the technique developed here produces analyses that are in general agreement with those from radiosonde data. In addition, this technique provides details over areas of sparse data not shown by conventional techniques.

Nicholas, G. W.↗

Comparison of column water vapor measurements using downward-looking near-infrared and infrared imaging systems and upward-looking microwave radiometers

Remote soundings of precipitable water vapor from three systems are compared with each other and with ground truth from radiosondes. Ancillary data from a mesoscale network of surface observing stations and from wind-profiling radars are also used in the analysis. The three remote-sounding techniques are: (a) a reflectance technique using spectral data collected by the Airborne Visible-Infrared Imaging Spectrometer; (b) an emission technique using Visible-Infrared Spin Scan Radiometer Atmospheric Sounder (VAS) data acquired from the NOAA's GOES; and (c) a microwave technique using data from a limited network of three ground-based dual-channel microwave radiometers. The data were taken over the Front Range of eastern Colorado on 22-23 March 1990. The generally small differences between the three types of remote-sounding measurements are consistent with the horizontal and temporal resolutions of the instruments. The microwave and optical reflectance measurements agreed to within 0.1 cm; comparisons of the microwave data with radiosondes were also either as good or explainable. The largest differences between the VAS and the microwave radiometer at Elbert were between 0.4 and 0.5 cm and appear to be due to variable terrain within the satellite footprint.

Gao, Bo-Cai↗

Optical nonlinearities and ultrafast all-optical switching of m-plane GaN in the near-infrared

We reported a systematic investigation on the three-photon absorption (3PA) spectra and wavelength dispersion of Kerr refraction of bulk m-plane GaN crystal with both polarization E⊥c and E//c by femtosecond Z-scan technique in the near-infrared region from 760 to 1030 nm. Both 3PA spectra and Kerr refraction dispersion were in good agreement with two-band models. The calculated nonlinear figure of merit and measured ultrafast nonlinear refraction dynamics via femtosecond pump-probe with phase object method revealed that m-plane GaN would be a promising candidate for ultrafast all-optical switching and autocorrelation applications at telecommunication wavelengths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nighttime Cirrus Detection using Atmospheric Infrared Sounder Window Channels and Total Column Water Vapor

A method of cirrus detection at nighttime is presented that utilizes 3.8 and 10.4 (micro)m infrared (IR) window brightness temperature differences (dBT) and total column precipitable water (PW) measurements. This technique is applied to the Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Sounding Unit A (AMSU-A) instrument suite on board EOS-Aqua, where dBT is determined from sets of carefully selected AIRS window channels, while PW is derived from the synergistic AIRS and AMSU-A water vapor retrievals. Simulated and observed dBT for a particular value of PW are not constant; several physical factors impact dBT, including the variability in temperature and relative humidity profiles, surface emissivity, instrument noise, and skin/ near-surface air temperature differences. We simulate clear-sky dBT over a realistic range of PWs using 8350 radiosondes that have varying temperature and relative humidity profiles. Thresholds between cloudy and uncertain sky conditions are derived once the scatter in the clear-sky dBT is determined. Simulations of optically thin cirrus indicate that this technique is most sensitive to cirrus optical depth in the 10 (micro)m window of 0.1-0.15 or greater over the tropical and subtropical oceans, where surface emissivity and skin/near-surface air temperature impacts on the IR radiances are minimal. The method at present is generally valid over oceanic regions only, specifically, the tropics and subtropics. The detection of thin cirrus, and other cloud types, is validated using observations at the Atmospheric Radiation Measurement (ARM) program site located at Manus Island in the tropical western Pacific for 89 coincident EOS-Aqua overpasses. Even though the emphasis of this work is on the detection of thin cirrus at nighttime, this technique is sensitive to a broad cloud morphology. The cloud detection technique agrees with ARM-detected clouds 82-84% of the time, which include thin cirrus, as well as other cloud types. Most of the disagreements are well explained by AIRS footprint-scale heterogeneity compared to ARM point measurements, cirrus overlying lower-layer water clouds, possible mixed phase microphysics in midlevel clouds, and significant IR channel noise for cold BT scenes over deep convective towers.

Atmospheric Radiation Measurement (RAM)↗

Infrared Imaging Of Flows Seeded With SF6

Novel technique enables repeated measurements of flow patterns during flight. Wing-tip vorticity studied in flight by observing infrared emissions from SF6 gas entrained in wing-tip flow. System makes vortical flows visible throughout all altitude and speed ranges of all subsonic aircraft. Also useful for transonic and supersonic speeds. Primary application is testing of aircraft in flight, also proves useful in testing fast land vehicles and structures or devices subject to strong winds.

Manuel, Gregory S.↗

Introduction of Soft X-Ray Spectromicroscopy as an Advanced Technique for Plant Biopolymers Research

Soft X-ray absorption spectroscopy coupled with nano-scale microscopy has been widely used in material science, environmental science, and physical sciences. In this work, the advantages of soft X-ray absorption spectromicroscopy for plant biopolymer research were demonstrated by determining the chemical sensitivity of the technique to identify common plant biopolymers and to map the distributions of biopolymers in plant samples. The chemical sensitivity of soft X-ray spectroscopy to study biopolymers was determined by recording the spectra of common plant biopolymers using soft X-ray and Fourier Transform mid Infrared (FT-IR) spectroscopy techniques. The soft X-ray spectra of lignin, cellulose, and polygalacturonic acid have distinct spectral features. However, there were no distinct differences between cellulose and hemicellulose spectra. Mid infrared spectra of all biopolymers were unique and there were differences between the spectra of water soluble and insoluble xylans. The advantage of nano-scale spatial resolution exploited using soft X-ray spectromicroscopy for plant biopolymer research was demonstrated by mapping plant cell wall biopolymers in a lentil stem section and compared with the FT-IR spectromicroscopy data from the same sample. The soft X-ray spectromicroscopy enables mapping of biopolymers at the sub-cellular (~30 nm) resolution whereas, the limited spatial resolution in the micron scale range in the FT-IR spectromicroscopy made it difficult to identify the localized distribution of biopolymers. The advantages and limitations of soft X-ray and FT-IR spectromicroscopy techniques for biopolymer research are also discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of material degradation in ceramic matrix composites using infrared reflectance spectroscopy

Ceramic matrix composite materials for thermal protection systems are required to maintain operational performance in extreme thermal and mechanical environments. In-service inspection of materials capable of assessing the degree and extent of damage and degradation will be required to ensure the safety and readiness of future air vehicles. Infrared reflectance spectroscopy is an established material characterization technique capable of extracting information regarding the chemical composition of substances. The viability of this technique as a potentially powerful nondestructive evaluation method capable of monitoring degradation in thermal protection system materials subjected to extreme mechanical and thermal environments is analyzed. Several oxide-based and non-oxide-based ceramic matrix composite materials were stressed to failure in a high temperature environment and subsequently measured using infrared reflectance spectroscopy. Spectral signatures at locations along the length of the samples were compared resulting in distinct and monotonic reflectance peak changes while approaching the fracture point. The chemical significance of the observed signatures and the feasibility of infrared reflectance nondestructive evaluation techniques are discussed.

36 MATERIALS SCIENCE↗

High Resolution Spectroscopy to Support Atmospheric Measurements

Spectroscopic parameters (such as line position, intensity, broadening and shifting coefficients and their temperature dependences, line mixing coefficients etc.) for various molecular species of atmospheric interest are determined. In order to achieve these results, infrared spectra of several molecular bands are obtained using high-resolution recording instruments such as tunable diode laser spectrometer and Fourier transform spectrometers. Using sophisticated analysis routines (Multispectrum nonlinear least squares technique) these high-resolution infrared spectra are processed to determine the various spectral line parameters that are cited above. Spectra were taken using the McMath-Pierce Fourier transform spectrometer (FTS) at the National Solar Observatory on Kitt Peak, Arizona as well as the Bruker FTS at the Pacific Northwest National Laboratory (PNNL) at Richland, Washington. Most of the spectra are acquired not only at room temperature, but also at several different cold temperatures. This procedure is necessary to study the variation of the spectral line parameters as a function of temperature in order to simulate the Earth's and other planetary atmospheric environments. Depending upon the strength or weakness of the various bands recorded and analyzed, the length(s) of the absorption cells in which the gas samples under study are kept varied from a few centimeters up to several meters and the sample temperatures varied from approximately +30 C to -63 C. Research on several infrared bands of various molecular species and their isotopomers are undertaken. Those studies are briefly described.

Venkataraman, Malathy Devi↗

Infrared line parameters at low temperatures relevant to planetary atmospheres

Employing the techniques that were described in several publications for measuring infrared lineshifts, linewidths and line intensities with a tunable diode laser, these parameters were measures for lines in the important infrared bands of several molecules of interest to the planetary astronomer at low temperatures that are relevant to planetary atmospheres using He, Ne, Ar, H2, N2, O2, and air as the perturbers. In addition to obtaining the many original data on the temperature dependence of the intensities and linewidths, it was also the first measurement of the same for the collision-induced lineshift of an infrared line and it showed that it was markedly different from that of the corresponding collision-broadened linewidth.

Varanasi, Prasad↗

Decomposition of NO studied by infrared emission and CO laser absorption

A diagnostic technique for monitoring the concentration of NO using absorption of CO laser radiation was developed and applied in a study of the decomposition kinetics of NO. Simultaneous measurements of infrared emission by NO at 5.3 microns were also made to validate the laser absorption technique. The data were obtained behind incident shocks in NO-N2O-Ar (or Kr) mixtures, with temperatures in the range 2400-4100 K. Rate constants for dominant reactions were inferred from comparisons with computer simulations of the reactive flow.

Hanson, R. K.↗

Infrared absorption spectroscopy of dynamically compressed water

Presentation describes development of a time-stretch spectroscopy diagnostic using dispersed supercontinuum laser pulses. The technique is applied to near-infrared measurements of liquid water during multiple shock compression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decomposition of NO studied by infrared emission and CO laser absorption

A diagnostic technique for monitoring the concentration of NO using absorption of CO laser radiation has been developed and applied in a study of the decomposition kinetics of NO. Simultaneous measurements of infrared emission by NO at 5.3 microns were also made to validate the laser absorption technique. The data were obtained behind incident shocks in NO-N2O-Ar (or Kr) mixtures, with temperatures in the range 2400-4100 K. The rate constant for the dominant reaction of O and NO to yield N and O2 was inferred from comparisons with computer simulations of the reactive flow.

Hanson, R. K.↗

Science with High Spatial Resolution Far-Infrared Data

The goal of this workshop was to discuss new science and techniques relevant to high spatial resolution processing of far-infrared data, with particular focus on high resolution processing of IRAS data. Users of the maximum correlation method, maximum entropy, and other resolution enhancement algorithms applicable to far-infrared data gathered at the Infrared Processing and Analysis Center (IPAC) for two days in June 1993 to compare techniques and discuss new results. During a special session on the third day, interested astronomers were introduced to IRAS HIRES processing, which is IPAC's implementation of the maximum correlation method to the IRAS data. Topics discussed during the workshop included: (1) image reconstruction; (2) random noise; (3) imagery; (4) interacting galaxies; (5) spiral galaxies; (6) galactic dust and elliptical galaxies; (7) star formation in Seyfert galaxies; (8) wavelet analysis; and (9) supernova remnants.

Terebey, Susan↗