Search NASASearch

SEARCH · Search NASA

Results for “Lunar Surface Thermal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,614 records · Page 35

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY

Stellar Population Properties in the Stellar Streams around SPRC047

Abstract We have investigated the properties (e.g., age, metallicity) of the stellar populations of a ringlike tidal stellar stream (or streams) around the edge-on galaxy SPRC047 (z= 0.031) using spectral energy distribution (SED) fits to integrated broadband aperture flux densities. We used visual images in six different bands and Spitzer/IRAC 3.6μm data. We have attempted to derive best-fit stellar population parameters (metallicity, age) in three noncontiguous segments of the stream. Due to the very low surface brightness of the stream, we have performed a deconvolution with a Richardson–Lucy–type algorithm of the low spatial resolution 3.6μm IRAC image, thereby reducing the effect of the point-spread function aliasedemissionfrom the bright edge-on central galaxy at the locations of our three stream segments. Our SED fits that used several different star formation (SF) history priors, from an exponentially decaying SF burst to continuous SF, indicate that the age–metallicity–dust degeneracy is not resolved, most likely because of inadequate wavelength coverage and low signal-to-noise ratios of the low surface brightness features. We also discuss how future deep visual–near-infrared observations, combined with absolute flux calibration uncertainties at or below the 1% level, complemented by equally well absolute flux-calibrated observations in ultraviolet and mid-infrared bands, would improve the accuracy of broadband SED fitting results for low surface brightness targets, such as stellar streams around nearby galaxies that are not resolved into stars.

Astronomy & Astrophysics

Thermal Protection Facility: Taking the Heat

Video highlighting the products and manufacturing capabilities of the Thermal Protection Facility at Kennedy Space Center which is part of the JSC EA/ES division. This record includes an mp4 video with a run time of 9 min. 13 sec.; in color; with sound.

TPSF

Metallurgical and Thermal Properties of 57Ni-40Ti-3Hf (wt%)

Selected properties of 57Ni-40Ti-3Hf (wt%) were measured to further develop this material for use in aerospace rolling-element bearings. The average grain size and microindentation hardness of the material at room temperature were 90 μm and 549 HV, respectively. From room temperature to 500 °C, electrical resistivity increased from 8.9×10–7 to 11.3×10–7 Ω⋅m, thermal expansion coefficients varied from 1.1×10–5 to 1.2×10–5 mm/mm⋅°C, specific heat increased from 0.44 to 0.53 W⋅sec/g⋅K, thermal diffusivity rose from approximately 0.003 to 0.005 cm2/sec and thermal conductivity increased from approximately 0.09 to 0.19 W/cm⋅K. The behavior of the material can be explained by well-known metallurgical theory. These results are expected to provide a basis for design and modeling of future aerospace components.

rule of mixtures

SR-1 Freedom Thermal Architecture Challenges

The SR-1 Freedom mission aims to demonstrate nuclear electric propulsion (NEP) and deliver the Skyfall helicopter payload to Mars. Repurposing the existing Gateway Power and Propulsion Element (PPE) spacecraft and combining it with a 20 kWe-class nuclear power module (NPM) presents a variety of thermal architecture challenges. These include unprecedented waste heat rejection requirements, integration with a spacecraft bus originally designed for a different mission profile, and novel packaging constraints. This presentation will describe the simplified concept of operations as it relates to on-orbit thermal environments, early-phase architecture trades and supporting analyses, and planned forward work. We will also discuss our strategy for integrated thermal modeling of the complete spacecraft and examples of interface challenges necessitated by this ambitious effort.

Thermal

Practical Battery Thermal Modeling Techniques

Lithium-ion batteries are thermo-electrochemical devices, whereby nearly every facet of their functionality and performance are thermally driven. As a result, it is important to have thermal modeling techniques that effectively capture the intricacies of both the electrochemical nature of the battery and also the complex thermal network that typically results from the design of the battery thermal management system. Here we present a thermal modeling workflow and a set of general assumptions for how to construct a thermal model of a Li-ion battery pack. We use a 14-cell bank of 18650-format Li-ion cells, loosely based on a proposed alternative battery design for Orion, as the example. Although the workflow is performed with Thermal Desktop and related utilities, the focus of this presentation is less about software specific techniques, but rather is focused on the assumptions and conditions that should be used in a model (regardless of the tool used to build the model). Example cases and results will be presented for charge, discharge, and thermal runaway.

lithium-ion battery