Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Spectroscopic research of Lambda hypernuclei up to medium-heavy mass region with the (e,e'K + ) reaction

In 2009 (August-November), the E05-115 experiment was carried out at JLab to investigate L hypernuclei in the wide mass region up to A = 52 ($7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V) with the (e,e'K + ) reaction. This is the first attempt to investigate a medium heavy L hypernucleus with the (e,e'K + ) reaction. Experimentally, it is difficult to measure heavier L hypernuclei as background rates of particles which originate from electromagnetic processes are roughly in proportion to Z2 (Z: target proton number) in the (e,e'K + ) experiment. To perform the experiment, many experimental techniques have been developed and introduced such as optimization of the electron spectrometer configuration (tilt method), clean kaon identification, particle tracking under high multiplicity environment, precise energy scale calibration and so on. In the present thesis, experimental results of the elementary process of p(e,e'K + )L, L hypernuclei of $7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V are shown. Elementary processes of the electroproduction of L and Σ 0 , p(e,e'K + )L, Σ 0 were used for the absolute energy scale calibration of our spectrometer systems. A careful Monte Carlo simulation shows that the binding energy can be obtained with a systematic error of 0.11 MeV with our energy scale calibration method. A study of the elementary process of L is important to understand L hypernuclei as it is essential for theoretical calculations of L hypernuclei. The differential cross section of the p(e,e'K + )L reaction at the small K + scattering angle (theta-CM/gamma-K approx. 15.5°), the small Q 2 (approx 0.01 [GeV/c] 2 ) and the total energy of W = 1.92 GeV, where no experimental data exists was obtained to be 235 ± 13$+28\atop{-24}$ nb/sr. The ground state (1/2 + ) binding energy of $7\atop{Λ}$He was already measured in JLab E01-011 (2005). In the present work, the binding energy of 1/2 + state was determined to be B Λ = 5.55 ± 0.10 ±0.11 MeV with five times more statistic and smaller systematic errors than those of the previous experiment. The ground state binding energy is important to test the phe- nomenologically introduced CSB (Charge Symmetry Breaking) LN interaction for A = 7, T = 1 hypernuclear systems. In addition, a peak which is interpreted as 3/2 + and 5/2 + states was measured to be B Λ = 3.65 ± 0.20 ±0.11 MeV with sufficient statistic for the first time. Only three events of the ground state of $10\atop{Λ}$ Be had been observed in the emulsion experiments. The present experiment is the first spectroscopic measurement of 10/L-Be, and the detailed structures have been successfully measured for the first time. About three times better energy resolution was achieved in the present experiment (0.78 MeV in FWHM) than that of the mirror L hy- pernucleus, $10\atop{Λ}$B (2.2 MeV in FWHM) which was measured in the (π + ,K + ) experiment at KEK. The result of the ground state binding energy was obtained to be B Λ = 8.55 ± 0.07 ± 0.11 MeV which serves also to discuss about the CSB effect in the LN interaction. $12\atop{Λ}$B has been measured with the world best energy resolution of 0:5 MeV (FWHM) among the reaction spectroscopy of L hypernuclei. The results of $12\atop{Λ}$B are compared with the experimental results in the previous experiments to confirm the consistency. Furthermore, the obtained ground state binding energies of $12\atop{Λ}$B (B Λ = 11.38 ± 0.02 ± 0.11 MeV) and $52\atop{Λ}$V (B Λ = 21.88 ± 0.59 ± 0.11 MeV) indicate that the reported value of 12/L-C which has been used as a reference of binding energy measurements for the (π + ,K + ) experiments would be shallower by ~ 0.5 MeV. A pilot study for investigation in the medium-heavy mass region with the (e,e'K + ) experiment was performed by measuring $52\atop{Λ}$V. The ground state binding energy of $52\atop{Λ}$V has been measured, overcoming high multiplicity environment. The results are discussed with the ex- perimental results of 51/L-V measured at KEK. The present result is the first measurement of L's binding energy of the ground state without the emulsion reference in the medium-heavy mass region, which could be a substantial improvement in the information needed for understanding the single particle potential of L. In the present experiment, L hypernuclear measurement with a small systematic error of ~ 0.1 MeV by the (e,e'K + ) reaction has been established. Moreover, the present work opened a door to the heavier L hypernuclear measurement with the (e,e'K + ) reaction in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Distance-preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck

Purpose: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. Methods: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1–C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. Results: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. Conclusions: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

A STATISTICAL STUDY OF THE SOLAR WIND TURBULENCE AT ION KINETIC SCALES USING THE K-FILTERING TECHNIQUE AND CLUSTER DATA

Plasma turbulence at ion kinetic scales in the solar wind is investigated using the multi-point magnetometer data from the Cluster spacecraft. By applying the k-filtering method, we are able to estimate the full three-dimensional power spectral density P(ω{sub sc}, k) at a certain spacecraft frequency ω{sub sc} in wavevector (k) space. By using the wavevector at the maximum power in P(ω{sub sc}, k) at each sampling frequency ω{sub sc} and the Doppler shifted frequency ω{sub pla} in the solar wind frame, the dispersion plot ω{sub pla} = ω{sub pla}(k) is found. Previous studies have been limited to very few intervals and have been hampered by large errors, which motivates a statistical study of 52 intervals of solar wind. We find that the turbulence is predominantly highly oblique to the magnetic field k >> k {sub ∥}, and propagates slowly in the plasma frame with most points having frequencies smaller than the proton gyrofrequency ω{sub pla} < Ω{sub p}. Weak agreement is found that turbulence at the ion kinetic scales consists of kinetic Alfvén waves and coherent structures advected with plasma bulk velocity plus some minor more compressible components. The results suggest that anti-sunward and sunward propagating magnetic fluctuations are of similar nature in both the fast and slow solar wind at ion kinetic scales. The fast wind has significantly more anti-sunward flux than sunward flux and the slow wind appears to be more balanced.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi Optical Transition Radiation System for ATF2

In this paper we describe the design, installation and first calibration tests of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. This system will be a valuable tool for measuring beam sizes and emittances coming from the ATF Damping Ring. With an optical resolution of about 2 {micro}m an original OTR design (OTR1X) located after the septum at the entrance of the EXT line demonstrated the ability to measure a 5.5 {micro}m beam size in one beam pulse and to take many fast measurements. This gives the OTR the ability to measure the beam emittance with high statistics, giving a low error and a good understanding of emittance jitter. Furthermore the nearby wire scanners will be a definitive test of the OTR as a beam emittance diagnostic device. The multi-OTR system design proposed here is based on the existing OTR1X.

43 PARTICLE ACCELERATORS↗

Impact of non-Maxwellian electron velocity distribution functions on inferred plasma parameters in collective Thomson scattering

Optical collective Thomson scattering provides precise density and temperature measurements in numerous plasma-physics experiments. The accuracy of such measurements depends on the core assumption that the underlying electron distribution functions in under-dense laser-produced plasmas are Maxwellian. A statistically based, quantitative analysis of the errors in the measured electron density and temperature is presented when synthetic data calculated using a non-Maxwellian electron distribution function is fit assuming a Maxwellian electron distribution. Such analysis can lead to errors of up to 50% in temperature and 30% in density, in the specific case of super-Gaussian distributions characteristic of inverse bremsstrahlung heating. Furthermore including the proper family of non-Maxwellian electron distribution functions, as a fitting parameter, in Thomson-scattering analysis removes the model-dependent errors in the inferred parameters at a minimal cost to the statistical uncertainty.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Multi Optical Transition Radiation System

The determination and monitoring of the transverse phase space in ATF2 is crucial in order to meet their performances specifications. Since the beam sizes at the Interaction Point (IP) depend strongly on the aberrations in the Final Focus System (FFS), accurate measurement upstream of the FFS is required to tune the beam sizes at the IP. The beam sizes as well as the emittance are measured in several locations in the beam diagnostic section of the Extraction Line (EXT line) of ATF2. The vertical beam sizes in the diagnostic section are of the order of 10 {mu}m this means that the devices have to image spot sizes as small as 5 {mu}m, with 10% accuracy a 2 {mu}m resolution device is necessary. The ATF2 EXT line is a beam line with low power and low repetition rate that make usable devices using solid targets. In contrast to a ring machine, where an individual bunch can be measured many times as it passes around the ring, the beam size and the emittance measurement in the LC or in the beam lines have to be performed in a single pass. This requires that the wire scan device types (laser or solid) sample across successive bunches within a train, often with an over-estimation of the beam size due to beam position and intensity jitter, and can take up to half a minute to complete the measurement. Although some of these effects could be corrected, as the jitter effect could be subtracted by using the nearby BPMs signals, this can be avoided by using Optical Transition Radiation (OTR) Monitors. These monitors are based on the transition radiation effect, a light cone emitted when the charged particle crosses a metallic interface. This light is emitted in a specular fashion so it can be focused on to a CCD and produces an image of the beam. OTRs are able to take many fast measurements and therefore to measure the emittance with high statistics, giving a low error and a good understanding of the emittance jitter. In this article, simulations of the expected beam sizes and emittance, along with a technical description of the system, its hardware and software implementation are described. Additionally first measurement of the beam size and emittance of the Multi Optical Transition Radiation System located in the Extraction Line of ATF2 are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlated theoretical uncertainties for the one-jet inclusive cross section

We discuss the correlated systematic theoretical uncertainties that may be ascribed to the next-to-leading order QCD theory used to predict the one-jet inclusive cross section in hadron collisions. We estimate the magnitude of these errors as functions of the jet transverse momentum and rapidity. The total theoretical error is decomposed into a set of functions of transverse momentum and rapidity that give a model for statistically independent contributions to the error. This representation can be used to include the systematic theoretical errors in fits to the experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prostate Intrafraction Motion Assessed by Simultaneous kV Fluoroscopy at MV Delivery II: Adaptive Strategies

Purpose: To investigate potential benefits of adaptive strategies for managing prostate intrafractional uncertainties when interfraction motion is corrected online. Methods and Materials: Prostate intrafraction motion was measured using kV fluoroscopy during MV delivery for 571 fractions from 30 hypofractionated radiotherapy patients. We evaluated trending over treatment course using analysis of variance statistics, and we evaluated the ability to correct patient-specific systematic error and apply patient-specific statistical margins after 2 to 15 fractions to compensate 90% of motion. We also evaluated the ability to classify patients into small- and large-motion subgroups based on the first 2 to 20 fractions using discriminant analysis. Results: No time trend was observed over treatment course, and intrafraction motion was patient specific (p < 0.0001). Systematic error in the first week correlated well with that in subsequent weeks, with correlation coefficients of 0.53, 0.50, and 0.41 in right-left (RL), anterior-posterior (AP), and superior-inferior (SI), respectively. After 5 fractions, the adaptive strategy resulted in average margin reductions of 0.3, 0.7, and 0.7 mm in RL, AP, and SI, respectively, with margins ranging from 1 to 3.2 mm in RL, 2 to 7.0 mm in AP, and 2 to 6.6 mm in SI. By contrast, population margins to include the same percentage of motion were 1.7, 4.0, and 4.1 mm. After 2 and 5 fractions, patients were classified into small- and large-motion groups with {approx}77% and {approx}83% accuracy. Conclusions: Adaptive strategies are feasible and beneficial for intrafraction motion management in prostate cancer online image guidance. Patients may be classified into large- and small-motion groups in early fractions using discriminant analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Workflow for Accelerating Multimodal Data Collection for Electrodeposited Films

Abstract Future machine learning strategies for materials process optimization will likely replace human capital-intensive artisan research with autonomous and/or accelerated approaches. Such automation enables accelerated multimodal characterization that simultaneously minimizes human errors, lowers costs, enhances statistical sampling, and allows scientists to allocate their time to critical thinking instead of repetitive manual tasks. Previous acceleration efforts to synthesize and evaluate materials have often employed elaborate robotic self-driving laboratories or used specialized strategies that are difficult to generalize. Herein we describe an implemented workflow for accelerating the multimodal characterization of a combinatorial set of 915 electroplated Ni and Ni–Fe thin films resulting in a data cube with over 160,000 individual data files. Our acceleration strategies do not require manufacturing-scale resources and are thus amenable to typical materials research facilities in academic, government, or commercial laboratories. The workflow demonstrated the acceleration of six characterization modalities: optical microscopy, laser profilometry, X-ray diffraction, X-ray fluorescence, nanoindentation, and tribological (friction and wear) testing, each with speedup factors ranging from 13–46x. In addition, automated data upload to a repository using FAIR data principles was accelerated by 64x.

36 MATERIALS SCIENCE↗

Snowmass2021 - Letter of interest cosmology intertwined IV: The age of the universe and its curvature

A precise measurement of the curvature of the Universe is of prime importance for cosmology since it could not only confirm the paradigm of primordial inflation but also help in discriminating between different early-Universe scenarios. Recent observations, while broadly consistent with a spatially flat standard Λ Cold Dark Matter ( Λ CDM) model, show tensions that still allow (and, in some cases, even suggest) a few percent deviations from a flat universe. In particular, the Planck Cosmic Microwave Background power spectra, assuming the nominal likelihood, prefer a closed universe at more than 99% confidence level. While new physics could be at play, this anomaly may be the result of an unresolved systematic error or just a statistical fluctuation. However, since positive curvature allows a larger age of the Universe, an accurate determination of the age of the oldest objects provides a smoking gun in confirming or falsifying the current flat Λ CDM model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation and comparison of benchmark QSAR models to predict a relevant REACH endpoint: The bioconcentration factor (BCF)

The bioconcentration factor (BCF) is an important bioaccumulation hazard assessment metric in many regulatory contexts. Its assessment is required by the REACH regulation (Registration, Evaluation, Authorization and Restriction of Chemicals) and by CLP (Classification, Labeling and Packaging). We challenged nine well-known and widely used BCF QSAR models against 851 compounds stored in an ad-hoc created database. The goodness of the regression analysis was assessed by considering the determination coefficient (R{sup 2}) and the Root Mean Square Error (RMSE); Cooper's statistics and Matthew's Correlation Coefficient (MCC) were calculated for all the thresholds relevant for regulatory purposes (i.e. 100 L/kg for Chemical Safety Assessment; 500 L/kg for Classification and Labeling; 2000 and 5000 L/kg for Persistent, Bioaccumulative and Toxic (PBT) and very Persistent, very Bioaccumulative (vPvB) assessment) to assess the classification, with particular attention to the models' ability to control the occurrence of false negatives. As a first step, statistical analysis was performed for the predictions of the entire dataset; R{sup 2}>0.70 was obtained using CORAL, T.E.S.T. and EPISuite Arnot–Gobas models. As classifiers, ACD and log P-based equations were the best in terms of sensitivity, ranging from 0.75 to 0.94. External compound predictions were carried out for the models that had their own training sets. CORAL model returned the best performance (R{sup 2}{sub ext}=0.59), followed by the EPISuite Meylan model (R{sup 2}{sub ext}=0.58). The latter gave also the highest sensitivity on external compounds with values from 0.55 to 0.85, depending on the thresholds. Statistics were also compiled for compounds falling into the models Applicability Domain (AD), giving better performances. In this respect, VEGA CAESAR was the best model in terms of regression (R{sup 2}=0.94) and classification (average sensitivity>0.80). This model also showed the best regression (R{sup 2}=0.85) and sensitivity (average>0.70) for new compounds in the AD but not present in the training set. However, no single optimal model exists and, thus, it would be wise a case-by-case assessment. Yet, integrating the wealth of information from multiple models remains the winner approach. - Highlights: • REACH encourages the use of in silico methods in the assessment of chemicals safety. • The performances of nine BCF models were evaluated on a benchmark database of 851 chemicals. • We compared the models on the basis of both regression and classification performance. • Statistics on chemicals out of the training set and/or within the applicability domain were compiled. • The results show that QSAR models are useful as weight-of-evidence in support to other methods.

54 ENVIRONMENTAL SCIENCES↗

Inconsistent pathways of household waste

The aim of this study was to provide policy-makers and waste management planners with information about how recycling programs affect the quantities of specific materials recycled and disposed of. Two questions were addressed: which factors influence household waste generation and pathways? and how reliable are official waste data? Household waste flows were studied in 35 Swedish municipalities, and a wide variation in the amount of waste per capita was observed. When evaluating the effect of different waste collection policies, it was found to be important to identify site-specific factors influencing waste generation. Eleven municipal variables were investigated in an attempt to explain the variation. The amount of household waste per resident was higher in populous municipalities and when net commuting was positive. Property-close collection of dry recyclables led to increased delivery of sorted metal, plastic and paper packaging. No difference was seen in the amount of separated recyclables per capita when weight-based billing for the collection of residual waste was applied, but the amount of residual waste was lower. Sixteen sources of error in official waste statistics were identified and the results of the study emphasize the importance of reliable waste generation and composition data to underpin waste management policies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BEYONDPLANCK II. CMB mapmaking through Gibbs sampling

We present a Gibbs sampling solution to the mapmaking problem for cosmic microwave background (CMB) measurements that builds on existing destriping methodology. Gibbs sampling breaks the computationally heavy destriping problem into two separate steps: noise filtering and map binning. Considered as two separate steps, both are computationally much cheaper than solving the combined problem. This provides a huge performance benefit as compared to traditional methods and it allows us, for the first time, to bring the destriping baseline length to a single sample. Here, we applied the Gibbs procedure to simulated Planck 30 GHz data. We find that gaps in the time-ordered data are handled efficiently by filling them in with simulated noise as part of the Gibbs process. The Gibbs procedure yields a chain of map samples, from which we are able to compute the posterior mean as a best-estimate map. The variation in the chain provides information on the correlated residual noise, without the need to construct a full noise covariance matrix. However, if only a single maximum-likelihood frequency map estimate is required, we find that traditional conjugate gradient solvers converge much faster than a Gibbs sampler in terms of the total number of iterations. The conceptual advantages of the Gibbs sampling approach lies in statistically well-defined error propagation and systematic error correction. This methodology thus forms the conceptual basis for the mapmaking algorithm employed in the BEYONDPLANCK framework, which implements the first end-to-end Bayesian analysis pipeline for CMB observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal Countrates for Deadtime Corrections

The high x-ray flux available at synchrotron radiation sources can cause nonlinearities in photon-counting detectors unless deadtime corrections are employed. We compute the uncertainties associated with several common deadtime-correction formulas. At lower countrates, statistical noise dominates the error in the measured countrates; at higher countrates, the dominating factors are saturation of the response and uncertainty in the value of the deadtime parameter. In between, a range of countrates exists in which the signal-to-noise ratio can be optimized for photon-counting experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasi-classical description of molecular dynamics based on Egorov's theorem

Egorov's theorem on the classical propagation of quantum observables is related to prominent quasi-classical descriptions of quantum molecular dynamics as the linearized semiclassical initial value representation, the Wigner phase space method, or the statistical quasiclassical method. The error estimates show that different accuracies are achievable for the computation of expectation values and position densities. Numerical experiments for a Morse model of diatomic iodine and confined Henon–Heiles systems in various dimensions illustrate the theoretical results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Poisson-regularized inversion of Bremsstrahlung emission to extract full electron energy distribution functions from x-ray pulse-height detector data

We measured Electron Energy Distribution Functions (EEDFs) from below 200 eV to over 8 keV and spanning five orders-of-magnitude in intensity, produced in a low-power, RF-heated, tandem mirror discharge in the PFRC-II apparatus. The EEDF was obtained from the x-ray energy distribution function (XEDF) using a novel Poisson-regularized spectrum inversion algorithm applied to pulse-height spectra that included both Bremsstrahlung and line emissions. The XEDF was measured using a specially calibrated Amptek Silicon Drift Detector (SDD) pulse-height system with 125 eV FWHM at 5.9 keV. Finally, the algorithm is found to out-perform current leading x-ray inversion algorithms when the error due to counting statistics is high.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗