At least 649 records · Page 36

A Characterization of the Terrestrial Environment of Kodiak Island, Alaska for the Design, Development and Operation of Launch Vehicles

A quantitative characterization of the terrestrial environment is an important component in the success of a launch vehicle program. Environmental factors such as winds, atmospheric thermodynamics, precipitation, fog, and cloud characteristics are among many parameters that must be accurately defined for flight success. The National Aeronautics and Space Administration (NASA) is currently coordinating weather support and performing analysis for the launch of a NASA payload from a new facility located at Kodiak Island, Alaska in late 2001 (NASA, 1999). Following the first launch from the Kodiak Launch Complex, an Air Force intercontinental ballistic missile on November 5, 1999, the site's developer, the Alaska Aerospace Development Corporation (AADC), is hoping to acquire a sizable share of the many launches that will occur over the next decade. One such customer is NASA, which is planning to launch the Vegetation Canopy Lidar satellite aboard an Athena I rocket, the first planned mission to low earth orbit from the new facility. To support this launch, a statistical model of the atmospheric and surface environment for Kodiak Island, AK has been produced from rawinsonde and surface-based meteorological observations for use as an input to future launch vehicle design and/or operations. In this study, the creation of a "reference atmosphere" from rawinsonde observations is described along with comparisons between the reference atmosphere and existing model representations for Kodiak. Meteorological conditions that might result in a delay on launch day (cloud cover, visibility, precipitation, etc.) are also explored and described through probabilities of launch by month and hour of day. This atmospheric "mission analysis" is also useful during the early stages of a vehicle program, when consideration of the climatic characteristics of a location can be factored into vehicle designs. To be most beneficial, terrestrial environment definitions should a) be available at the inception of the program and based on the desired operational performance of the launch vehicle, b) be issued under the signature of the program manager and be part of the controlled program definition and requirements documentation, and c) specify the terrestrial environment for all phases of activity including prelaunch, launch, ascent, on-orbit, decent, and landing. Since the beginning of the space era, NASA has utilized some of the most detailed assessments of the terrestrial climatic environment in design, development, and operations of both expendable and reusable launch vehicles.

Rawlins, Michael A.↗

Evaluating Long-Term Changes in Atmospheric Ozone

Ozonesondes have made inexpensive, accurate measurements of ozone from the ground to 30km for more than 50 years. The data are used extensively for trend analyses and for evaluation of satellite and model data products, and are also part of climatologies that are used as a priori data for satellite retrievals. They are essential as a transfer standard when merging shorter satellite-derived time series, and are the most important source of trend-quality long-term records below about 18 km. The importance of long-term ozonesonde records as a stable reference has led to increased attention to quantifying uncertainties and changes in ozonesonde data. Based on past intercomparison data, ECC sondes show a modest (~1-5%) high bias with respect to UV-absorption measurements (including MOZAIC-IAGOS) in the troposphere, with an uncertainty of 5%, but no evidence of a change with time. Other sonde types show an increase of 5-20% in sensitivity to tropospheric ozone from 1970-1995. Agreement in the stratosphere is much better. In the past 20 years ozonesonde precision has improved by a factor of 2, primarily through the adoption of strict standard operating procedures. In addition, many of the most important ozonesonde records have been re-evaluated and corrected, and detailed estimates made of their biases and uncertainties. Corrections to historical data for known issues may reduce biases but simultaneously introduce additional uncertainties. The uncertainty budget for the ozone partial pressure reading has contributions from stoichiometry, cell background current, pump efficiency and temperature, sensing solution type and volume. The much-discussed “background current” has recently been shown to be primarily related to reaction stoichiometry. Several quality assurance issues remain, but are tractable problems that can be addressed with further research. This will be required if the present goal of better than 5% overall uncertainty throughout the global ozonesonde network is to be achieved. Finally, the importance of regular sonde intercomparisons, employing UV photometers traceable to the modern UV-absorption standard, and of regular comparison of operational station records with multiple satellite sensors, is emphasized.

Ozonesondes↗

Evaluating Heat Extraction Performance of Closed-Loop Geothermal Systems with Thermally Conductive Enhancements in Conduction-Only Reservoirs: Preprint

We investigated the impact of disc-shaped and linear thermal enhancements on performance of closed-loop geothermal systems using steady-state and transient COMSOL numerical simulations. Thermal enhancements refer to thermally conductive material introduced in the rocks surrounding a wellbore to compensate for the relatively low rock thermal conductivity and increase heat extraction. Materials proposed include composite cements with thermally conductive additives such as metals or graphite to obtain overall cement thermal conductivities of 10 to 100x the rock thermal conductivity. Our simulation approach was modeling a subsegment (e.g., 100 m long) of a wellbore with idealized (e.g., perfect disc-shaped) thermal enhancements, and we report results as relative increase in heat extraction with respect to systems without thermal enhancements. We did not evaluate technical feasibility or cost of installing thermal enhancements. Simulations indicate that for 5-mm thick disc-shaped thermal enhancements with 5-m radius, repeated every 1 m along the wellbore and with thermal conductivity of 100x the rock thermal conductivity, the thermal output increases roughly 20% with respect to a closed-loop system without thermal enhancements. For fishbone structure thermal enhancements, we estimate a roughly 7% increase in thermal output for 5-m long radially outward pipes with half the radius of the main wellbore, repeated every 2.5 m, with thermal conductivity of 100x the rock thermal conductivity.

advanced geothermal systems↗

Effect Of Ventilation On Chronic Health Risks In Schools And Offices

This study provides a risk assessment for chronic health risks from inhalation exposure to indoor air pollutants in offices and schools with a focus how ventilation impacts exposures to, and risks from, volatile organic compounds (VOCs) and particulate matter (PM2.5). We estimate how much health risks could change with varying ventilation rates under two scenarios: (i) halving the measured ventilation rates and (ii) doubling the measured ventilation rates. For the hazard characterization we draw upon prior papers that identified pollutants potentially affecting health with indoor air concentrations responsive to changes in ventilation rates. For exposure assessment we determine representative concentrations of pollutants using data available in current literature and model changes in exposures with changes in ventilation rates. As a metric of disease burden, we use disability adjusted life years (DALYs) to address both cancer and non-cancer effects. We also compare exposures to guidelines published by regulatory agencies to assess chronic health risks. Chronic health risks are driven primarily by particulate matter exposure, with an estimated baseline disease burden of 150 DALYs per 100,000 people in offices and 140 DALYs per 100,000 people in schools. Study results show that PM2.5-related DALYs are not very sensitive to changes in ventilation rates. Filtration is more effective at controlling PM2.5 concentrations and health effects. Non-cancer health effects contribute only a small fraction of the overall chronic health burden of populations in offices and schools (<1 DALY per 100,000 people). Cancer health effects dominate the disease burden in schools (3 DALYs per 100,000) and offices (5 DALYs per 100,000), with formaldehyde being the primary risk driver. In spite of large uncertainties in toxicological data and dose-response modeling, our results support the finding that ventilation rate changes do not have significant impacts on estimated chronic disease burdens. Median estimates of DALYs are approximately doubled when the ventilation rates are halved and there is little reduction in health risks associated with doubling ventilation rates, but the very low baseline disease burden from the indoor exposures we considered makes this unremarkable. In exploring the full range of exposure concentrations, to find the fraction exceeding the Office of Environmental Health and Hazard Assessment’s (OEHHAs) chronic reference exposure levels (cRELs) and United States Environmental Protection Agency’s (USEPA) chronic reference dose (RfD) we found only minor shifts in exposure safety margins when ventilation was doubled or halved. We combined our exposure estimates with cancer potency factors published by OEHHA and USEPA to determine that the annual excess cancer risk per capita are below 1 in a million under all ventilation rate scenarios for individual pollutants. The results indicate that chronic health risks (cancer and non-cancer) associated with VOC and PM2.5 exposure in offices and schools are low and thus the chronic disease burden or health benefits of ventilation changes are likely to be well below both the level of detection by health surveillance studies and the level of regulatory thresholds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Response of a Pressurized Water Reactor Dashpot Region to Commercial Drying Cycles

The purpose of this report is to document updates to the simulation of commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents testing updates for the Dashpot Drying Apparatus (DDA), an apparatus constructed at a reduced scale with multiple Pressurized Water Reactor (PWR) fuel rod surrogates and a single guide tube dashpot. This apparatus is fashioned from a truncated 5×5 section of a prototypic 17×17 PWR fuel skeleton and includes the lowest segment of a single guide tube, often referred to as the dashpot region. The guide tube in this assembly is open and allows for insertion of a poison rod (neutron absorber) surrogate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lobed Mixer Design for Noise Suppression Acoustic and Aerodynamic Test Data Analysis

A comprehensive database for the acoustic and aerodynamic characteristics of several model-scale lobe mixers of bypass ratio 5 to 6 has been created for mixed jet speeds up to 1080 ft/s at typical take-off (TO) conditions of small-to-medium turbofan engines. The flight effect was simulated for Mach numbers up to 0.3. The static thrust performance and plume data were also obtained at typical TO and cruise conditions. The tests were done at NASA Lewis anechoic dome and ASK's FluiDyne Laboratories. The effect of several lobe mixer and nozzle parameters, such as, lobe scalloping, lobe count, lobe penetration and nozzle length was examined in terms of flyover noise at constant altitude. Sound in the nozzle reference frame was analyzed to understand the source characteristics. Several new concepts, mechanisms and methods are reported for such lobed mixers, such as, "boomerang" scallops, "tongue" mixer, detection of "excess" internal noise sources, and extrapolation of flyover noise data from one flight speed to different flight speeds. Noise reduction of as much as 3 EPNdB was found with a deeply scalloped mixer compared to annular nozzle at net thrust levels of 9500 lb for a 29 in. diameter nozzle after optimizing the nozzle length.

Mengle, Vinod G.↗

NESC GN&C TDT Workshop on 2D Image Motion Optical Transfer Functions, Pointing Performance Analysis, and Requirements

What You Will Learn: The focus is on payload imaging performance due to pointing motion. Some historical background on pointing performance analysis is given. The Optical Transfer Function (OTF) and Modulation Transfer Function (MTF) are defined. The imaging performance due to pointing motion is measured by image motion optical transfer functions (IM OTF). IM OTFs are defined for displacement, smear, and jitter motions, which are all rigorously defined. Deterministic and Statistical IM OTFs are briefly derived and graphically illustrated and compared. The IM OTFs are parameterized by pointing error metrics(PEM), which are means and covariances of displacement, smear, and jitter. Emphasis is on procedures and algorithms to evaluate the image motion optical transfer functions and pointing error metrics. Three procedures are covered, which depend on whether the pointing error data is from time-domain simulation, frequency-domain analysis, or stochastic modeling. A method to evaluate the relative contribution of disturbance sources and to identify the most significant contributors is presented. The presentation includes pertinent discussion of flexible structures and control-structure interaction. No single book can adequately cover this subject, so a book is not required for the course. A list of selected articles, reports, documents, and books is provided for reference and further study. Mathis kept to the minimum necessary to convey principles; lengthy derivations are left to the reference material. Graphics are used to illustrate concepts. As with any such learning endeavor, the knowledge gained will be retained and strengthened through actual practice.c©2019–2021 Mark E. Pittelkau— 5

NASA Engineering and Safety Center (NESC)↗

AE33 Aethalometer Records at RMBL [AMF2] from April 2022 to October 2023

The dataset presents atmospheric mass loadings of black carbon (BC) and brown carbon (BrC), during the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign that took place from 2021 – 2023 in Gothic, CO. A Magee Scientific aethalometer (model AE33) was deployed at the Rocky Mountain Biological Laboratory, 200 m north of AMF2 to monitor mass loadings of optically absorbing aerosols. The instrument inlet was equipped with a BGI SCC 1.829 ambient cyclone with a particle cutoff of 2.5 μm and placed 5 m above ground level. The dataset reports hour-resolved BC mass loadings at 370, 470, 520, 590, 660, 880, and 950 (BC370, BC470, BC 520, BC590, BC660, BC880, BC950 in ng/m3) reported by the instrument built-in algorithm, which calculates mass loadings from the rate of change of the attenuation of light transmitted through the aerosol-laden filter. BC880 is the operationally defined reference of the BC concentration. Hour-resolved absorbance at each wavelength were calculated from their respective mass absorption cross-section in inverse megameters (Mm-1). The absorption Angstrom exponent (AAE) for BrC and BC were calculated for each hour. BrC AAE (AAE_BrC) was calculated from the slope of Log(wavelength) versus Log(absorbance) based on the measurements at 370, 470, and 520 nm. BC AAE (AAE_BrC) was calculated from the slope of Log(wavelength) versus Log(absorbance) based on the measurements at 590, 660, 880, and 950 nm. The aethalometer record spans time periods of 4/5/2022 – 10/3/2022 and 12/8/2022 – 10/9/2023. The ambient CO2 concentration recorded by a Vaisala CARBOCAP carbon dioxide probe GMP343 is also reported in ppm.

54 ENVIRONMENTAL SCIENCES↗

Skylab earth resources experiment package /EREP/ - Sea surface topography experiment

The S-193 Skylab radar altimeter was operated in a round-the-world pass on Jan. 31, 1974. The main purpose of this experiment was to test and 'measure' the variation of the sea surface topography using the Goddard Space Flight Center (GSFC) geoid model as a reference. This model is based upon 430,000 satellite and 25,000 ground gravity observations. Variations of the sea surface on the order of -40 to +60 m were observed along this pass. The 'computed' and 'measured' sea surfaces have an rms agreement on the order of 7 m. This is quite satisfactory, considering that this was the first time the sea surface has been observed directly over a distance of nearly 35,000 km and compared to a computed model. The Skylab orbit for this global pass was computed using the Goddard Earth Model (GEM 6) and S-band radar tracking data, resulting in an orbital height uncertainty of better than 5 m over one orbital period.

Vonbun, F. O.↗

Progress in the development of energy efficient engine components

Component test results are presented for the NASA Energy Efficient Engine program, whose design goals relative to the CF6-50C reference engine include a 12% reduction in specific fuel consumption, 5% reduction in direct operating costs, and 50% reduction in specific fuel consumption deterioration rate over the course of commercial service. Emphasis is placed on the engine's high pressure compressor, which has a design pressure ratio of 23:1, and has completed a series of component tests whose resulting configuration is expected to meet all major objectives of the program. Descriptions are given of the core engine and integrated core/low spool tests, and system test benefits are discussed. Attention is given to the design features of the engine's double annular combustor, high and low pressure air turbines, and scale model exhaust mixer.

Bucy, R. W.↗

Convective Weather Forecast Quality Metrics for Air Traffic Management Decision-Making

Since numerical weather prediction models are unable to accurately forecast the severity and the location of the storm cells several hours into the future when compared with observation data, there has been a growing interest in probabilistic description of convective weather. The classical approach for generating uncertainty bounds consists of integrating the state equations and covariance propagation equations forward in time. This step is readily recognized as the process update step of the Kalman Filter algorithm. The second well known method, known as the Monte Carlo method, consists of generating output samples by driving the forecast algorithm with input samples selected from distributions. The statistical properties of the distributions of the output samples are then used for defining the uncertainty bounds of the output variables. This method is computationally expensive for a complex model compared to the covariance propagation method. The main advantage of the Monte Carlo method is that a complex non-linear model can be easily handled. Recently, a few different methods for probabilistic forecasting have appeared in the literature. A method for computing probability of convection in a region using forecast data is described in Ref. 5. Probability at a grid location is computed as the fraction of grid points, within a box of specified dimensions around the grid location, with forecast convection precipitation exceeding a specified threshold. The main limitation of this method is that the results are dependent on the chosen dimensions of the box. The examples presented Ref. 5 show that this process is equivalent to low-pass filtering of the forecast data with a finite support spatial filter. References 6 and 7 describe the technique for computing percentage coverage within a 92 x 92 square-kilometer box and assigning the value to the center 4 x 4 square-kilometer box. This technique is same as that described in Ref. 5. Characterizing the forecast, following the process described in Refs. 5 through 7, in terms of percentage coverage or confidence level is notionally sound compared to characterizing in terms of probabilities because the probability of the forecast being correct can only be determined using actual observations. References 5 through 7 only use the forecast data and not the observations. The method for computing the probability of detection, false alarm ratio and several forecast quality metrics (Skill Scores) using both the forecast and observation data are given in Ref. 2. This paper extends the statistical verification method in Ref. 2 to determine co-occurrence probabilities. The method consists of computing the probability that a severe weather cell (grid location) is detected in the observation data in the neighborhood of the severe weather cell in the forecast data. Probabilities of occurrence at the grid location and in its neighborhood with higher severity, and with lower severity in the observation data compared to that in the forecast data are examined. The method proposed in Refs. 5 through 7 is used for computing the probability that a certain number of cells in the neighborhood of severe weather cells in the forecast data are seen as severe weather cells in the observation data. Finally, the probability of existence of gaps in the observation data in the neighborhood of severe weather cells in forecast data is computed. Gaps are defined as openings between severe weather cells through which an aircraft can safely fly to its intended destination. The rest of the paper is organized as follows. Section II summarizes the statistical verification method described in Ref. 2. The extension of this method for computing the co-occurrence probabilities in discussed in Section HI. Numerical examples using NCWF forecast data and NCWD observation data are presented in Section III to elucidate the characteristics of the co-occurrence probabilities. This section also discusses the procedure for computing throbabilities that the severity of convection in the observation data will be higher or lower in the neighborhood of grid locations compared to that indicated at the grid locations in the forecast data. The probability of coverage of neighborhood grid cells is also described via examples in this section. Section IV discusses the gap detection algorithm and presents a numerical example to illustrate the method. The locations of the detected gaps in the observation data are used along with the locations of convective weather cells in the forecast data to determine the probability of existence of gaps in the neighborhood of these cells. Finally, the paper is concluded in Section V.

Chatterji, Gano B.↗

Meteorological and Soil Data from Ecohydrology Sensor Towers at Pump House and Snodgrass Mountain in East River Watershed, Colorado, 2019-2025

This data package includes hourly meteorological and soil sensor data at eight ecohydrology monitoring sites in East River Watershed, Colorado as part of the Watershed Function Scientific Focus Area (WFSFA) research led by Lawrence Berkeley National Lab (LBNL). Four field sites were located on the hillslope of East River (ER) near Pump House (PH) at Mount Crested Butte (ER-PHS1 to 4), and the other four are in the Snodgrass Mountain (SG) area (SG-EHS5 to 8). In terms of vegetation cover, three sites are in montane grasslands (ER-PHS1, ER-PHS2, and SG-EHS5), three are below evergreen conifer canopy (ER-PHS3, SG-EHS6, and SG-EHS7), and two are below deciduous aspen canopy (ER-PHS4 and SG-EHS8). The monitoring period began in October 2019 at the East River sites, in October 2020 at SG-EHS5 and SG-EHS6, and in October 2021 at SG-EHS7 and SG-EHS8. In September 2024, all four East River sites were fully retired. The four Snodgrass Mountain sites remain active. Each site is equipped with a comprehensive suite of meteorological sensors on a tripod and soil sensors that measure weather, energy fluxes, and soil variables. This data package includes measurements from ten different types of sensors and up to thirteen individual sensors per site, including (1) a weather station (measurement height ranges from 2.8~3.8 meters (m) above ground), (2) a quantum sensor for photosynthetic active radiation (PAR) (2.4~3.3m), (3) a net radiometer (1.7~2.1m), (4) an infrared radiometer (1.6~2.2m), (5) a sonic distance sensor (1.5~1.9m), (6) a soil carbon dioxide (CO2) flux chamber (0m), (7) a soil heat flux plate (-0.05m below ground), (8) a soil oxygen sensor (-0.3m), (9) a soil water potential sensor (-0.3m), and (10) soil water content sensors at 3~4 depths (-1.15 ~ -0.1m). A total of twenty-three variables is reported in this data package, including (1) atmospheric variables: air temperature (TA), atmospheric pressure (PA), vapor pressure (VP), and vapor pressure deficit (VPD), (2) precipitation variables: rain precipitation (P) and snow depth (D_SNOW), (3) energy fluxes variables: four-component net radiation (NETRAD) (shortwave/longwave incoming/outgoing radiation, SW_IN, SW_OUT, LW_IN, LW_OUT), photosynthetic photon flux density (PPFD), and soil heat flux (G), (4) soil variables: soil water content (SWC), soil water potential (SWP), soil temperature (TS), soil bulk electrical conductivity (COND_SOIL), and soil gaseous oxygen concentration (O2_SOIL), (5) wind variables: two-dimensional wind speed (WS), gust speed (WS_MAX), and wind direction (WD), and (6) surface variables: surface infrared temperature (T_CANOPY) and soil CO2 flux (CO2_SOIL). Please see the Methods section for data processing and QA/QC steps taken to generate the hourly datasets. The following files are included in this data package (notes on version: v{x}-{y}, where x is the metadata version, and y is the data version, when applicable): (1) “metadata_site_v{x}-{y}.csv” - a site metadata file that summarizes location information of all sites, including site ID, description, coordinates, timeframe, elevation, and vegetation cover, (2) “metadata_instrument_v{x}-{y}.csv” - an instrument metadata file that summarizes sensor information of all sites, including sensor manufacturer and model, measurement height, and sampling and averaging interval of all variables, (3) "data_{SITE_ID}_v{x}-{y}.csv" - eight data files that contain hourly data of each site indicated by {SITE_ID} in the filename, (4) “/figure/data_{SITE_ID}_v{x}-{y}.png" - eight figures that help visualize data of each site indicated by {SITE_ID} in the filename, (5) “/photo/*” - photos of each site indicated by {SITE_ID} in the filename, and (6) four file level metadata (flmd.csv) and data dictionary (*_dd.csv) files that summarize file, header, column, and variable information of all files. Notes: (1) Measurement height: Each variable name is followed by conventional positional qualifiers “H_V_R”, where H indicates the relative horizontal positions of that specific variable, V the vertical positions, and R the replicates. In this data package, only the vertical qualifier V varies, and V increases from the highest vertical position (V=1) to the lowest. Variables with the same qualifier are not necessarily measured by the same sensor, and the same variable with the same qualifier across different sites are not necessarily measured at the same height. Please refer to “metadata_instrument.csv” for the sensor information and measurement heights, and whether a variable is measured below the canopy. (2) Variable availability: Snow depth is not available at ER-PHS3 and SG-EHS7. SWC, soil temperature, and soil bulk EC at the deepest depth (<-1m) are not available at SG-EHS6 and SG-EHS7. The missing value code for numeric variables is -9999, except for SWP. For SWP, the missing value code is +9999, because SWP values are negative. (3) Sampling frequency: Please refer to “metadata_instrument.csv” for the increase of sampling frequency of some variables from 30-min to 1-min at ER-PHS1 to 4 in July 2020. (4) Sensors: While the methods of each sensor are not detailed, all sensors are commercially available, and their methods can be found in their manuals. Please refer to “metadata_instrument.csv” for the sensor manufacturer and model information. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

TOPLA: A New Empirical Representation of the F-Region Topside and Plasmasphere for the International Reference Ionosphere

The goal of this LWS tools effort is the development of a new data-based F-region TOpside and PLAsmasphere (TOPLA) model for the electron density (Ne) and temperature (Te) for inclusion in the International Reference Ionosphere (IRI) model using newly available satellite data and models for these regions. The IRI model is the de facto international standard for specification of ionospheric parameters and is currently being considered as an ISO Technical Specification for the ionosphere. Our effort is directed towards improving the topside part of the model and extending it into the plasmasphere. Specifically we are planning to overcome the following shortcomings of the current IRI topside model: (I) overestimation of densities above 700 km by a factor of 2 and more, (3) unrealistically steep density profiles at high latitudes during very high solar activities, (4) no solar cycle variations and no semi-annual variations for the electron temperature, (5) discontinuities or unphysical gradients when merging with plasmaspheric models. We will report on first accomplishments and on the current status of the project.

Bilitza, D.↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system

Purpose: In radiochromic film dosimetry systems, measurements are usually obtained from film images acquired on a CCD-based flatbed scanner. The authors investigated factors affecting scan-to-scan response variability leading to increased dose measurement uncertainty. Methods: The authors used flatbed document scanners to repetitively scan EBT3 radiochromic films exposed to doses 0–1000 cGy, together with three neutral density filters and three blue optical filters. Scanning was performed under two conditions: scanner lid closed and scanner lid opened/closed between scans. The authors also placed a scanner in a cold room at 9 °C and later in a room at 22 °C and scanned EBT3 films to explore temperature effects. Finally, the authors investigated the effect of altering the distance between the film and the scanner’s light source. Results: Using a measurement protocol to isolate the contribution of the CCD and electronic circuitry of the scanners, the authors found that the standard deviation of response measurements for the EBT3 film model was about 0.17% for one scanner and 0.09% for the second. When the lid of the first scanner was opened and closed between scans, the average scan-to-scan difference of responses increased from 0.12% to 0.27%. Increasing the sample temperature during scanning changed the RGB response values by about −0.17, −0.14, and −0.05%/°C, respectively. Reducing the film-to-light source distance increased the RBG response values about 1.1, 1.3, and 1.4%/mm, respectively. The authors observed that films and film samples were often not flat with some areas up to 8 mm away from the scanner’s glass window. Conclusions: In the absence of measures to deal with the response irregularities, each factor the authors investigated could lead to dose uncertainty >2%. Those factors related to the film-to-light source distance could be particularly impactful since the authors observed many instances where the curl of film samples had the potential to cause dose uncertainty in excess of 5%. Two expedients will eliminate the uncertainties: a transparent sheet (preferably glass) placed over the scanned film keeps the film-to-light source distance constant, and an EBT3 reference film included in all scans provides correction factors for measured response values.

60 APPLIED LIFE SCIENCES↗

A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning

Monte Carlo (MC) simulation is currently the most accurate dose calculation algorithm in radiotherapy planning but requires relatively long processing time. Faster model-based algorithms such as the anisotropic analytical algorithm (AAA) by the Eclipse treatment planning system and multigrid superposition (MGS) by the XiO treatment planning system are 2 commonly used algorithms. This study compared AAA and MGS against MC, as the gold standard, on brain, nasopharynx, lung, and prostate cancer patients. Computed tomography of 6 patients of each cancer type was used. The same hypothetical treatment plan using the same machine and treatment prescription was computed for each case by each planning system using their respective dose calculation algorithm. The doses at reference points including (1) soft tissues only, (2) bones only, (3) air cavities only, (4) soft tissue-bone boundary (Soft/Bone), (5) soft tissue-air boundary (Soft/Air), and (6) bone-air boundary (Bone/Air), were measured and compared using the mean absolute percentage error (MAPE), which was a function of the percentage dose deviations from MC. Besides, the computation time of each treatment plan was recorded and compared. The MAPEs of MGS were significantly lower than AAA in all types of cancers (p<0.001). With regards to body density combinations, the MAPE of AAA ranged from 1.8% (soft tissue) to 4.9% (Bone/Air), whereas that of MGS from 1.6% (air cavities) to 2.9% (Soft/Bone). The MAPEs of MGS (2.6%±2.1) were significantly lower than that of AAA (3.7%±2.5) in all tissue density combinations (p<0.001). The mean computation time of AAA for all treatment plans was significantly lower than that of the MGS (p<0.001). Both AAA and MGS algorithms demonstrated dose deviations of less than 4.0% in most clinical cases and their performance was better in homogeneous tissues than at tissue boundaries. In general, MGS demonstrated relatively smaller dose deviations than AAA but required longer computation time.

61 RADIATION PROTECTION AND DOSIMETRY↗

New contactless method for thermal diffusivity measurements using modulated photothermal radiometry

Modulated photothermal radiometry is a non-destructive and contactless technique for the characterization of materials. It has two major advantages: a good signal-to-noise ratio through a synchronous detection and a low dependence on the heating power and the optical properties of the sample surface. This paper presents a new method for characterizing the thermal diffusivity of a material when the phase shift between a modulated laser power signal and the thermal signal of a plate sample is known at different frequencies. The method is based on a three-dimensional analytical model which is used to determine the temperature amplitude and the phase in the laser heating of the plate. A new simple formula was developed through multi-parametric analysis to determine the thermal diffusivity of the plate with knowledge of the frequency at the minimum phase shift, the laser beam radius r{sub 0} and the sample thickness L. This method was developed to control the variation of the thermal diffusivity of nuclear components and it was first applied to determine the thermal diffusivity of different metals: 304 L stainless steel, nickel, titanium, tungsten, molybdenum, zinc, and iron. The experimental results were obtained with 5%–10% accuracy and corresponded well with the reference values. The present paper also demonstrates the limit of application of this method for plate with thickness r{sub 0}/100 ≤ L ≤ r{sub 0}/2. The technique is deemed interesting for the characterization of barely accessible components that require a contactless measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Closures for Nonlinear Fluid Simulations of Plasmas (Final Report)

Advanced Closures for Nonlinear Fluid Simulations of Plasmas E. Held, Utah State University (Principal Investigator) J.-Y. Ji, Utah State University (Co-Investigator) Utah State University (USU) continued to develop and apply closures for hybrid fluid/kinetic simulations of magnetized fusion plasmas. The closures developed by USU's fusion theory and computation group use the drift ordering and are referred to as "continuum" and "general moment" approaches. They differ in their representation for the distribution functions which probabilistically describe the density of particles in 5 dimensional phase space. The two chosen velocity variables, needed in studies of kinetic physics for magnetized plasmas, are the speed and the component of a particle's velocity along the magnetic field. In magnetized plasmas, the charged particle trajectories are tied closely to the magnetic field lines. Both approaches account for binary interactions between particles using the Coulomb collision operator. Theoretical and computational development along both lines provided avenues for verification between the two approaches. This funding allowed USU to further develop physically accurate and numerically efficient models that advance our understanding of kinetic physics in experiments like the International Thermonuclear Experimental Reactor (ITER). The ITER device will likely prove the physical practicality of thermonuclear fusion by producing 500 megawatts of clean, abundant fusion power. This work helped to realize this goal by advancing our simulation capability using hybrid fluid/kinetic models.