Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Techniques used for the analysis of oculometer eye-scanning data obtained from an air traffic control display

The methodology and techniques used to collect and analyze look-point position data from a real-time ATC display-format comparison experiment are documented. That study compared the delivery precision and controller workload of three final approach spacing aid display formats. Using an oculometer, controller lookpoint position data were collected, associated with gaze objects (e.g., moving aircraft) on the ATC display, and analyzed to determine eye-scan behavior. The equipment involved and algorithms for saving, synchronizing with the ATC simulation output, and filtering the data are described. Target (gaze object) and cross-check scanning identification algorithms are also presented. Data tables are provided of total dwell times, average dwell times, and cross-check scans. Flow charts, block diagrams, file record descriptors, and source code are included. The techniques and data presented are intended to benefit researchers in other studies that incorporate non-stationary gaze objects and oculometer equipment.

Crawford, Daniel J.↗

Mechanical and electrical changes in electrochemically active polyimide binders for Li-ion batteries

Polyimide binders are often used in electrodes made with silicon for lithium-ion batteries for their mechanical strength and adhesion, which help mitigate mechanical issues associated with large volumetric expansion. These binders can be electrochemically active, but it is difficult to characterize what physical and chemical changes occur due to a composite electrode with multiple components and processes at play. Here, in this work, we study electrodes consisting only of polyimide binder and conductive carbon, using scanning probe-based techniques—contact resonance, force volume, and scanning spreading resistance microscopy—along with cryo-scanning transmission electron microscopy, electron energy loss spectroscopy, and energy dispersive X-ray spectroscopy. We show that lithium becomes trapped in the binder during cycling and results in large initial capacity losses, the formation of dendrite-like features, column-like domains of significantly increased mechanical modulus, and a slight increase in electronic resistivity.

25 ENERGY STORAGE↗

Advanced techniques in automated high-resolution scanning transmission electron microscopy

Scanning transmission electron microscopy is a common tool used to study the atomic structure of materials. It is an inherently multimodal tool allowing for the simultaneous acquisition of multiple information channels. Despite its versatility, however, experimental workflows currently rely heavily on experienced human operators and can only acquire data from small regions of a sample at a time. Here, we demonstrate a flexible pipeline-based system for high-throughput acquisition of atomic-resolution structural data using an all-piezo sample stage applied to large-scale imaging of nanoparticles and multimodal data acquisition. As a result, the system is available as part of the user program of the Molecular Foundry at Lawrence Berkeley National Laboratory.

4D-STEM↗

Flight evaluation of advanced navigation techniques for general aviation using frequency scanning

Experiments on an automatic multisensor navigation concept are being conducted in a Cessna 402B. The test system consists of VOR, DME, and air data sensors controlled by a Hewlett Packard 9820A electronic calculator which processes the data and, by means of a four-state Kalman filter, outputs position and ground and wind velocities to a map display. Novel features which make such a system potentially low-cost include frequency-scanning operation of a single VOR receiver and a single DME transceiver and use of a shed-vortex true airspeed sensor. Results obtained during flight in a local area where six to eight DME NAVAIDS were receivable yielded better than 1/4-mile accuracy.

Jackson, C. T., Jr.↗

Quantitative nondestructive evaluation of materials and structures

An experimental investigation was undertaken to quantify damage tolerance and resistance in composite materials impacted using the drop-weight method. Tests were conducted on laminates of several different carbon-fiber composite systems, such as epoxies, modified epoxies, and amorphous and semicrystalline thermoplastics. Impacted composite specimens were examined using destructive and non-destructive techniques to establish the characteristic damage states. Specifically, optical microscopy, ultrasonic, and scanning electron microscopy techniques were used to identify impact induced damage mechanisms. Damage propagation during post impact compression was also studied.

Smith, Barry T.↗

Correlation-based technique for automated tunable diode laser scan stabilization

A software-based method for real-time, active stabilization of tunable diode laser spectral scans is described. The procedure is suitable for use with field and laboratory instrumentation where automated, unattended spectrometer operation is required. An autocorrelation of two high-resolution reference gas infrared spectra is computed at regular intervals, and the location of the maximum value of the autocorrelation provides the relative abscissa shift between the spectra. Small adjustments to the laser scan parameters are thereby made to ensure that drifts in the laser output frequency are tracked and compensated. Calculations required for stabilization of a 512-point spectrum can be completed in under 25 ms using an inexpensive, moderate-speed, array processor installed in a PC.

May, Randy D.↗

Characterization of damage modes in impacted thermoset and thermoplastic composites

Composite materials remain extremely vulnerable to out-of-plane impact loads, which may lead to severe losses in strength and stiffness. Impact induced damage is often a complex mixture of transverse cracks, delaminations and fiber failures. An experimental investigation was undertaken to quantify damage tolerance and resistance in composite materials impacted using the drop-weight method. Tests were conducted on laminates of several different carbon-fiber composite systems such as epoxies, modified epoxies, and amorphous and semicrystalline thermoplastics. In this paper, impacted composite specimens have been examined using destructive and nondestructive techniques to establish the characteristic damage states. Specifically, optical microscopy, ultrasonic and scanning electron microscopy techniques have been used to identify impact induced damage mechanisms. Damage propagation during post impact compression was also studied.

Srinivasan, K.↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Systems for ultrasonic scanning, analysis and imagery

A variety of ultrasonic scanning and imagery techniques are used to investigate various aspects of materials and microstructures. Two ultrasonic scanning systems are in use by the Lewis Research Center's Structural Integrity Branch: an immersion scanner and a contact scanning system. The basic principles of scanning are reviewed, examples of images are presented, and structural features suggested by these images are discussed. Both of these systems are custom designed; their capabilities, advantages, and disadvantages are highlighted.

Stang, David B.↗

Mutual coupling between parallel columns of periodic slots in a ground plane surrounded by dielectric slabs

Arrays of slots with arbitrary orientation in a conducting plane which are infinitely periodic in one dimension and finitely periodic in another dimension are considered. The perfect conducting plane extends infinitely and is bounded on each side by dielectric slabs of finite thickness and infinite extent. Single columns of slots are represented by equivalent magnetic scattering currents, which are solved for via the moment method. The mutual coupling (admittance) between slot columns in the presence of the stratified media is found by the array scanning method (ASM), which expresses the admittance as the average of the scan admittance of an artificially constructed doubly infinite array of slots over all real scan angles. The technique avoids the use of Sommerfeld integrals, but still gives rise to singularities at scan angles corresponding to the resonant excitation of surface waves. An analytical approximation is made to remove these surface wave singularities, thus making numerical implementation of the method practical. The method is quite general and may be extended to thin slot elements of arbitrary shape and orientation.

Skinner, J. P.↗

Measuring Roughnesses Of Optical Surfaces

Report discusses use of scanning tunneling microscopy and atomic force microscopy to measure roughnesses of optical surfaces. These techniques offer greater spatial resolution than other techniques. Report notes scanning tunneling microscopes and atomic force microscopes resolve down to 1 nm.

Coulter, Daniel R.↗

Fracture, failure and compression behaviour of a 3D interconnected carbon aerogel (Aerographite) epoxy composite

Aerographite (AG) is a mechanically robust, lightweight synthetic cellular material, which consists of a 3D interconnected network of tubular carbon [1]. The presence of open channels in AG aids to infiltrate them with polymer matrices, thereby yielding an electrical conducting and lightweight composite. Aerographite produced with densities in the range of 7–15 mg/cm 3 was infiltrated with a low viscous epoxy resin by means of vacuum infiltration technique. Detailed morphological and structural investigations on synthesized AG and AG/epoxy composite were performed by scanning electron microscopic techniques. Our present study investigates the fracture and failure of AG/epoxy composites and its energy absorption capacity under compression. The composites displayed an extended plateau region when uni-axially compressed, which led to an increase in energy absorption of ~133% per unit volume for 1.5 wt% of AG, when compared to pure epoxy. Preliminary results on fracture toughness showed an enhancement of ~19% in K IC for AG/epoxy composites with 0.45 wt% of AG. Furthermore, our observations of fractured surfaces under scanning electron microscope gives evidence of pull-out of arms of AG tetrapod, interface and inter-graphite failure as the dominating mechanism for the toughness improvement in these composites. These observations were consistent with the results obtained from photoelasticity experiments on a thin film AG/epoxy model composite.

36 MATERIALS SCIENCE↗

Investigations of room temperature multiferroic and magneto-electric properties of (1-Φ) PZTFT-Φ CZFMO particulate composites

Multiferroic composites consisting of a single-phase multiferroic [0.6(PbZr 0.53 Ti 0.47 O 3 )-0.4(PbFe 0.5 Ta 0.5 )O 3 ] as a matrix and a magnetostrictive phase (Co 0.6 Zn 0.4 Fe 1.7 Mn 0.3 O 4 ) dispersed in the matrix are fabricated via hybrid synthesis technique. The structure and surface morphology studies using x-ray diffraction and field emission scanning electron microscopy techniques indicate the formation of 3-0 type particulate composites. Coexistence of soft-magnetic behavior and ferroelectric characteristics are confirmed for composites from magnetization vs magnetic field (M–H) and polarization vs electric field (P–E) measurements, respectively. Magneto-dielectric (MD) measurement shows significant changes in the dielectric properties with the application of a magnetic field, indicating the existence of strong MD behavior. The biquadratic nature of magneto-electric (ME) coupling is described by the Landau free energy equation arising from the strain transfer at the interfaces between the constituent phases. The direct magneto-electric voltage coefficient measurement also confirms very strong coupling between ferroelectricity and magnetism and supports the strain-mediated magneto-electric effect in composites. The Φ = 0.3 composite exhibits the maximum ME coefficient of 20.72 mV/cm Oe with M S = 24.62 emu/g, H C = 59.66 Oe, and piezoelectric coefficient value d 33 = 19 pC/N. In conclusion, the strong magneto-electric effect along with low dielectric loss at room temperature in these composites suggests their suitability for multifunctional magneto-electric device applications such as magnetic sensors, etc.

36 MATERIALS SCIENCE↗

TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CT dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.

60 APPLIED LIFE SCIENCES↗

Rain volume estimation over areas using satellite and radar data

The feasibility of rain volume estimation over fixed and floating areas was investigated using rapid scan satellite data following a technique recently developed with radar data, called the Area Time Integral (ATI) technique. The radar and rapid scan GOES satellite data were collected during the Cooperative Convective Precipitation Experiment (CCOPE) and North Dakota Cloud Modification Project (NDCMP). Six multicell clusters and cells were analyzed to the present time. A two-cycle oscillation emphasizing the multicell character of the clusters is demonstrated. Three clusters were selected on each day, 12 June and 2 July. The 12 June clusters occurred during the daytime, while the 2 July clusters during the nighttime. A total of 86 time steps of radar and 79 time steps of satellite images were analyzed. There were approximately 12-min time intervals between radar scans on the average.

Doneaud, A. A.↗

Identifying the Accuracy of Surface Roughness for Metal Additive Manufacturing Parts Captured with Computed Tomography Scanning

Conventional surface roughness measurement techniques require direct access to internal surfaces, often necessitating destructive sectioning of test articles. Computed tomography (CT) offers a non-destructive alternative for internal surface characterization, but its application in metrology remains unstandardized and sensitive to machine resolution and operator technique. This study investigates the feasibility of using CT scanning to quantify areal surface roughness in metal AM heat exchanger tubes with three distinct internal geometries: ribbed, discrete W, and featureless. CT-derived surface parameters were extracted using custom Python scripts and compared to measurements obtained from a focus variation microscope calibrated against a known standard. Results show that CT-based roughness measurements closely matched microscope values for the discrete W specimen, deviations between CT and microscope measurements were minimal—less than 1 µm—indicating reliable reconstruction. In contrast, the ribbed and featureless specimens, with lower roughness values showed greater discrepancies. The findings suggest that CT scanning can be a viable non-destructive metrology tool for AM parts with surface roughness above approximately 8 µm. For smoother surfaces, current CT capabilities may not provide sufficient accuracy, highlighting the need for resolution-aware workflows and further standardization in CT-based surface metrology.

36 MATERIALS SCIENCE↗

In-line monitoring of Li-ion battery electrode porosity and areal loading using active thermal scanning - modeling and initial experiment

This work focuses on a new technique called active thermal scanning for in-line monitoring of porosity and areal loading of Li-ion battery electrodes. In this technique a moving battery electrode is subjected to thermal excitation and the induced temperature rise is monitored using an infra-red camera. Static and dynamic experiments with speeds up to 1.5 m min -1 are performed on both cathodes and anodes and a combined micro- and macro-scale finite element thermal model of the system is developed. It is shown experimentally and through simulations that during thermal scanning the temperature profile generated in an electrode depends on both coating porosity (or area loading) and thickness. Here, it is concluded that by inverting this relation the porosity (or areal loading) can be determined, if thermal response and thickness are simultaneously measured.

25 ENERGY STORAGE↗

Improved reconstruction and sensing techniques for personnel screening in three-dimensional cylindrical millimeter-wave portal scanning

The cylindrical millimeter-wave imaging technique, developed at Pacific Northwest National Laboratory (PNNL) and commercialized by L-3 Communications/Safeview in the ProVision system, is currently being deployed in airports and other high security locations to meet person-borne weapon and explosive detection requirements. While this system is efficient and effective in its current form, there are a number of areas in which the detection performance may be improved through using different reconstruction algorithms and sensing configurations. PNNL and Northeastern University have teamed together to investigate higher-order imaging artifacts produced by the current cylindrical millimeter-wave imaging technique using full-wave forward modeling and laboratory experimentation. Based on imaging results and scattered field visualizations using the full-wave forward model, a new imaging system is proposed. The new system combines a multistatic sensor configuration with the generalized synthetic aperture focusing technique (GSAFT). Initial results show an improved ability to image in areas of the body where target shading, specular and higher-order reflections cause images produced by the monostatic system difficult to interpret.

99 GENERAL AND MISCELLANEOUS↗