Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Signal Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Learning the Temporal Effect in Infrared Thermal Videos With Long Short-Term Memory for Quality Prediction in Resistance Spot Welding

With the advances of sensing technology, in-situ infrared thermal videos can be collected from Resistance Spot Welding (RSW) processes. Each video records the formulation process of a weld nugget. The nugget evolution creates a “temporal effect” across the frames, which can be leveraged for real-time, nondestructive evaluation (NDE) of the weld quality. Currently, quality prediction with imaging data mainly focuses on optical feature extraction with Convolutional Neural Network (CNN) but does not make the most of such temporal effect. In this study, pixels corresponding to critical locations on the weld nugget surface are extracted from a video to form multivariate time series (MTS). Multivariate Adaptive Regression Splines (MARS) is used in MTS processing to remove noisy signals related to uninformative frames. A Stacked Long Short-Term Memory (LSTM) model is developed to learn from the processed MTS and then predicts weld nugget size and thickness in real-time NDE. Results from a case study on RSW of Boron steel demonstrates the improvement in prediction accuracy and computational time with the proposed method, as compared to CNN-based weld quality prediction.

Guo, Shenghan↗

Model-based approach to investigate equipment-induced error in pressure-waveform derived hemodynamic measurements

Advanced hemodynamic monitoring systems have provided less invasive methods for estimating pressure-derived measurements such as pressure-derived cardiac output (CO) measurements. These devices apply algorithms to arterial pressure waveforms recorded via pressure recording components that transmit the pressure signal to a pressure monitor. While standards have been developed for pressure monitoring equipment, it is unclear how the equipment-induced error can affect secondary measurements from pressure waveforms. We propose an approach for modelling different components of a pressure monitoring system and use this model-based approach to investigate the effect of different pressure recording configurations on pressure-derived hemodynamic measurements. The proposed model-based approach is a three-step process. (1) Modelling the response of pressure recording components using bench tests; (2) verifying the identified models through nonparametric equivalence tests; and (3) assessing the effects of pressure recording components on pressure-derived measurements. To delineate the application of this approach, we performed a series of model-based analyses to quantify the combined effect of a wide range of tubing configurations with various damping ratios and natural frequencies and monitors with different bandwidths on pressure waveforms and CO measurements by six pulse contour algorithms. Model-based results show the error in pressure-derived CO measurements because of tubing configurations with different natural frequencies and damping ratios. Tubing configurations with low natural frequencies (<23 Hz) altered characteristics of pressure waveforms in a way that affected the CO measurement, some by as much as 20%. Our method can serve as a tool to quantify the performance of pressure recording systems with different dynamic properties. In conclusion, this approach can be applied to investigate the effects of physiologic signal recording configurations on various pressure-derived hemodynamic measurements.

42 ENGINEERING↗

TPSAS-NF1676L-34013-DND

Currently, many experiments pursuing comprehensive characterization of the atmosphere include coordinated observations by both lidar and polarimeters in order to obtain important complimentary information about aerosol properties. The most advanced passive observations by space-based multi-angle polarimeters are sensitive to the properties of aerosol in total atmospheric column, but have very limited sensitivity to vertical structure of the atmosphere. Polarimeter observations can be used not only for retrieval of aerosol optical thickness, but also for deriving microphysical information about aerosol particle shape, size distribution, complex refractive index, and the properties of underlying surface (Dubovik et al., 2019). In a contrast, the lidar observations of atmospheric responses from different altitudes to laser pulses are designed to provide vertical profiles of atmospheric characteristics. Here we present the recent advancement in GRASP algorithm (Generalized Aerosol Retrieval of Atmospheric and Surface Properties) (Dubovik et al., 2011, 2014) that allows simultaneous inversion of co-incident lidar and polarimeter spaceborne observations and derives a united set of vertically resolved aerosol and surface parameters. Such synergetic retrieval is an extension to satellite data of the approach for synergetic processing of active and passive measurements developed earlier by (Lopatin et al., 2013) for ground-based observations. Another addition to these developments is the inclusion of Raman-shifted and volume depolarization backscattering observations that improve sensitivity to the vertical properties of aerosol, while polarimetric observations provide sufficient constraints on aerosol type and loading that generally are missing in lidar signals. The potential and limitations of such synergetic processing is illustrated by application to co-incident PARASOL and CALIPSO data.

Anton Lopatin↗

The interactions of peripheral membrane proteins with biological membranes

The interactions of peripheral proteins with membrane surfaces are critical to many biological processes, including signaling, recognition, membrane trafficking, cell division and cell structure. On a molecular level, peripheral membrane proteins can modulate lipid composition, membrane dynamics and protein-protein interactions. Biochemical and biophysical studies have shown that these interactions are in fact highly complex, dominated by several different types of interactions, and have an interdependent effect on both the protein and membrane. Here we examine three major mechanisms underlying the interactions between peripheral membrane proteins and membranes: electrostatic interactions, hydrophobic interactions, and fatty acid modification of proteins. While experimental approaches continue to provide critical insights into specific interaction mechanisms, emerging bioinformatics resources and tools contribute to a systems-level picture of protein-lipid interactions. Through these recent advances, we begin to understand the pivotal role of protein-lipid interactions underlying complex biological functions at membrane interfaces.

60 APPLIED LIFE SCIENCES↗

Hydrogen density mapping in biomolecular crystals through dynamic nuclear polarization

Many fundamental biological processes, including those in photosynthetic reaction centers and enzyme active sites, involve charge and energy transfer, bond cleavage, protonation and hydrogen bonding. Because H atoms play such central roles in these reactions, accurately determining their positions is essential. Yet, conventional X-ray crystallography primarily resolves the heavy atoms in biological structures and provides limited insight into hydrogen, even at atomic resolution. Neutron macromolecular crystallography (NMC) overcomes this limitation by offering exceptional sensitivity to hydrogen and deuterium. Here, we present a theoretical framework for the development of dynamic nuclear polarization NMC (DNP-NMC) techniques, which exploit the alignment of neutron and proton nuclear spins to enhance and tune the hydrogen signal contribution. The DNP-NMC approach advances the resolution of H atoms within biomolecular crystals, whether bound to protein residues or present in solvent. The method establishes key relationships for the coherent structure factor of polarized neutron scattering from hydrogenous matter. It theoretically achieves full accuracy in phase reconstruction and offers a path to improve neutron structure determination, achieving accuracies exceeding ≳80% by incorporating titration states. Using a variant of the hybrid input/output phase-retrieval algorithm, it allows recovery of the hydrogen density with ≳90% phase accuracy. In conclusion, we further discuss sources of experimental uncertainty for the upcoming DNP-enabled, quasi-Laue IMAGINE-X experiment at Oak Ridge National Laboratory's High Flux Isotope Reactor.

dynamic nuclear polarization↗

Proteomic insights into the physiology and metabolism of oleaginous yeasts and filamentous fungi

Fungi are vital to the bioeconomy, serving as key producers of food, beverages, biofuels, and medicines, while also acting as essential resource recyclers in ecosystem management. For nearly a century, oleaginous yeast and filamentous fungi have been explored for their proficiency in oleochemicals production and carbon storage. Lipogenesis is one of the most well-studied fungal processes, with substantial progress having been made through reductionist biochemical approaches; however, the physiology and metabolism of fungal systems operating under different conditions arise from the functions of thousands of proteins, for which very little is known outside of model yeast. In this review, we discuss how proteomics provides a valuable analytical approach to contextualize lipogenesis within a complex biological system, where lipid accumulation is fundamentally governed by changes in proteins of multiple pathways. In the past two decades, proteomics has been applied to study stress response to nutrient limitations, metabolism of various carbon and nitrogen sources, the lipid droplet hub of carbon storage, protein post-translational modifications and signaling pathways, as well as oleochemical biosynthesis, thereby advancing our understanding of the oleaginous phenotype. Over 40 studies are reviewed herein to evaluate the impact, critically assess the utility, and propose future applications of proteomics. In the coming years, large systems-level proteomics studies will lay a foundation for marrying modeling and metabolic engineering strategies to optimize oleochemicals production in oleaginous fungi.

Lipid production↗

Acoustic Characterization of the NASA Langley 14- by 22-Foot Subsonic Tunnel Using Single-Microphone Analysis Techniques

An experimental campaign was conducted to assess recent acoustic modifications to the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. This effort was undertaken in preparation for future rotorcraft, Advanced Air Mobility, and airframe noise acoustic tests. The tunnel is a closed circuit and typically operates in an open-jet configuration for acoustic studies. A vertical linear array of microphones and a phased array were placed on traverses outside of the core flow. Pole-mounted acoustic sources with known waveforms were used to identify reflective surfaces under static conditions with no tunnel flow. A similar process was replicated with more compact sources in an aerodynamic fairing for flow speeds up to Mach 0.16. This enabled investigation of the test section core flow and bounding shear layer impacts on the acoustic measurements. Periodic averaging was employed and was shown to be capable of isolating periodic acoustic signals even for poor signal-to-noise ratio conditions. Benefits and limitations of single-microphone processing methods are identified. A companion paper utilizes a phased array in an effort to address the identified limitations to more traditional single-microphone data collection.

Acoustic Characterization↗

Acoustic Characterization of the NASA Langley 14- by 22-Foot Subsonic Tunnel Using Single-Microphone Analysis Techniques

An experimental campaign was conducted to assess recent acoustic modifications to the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. This effort was undertaken in preparation for future rotorcraft, Advanced Air Mobility, and airframe noise acoustic tests. The tunnel is a closed circuit and typically operates in an open-jet configuration for acoustic studies. A vertical linear array of microphones and a phased array were placed on traverses outside of the core flow. Pole-mounted acoustic sources with known waveforms were used to identify reflective surfaces under static conditions with no tunnel flow. A similar process was replicated with more compact sources in an aerodynamic fairing for flow speeds up to Mach 0.16. This enabled investigation of the test section core flow and bounding shear layer impacts on the acoustic measurements. Periodic averaging was employed and was shown to be capable of isolating periodic acoustic signals even for poor signal-to-noise ratio conditions. Benefits and limitations of single-microphone processing methods are identified. A companion paper utilizes a phased array in an effort to address the identified limitations to more traditional single-microphone data collection.

Acoustic Characterization↗

Cryogenic hybrid magnonic circuits based on spalled YIG thin films

Yttrium iron garnet (YIG) magnonics has garnered significant research interest because of the unique properties of magnons (quasiparticles of collective spin excitation) for signal processing. In particular, hybrid systems based on YIG magnonics show great promise for quantum information science due to their broad frequency tunability and strong compatibility with other platforms. However, their broad applications have been severely constrained by substantial microwave loss in the gadolinium gallium garnet (GGG) substrate at cryogenic temperatures. In this study, we demonstrate that YIG thin films can be spalled from YIG/GGG samples. Our approach is validated by measuring hybrid devices comprising superconducting resonators and spalled YIG films, which exhibit anti-crossing features that indicate strong coupling between magnons and microwave photons. Such new capability of separating YIG thin films from GGG substrates via spalling and the integrated superconductor-YIG devices represent a significant advancement for integrated magnonic devices, paving the way for advanced magnon-based coherent information processing.

36 MATERIALS SCIENCE↗

Chatbots can guide experimentalists to avoid many common mistakes in measuring fluorescence spectra

The concepts of fluorescence spectroscopy are well established, yet the experimental collection of a spectrum is susceptible to a range of errors. A recent study showed that chatbots – derived from substantial advances in artificial intelligence – can provide practical assistance to the experimentalist during collection of absorption spectra and thereby achieve improved quality. Fluorescence, while the complement of absorption, is prone to a far richer array of experimental errors encompassing environmental factors, instrumental settings, and experimentalist mistakes. Here, 10 chatbots (ChatGPT 5, Gemini 2.5 Pro, Microsoft Copilot, Meta AI Llama 4, Claude Sonnet 4.5, X.ai Grok 4, Perplexity Pro, DeepSeek V3.1, Z.ai GLM-4.6, and KIMI K2) have been evaluated for the suitability in providing quality-improvement advice to the experimentalist during acquisition of fluorescence spectra. Significant opportunities for practical assistance are noted, although intervention by a domain expert is often required. Here, if combined with image recognition and/or signal processing, chatbots embedded in instruments may enable real-time guidance during fluorescence data acquisition.

Artificial intelligence↗

Hardware requirements: A new generation partial reflection radar for studies of the equatorial mesosphere

A new partial reflection (PR) radar is being developed for operation at the proposed Equatorial Observatory. The system is being designed to make maximum use of recent advances in solid-state technology in order to minimize the power requirements. In particular, it is planned to use a solid-state transmitter in place of the tube transmitters previously used in PR systems. Solid-state transmitters have the advantages that they do not need high voltage supplies, they do not require cathode heaters with a corresponding saving in power consumption and parts are readily available and inexpensive. It should be possible to achieve 15 kW peak powers with recently announced fast switching transistors. Since high mean powers are desirable for obtaining good signal-to-noise ratios, it is also planned to phase code the transmitted pulses and decode after coherent integration. All decoding and signal processing will be carried out in dedicated microprocessors before the signals are passed to a microcomputer for on-line analysis. Recent tests have shown that an Olivetti M24 micro (an IBM compatible) running an 8-MHz clock with a 8087 coprocessor can analyze data at least as fast as the minicomputers presently being used with the Adelaide PR rad ar and at a significantly lower cost. The processed winds data will be stored in nonvolatile CMOS RAM modules; about 0.5 to 1 Mbyte is required to store one week's information.

Vincent, R. A.↗

Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

Purpose: Aims in this study are to (1) develop a computational model observer which reliably tracks the detectability of human observers in low dose computed tomography (CT) images reconstructed with knowledge-based iterative reconstruction (IMR™, Philips Healthcare) and filtered back projection (FBP) across a range of independent variables, (2) use the model to evaluate detectability trends across reconstructions and make predictions of human observer detectability, and (3) perform human observer studies based on model predictions to demonstrate applications of the model in CT imaging. Methods: Detectability (d′) was evaluated in phantom studies across a range of conditions. Images were generated using a numerical CT simulator. Trained observers performed 4-alternative forced choice (4-AFC) experiments across dose (1.3, 2.7, 4.0 mGy), pin size (4, 6, 8 mm), contrast (0.3%, 0.5%, 1.0%), and reconstruction (FBP, IMR), at fixed display window. A five-channel Laguerre–Gauss channelized Hotelling observer (CHO) was developed with internal noise added to the decision variable and/or to channel outputs, creating six different internal noise models. Semianalytic internal noise computation was tested against Monte Carlo and used to accelerate internal noise parameter optimization. Model parameters were estimated from all experiments at once using maximum likelihood on the probability correct, P{sub C}. Akaike information criterion (AIC) was used to compare models of different orders. The best model was selected according to AIC and used to predict detectability in blended FBP-IMR images, analyze trends in IMR detectability improvements, and predict dose savings with IMR. Predicted dose savings were compared against 4-AFC study results using physical CT phantom images. Results: Detection in IMR was greater than FBP in all tested conditions. The CHO with internal noise proportional to channel output standard deviations, Model-k4, showed the best trade-off between fit and model complexity according to AIC{sub c}. With parameters fixed, the model reasonably predicted detectability of human observers in blended FBP-IMR images. Semianalytic internal noise computation gave results equivalent to Monte Carlo, greatly speeding parameter estimation. Using Model-k4, the authors found an average detectability improvement of 2.7 ± 0.4 times that of FBP. IMR showed greater improvements in detectability with larger signals and relatively consistent improvements across signal contrast and x-ray dose. In the phantom tested, Model-k4 predicted an 82% dose reduction compared to FBP, verified with physical CT scans at 80% reduced dose. Conclusions: IMR improves detectability over FBP and may enable significant dose reductions. A channelized Hotelling observer with internal noise proportional to channel output standard deviation agreed well with human observers across a wide range of variables, even across reconstructions with drastically different image characteristics. Utility of the model observer was demonstrated by predicting the effect of image processing (blending), analyzing detectability improvements with IMR across dose, size, and contrast, and in guiding real CT scan dose reduction experiments. Such a model observer can be applied in optimizing parameters in advanced iterative reconstruction algorithms as well as guiding dose reduction protocols in physical CT experiments.

60 APPLIED LIFE SCIENCES↗

A directed search for extraterrestrial laser signals

The focus of NASA's Search for Extraterrestrial Intelligence (SETI) Program is on microwave frequencies, where receivers have the best sensitivities for the detection of narrowband signals. Such receivers, when coupled to existing radio telescopes, form an optimal system for broad area searches over the sky. For a directed search, however, such as toward specific stars, calculations show that infrared wavelengths can be equally as effective as radio wavelengths for establishing an interstellar communication link. This is true because infrared telescopes have higher directivities (gains) that effectively compensate for the lower sensitivities of infrared receivers. The result is that, for a given level of transmitted power, the signal to noise ratio for communications is equally as good at infrared and radio wavelengths. It should also be noted that the overall sensitivities of both receiver systems are quite close to their respective fundamental limits: background thermal noise for the radio frequency system and quantum noise for the infrared receiver. Consequently, the choice of an optimum communication frequency may well be determined more by the achievable power levels of transmitters rather than the ultimate sensitivities of receivers at any specific frequency. In the infrared, CO2 laser transmitters with power levels greater than 1 MW can already be built on Earth. For a slightly more advanced civilization, a similar but enormously more powerful laser may be possible using a planetary atmosphere rich in CO2. Because of these possibilities and our own ignorance of what is really the optimum search frequency, a search for narrowband signals at infrared frequencies should be a part of a balanced SETI Program. Detection of narrowband infrared signals is best done with a heterodyne receiver functionally identical to a microwave spectral line receiver. We have built such a receiver for the detection of CO2 laser radiation at wavelengths near 10 microns. The spectrometer uses a high-speed HgCdTe diode as the photomixer and a small CO2 laser as the local oscillator. Output signals in the intermediate frequency range 0.1-2.6 GHz are processed by a 1000-channel acousto-optic signal processor. The receiver is being used on a 1.5-m telescope on Mt. Wilson to survey a selected sample of 150 nearby stars. The current status of the work is discussed along with future project plans.

Betz, A.↗

Thin Film Sensors for Surface Measurements

Advanced thin film sensors that can provide accurate surface temperature, strain, and heat flux measurements have been developed at NASA Glenn Research Center. These sensors provide minimally intrusive characterization of advanced propulsion materials and components in hostile, high-temperature environments as well as validation of propulsion system design codes. The sensors are designed for applications on different material systems and engine components for testing in engine simulation facilities. Thin film thermocouples and strain gauges for the measurement of surface temperature and strain have been demonstrated on metals, ceramics and advanced ceramic-based composites of various component configurations. Test environments have included both air-breathing and space propulsion-based engine and burner rig environments at surface temperatures up to 1100 C and under high gas flow and pressure conditions. The technologies developed for these sensors as well as for a thin film heat flux gauge have been integrated into a single multifunctional gauge for the simultaneous real-time measurement of surface temperature, strain, and heat flux. This is the first step toward the development of smart sensors with integrated signal conditioning and high temperature electronics that would have the capability to provide feedback to the operating system in real-time. A description of the fabrication process for the thin film sensors and multifunctional gauge will be provided. In addition, the material systems on which the sensors have been demonstrated, the test facilities and the results of the tests to-date will be described. Finally, the results will be provided of the current effort to demonstrate the capabilities of the multifunctional gauge.

Martin, Lisa C.↗

Mechanical signaling and the cellular response to extracellular matrix in angiogenesis and cardiovascular physiology

Great advances have been made in the identification of the soluble angiogenic factors, insoluble extracellular matrix (ECM) molecules, and receptor signaling pathways that mediate control of angiogenesis--the growth of blood capillaries. This review focuses on work that explores how endothelial cells integrate these chemical signals with mechanical cues from their local tissue microenvironment so as to produce functional capillary networks that exhibit specialized form as well as function. These studies have revealed that ECM governs whether an endothelial cell will switch between growth, differentiation, motility, or apoptosis programs in response to a soluble stimulus based on its ability to mechanically resist cell tractional forces and thereby produce cell and cytoskeletal distortion. Transmembrane integrin receptors play a key role in this mechanochemical transduction process because they both organize a cytoskeletal signaling complex within the focal adhesion and preferentially focus mechanical forces on this site. Molecular filaments within the internal cytoskeleton--microfilaments, microtubules, and intermediate filaments--also contribute to the cell's structural and functional response to mechanical stress through their role as discrete support elements within a tensegrity-stabilized cytoskeletal array. Importantly, a similar form of mechanical control also has been shown to be involved in the regulation of contractility in vascular smooth muscle cells and cardiac myocytes. Thus, the mechanism by which cells perform mechanochemical transduction and the implications of these findings for morphogenetic control are discussed in the wider context of vascular development and cardiovascular physiology.

Non-NASA Center↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

Multimode-Guided-Wave Ultrasonic Scanning of Materials

Two documents discuss a method of characterizing advanced composite materials by use of multimode-guided ultrasonic waves. A transmitting transducer excites modulated (e.g., pulsed) ultrasonic waves at one location on a surface of a plate specimen. The waves interact with microstructure and flaws as they propagate through the specimen to a receiving transducer at a different location. The received signal is analyzed to determine the total (multimode) ultrasonic response of the specimen and utilize this response to evaluate microstructure and flaws. The analysis is performed by software that extracts parameters of signals in the time and frequency domains. Scanning is effected by using computer-controlled motorized translation stages to position the transducers at specified pairs of locations and repeating the measurement, data-acquisition, and data-analysis processes at the successive locations. One document presents results of a scan of a specimen containing a delamination.

Roth, Don↗

An Overview of Scientific and Space Weather Results from the Communication/Navigation Outage Forecasting System (C/NOFS) Mission

The Communication/Navigation Outage Forecasting System (C/NOFS) Mission of the Air Force Research Laboratory is described. C/NOFS science objectives may be organized into three categories: (1) to understand physical processes active in the background ionosphere and thermosphere in which plasma instabilities grow; (2) to identify mechanisms that trigger or quench the plasma irregularities responsible for signal degradation; and (3) to determine how the plasma irregularities affect the propagation of electromagnetic waves. The satellite was launched in April, 2008 into a low inclination (13 deg), elliptical (400 x 850 km) orbit. The satellite sensors measure the following parameters in situ: ambient and fluctuating electron densities, AC and DC electric and magnetic fields, ion drifts and large scale ion composition, ion and electron temperatures, and neutral winds. C/NOFS is also equipped with a GPS occultation receiver and a radio beacon. In addition to the satellite sensors, complementary ground-based measurements, theory, and advanced modeling techniques are also important parts of the mission. We report scientific and space weather highlights of the mission after nearly four years in orbit

Pfaff, R.↗