Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

FEM design and simulation of a short, 10 MV, S-band Linac with Monte Carlo dose simulations

Purpose: Current commercial 10 MV Linac waveguides are 1.5 m. The authors’ current 6 MV linear accelerator–magnetic resonance imager (Linac–MR) system fits in typical radiotherapy vaults. To allow 10 MV treatments with the Linac–MR and still fit within typical vaults, the authors design a 10 MV Linac with an accelerator waveguide of the same length (27.5 cm) as current 6 MV Linacs. Methods: The first design stage is to design a cavity such that a specific experimental measurement for breakdown is applicable to the cavity. This is accomplished through the use of finite element method (FEM) simulations to match published shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength from an electric breakdown study. A full waveguide is then designed and tuned in FEM simulations based on this cavity design. Electron trajectories are computed through the resulting radio frequency fields, and the waveguide geometry is modified by shifting the first coupling cavity in order to optimize the electron beam properties until the energy spread and mean energy closely match values published for an emulated 10 MV Linac. Finally, Monte Carlo dose simulations are used to compare the resulting photon beam depth dose profile and penumbra with that produced by the emulated 10 MV Linac. Results: The shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength are all matched to within 0.1%. A first coupling cavity shift of 1.45 mm produces an energy spectrum width of 0.347 MeV, very close to the published value for the emulated 10 MV of 0.315 MeV, and a mean energy of 10.53 MeV, nearly identical to the published 10.5 MeV for the emulated 10 MV Linac. The depth dose profile produced by their new Linac is within 1% of that produced by the emulated 10 MV spectrum for all depths greater than 1.5 cm. The penumbra produced is 11% narrower, as measured from 80% to 20% of the central axis dose. Conclusions: The authors have successfully designed and simulated an S-band waveguide of length of 27.5 cm capable of producing a 10 MV photon beam. This waveguide operates well within the breakdown threshold determined for the cavity geometry used. The designed Linac produces depth dose profiles similar to those of the emulated 10 MV Linac (waveguide-length of 1.5 m) but yields a narrower penumbra.

07 ISOTOPE AND RADIATION SOURCES↗

Pulsed laser generation of ultrasound in a metal plate between the melting and ablation thresholds

The generation of ultrasound in a metal plate exposed to nanosecond pulsed laser heating, sufficient to cause melting but not ablation, is treated. Consideration is given to the spatial and temporal profiles of the laser pulse, penetration of the laser beam into the sample, the evolution of the melt pool, and thermal conduction in the melt and surrounding solid. The excitation of the ultrasound takes place over a few nanoseconds, and occurs predominantly within the thermal diffusion length of a micron or so beneath the surface. Because of this, the output of the thermal simulations can be represented as axially symmetric transient radial and normal surface force distributions. The epicentral displacement response at the opposite surface to these forces is obtained by two methods, the one based on the elastodynamic Green’s functions for plate geometry determined by the Cagniard generalized ray method, and the other using a finite element numerical method. The two approaches are in very close agreement. Numerical simulations are reported of the epicentral displacement response of a 3.12mm thick tungsten plate irradiated with a 4 ns pulsed laser beam with Gaussian spatial profile, at intensities below and above the melt threshold. Comparison is made between results obtained using available temperature dependent thermophysical data, and room temperature materials constants except near the melting point.

36 MATERIALS SCIENCE↗

Optimization and active stabilization of a far-infrared laser for NSTX-U high poloidal wavenumber scattering diagnostics

The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.

Xu, Xinhang [Univ. of California, Davis, CA (Unite↗

Activation and residual dose rates in the NSLS-II storage ring

It is well known that components in high energy accelerators may get activated and expose workers during maintenance activities. While the potential for activation is higher in positive ion accelerators due to the prolific production of neutrons, certain regions and components in high energy electron accelerators too can be activated enough to create residual dose rates that require careful attention for ALARA compliance. In this report, the activation and residual dose rates from a few materials are studied from various beam loss scenarios ranging from chronic point losses to intermittent real loss scenarios obtained from the operational parameters of the NSLS-II storage ring. FLUKA Monte Carlo radiation transport code is used to model the geometry, the time profile of the beam losses and score the resulting time evolution of the remnant activity and the residual dose rates.

36 MATERIALS SCIENCE↗

Compact, Low-Cost, Light-Weight, Superconducting, Ironless Cyclotrons for Hadron Radiotherapy

Superconducting cyclotrons are increasingly employed for proton beam radiotherapy treatment (PBRT). The use of superconductivity in a cyclotron design can reduce its mass by an order of magnitude and size by a factor of 3-4 over conventional resistive magnet technology, yielding significant reduction in overall cost of the device, the accelerator vault, and its infrastructure, as well as reduced operating costs. At MIT, previous work was focused on developing a very high field (9 T at the pole face) superconducting synchrocyclotron that resulted in a highly compact device that is about an order of magnitude lighter, and much smaller in diameter than a conventional, resistive cyclotron. The results of the study reported here were focused on a conceptual design for a compact superconducting synchrocyclotron to demonstrate the possibility to further reduce its weight by almost another order of magnitude by eliminating all iron from the device. In the absence of magnetic iron poles, the magnetic field profile in the beam gap is achieved through a set of main superconducting split pair coils energized in series with a set of distributed field-shaping superconducting coils. External magnetic field shielding is achieved through a set of outer, superconducting ring coils, also connected in series with the other coils, to cancel the stray magnetic field. These shielding coils replace the heavy iron yoke which is the conventional method to return the magnetic flux. It is noted that the 10 Gauss surface is located at a radius of about 3.5 m comparable in both ironless and conventional devices, even in the absence of iron in the ironless device. An important result from eliminating all magnetic iron in the flux circuit is the resulting linear relationship between the operating current and the magnetic field intensity. In the case with iron, the saturation of the magnetic field forces operation at one value of magnetic field. This feature design then enables continuous beam energy variation without the use of an energy degrader, thus eliminating secondary radiation during the in-depth beam scanning, increasing the ion current delivered to the patient and improving the beam quality. The beam energy is determined by the magnetic field strength at the extraction radius, and changing the field enables selection of the final beam energy. The magnetic field can be adjusted while maintaining the needed radial field profile.

Minervini, Joseph V.↗

SU-E-T-360: End-To-End Dosimetric Testing of a Versa HD Linear Accelerator with the Agility Head Modeled in Pinnacle3

Purpose: The Versa HD incorporates a variety of upgrades, primarily including the Agility head. The distinct dosimetric properties of the head from its predecessors combined with flattening-filter-free (FFF) beams require a new investigation of modeling in planning systems and verification of modeling accuracy. Methods: A model was created in Pinnacle{sup 3} v9.8 with commissioned beam data. Leaf transmission was modeled as <0.5% with maximum leaf speed of 3 cm/s. Photon spectra were tuned for FFF beams, for which profiles were modeled with arbitrary profiles rather than with cones. For verification, a variety of plans with varied parameters were devised, and point dose measurements were compared to calculated values. A phantom of several plastic water and Styrofoam slabs was scanned and imported into Pinnacle{sup 3}. Beams of different field sizes, SSD, wedges, and gantry angles were created. All available photon energies (6 MV, 10 MV, 18 MV, 6 FFF, 10 FFF) as well four clinical electron energies (6, 9, 12, and 15 MeV) were investigated. The plans were verified at a calculation point (8 cm deep for photons, variable for electrons) by measurement with a PTW Semiflex ionization chamber. In addition, IMRT testing was performed with three standard plans (step and shoot IMRT, small and large field VMAT plans). The plans were delivered on the Delta4 IMRT QA phantom (ScandiDos, Uppsala, Sweden). Results: Homogeneous point dose measurement agreed within 2% for all photon and electron beams. Open field photon measurements along the central axis at 100 cm SSD passed within 1%. Gamma passing rates were >99.5% for all plans with a 3%/3mm tolerance criteria. The IMRT QA results for the first 23 patients yielded gamma passing rates of 97.4±2.3%. Conclusion: The end-to-end testing ensured confidence in the ability of Pinnacle{sup 3} to model photon and electron beams with the Agility head.

60 APPLIED LIFE SCIENCES↗

Concentric semi-circular split profiling for computed tomographic imaging of electronic beams

Apparatus and method for analyzing an electron beam including a circular sensor disk adapted to receive the electron beam, an inner semi-circular slit in the circular sensor disk; an outer semi-circular slit in the circular sensor disk wherein the outer semi-circular slit is spaced from the first semi-circular slit by a fixed distance; a system for sweeping the electron beam radially outward from the central axis to the inner semi-circular slit and outer second semi-circular slit; a sensor structure operatively connected to the circular sensor disk wherein the sensor structure receives the electron beam when it passes over the inner semi-circular slit and the outer semi-circular slit; and a device for measuring the electron beam that is intercepted by the inner semi-circular slit and the outer semi-circular slit.

42 ENGINEERING↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Deformation of a laser beam in the fabrication of graphite microstructures inside a volume of diamond

We report a theoretical and experimental study of the energy profile deformation along the laser beam axis during the fabrication of graphite microstructures inside a diamond crystal. The numerical simulation shows that the use of a focusing lens with a numerical aperture NA < 0.1 at a focusing depth of up to 2 mm makes it possible to avoid a noticeable change in the energy profile of the beam due to the spherical aberration that occurs in the case of refraction of the focused laser beam at the air – diamond interface. The calculation results are confirmed by experimental data on the distribution of the laser intensity along the beam axis in front of its focal plane, derived from observations of graphitisation wave propagation in diamond. The effect of radiation self-focusing on laser-induced graphitisation of diamond is analysed. It is shown that if the wavefront distortion due to self-focusing can be neglected at a minimum pulse energy required for the optical breakdown of diamond, then an increase in the beam distortion with increasing pulse energy has no effect on the graphitisation process. (interaction of laser radiation with matter)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION↗

Preliminary design of electrostatic sensors for MITICA beam line components

Megavolt ITER Injector and Concept Advancement, the full-scale prototype of ITER neutral beam injector, is under construction in Italy. The device will generate deuterium negative ions, then accelerated and neutralized. The emerging beam, after removal of residual ions, will be dumped onto a calorimeter. The presence of plasma and its parameters will be monitored in the components of the beam-line, by means of specific electrostatic probes. Double probes, with the possibility to be configured as Langmuir probes and provide local ion density and electron temperature measurements, will be employed in the neutralizer and in the residual ion dump. Biased electrodes collecting secondary emission electrons will be installed in the calorimeter with the aim to provide a horizontal profile of the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Radiation Environment Nuclear Fragment Separator Magnet

Superconducting coils wound with HTS conductor can be used in magnets located in a high radiation environment. NbTi and Nb 3 Sn superconductors must operate at 4.5 K or below where removal of heat is less efficient. The HTS conductor can carry significant current at higher temperatures where the Carnot efficiency is significantly more favorable and where the coolant heat capacity is much larger. Using the HTS conductor the magnet can be operated at 40 K. This project examines the use of HTS conductor for the Michigan State University Facility For Rare Isotope Beams (FRIB) fragment separator dipole magnet which bends the beam by 30° and is located in a high radiation region that will not be easily accessible. Two of these magnets are needed to select the chosen isotope. There are a number of technical challenges to be addressed in the design of this magnet. The separator dipole is 2 m long and subtends a large angle. The magnet should keep a constant transverse field profile along its beam reference path. Winding coils with a curved inner segment is difficult as the conductor will tend to unwind during the process. In the Phase I project two approaches to winding the conductor were examined. The first was to wind the coils with curved sections on the inner and outer segments with the inner segment wound with negative curvature. The alternate approach was to use a straight segment on the inner segment to avoid negative curvature. In Phase I coils with a limited number of turns were successfully wound and tested at 77 K for both coil configurations. The Phase II program concentrated on the design, coil winding procedures, structural analysis, prototyping and testing of an HTS curved dipole coil at 40 K with a heat load representative of the radiation environment. One of the key criteria of the design of this magnet is to avoid the use of organic materials that would degrade rapidly in radiation. The Lorentz forces expected from the coils interacting with the magnetic field are large and in order minimize the deformation of the coils, mechanical support must be provided. Since the support structure cannot be made of organic materials with minimal thermal conductivity, an optimization was explored comparing the amount of coil deformation that can be tolerated and the amount of heat leakage that can be endured. A test coil containing 500 m of HTS was constructed to be tested at the 40 K operating temperature. The anticipated heat load was simulated with heater strips to demonstrate that the heat could be removed and that the coil can operate in a stable state. The FRIB project has decided that using HTS coils for this magnet was too risky considering their time and funding constraints and has opted for a more conservative approach with conventional coils. As an outcome of this STTR project, it is likely that HTS coils operating at higher temperatures will have beneficial applications for future accelerator projects.

40 K↗

Orbit-averaging and deposition accuracy for runaway electron beams in hybrid kinetic-MHD simulations of the runaway plateau

We develop a new procedure that combines the kinetic orbit runaway electron code (KORC) and the NIMROD extended-magnetohydrodynamic code to simulate runaway electrons (REs) in the post-disruption plateau. KORC integrates guiding-center orbits, with a barycentric-based binary search strategy providing initial guesses for the Newton–Raphson logical-to-physical coordinate inversion, ensuring reliable particle-to-mesh mapping in NIMROD, whose fields remain static for the present study. Samples are drawn in accord with experimental parallel current profiles of RE beams during the plateau phase. Deposition in NIMROD is verified through comparison with a Python-based finite-element code that ensures periodicity in the poloidal direction and continuity at the magnetic axis. Accurate representation of near-axis fields requires finer mesh resolution to prevent under- and overshoots in current density from orbit inaccuracies. Yet, at a fixed particle count, increasing mesh resolution amplifies statistical noise in the deposited fields. An orbit-averaging method accumulates partial current deposits over multiple kinetic steps and reduces the statistical noise with little added computational cost. By coupling kinetic routines from KORC directly into the NIMROD codebase, these developments lay essential groundwork for future self-consistent KORC–NIMROD coupling.

Algorithms and data structure↗

Dynamic evolution of ultracold electron beams from nanostructured cathodes

Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.

43 PARTICLE ACCELERATORS↗

SU-F-T-460: Dosimetric Matching Between Trilogy Tx and TrueBeam STx

Purpose: To compare the commissioned beam data for one flattening filter photon mode (6 MV) and two flattening filter-free (FFF) photon modes (6 and 10 MV-FFF) between Trilogy Tx and TrueBeam STx and evaluate the possibility of dosimetric matching Methods: Dosimetric characteristics of the new Trilogy Tx including percent depth doses (PDDs), profiles, and output factors were measured for commissioning. Linear diode array detector and ion chambers were used to measure dosimetric data. The depth of dose maximum (dmax) and PDD at 10 cm (PDD10) were evaluated: 3×3 cm{sup 2}, 10×10 cm{sup 2}, and 40×40 cm{sup 2}. The beam profiles were compared and then penumbras were evaluated. As a further test of the dosimetric matching, the same VMAT plans were delivered, measured with film, and compared with TPS calculation. Results: All the measured PDDs matched well across the two units. PDD10 showed less than 0.5% variation and dmax were within 1.5 mm at the field sizes evaluated. Within the central 80% of transverse axis, profile data were almost identical. TrueBeam data resulted in a slightly greater penumbra width (up to 1.9 mm). The greatest differences of output factors were found at 40 × 40 cm{sup 2}: 2.40%, 2.03%, and 2.22% for 6 MV, 6 MV-FFF, and 10 MV-FFF, respectively. For smaller field sizes, less than 1% differences were observed. The film measurements demonstrated over 97.3% pixels passing-gamma analysis (2%/2mm). The results showed excellent agreement between measurements of two machines. Conclusion: The differences between Trilogy Tx and TrueBeam STx found could possibly affect small field and also very large field sizes in dosimetric matching considerations. These differences encountered are mostly related with the changes in the head design of the TrueBeam. Although it cannot guarantee full interchangeability of two machines, dosimetric matching by field size of 25 × 25 cm{sup 2} might be clinically acceptable.

07 ISOTOPE AND RADIATION SOURCES↗

Spatial profile of argon (1s 5 ) metastables in an electron beam generated plasma

Electron beams with an applied magnetic field generate a secondary cold plasma with a selective chemical composition, featuring low-energy ions and metastable species in the discharge periphery, ideal for low-damage plasma treatment of material substrates. In this work, we studied the plasma generated by an e-beam using a 4 kV voltage in a pure argon gas environment under a magnetic field of 150 G and in the pressure range of 25–90 mTorr. We measured the absolute spatial density profile of argon (1 s 5 ) metastables in an electron beam generated plasma by laser-induced fluorescence and found it to be of the order of 10 16 m −3 . The electron temperature and the electron density measured by a Langmuir probe were of the order of 10 16 m −3 and less than an eV respectively. Electron-impact quenching was identified as a significant loss mechanism for the Ar(1s 5 ) state, leading to the saturation of the metastable density at higher pressures. Outside the primary ionization region, the spatial distribution of argon metastables followed a linear diffusion profile, indicating negligible additional production in those regions.

EEDF↗

SU-F-T-261: Reconstruction of Initial Photon Fluence Based On EPID Images

Purpose: Verifying an algorithm to reconstruct relative initial photon fluence for clinical use. Clinical EPID and CT images were acquired to reconstruct an external photon radiation treatment field. The reconstructed initial photon fluence could be used to verify the treatment or calculate the applied dose to the patient. Methods: The acquired EPID images were corrected for scatter caused by the patient and the EPID with an iterative reconstruction algorithm. The transmitted photon fluence behind the patient was calculated subsequently. Based on the transmitted fluence the initial photon fluence was calculated using a back-projection algorithm which takes the patient geometry and its energy dependent linear attenuation into account. This attenuation was gained from the acquired cone-beam CT or the planning CT by calculating a water-equivalent radiological thickness for each irradiation direction. To verify the algorithm an inhomogeneous phantom consisting of three inhomogeneities was irradiated by a static 6 MV photon field and compared to a reference flood field image. Results: The mean deviation between the reconstructed relative photon fluence for the inhomogeneous phantom and the flood field EPID image was 3% rising up to 7% for off-axis fluence. This was probably caused by the used clinical EPID calibration, which flattens the inhomogeneous fluence profile of the beam. Conclusion: In this clinical experiment the algorithm achieved good results in the center of the field while it showed high deviation of the lateral fluence. This could be reduced by optimizing the EPID calibration, considering the off-axis differential energy response. In further progress this and other aspects of the EPID, eg. field size dependency, CT and dose calibration have to be studied to realize a clinical acceptable accuracy of 2%.

60 APPLIED LIFE SCIENCES↗