At least 667 records · Page 37

Development of a pepper-pot device to determine the emittance of an ion beam generated by electron cyclotron resonance ion sources

This paper describes the recent development and commissioning of a pepper-pot emittance meter at the Lawrence Berkeley National Laboratory (LBNL). It is based on a potassium bromide (KBr) scintillator screen in combination with a charged coupled device camera. Pepper-pot scanners record the full four-dimensional transverse phase space emittances which are particularly interesting for electron cyclotron resonance ion sources. The strengths and limitations of evaluating emittances using optical pepper-pot scanners are described and systematic errors induced by the optical data acquisition system will be presented. Light yield tests of KBr exposed to different ion species and first emittance measurement data using ion beams extracted from the 6.4 GHz LBNL electron cyclotron resonance ion source are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma ignition and steady state simulations of the Linac4 H{sup −} ion source

The RF heating of the plasma in the Linac4 H{sup −} ion source has been simulated using a particle-in-cell Monte Carlo collision method. This model is applied to investigate the plasma formation starting from an initial low electron density of 10{sup 12} m{sup −3} and its stabilization at 10{sup 18} m{sup −3}. The plasma discharge at low electron density is driven by the capacitive coupling with the electric field generated by the antenna, and as the electron density increases the capacitive electric field is shielded by the plasma and induction drives the plasma heating process. Plasma properties such as e{sup −}/ion densities and energies, sheath formation, and shielding effect are presented and provide insight to the plasma properties of the hydrogen plasma.

43 PARTICLE ACCELERATORS↗

Next Generation H{sup -} Ion Sources for the SNS

The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H- ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H- ion source based on an A1N ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA(60 Hz, 1 ms) have been observed and sustained currents >60 mA(60 Hz, 1 ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H- beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

43 PARTICLE ACCELERATORS↗

Development of spectrally selective imaging system for negative hydrogen ion source

A spectrally selective imaging system has been developed to obtain a distribution of H{sub α} emissions at the extraction region in a hydrogen negative ion source. The diagnostic system consisted of an aspherical lens, optical filters, a fiber image conduit, and a charge coupled device detector was installed on the 1/3-scaled hydrogen negative ion source in the National Institute for Fusion Science. The center of sight line passes beside the plasma grid (PG) surface with the distance of 11 mm, and the viewing angle has coverage 35 mm from the PG surface. Two dimensional H{sub α} distribution in the range up to 20 mm from the PG surface was clearly observed. The reduction area for H{sub α} emission caused by beam extraction was widely distributed in the extraction region near the PG surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEVELOPMENT OF THE SNS EXTERNAL ANTENNA H- ION SOURCE

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility currently in the process of ramping up neutron production. To meet present and future beam current and reliability requirements we are developing an RF-driven, H- ion source based on a ceramic aluminium nitride (AlN) plasma chamber surrounded by an external RF antenna. This report recounts the design of the prototype source, describes the Cs collar variations tested, enumerates recent modifications made to the source to prepare a production version, and summarizes the results of runs on the SNS test stand and Front End (FE) of the SNS accelerator. Up to ~100 mA unanalyzed beam currents (60Hz, 1ms) have been measured on the SNS ion source test stand, and up to 42mA have been successfully accelerated by the RFQ on the SNS front-end at lower RF power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Next Generation H- Ion Sources for the SNS

The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H{sup -} ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H{sup -} ion source based on an AlN ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA (60Hz, 1ms) have been observed and sustained currents >60 mA (60Hz, 1ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H{sup -} beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

33 ADVANCED PROPULSION SYSTEMS↗

Atmospheric-pressure solution-cathode glow discharge: A versatile ion source for atomic and molecular mass spectrometry

We report an atmospheric-pressure solution-cathode glow discharge (SCGD) has been evaluated as an ion source for atomic, molecular, and ambient desorption/ionization mass spectrometry. The SCGD consists of a direct-current plasma, supported in the ambient air in the absence of gas flows, and sustained upon the surface of a flowing liquid cathode. Analytes introduced in the flowing liquid, as an ambient gas, or as a solid held near the plasma are vaporized and ionized by interactions within or near the discharge. Introduction of acidic solutions containing metal salts produced bare elemental ions as well as H 2 O, OH - and NO 3 - adducts. Detection limits for these elemental species ranged from 0.1 to 4 ppb, working curves spanned more than 4 orders of linear dynamic range, and precision varied between 5 and 16% relative standard deviation. Small organic molecules were also efficiently ionized from solution, and both the intact molecular ion and fragments were observed in the resulting SCGD mass spectra. Fragmentation of molecular species was found to be tunable; high discharge currents led to harder ionization, while low discharge currents produced stronger molecular-ion signals. Ambient gases and solids, desorbed by the plasma from a glass probe, were also readily ionized by the SCGD. Indeed, strong analyte signals were obtained from solid samples placed at least 2 cm from the plasma. These findings indicate that the SCGD might be useful also for ambient desorption/ionization mass spectrometry. In conclusion, combined with earlier results that showed the SCGD is useful for ionization of labile biomolecules, the results here indicate that the SCGD is a highly versatile ion source capable of providing both elemental and molecular mass-spectral information.

74 ATOMIC AND MOLECULAR PHYSICS↗

Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

We investigated the ion-loss distribution on the sidewall of an electron cyclotron resonance (ECR) plasma chamber using the 18-GHz ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex (TRIAC). Similarities and differences between the ion-loss distributions (longitudinal and azimuthal) of different ion species (i.e., radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions that are typical volatile and nonvolatile elements) was qualitatively discussed to understand the element dependence of the charge breeding efficiency. Especially, the similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

43 PARTICLE ACCELERATORS↗

Ion source development for a photoneutralization based NBI system for fusion reactors

The next step after ITER is to demonstrate the viability and generation of electricity by a future fusion reactor (DEMO). The specifications required to operate an NBI system on DEMO are very demanding. The system has to provide a very high level of power and energy, ~100MW of D° beam at 1MeV, including high wall-plug efficiency (η > 60%). For this purpose, a new injector concept, called Siphore, is under investigation between CEA and French universities. Siphore is based on the stripping of the accelerated negative ions by photo-detachment provided by several Fabry-Perot cavities (3.5MW of light power per cavity) implemented along the D{sup −} beam. The beamline is designed to be tall and narrow in order that the photon flux overlaps the entire negative ion beam. The paper will describe the present R and D at CEA which addresses the development of an ion source and pre-accelerator prototypes for Siphore, the main goal being to produce an intense negative ion beam sheet. The negative ion source Cybele is based on a magnetized plasma column where hot electrons are emitted from the source center. Parametric studies of the source are performed using Langmuir probes in order to characterize the plasma and to compare with numerical models being developed in French universities.

43 PARTICLE ACCELERATORS↗

The SNS External Antenna H- Ion Source

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure that we will meet our operational commitments as well as provide for future facility upgrades with high reliability, we have developed an RF-driven, H- ion source based on a ceramic aluminum nitride (AlN) plasma chamber [1]. This source is expected to be utilized by the SNS for neutron production starting in 2009. This report details the design of the production source which features an AlN plasma chamber, 2-layer external antenna, cooled-multicusp magnet array, Cs2CrO4 cesium system and a Molybdenum plasma ignition gun. Performance of the production source both on the SNS accelerator and SNS test stand is reported. The source has also been designed to accommodate an elemental Cs system with an external reservoir which has demonstrated unanalyzed beam currents up to ~100mA (60Hz, 1ms) on the SNS ion source test stand.

43 PARTICLE ACCELERATORS↗

Note: A pulsed laser ion source for linear induction accelerators

We have developed a high-current laser ion source for induction accelerators. A copper target was irradiated by a frequency-quadrupled Nd:YAG laser (266 nm) with relatively low intensities of 10{sup 8} W/cm{sup 2}. The laser-produced plasma supplied a large number of Cu{sup +} ions (∼10{sup 12} ions/pulse) during several microseconds. Emission spectra of the plasma were observed and the calculated electron temperature was about 1 eV. An induction voltage adder extracted high-current ion beams over 0.5 A/cm{sup 2} from a plasma-prefilled gap. The normalized beam emittance measured by a pepper-pot method was smaller than 1 π mm mrad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of radial and axial high energy x-ray spectra in electron cyclotron resonance ion source plasmas

Radial and axial x-ray measurements of electron cyclotron resonance ion sources operating at microwave frequencies of 6.4 and 14 GHz are presented. Results indicate a greater detected photon energy in the radial direction than the axial direction for both the 6.4 GHz source and the 14 GHz source. It is also seen that the 14 GHz source produces x-rays with higher energies, when compared to the 6.4 GHz source, in both radial and axial directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deterministic Ultracold Ion Source Targeting the Heisenberg Limit

The major challenges to fabricate quantum processors and future nano-solid-state devices are material modification techniques with nanometer resolution and suppression of statistical fluctuations of dopants or qubit carriers. Based on a segmented ion trap with mK laser-cooled ions we have realized a deterministic single-ion source which could operate with a huge range of sympathetically cooled ion species, isotopes or ionic molecules. We have deterministically extracted a predetermined number of ions on demand and have measured a longitudinal velocity uncertainty of 6.3 m/s and a spatial beam divergence of 600 {mu}rad. We show in numerical simulations that if the ions are cooled to the motional ground state (Heisenberg limit) nanometer spatial resolution can be achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MeV negative ion source from ultra-intense laser-matter interaction

Experimental demonstration of negative ion acceleration to MeV energies from sub-micron size droplets of water spray irradiated by ultra-intense laser pulses is presented. Thanks to the specific target configuration and laser parameters, more than 10{sup 9} negative ions per steradian solid angle in 5% energy bandwidth are accelerated in a stable and reliable manner. To our knowledge, by virtue of the ultra-short duration of the emission, this is by far the brightest negative ion source reported. The data also indicate the existence of beams of neutrals with at least similar numbers and energies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-energy dc ion source for low operating pressure

We report on an experimental study of an ion source based on a Penning discharge with a cold hollow cathode in crossed electric and magnetic fields. The minimum vacuum chamber operating pressure was 3 × 10{sup −5} Torr for argon and 5 × 10{sup −5} Torr for hydrogen. The use of a hollow cathode allowed decreasing the discharge operating voltage down to 350 V at a discharge current of ∼100 mA. At a discharge current of 100 mA and beam accelerating voltage of 2 kV, the ion current was 2.5 mA for argon and 8 mA for hydrogen, and the ion beam on-axis current density 170 and 450 μA/cm{sup 2}, respectively. The current-voltage characteristics of the discharge and the radial ion beam current density distribution were measured. The influence of pressure on the discharge parameters and their time stability was investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A revisit to self-excited push pull vacuum tube radio frequency oscillator for ion sources and power measurements

Self-excited push-pull vacuum tube oscillator is one of the most commonly used oscillators in radio frequency (RF)-ion plasma sources for generation of ions using radio frequency. However, in spite of its fundamental role in the process of plasma formation, the working and operational characteristics are the most frequently skip part in the descriptions of RF ion sources in literatures. A more detailed treatment is given in the present work on the RF oscillator alone using twin beam power tetrodes 829B and GI30. The circuit operates at 102 MHz, and the oscillation conditions, stability in frequency, and RF output power are studied and analyzed. A modified form of photometric method and RF peak voltage detection method are employed to study the variation of the oscillator output power with plate voltage. The power curves obtained from these measurements are quadratic in nature and increase with increase in plate voltage. However, the RF output power as measured by photometric methods is always less than the value calculated from peak voltage measurements. This difference is due to the fact that the filament coil of the ordinary light bulb used as load/detector in photometric method is not a perfect inductor. The effect of inductive reactance on power transfer to load was further investigated and a technique is developed to estimate the amount of power correction needed in the photometric measurement result.