Search NASA⌕ Search

SEARCH · Search NASA

Results for “Regularization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

First moments of nucleon generalized parton distributions

We extrapolate the first moments of the generalized parton distributions using heavy baryon chiral perturbation theory. The calculation is based on the one loop level with the finite range regularization. The description of the lattice data is satisfactory, and the extrapolated moments at physical pion mass are consistent with the results obtained with dimensional regularization, although the extrapolation in the momentum transfer to t=0 does show sensitivity to form factor effects, which lie outside the realm of chiral perturbation theory. We discuss the significance of the results in the light of modern experiments as well as QCD inspired models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On infrared and ultraviolet divergences of cosmological perturbations

We study a consistent infrared and ultraviolet regularization scheme for the cosmological perturbations. The infrared divergences are cured by assuming that the Universe undergoes a transition between a nonsingular preinflationary, radiation-dominated phase and a slow-roll inflationary evolution. The ultraviolet divergences are eliminated via adiabatic subtraction. A consistent regularization of the field fluctuations through this transition is obtained by performing a mode matching for both the gauge invariant Mukhanov variable and its adiabatic expansion. We show that these quantities do not generate ultraviolet divergences other than the standard ones, when evolving through the matching time. We also show how the DeWitt-Schwinger expansion, which can be used to construct the counter-terms regularizing the ultraviolet divergences, ceases to be valid well before horizon exit of the scales of interest. Thus, such counter-terms should not be used beyond the time of the horizon exit and it is unlikely that the observed power spectrum is modified by adiabatic subtraction, as claimed in some literature. On the contrary, the infrared regularization might have an impact on the observed spectrum, and we briefly discuss this possibility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synchrotron study of metal localization in Typha latifolia L. root sections

Understanding mechanisms that control plant root metal assimilation in soil is critical to the sustainable management of metal-contaminated land. With the assistance of the synchrotron X-ray fluorescence technique, this study investigated possible mechanisms that control the localization of Fe, Cu, Mn, Pb and Zn in the root tissues of Typha latifolia L. collected from a contaminated wetland. Metal localizations especially in the case of Fe and Pb in the dermal tissue and the vascular bundles were different. Cluster analysis was performed to divide the dermal tissue into iron-plaque-enriched dermal tissue and regular dermal tissue based on the spatial distribution of Pb and Fe. Factor analysis showed that Cu and Zn were closely correlated to each other in the dermal tissues. The association of Cu, Zn and Mn with Fe was strong in both regular dermal tissue and iron-plaque-enriched dermal tissue, while significant ( p < 0.05) correlation of Fe with Pb was only observed in tissues enriched with iron plaque. In the vascular bundles, Zn, Mn and Cu showed strong association, suggesting that the localization of these three elements was controlled by a similar mechanism. Iron plaque in the peripheral dermal tissues acted as a barrier for Pb and a buffer for Zn, Cu and Mn. The Casparian strip regulated the transportation of metals from dermal tissues to the vascular bundles. The results suggested that the mechanisms controlling metal localization in root tissues varied with both tissue types and metals.

Qian, Yu↗

An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach

Purpose: X-ray based tomographic blood perfusion imaging requires recovery of contrast time-attenuation-curves from dynamic projection data. When using slowly rotating imaging systems, this task is challenging due to nonsimultaneous projection acquisition. A dynamic reconstruction method is proposed that aims at compensating the lack of simultaneously acquired information by incorporating prior knowledge about the expected temporal contrast dynamics. Methods: A decomposition model using temporal basis functions to approximate time-attenuation-curves is integrated into an iterative tomographic reconstruction method. The computationally efficient implementation of the proposed approach makes use of standard forward-projections and backprojections, as well as scalar products in image space. The critical issue of projection noise propagation is tackled by the application of regularization which is realized by the early stopping of iteration cycles and by the proper selection of smooth temporal basis functions. The performance of the proposed dynamic reconstruction approach is evaluated in a simulation study concerning various aspects: Noise propagation and regularization, specification of the temporal model, and type of acquisition mode. Results: The evaluation based on dynamic phantom data indicates that tomographic recovery of contrast time-attenuation-curves in tissue can be achieved with an average range of accuracy of {approx}2% (with respect to dynamic peak attenuation) under ideal noise-free conditions. The relative estimation error for arterial time-attenuation-curves is in the range of 8%, which is due to faster contrast dynamics in the artery. In general, performance depends on the level of acquired information contained in the projection data, which is mainly influenced by the type of rotational acquisition mode; restrictions in angular range and speed can lead to limited accuracy. The analysis of propagated projection noise in a statistical bias-variance framework reveals relative noise levels in estimated time-attenuation-curves of 3%-4% in tissue regions and below 1% in vessels when using optimized settings for regularization. Here, the effect of noise suppression depends on the interrelation between the number of iteration cycles and the constraints imposed by the temporal decomposition model. Conclusions: For usage with slowly rotating imaging systems, the presented model-based iterative dynamic reconstruction method is capable of recovering contrast time-attenuation-curves related to tissue perfusion. The proposed regularization framework is an effective means to limit the impact of projection noise, which is a factor dominating estimation accuracy in tissue regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the interplay effects with proton scanning beams in stage III lung cancer

Purpose: To assess the dosimetric impact of interplay between spot-scanning proton beam and respiratory motion in intensity-modulated proton therapy (IMPT) for stage III lung cancer. Methods: Eleven patients were sampled from 112 patients with stage III nonsmall cell lung cancer to well represent the distribution of 112 patients in terms of target size and motion. Clinical target volumes (CTVs) and planning target volumes (PTVs) were defined according to the authors' clinical protocol. Uniform and realistic breathing patterns were considered along with regular- and hypofractionation scenarios. The dose contributed by a spot was fully calculated on the computed tomography (CT) images corresponding to the respiratory phase that the spot is delivered, and then accumulated to the reference phase of the 4DCT to generate the dynamic dose that provides an estimation of what might be delivered under the influence of interplay effect. The dynamic dose distributions at different numbers of fractions were compared with the corresponding 4D composite dose which is the equally weighted average of the doses, respectively, computed on respiratory phases of a 4DCT image set. Results: Under regular fractionation, the average and maximum differences in CTV coverage between the 4D composite and dynamic doses after delivery of all 35 fractions were no more than 0.2% and 0.9%, respectively. The maximum differences between the two dose distributions for the maximum dose to the spinal cord, heart V40, esophagus V55, and lung V20 were 1.2 Gy, 0.1%, 0.8%, and 0.4%, respectively. Although relatively large differences in single fraction, correlated with small CTVs relative to motions, were observed, the authors' biological response calculations suggested that this interfractional dose variation may have limited biological impact. Assuming a hypofractionation scenario, the differences between the 4D composite and dynamic doses were well confined even for single fraction. Conclusions: Despite the presence of interplay effect, the delivered dose may be reliably estimated using the 4D composite dose. In general the interplay effect may not be a primary concern with IMPT for lung cancers for the authors' institution. The described interplay analysis tool may be used to provide additional confidence in treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iterative image-domain decomposition for dual-energy CT

Purpose: Dual energy CT (DECT) imaging plays an important role in advanced imaging applications due to its capability of material decomposition. Direct decomposition via matrix inversion suffers from significant degradation of image signal-to-noise ratios, which reduces clinical values of DECT. Existing denoising algorithms achieve suboptimal performance since they suppress image noise either before or after the decomposition and do not fully explore the noise statistical properties of the decomposition process. In this work, the authors propose an iterative image-domain decomposition method for noise suppression in DECT, using the full variance-covariance matrix of the decomposed images. Methods: The proposed algorithm is formulated in the form of least-square estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, the authors include the inverse of the estimated variance-covariance matrix of the decomposed images as the penalty weight in the least-square term. The regularization term enforces the image smoothness by calculating the square sum of neighboring pixel value differences. To retain the boundary sharpness of the decomposed images, the authors detect the edges in the CT images before decomposition. These edge pixels have small weights in the calculation of the regularization term. Distinct from the existing denoising algorithms applied on the images before or after decomposition, the method has an iterative process for noise suppression, with decomposition performed in each iteration. The authors implement the proposed algorithm using a standard conjugate gradient algorithm. The method performance is evaluated using an evaluation phantom (Catphan©600) and an anthropomorphic head phantom. The results are compared with those generated using direct matrix inversion with no noise suppression, a denoising method applied on the decomposed images, and an existing algorithm with similar formulation as the proposed method but with an edge-preserving regularization term. Results: On the Catphan phantom, the method maintains the same spatial resolution on the decomposed images as that of the CT images before decomposition (8 pairs/cm) while significantly reducing their noise standard deviation. Compared to that obtained by the direct matrix inversion, the noise standard deviation in the images decomposed by the proposed algorithm is reduced by over 98%. Without considering the noise correlation properties in the formulation, the denoising scheme degrades the spatial resolution to 6 pairs/cm for the same level of noise suppression. Compared to the edge-preserving algorithm, the method achieves better low-contrast detectability. A quantitative study is performed on the contrast-rod slice of Catphan phantom. The proposed method achieves lower electron density measurement error as compared to that by the direct matrix inversion, and significantly reduces the error variation by over 97%. On the head phantom, the method reduces the noise standard deviation of decomposed images by over 97% without blurring the sinus structures. Conclusions: The authors propose an iterative image-domain decomposition method for DECT. The method combines noise suppression and material decomposition into an iterative process and achieves both goals simultaneously. By exploring the full variance-covariance properties of the decomposed images and utilizing the edge predetection, the proposed algorithm shows superior performance on noise suppression with high image spatial resolution and low-contrast detectability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-12A-06: A Comprehensive Parameter Analysis for Low Dose Cone-Beam CT Reconstruction

Purpose: There is always a parameter in compressive sensing based iterative reconstruction (IR) methods low dose cone-beam CT (CBCT), which controls the weight of regularization relative to data fidelity. A clear understanding of the relationship between image quality and parameter values is important. The purpose of this study is to investigate this subject based on experimental data and a representative advanced IR algorithm using Tight-frame (TF) regularization. Methods: Three data sets of a Catphan phantom acquired at low, regular and high dose levels are used. For each tests, 90 projections covering a 200-degree scan range are used for reconstruction. Three different regions-of-interest (ROIs) of different contrasts are used to calculate contrast-to-noise ratios (CNR) for contrast evaluation. A single point structure is used to measure modulation transfer function (MTF) for spatial-resolution evaluation. Finally, we analyze CNRs and MTFs to study the relationship between image quality and parameter selections. Results: It was found that: 1) there is no universal optimal parameter. The optimal parameter value depends on specific task and dose level. 2) There is a clear trade-off between CNR and resolution. The parameter for the best CNR is always smaller than that for the best resolution. 3) Optimal parameters are also dose-specific. Data acquired under a high dose protocol require less regularization, yielding smaller optimal parameter values. 4) Comparing with conventional FDK images, TF-based CBCT images are better under a certain optimally selected parameters. The advantages are more obvious for low dose data. Conclusion: We have investigated the relationship between image quality and parameter values in the TF-based IR algorithm. Preliminary results indicate optimal parameters are specific to both the task types and dose levels, providing guidance for selecting parameters in advanced IR algorithms. This work is supported in part by NIH (1R01CA154747-01)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. Results: HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. Conclusions: For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP4-15: The Roucoulette: A Set of Quality Control Tests for Dynamic Trajectory (4Pi) Treatment Delivery Techniques

Purpose: To present and validate a set of quality control tests for trajectory treatment delivery using synchronized dynamic couch (translation and rotation), MLC and collimator motion. Methods: The quality control tests are based on the Picket fence test, which consist of 5 narrow band 2mm width spaced at 2.5cm intervals, and adds progressively synchronized dynamic motions. The tests were exposed on GafChromic EBT3 films. The first test is a regular (no motion and MLC static while beam is on) Picket Fence test used as baseline. The second test includes simultaneous collimator and couch rotation, each stripe corresponding to a different rotation speed. Errors in these tests were introduced (0.5 degree and 1 degree error in rotation synchronization) to assess the error sensitivity of this test. The second test is similar to the regular Picket Fence but now including dynamic MLC motion and couch translation (including acceleration during delivery) while the beam is on. Finally in the third test, which is a combination of the first and second test, the Picket Fence pattern is delivered using synchronized collimator and couch rotation and synchronized dynamic MLC and couch translation including acceleration. Films were analyzed with FilmQA Pro. Results: The distance between the peaks in the dose profile where measured (18.5cm away from the isocentre in the inplane direction where non synchronized rotation would have the largest effect) and compared to the regular Picket Fence tests. For well synchronized motions distances between peaks where between 24.9–25.4 mm identical to the regular Picket Fence test. This range increased to 24.4–26.4mm and 23.4–26.4mm for 0.5 degree and 1 degree error respectively. The amplitude also decreased up to 15% when errors are introduced. Conclusion: We demonstrated that the Roucoulette tests can be used as a quality control tests for trajectory treatment delivery using synchronized dynamic motion.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-07: Filtered Iterative Reconstruction (FIR) Via Proximal Forward-Backward Splitting: A Synergy of Analytical and Iterative Reconstruction Method for CT

Purpose: This work is to develop a general framework, namely filtered iterative reconstruction (FIR) method, to incorporate analytical reconstruction (AR) method into iterative reconstruction (IR) method, for enhanced CT image quality. Methods: FIR is formulated as a combination of filtered data fidelity and sparsity regularization, and then solved by proximal forward-backward splitting (PFBS) algorithm. As a result, the image reconstruction decouples data fidelity and image regularization with a two-step iterative scheme, during which an AR-projection step updates the filtered data fidelity term, while a denoising solver updates the sparsity regularization term. During the AR-projection step, the image is projected to the data domain to form the data residual, and then reconstructed by certain AR to a residual image which is in turn weighted together with previous image iterate to form next image iterate. Since the eigenvalues of AR-projection operator are close to the unity, PFBS based FIR has a fast convergence. Results: The proposed FIR method is validated in the setting of circular cone-beam CT with AR being FDK and total-variation sparsity regularization, and has improved image quality from both AR and IR. For example, AIR has improved visual assessment and quantitative measurement in terms of both contrast and resolution, and reduced axial and half-fan artifacts. Conclusion: FIR is proposed to incorporate AR into IR, with an efficient image reconstruction algorithm based on PFBS. The CBCT results suggest that FIR synergizes AR and IR with improved image quality and reduced axial and half-fan artifacts. The authors was partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

60 APPLIED LIFE SCIENCES↗

TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments and treatment time. Varian Medical Systems; NIH grant R01CA188300; NIH grant R43CA183390.

60 APPLIED LIFE SCIENCES↗

Smooth full field reconstruction of velocity and its gradients from noisy scattered velocimetry data in a cross-slot flow

We present a method combining generalized Tikhonov regularization with a finite element approximation for reconstructing smooth velocity and velocity gradient fields from spatially scattered and noisy velocity data in a two-dimensional complex flow domain. Synthetic velocity data for a cross-slot geometry are generated using the Oldroyd-B solution, subsequently perturbed by random noise. Performances of diverse finite element continuity-regularization criterion combinations are tested against noise-free data, while the optimum regularization parameter is determined using generalized cross-validation. The best performance is achieved for the velocity field and its gradients simultaneously by C{sup 2} continuous Hermite finite elements and minimization of a norm of the velocity's third derivative. The standard regularization criterion based on the second derivative is shown to lead to systematic distortions in boundary regions, allowing therefore a lower reduction in the statistical error. Furthermore, optical fields are calculated by applying a differential constitutive equation directly to the reconstructed flow kinematics; high quality velocity gradient fields are shown to be an essential prerequisite for their reliable prediction. Overall, the method is expedient to implement and does not require boundary conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using Mobile Agents and Overlay Networks to Secure Electrical Netoworks

ABSTRACT The use of wandering, mobile agents can provide a robust approach for managing, monitoring, and securing electrical distribution networks. However, the topological structure of electrical networks can affect system performance. For example, if the multi-agent system relies on a regular inspection rate (on average, points of interest are inspected with equal frequency), then locations that are not well connected will on average be inspected less frequently. This paper discusses creation and use of overlay networks that create a virtual grid graph can provide faster coverage and a more uniform average agent sampling rate. Using overlays agents wander a virtual neighborhood consisting of only points of interest that are interconnected in a regular fashion (each point has the same number of neighbors). Experimental results will show that an overlay can often provide better network coverage and a more uniform inspection rate, which can improve cyber security by providing a faster detection of threats

Dawes, Neal A.↗

Diving into Petascale Production File Systems through Large Scale Profiling and Analysis

As leadership computing facilities grow their storage capacity into the multi- petabyte range, the number of files and directories leap into the scale of billions. A complete profiling of such a parallel file system in a production environment presents a unique challenge. On one hand, the time, resources, and negative performance impact on production users can make regular profiling difficult. On the other hand, the result of such profiling can yield much needed understanding of the file system's general characteristics, as well as provide insight to how users write and access their data on a grand scale. This paper presents a lightweight and scalable profiling solution that can efficiently walk, analyze, and profile multi-petabyte parallel file systems. This tool has been deployed and is in regular use on very large-scale production parallel file systems at both Oak Ridge National Lab's Oak Ridge Leadership Facility (OLCF) and Lawrence Livermore National Lab's Livermore Computing (LC) facilities. We present the results of our initial analysis on the data collected from these two large-scale production systems, organized into three use cases: (1) file system snapshot and composition, (2) striping pattern analysis for Lustre, and (3) simulated storage capacity utilization in preparation for future file systems. Our analysis shows that on the OLCF file system, over 96% of user files exhibit the default stripe width, potentially limiting performance on large files by underutilizing storage servers and disks. Our simulated block analysis quantitatively shows the space overhead when doing a forklift system migration. It also reveals that due to the difference in system compositions (OLCF vs. LC), we can achieve better performance and space trade-offs by employing different native file system block sizes.

Wang, Feiyi↗

Evaluation of known-boundary and resistivity constraints for improving cross-borehole DC electrical resistivity imaging of discrete fractures

There is a need to better characterize discrete fractures in contaminated hard rock aquifers to determine the fate of remediation injections away from boreholes and also to evaluate hydraulic fracturing performance. A synthetic cross borehole electrical resistivity study was conducted assuming a discrete fracture model of an existing contaminated site with known fracture locations. Four boreholes and two discrete fracture zones, assumed to be the dominant electrical and hydraulically conductive pathways, were explicitly modeled within an unstructured tetrahedral mesh. We first evaluated different regularization constraints starting with an uninformed smoothness-constrained inversion, to which a priori information was incrementally added. We found major improvements when (1) smoothness regularization constraints were relaxed (or disconnected) along boreholes and fractures, (2) a homogeneous conductivity was assumed along boreholes, and (3) borehole conductivity constraints that could be determined from a specific conductance log were applied. We also evaluated the effect of including borehole packers on fracture zone model recovery. We found the fracture zone conductivities with the inclusion of packers were comparable to similar trials excluding the use of packers regardless of electrical potential changes. The misplacement of fracture regularization disconnects (FRDs) can easily be misinterpreted as actual fracture locations. Conductivities within these misplaced disconnects were near the starting model value and removing smoothing between boreholes and assumed fracture locations helped in identifying incorrectly located FRDs. Analysis confirmed improved model sensitivity when regularization disconnects were (1) applied along the boreholes and fracture zones, and (2) FRDs were placed where actual fractures existed. Our findings demonstrate that structural constraints used after careful evaluation of a priori information are critical to improve imaging of fracture electrical conductivities, locations and orientations.

geophysics, inversion, resistivity, fracture, cont↗

Nonperturbative analysis of field theories quantized on the light cone (Final Scientific Report for ER41087)

The primary focus of the work was the development of methods for the nonperturbative solution of quantum chromodynamics (QCD) in a form that yields wave functions for the eigenstates, from which hadronic properties can be computed. The principal approach was to use a light-front Hamiltonian formulation. In light-front coordinates, t+z/c plays the role of time, with t the ordinary time, z a space direction, and c the speed of light. This leads to a relativistic formulation that retains useful characteristics of nonrelativistic treatments. A bound state of many constituents can be represented by wave functions that define probabilities for each possible arrangement of internal momenta. These functions satisfy integral equations that can be approximated numerically to yield a matrix representation. The matrix problem can be solved by iterative methods. The approximate wave functions can then be used to compute properties of the bound state. Methods have been developed for model theories and gauge theories, including quantum electrodynamics and theories that are supersymmetric. The work has required the development of new numerical algorithms and computer codes for singular integral equations and eigenvalue problems. A key aspect of the work is the construction of practical procedures for nonperturbative regularization and renormalization. Two methods of regularization have been studied. One is the addition of heavy Pauli--Villars (PV) particles to the Lagrangian, with their metrics and couplings tuned to provide the necessary cancellations in the regularization. The other method of regularization is the addition of supersymmetric partners, to extend a theory to a supersymmetric form. The supersymmetric theories were solved by the supersymmetric discrete light-cone quantization (SDLCQ) method. The most significant accomplishments of the project were the SDLCQ calculation of direct evidence for a Maldacena duality conjecture, construction of a practical light-front quantization for QED in an arbitrary covariant gauge, and invention of the light-front coupled-cluster method, designed to eliminate the need for Fock-space truncations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗