Search NASA⌕ Search

SEARCH · Search NASA

Results for “scoring system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Machine-learning Solution for Automatic Spacesuit Motion Recognition and Measurement from Conventional Video

Extravehicular Activity (EVA) spacesuits exhibit unique movement patterns due to their design characteristics. Mobility assessments using traditional motion capture systems are cost prohibitive and not feasible for some training conditions (e.g., simulated lunar outdoor terrain). This paper aims to present the ongoing development of machine learning solutions to quantify suit motions from conventional videos without special sensors or hardware. Given the fast growth in deep/machine learning technologies, external expertise was sought from open-source communities. This was expected to accelerate development and provide more cost-effective, time-saving solutions. This work was selected for a NASA Crowdsourcing project through an agency-wide solicitation. Partnerships were formed with the NASA JSC Center of Excellence for Collaborative Innovation and an execution crowdsourcing platform partner to solicit framework developments from external contenders. NASA provided contenders with video clips of spacesuits and simultaneously measured motion capture data during EVA simulation tasks. The contenders used this data to train and develop generalized algorithms to predict motions. At the end of the crowdsourcing event, five solutions were selected from 250 submissions. Each submission was tested and scored using video clips not previously disclosed to the contenders. The scoring metrics measured how well the algorithm detected the suit shape, the 2D suit joint detection accuracy, and 3D joint detection accuracy. The winning solution was able to achieve roughly 85% prediction accuracy (weighted combination of scoring metrics). Overall, the algorithms could efficiently detect various types of spacesuits and motions across different EVA simulation environments such as the Neutral Buoyancy Lab (NBL). However, 3D joint identification is less reliable when parts of the suit were obstructed in the image. After continued improvements and validation, the fully developed system will enable EVA stakeholders to quantify suit kinematic patterns, which can help optimize suit, hardware, and task designs.

Linh Vu↗

Objective Structured Clinical Evaluation (OSCE) of an Artificial Intelligence (AI) Clinical Decision Support System (CDSS) Tool

BACKGROUND Objective Structured Clinical Evaluations (OSCEs) have long been established as a robust methodology for summative assessment of clinical skills and decision-making during medical education. The recent integration of Artificial Intelligence (AI) into clinical decision-making processes has prompted the need for novel evaluation frameworks to assess the efficacy and reliability of AI clinical decision support system (CDSS) tools. This abstract outlines the process of quantitatively evaluating a novel CDSS (“Doc in a Box” Google 2024) trained on curated medical spaceflight data in the psychomotor domain as it interfaces with a human volunteer acting as the crew medical officer (CMO). PURPOSE The AI CDSS under review was developed as part of the Lunar Command and Control Interoperability (LuCCI) project, which is intended to address a gap in how Lunar Surface Systems (LSS) would interoperate across multiple programs, commercial partners, and international partners. The project objective is to define, prototype, integrate, and evaluate an interoperable lunar command, control, data, and software reference architecture to enable autonomy and informatics capability through common standards across LSS. A multi-modal AI-based CDSS compatible with Federated LSS will assist clinicians in diagnosing and managing complex medical conditions by providing evidence-based recommendations through predictive analytics. Given the critical role of decision-support as NASA continues to evolve its Earth-independent medical operations (EIMO), it is imperative to ensure that such AI tools perform reliably and align with clinical standards during progressive lunar and Martian exploration class missions. METHODS The OSCE framework, traditionally used for evaluating human clinicians, was adapted to assess the AI tool's decision-making capabilities in simulated clinical scenarios. In this adapted OSCE, the AI CDSS was tested across a series of structured clinical scenarios designed to mimic real-life spaceflight patient cases. These scenarios included a range of conditions and complexities, allowing for comprehensive assessment of the tool's performance. Key evaluation metrics included accuracy of diagnosis, timeliness of decision-making, and appropriate recommendations for therapies. The OSCE was scored by human physician evaluators who assessed the AI's recommendations in comparison with expert clinicians' medical decision making to ensure alignment with best practices and the standard of care. RESULTS Preliminary results indicate that the AI CDSS demonstrated high accuracy in diagnostic recommendations and decision support across various scenarios. However, certain limitations were noted, such as occasional discrepancies in handling complex or nuanced cases that required a more contextual understanding. Additionally, the tool scored higher on the diagnostic portion of the rubric, with lower scores in the therapeutic recommendations. These findings highlight the importance of continuous refinement and validation of AI tools through rigorous evaluation frameworks like the OSCE. The adaptation of OSCEs for AI tools presents several advantages, including a structured and reproducible approach to evaluation, the ability to test AI systems in diverse clinical scenarios, and the opportunity to benchmark AI performance against established clinical standards to permit charting of future progress as aerospace medicine evolves as a discipline. Remaining challenges include ensuring that these evaluations capture the full spectrum of clinical decision-making scenarios that will be confronted by CMOs during missions and adequately reflecting real-world variability of the austere spaceflight environment. CONCLUSION Employing OSCEs to evaluate AI clinical decision support tools offers a promising approach to validating their clinical utility and efficacy. This methodology not only provides insights into the tool's performance but also fosters ongoing improvement and alignment with standard of care practices. Future research should focus on refining these evaluation processes and addressing limitations to enhance the integration of AI tools in clinical spaceflight settings. REFERENCES Scott S, Hearns V, Barker MA. Testing Clinical Skills: A Look at the OSCE and USMLE Clinical Skills Exams. S D Med. 2019 Oct;72(10):451-453. Majumder MAA, Kumar A, Krishnamurthy K, Ojeh N, Adams OP, Sa B. An evaluative study of objective structured clinical examination (OSCE): students and examiners perspectives. Adv Med Educ Pract. 2019 Jun 5;10:387-397. Karam VY, Park YS, Tekian A, Youssef N. Evaluating the validity evidence of an OSCE: results from a new medical school. BMC Med Educ. 2018 Dec 20;18(1):313.

Ariana M Nelson↗

Identifying schools at high-risk for elevated lead in drinking water using only publicly available data

Estimating the risk of lead contamination of schools' drinking water at the State level is a complex, important, and unexplored challenge. Variable water quality among water systems and changes in water chemistry during distribution affect lead dissolution rates from pipes and fittings. In addition, the locations of lead-bearing plumbing materials are uncertain. We tested the capability of six machine learning models to predict the likelihood of lead contamination of drinking water at the schools' taps using only publicly available datasets. The predictive features used in the models correspond to those with a proven correlation to the dominant, but commonly unavailable, factors that govern lead leaching: the presence of lead-bearing plumbing materials and water quality conducive to lead corrosion. By combining water chemistry data from public reports, socioeconomic information from the US census, and spatial features using Geographic Information Systems, we trained and tested models to estimate the likelihood of lead contaminated tap water in over 8,000 schools across California and Massachusetts. Our best-performing model was a Random Forest, with a 10-fold cross validation score of 0.88 for Massachusetts and 0.78 for California using the average Area Under the Receiver Operating Characteristic Curve (ROC AUC) metric. The model was then used to assign a lead leaching risk category to half of the schools across California (the other half was used for training). There was good agreement between the modeled risk categories and the actual lead leaching outcomes for every school; however, the model overestimated the lead leaching risk in up to 17% of the schools. This model is the first of its kind to offer a tool to predict the risk of lead leaching in schools at the State level. Further use of this model can help deploy limited resources more effectively to prevent childhood lead exposure from school drinking water.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

SU-E-T-350: Verification of Gating Performance of a New Elekta Gating Solution: Response Kit and Catalyst System

Purpose: In this work, we have tested the performance of new respiratory gating solutions for Elekta linacs. These solutions include the Response gating and the C-RAD Catalyst surface mapping system.Verification measurements have been performed for a series of clinical cases. We also examined the beam on latency of the system and its impact on delivery efficiency. Methods: To verify the benefits of tighter gating windows, a Quasar Respiratory Motion Platform was used. Its vertical-motion plate acted as a respiration surrogate and was tracked by the Catalyst system to generate gating signals. A MatriXX ion-chamber array was mounted on its longitudinal-moving platform. Clinical plans are delivered to a stationary and moving Matrix array at 100%, 50% and 30% gating windows and gamma scores were calculated comparing moving delivery results to the stationary result. It is important to note that as one moves to tighter gating windows, the delivery efficiency will be impacted by the linac's beam-on latency. Using a specialized software package, we generated beam-on signals of lengths of 1000ms, 600ms, 450ms, 400ms, 350ms and 300ms. As the gating windows get tighter, one can expect to reach a point where the dose rate will fall to nearly zero, indicating that the gating window is close to beam-on latency. A clinically useful gating window needs to be significantly longer than the latency for the linac. Results: As expected, the use of tighter gating windows improved delivery accuracy. However, a lower limit of the gating window, largely defined by linac beam-on latency, exists at around 300ms. Conclusion: The Response gating kit, combined with the C-RAD Catalyst, provides an effective solution for respiratorygated treatment delivery. Careful patient selection, gating window design, even visual/audio coaching may be necessary to ensure both delivery quality and efficiency. This research project is funded by Elekta.

07 ISOTOPE AND RADIATION SOURCES↗

MO-DE-207B-03: Improved Cancer Classification Using Patient-Specific Biological Pathway Information Via Gene Expression Data

Purpose: To develop an efficient, pathway-based classification system using network biology statistics to assist in patient-specific response predictions to radiation and drug therapies across multiple cancer types. Methods: We developed PICS (Pathway Informed Classification System), a novel two-step cancer classification algorithm. In PICS, a matrix m of mRNA expression values for a patient cohort is collapsed into a matrix p of biological pathways. The entries of p, which we term pathway scores, are obtained from either principal component analysis (PCA), normal tissue centroid (NTC), or gene expression deviation (GED). The pathway score matrix is clustered using both k-means and hierarchical clustering, and a clustering is judged by how well it groups patients into distinct survival classes. The most effective pathway scoring/clustering combination, per clustering p-value, thus generates various ‘signatures’ for conventional and functional cancer classification. Results: PICS successfully regularized large dimension gene data, separated normal and cancerous tissues, and clustered a large patient cohort spanning six cancer types. Furthermore, PICS clustered patient cohorts into distinct, statistically-significant survival groups. For a suboptimally-debulked ovarian cancer set, the pathway-classified Kaplan-Meier survival curve (p = .00127) showed significant improvement over that of a prior gene expression-classified study (p = .0179). For a pancreatic cancer set, the pathway-classified Kaplan-Meier survival curve (p = .00141) showed significant improvement over that of a prior gene expression-classified study (p = .04). Pathway-based classification confirmed biomarkers for the pyrimidine, WNT-signaling, glycerophosphoglycerol, beta-alanine, and panthothenic acid pathways for ovarian cancer. Despite its robust nature, PICS requires significantly less run time than current pathway scoring methods. Conclusion: This work validates the PICS method to improve cancer classification using biological pathways. Patients are classified with greater specificity and physiological relevance as compared to current gene-specific approaches. Focus now moves to utilizing PICS for pan-cancer patient-specific treatment response prediction.

60 APPLIED LIFE SCIENCES↗

Renal tumor structured reporting including nephrometry score and beyond: what the urologist and interventional radiologist need to know

The purpose of this paper is to describe cross-sectional imaging anatomic and morphologic parameters of solid renal tumors that urologists and interventional radiologists need for precise management, review the commonly used terms and descriptors of those parameters, and suggest a comprehensive reporting system for detected masses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A meta-learning based distribution system load forecasting model selection framework

This paper presents a meta-learning based, automatic distribution system load forecasting model selection framework. Furthermore, the framework includes the following processes: feature extraction, candidate model preparation and labeling, offline training, and online model recommendation. Using load forecasting needs and data characteristics as input features, multiple metalearners are used to rank the candidate load forecast models based on their forecasting accuracy. Then, a scoring-voting mechanism is proposed to weights recommendations from each meta-leaner and make the final recommendations. Heterogeneous load forecasting tasks with different temporal and technical requirements at different load aggregation levels are set up to train, validate, and test the performance of the proposed framework. Simulation results demonstrate that the performance of the meta-learning based approach is satisfactory in both seen and unseen forecasting tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the Added Value of Miniature X-Ray in the Setting of Portable Ultrasound in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in low-Earth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

J G Steller↗

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

Corral Summit Pumped Storage Hydropower Hybrid: Site Suitability Assessment

In 2024, Idaho National Laboratory (INL) and Pacific Northwest National Laboratory (PNNL) initiated a technical-assistance project to support Cat Creek Energy, LLC, (CCE) in evaluating site suitability for the proposed Corral Summit Pumped Storage Hydropower (PSH) project in south-central Idaho near Mackay Reservoir. The Corral Summit facility incorporates battery storage and photovoltaic (PV) solar arrays in a Trybrid configuration to deliver large-volume long-duration (LVLD) storage solutions for rural electric cooperatives in eastern Idaho. The evaluation process focused on determining the most-suitable location for the upper reservoir of the PSH system, guided by a comprehensive assessment framework spanning multiple categories, including physical characteristics, environmental constraints, building infrastructure, regulatory constraints, cultural resources and sensitivity, social factors, and power market and grid integration. Each site was analyzed based on a ranking scale (0–1), which scores ranging from “severely disfavored” to “highly favored,” allowing detailed comparisons of site-specific conditions. Categories such as hydraulic head, utilities corridor, land ownership, and transmission-grid limitations emerged as key contributors to the overall assessment. Site 2 (Idaho Trust) demonstrated a slight advantage over Site 1 (Bureau of Land Management) primarily due to favorable outcomes in regulatory constraints, building infrastructure, and power-market integration. However, Site 1 outperformed Site 2 in factors related to physical characteristics and social factors. The report emphasizes the need for further evaluation of both sites before clear determination of which site is preferred, due to the limited information available on either site at the time of this report. Key areas of evaluation to clearly define the preferred site are ecological impacts, cultural-resource surveys, and economic-feasibility assessments. For successful project execution, recommended follow-up actions include seismic and geotechnical surveys, groundwater and habitat monitoring, regulatory reviews of water rights and right-of-way agreements, cultural engagement with local tribal governments, and enhanced stakeholder strategies. These efforts will ensure the Corral Summit Trybrid facility meets local energy needs while balancing environmental, social, and regulatory responsibilities.

13 - HYDRO ENERGY↗

Fine-Grained Power and Energy Attribution on AMD GPU/APU-Based Exascale Nodes

Modern exascale GPU- and APU-based systems provide multiple power and energy sensors, but differences in scope, update rate, timing, and filtering complicate the attribution of short-lived accelerator activity. This paper presents a methodology to characterize and correct these effects on Cray EX systems with AMD Instinct MI250X GPUs (Frontier) and MI300A APUs (Portage). Using controlled square-wave workloads, we quantify update intervals, delay, aliasing, and variability across up to 512 GPUs and 480 APUs with on-chip (rocm-smi/amd-smi) and off-chip Cray Power Management sensors. We reconstruct power from cumulative energy counters to achieve faster response times, validate it against on-chip, off-chip, and node-level sensors, and integrate the resulting streams into a Score-P/PAPI-based tool for time-aligned, phase-level attribution. Applied to rocHPL, rocHPL-MxP, and HPG-MxP, the method separates energy savings due to reduced runtime from changes in power. Mixed precision reduces node energy on Frontier by 79% for rocHPL-MxP and 31% for HPG-MxP, with similar trends on Portage. These results provide portable guidance for sensor validation and power-aware optimization on current and future exascale systems.

Mcdaniel, Adam [ORNL] (ORCID:000000016926028X)↗

Genetic risk for Alzheimer’s dementia predicts motor deficits through multi-omic systems in older adults

Alzheimer’s disease manifests with both cognitive and motor deficits. However, the degree to which genetic risk of Alzheimer’s dementia contributes to late-life motor impairment, and the specific molecular systems underlying these associations, are uncertain. Here, we adopted an integrative multi-omic approach to assess genetic influence on motor impairment in older adults and identified key molecular pathways that may mediate this risk. We built a polygenic risk score for clinical diagnosis of Alzheimer’s dementia (AD-PRS) and examined its relationship to several motor phenotypes in 1885 older individuals from two longitudinal aging cohorts. We found that AD-PRS was associated with a previously validated composite motor scores and their components. The major genetic risk factor for sporadic Alzheimer’s dementia, the APOE/TOMM40 locus, was not a major driver of these associations. To identify specific molecular features that potentially medicate the genetic risk into motor dysfunction, we examined brain multi-omics, including transcriptome, DNA methylation, histone acetylation (H3K9AC), and targeted proteomics, as well as diverse neuropathologies. We found that a small number of factors account for the majority of the influence of AD-PRS on motor function, which comprises paired helical filament tau-tangle density, H3K9AC in specific chromosomal regions encoding genes involved in neuromuscular process. These multi-omic factors have the potential to elucidate key molecular mechanisms developing motor impairment in the context of Alzheimer’s dementia.

60 APPLIED LIFE SCIENCES↗

Artificial intelligence-empowered cellular morphometric risk score improves prognostic stratification of cutaneous squamous cell carcinoma

Abstract Background Risk stratification of cutaneous squamous cell carcinoma (cSCC) is essential for managing patients. Objectives To determine if artificial intelligence and machine learning might help to stratify patients with cSCC by risk using more than solely clinical and histopathological factors. Methods We retrieved a retrospective cohort of 104 patients whose cSCCs had been excised with clear margins. Clinical and histopathological risk factors were evaluated. Haematoxylin and eosin-stained slides were scanned and analysed by an algorithm based on the stacked predictive sparse decomposition technique. Cellular morphometric biomarkers (CMBs) were identified via machine learning and used to derive a cellular morphometric risk score (CMRS) that classified cSCCs into clusters of differential prognoses. Concordance analysis, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were calculated and compared with results obtained with the Brigham and Women’s Hospital (BWH) staging system. The performance of the combination of the BWH staging system and the CMBs was also analysed. Results There were no differences among the CMRS groups in terms of clinical and histopathological risk factors and T-stage assignment, but there were significant differences in prognosis. Combining the CMRS with BWH staging systems increased distinctiveness and improved prognostic performance. C-indices were 0.91 local recurrence and 0.91 for nodal metastasis when combining the two approaches. The NPV was 94.41% and 96.00%, the PPV was 36.36% and 41.67%, and accuracy reached 86.75% and 89.16%, respectively, with the combined approach. Conclusions CMRS is helpful for cSCC risk stratification beyond classic clinical and histopathological risk features. Combining the information from the CMRS and the BWH staging system offers outstanding prognostic performance for patients with high-risk cSCC.

Pérez-Baena, Manuel J.↗

Trust Model System for the Energy Grid of Things Network Communications

Network communication is crucial in the Energy Grid of Things (EGoT). Without a network connection, the energy grid becomes just a power grid where the energy resources are available to the customer uni-directionally. A mechanism to analyze and optimize the energy usage of the grid can only happen through a medium, a communications network, that enables information exchange between the grid participants and the service provider. Security implementers of EGoT network communication take extraordinary measures to ensure the safety of the energy grid, a critical infrastructure, as well as the safety and privacy of the grid participants. With the dynamic nature of network communication of the EGoT, the information provided by the customer or the service provider can be falsified by a malicious attacker. Therefore, a trust model is necessary to monitor any abnormal activities. This paper describes a distributed trust model system that meets the need of the EGoT. This paper describes methods for evaluating and improving the distributed trust model using standard hypothesis testing metrics such as true positive, false positive, true negative, false negative, equal error rate, and F1 score. Example calculations are shown based on generated sample data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-F-J-147: Magnetic Field Dose Response Considerations for a Linac Monitor Chamber

Purpose: The impact of magnetic fields on the readings of a linac monitor chamber have not yet been investigated. Herein we examine the total dose response as well as any deviations in the beam parameters of flatness and symmetry when a Varian monitor chamber is irradiated within an applied magnetic field. This work has direct application to the development of Linac-MR systems worldwide. Methods: A Varian monitor chamber was modeled in the Monte Carlo code PENELOPE and irradiated in the presence of a magnetic field with a phase space generated from a model of a Linac-MR prototype system. The magnetic field strength was stepped from 0 to 3.0T in both parallel and perpendicular directions with respect to the normal surface of the phase space. Dose to each of the four regions in the monitor chamber were scored separately for every magnetic field adaptation to evaluate the effect of the magnetic field on flatness and symmetry. Results: When the magnetic field is perpendicular to the phase space normal we see a change in dose response with a maximal deviation (10–25% depending on the chamber region) near 0.75T. In the direction of electron deflection we expectedly see opposite responses in chamber regions leading to a measured asymmetry. With a magnetic field parallel to the phase space normal we see no measured asymmetries, however there is a monotonic rise in dose response leveling off at about +12% near 2.5T. Conclusion: Attention must be given to correct for the strength and direction of the magnetic field at the location of the linac monitor chamber in hybrid Linac-MR devices. Elsewise the dose sampled by these chambers may not represent the actual dose expected at isocentre; additionally there may be a need to correct for the symmetry of the beam recorded by the monitor chamber. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

The Effect of Sensory Noise Created by Compliant and Sway-Referenced Support Surfaces on Postural Stability

The purpose of the present experiment was to compare in normal human subjects the differential effects on postural stability of introducing somatosensory noise via compliant and/or sway-referenced support surfaces during quiet standing. The use of foam surfaces (two thicknesses: thin (0.95cm) and thick (7.62cm)) and sway-referenced support allowed comparison between two different types of destabilizing factors that increased ankle/foot somatosensory noise. Under some conditions neck extensions were used to increase sensory noise by deviating the vestibular system from its optimal orientation for balance control. The impact of these conditions on postural control was assessed through objective measures of instability. Thick foam and sway-referenced support conditions generated comparable instability in subjects, as measured by equilibrium score and minimum time-to-contact. However, simultaneous application of the conditions resulted in greater instability, suggesting a higher level of generated sensory noise and thus, different receptor types affected during each manipulation. Indeed, sway-referenced support generated greater anterior-posterior center-of-mass (COM) sway, while thick foam generated greater medio-lateral COM sway and velocity. Neck extension had minimal effect on postural stability until combined with simultaneous thick foam and sway-referenced support. Thin foam never generated enough sensory noise to affect postural stability even with noise added by sway-reference support or neck extension. These results provide an interesting window into the central integration of redundant sensory information and indicate the postural impact of sensory inputs is not solely based on their existence, but also their level of noise.

Forth, Katharine E.↗

Automating Bug Report Classification with Few Shot Learning

Orthogonal defect classification (ODC) is a method used to categorize software defects, providing valuable insights into the development process. This study focuses on automating the classification of software bug reports into different ODC defect types using few shot learning, a machine learning approach that requires minimal labeled data. Previous research has manually classified bug reports or used traditional machine learning algorithms like linear support vector machine, achieving limited success. Our approach uses few shot learning to improve classification accuracy and efficiency. The results show a harmonic mean of recall and precision (i.e., the F1 score) of around 0.6 which is a performance improvement over previous methods. The results highlight the potential benefit of few shot learning techniques and their application in enhancing the safety and reliability of nuclear digital instrumentation and control (DI&C) systems. Future work will explore incorporating advanced techniques to supplement the model's training data and achieve better results.

42 - ENGINEERING↗

Corral Summit Pumped Storage Hydropower Hybrid Site Suitability Assessment (Rev.1)

In 2024, Idaho National Laboratory (INL) and Pacific Northwest National Laboratory (PNNL) initiated a technical-assistance project to support Cat Creek Energy, LLC, (CCE) in evaluating site suitability for the proposed Corral Summit Pumped Storage Hydropower (PSH) project in south-central Idaho near Mackay Reservoir. The Corral Summit facility incorporates battery storage and photovoltaic (PV) solar arrays in a Trybrid configuration to deliver large-volume long-duration (LVLD) storage solutions for rural electric cooperatives in eastern Idaho. The evaluation process focused on determining the most-suitable location for the upper reservoir of the PSH system, guided by a comprehensive assessment framework spanning multiple categories, including physical characteristics, environmental constraints, building infrastructure, regulatory constraints, cultural resources and sensitivity, social factors, and power market and grid integration. Each site was analyzed based on a ranking scale (0–1), which scores ranging from “severely disfavored” to “highly favored,” allowing detailed comparisons of site-specific conditions. Categories such as hydraulic head, utilities corridor, land ownership, and transmission-grid limitations emerged as key contributors to the overall assessment. Site 2 (Idaho Trust) demonstrated a slight advantage over Site 1 (Bureau of Land Management) primarily due to favorable outcomes in regulatory constraints, building infrastructure, and power-market integration. However, Site 1 outperformed Site 2 in factors related to physical characteristics and social factors. The report emphasizes the need for further evaluation of both sites before clear determination of which site is preferred, due to the limited information available on either site at the time of this report. Key areas of evaluation to clearly define the preferred site are ecological impacts, cultural-resource surveys, and economic-feasibility assessments. For successful project execution, recommended follow-up actions include seismic and geotechnical surveys, groundwater and habitat monitoring, regulatory reviews of water rights and right-of-way agreements, cultural engagement with local tribal governments, and enhanced stakeholder strategies. These efforts will ensure the Corral Summit Trybrid facility meets local energy needs while balancing environmental, social, and regulatory responsibilities.

13 - HYDRO ENERGY↗