Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

FAST INVERSION METHOD FOR DETERMINATION OF PLANETARY PARAMETERS FROM TRANSIT TIMING VARIATIONS

The transit timing variation (TTV) method relies on monitoring changes in timing of transits of known exoplanets. Non-transiting planets in the system can be inferred from TTVs by their gravitational interaction with the transiting planet. The TTV method is sensitive to low-mass planets that cannot be detected by other means. Here we describe a fast algorithm that can be used to determine the mass and orbit of the non-transiting planets from the TTV data. We apply our code, ttvim.f, to a wide variety of planetary systems to test the uniqueness of the TTV inversion problem and its dependence on the precision of TTV observations. We find that planetary parameters, including the mass and mutual orbital inclination of planets, can be determined from the TTV data sets that should become available in near future. Unlike the radial velocity technique, the TTV method can therefore be used to characterize the inclination distribution of multi-planet systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing topological phase transitions using high-harmonic generation

We report the prediction and realization of topological insulators have sparked great interest in experimental approaches to the classification of materials. The phase transition between non-trivial and trivial topological states is important, not only for basic materials science but also for next-generation technology, such as dissipation-free electronics. It is therefore crucial to develop advanced probes that are suitable for a wide range of samples and environments. Here we demonstrate that circularly polarized laser-field-driven high-harmonic generation is distinctly sensitive to the non-trivial and trivial topological phases in the prototypical three-dimensional topological insulator bismuth selenide. The phase transition is chemically initiated by reducing the spin–orbit interaction strength through the substitution of bismuth with indium atoms. We find strikingly different high-harmonic responses of trivial and non-trivial topological surface states that manifest themselves as a conversion efficiency and elliptical dichroism that depend both on the driving laser ellipticity and the crystal orientation. The origins of the anomalous high-harmonic response are corroborated by calculations using the semiconductor optical Bloch equations with pairs of surface and bulk bands. As a purely optical approach, this method offers sensitivity to the electronic structure of the material, including its nonlinear response, and is compatible with a wide range of samples and sample environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods

This documents contains the final report for the project "Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods" (DE-SC0007049) Executive Summary: Our research aimed to develop borehole measurement techniques capable of monitoring subsurface processes, such as changes in pore geometry and iron/sulfur geochemistry, associated with remediation of heavy metals and radionuclides. Previous work has demonstrated that geophysical method spectral induced polarization (SIP) can be used to assess subsurface contaminant remediation; however, SIP signals can be generated from multiple sources limiting their interpretation value. Integrating multiple geophysical methods, such as nuclear magnetic resonance (NMR) and magnetic susceptibility (MS), with SIP, could reduce the ambiguity of interpretation that might result from a single method. Our research efforts entails combining measurements from these methods, each sensitive to different mineral forms and/or mineral-fluid interfaces, providing better constraints on changes in subsurface biogeochemical processes and pore geometries significantly improving our understanding of processes impacting contaminant remediation. The Rifle Integrated Field Research Challenge (IFRC) site was used as a test location for our measurements. The Rifle IFRC site is located at a former uranium ore-processing facility in Rifle, Colorado. Leachate from spent mill tailings has resulted in residual uranium contamination of both groundwater and sediments within the local aquifer. Studies at the site include an ongoing acetate amendment strategy, native microbial populations are stimulated by introduction of carbon intended to alter redox conditions and immobilize uranium. To test the geophysical methods in the field, NMR and MS logging measurements were collected before, during, and after acetate amendment. Next, laboratory NMR, MS, and SIP measurements were collected on columns of Rifle sediments during acetate amendment. The laboratory experiments were designed to simulate the field experiments; changes in geophysical signals were expected to correlate with changes in redox conditions and iron speciation. Field MS logging measurements revealed vertically stratified magnetic mineralization, likely the result of detrital magnetic fraction within the bulk alluvium. Little to no change was observed in the MS data suggesting negligible production of magnetic phases (e.g. magnetite, pyrrhotite) as a result of sulfidogenesis. Borehole NMR measurements contained high levels of noise contamination requiring significant signal processing, and analysis suggests that any changes may be difficult to differentiate from simultaneous changes in water content. Laboratory MS and NMR measurements remained relatively stable throughout the course of the acetate amendment experiment, consistent with field measurements. However, SIP measurements changed during the acetate amendment associated with the formation of iron-sulfide mineral phases; a finding that is consistent with chemical analysis of the solid phase materials in the columns.

54 ENVIRONMENTAL SCIENCES↗

Determination of Silicon in Hydrazine

Inductively coupled plasma-mass spectrometry (ICP-MS) is a highly sensitive technique sometimes used for the trace determination of silicon at a mass-to-charge (m/z) ratio of 28, the most abundant natural isotope of silicon. Unfortunately, ICP-MS is unable to differentiate between other sources of m/z 28 and false positive results for silicon will result when other sources of m/z 28 are present. Nitrogen was a major source of m/z 28 and contributes to the m/z 28 signal when hydrazine sample or nitric acid preservative is introduced into the plasma. Accordingly, this work was performed to develop a sample preparation step coupled with an ICP-MS analysis that minimized non-silicon sources of m/z 28. In the preparatory step of this method, the hydrazine sample was first decomposed predominately to nitrogen gas and water with copper-catalyzed hydrogen peroxide. In the analysis step, ICP-MS was used without nitric acid preservative in samples or standards. Glass, a potential source of silicon contamination, was also avoided where possible. The method was sensitive, accurate, and reliable for the determination of silicon in monopropellant grade hydrazine (MPH) in AF-E-332 elastomer leaching tests. Results for silicon in MPH were comparable to those reported in the literature for other studies.

McClure, Mark B.↗

Sensitivity studies associated with dosimetry experiment interpretation

Document available in abstract form only, full text of document follows: Interpretation of reactor dosimetry experiments with C/E comparison requires precise knowledge of parameters involved in modeling. Some parameters have more weight than others on the calculated values. So, sensitivity studies should be conducted to verify the importance of these parameters. The conclusions of these studies are used to refine the experiment modeling, or to correct uncertainty calculations. The results of these sensitivity studies allow a post-irradiation analysis, which can justify the discarding of some atypical C/M values. Derived uncertainties may be improved by the sensitivity analyses. Beyond classical parameters as geometry or composition, this paper describes some specific sensitivity studies conducted for dosimetry irradiation in reactor, and presents conclusions. These studies are based on dosimeters irradiated in the EOLE reactor facility at Cadarache CEA center. Conclusions drawn from these studies are generic and can be applied to any dosimetry study. Calculations performed for these studies were realized using TRIPOLI-4 Monte Carlo code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monte Carlo study of electron-beam penetration and backscattering in multi-walled carbon nanotube materials: The effect of different scattering models

A systematic study of electron-beam penetration and backscattering in multi-walled carbon nanotube (MWCNT) materials for beam energies of {approx}0.3 to 30 keV is presented based on event-by-event Monte Carlo simulation of electron trajectories using state-of-the-art scattering cross sections. The importance of different analytic approximations for computing the elastic and inelastic electron-scattering cross sections for MWCNTs is emphasized. We offer a simple parameterization for the total and differential elastic-scattering Mott cross section, using appropriate modifications to the Browning formula and the Thomas-Fermi screening parameter. A discrete-energy-loss approach to inelastic scattering based on dielectric theory is adopted using different descriptions of the differential cross section. The sensitivity of electron penetration and backscattering parameters to the underlying scattering models is examined. Our simulations confirm the recent experimental backscattering data on MWCNT forests and, in particular, the steep increase of the backscattering yield at sub-keV energies as well as the sidewalls escape effect at high-beam energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-I-56: High-Precision Gamma-Ray Analysis of Medical Isotopes

Purpose: Advanced, time-resolved, Compton-suppressed gamma-ray spectroscopy with germanium detectors is implemented for assaying medical isotopes to study the radioactive decay process leading to a more accurate appraisal of the received dose and treatment planning. Lowell’s Array for Radiological Assay (LARA), a detector array that is comprised of six Compton-suppressed high-purity germanium detectors, is currently under development at UMass-Lowell which combines Compton-suppression and time-and-angle correlations to allow for highly efficient and highly sensitive measurements. Methods: Two isotopes produced Brookhaven Linac Isotope Producer (BLIP) were investigated. {sup 82}Sr which is the parent isotope for producing {sup 82}Rb is often used in cardiac PET. {sup 82}Sr gamma-ray spectrum is dominated by the 511keV photons from positron annihilation which prevent precise measurement of co-produced contaminant isotopes. A second project was to investigate the production of platinum isotopes. Natural platinum was bombarded with protons from 53MeV to 200MeV. The resulting spectrum was complicated due to the large number of stable platinum isotopes in the target, the variety of open reaction channels (p,xn), (p,pxn), (p,axn). Results: By using face-to-face NaI(Tl) counters 90-degrees to the Compton-suppressed germaniums to detect the 511keV photons, a much cleaner and more sensitive measurement of {sup 85}Sr and other contaminants was obtained. For the platinum target, we identified the production of {sup 188–189–191–195}Pt, {sup 191–192–193–194–195–196}Au and {sup 186–188–189–190–192–194–189–190–192–194}Ir. For example, at the lower energies (53 and 65MeV), we measured {sup 191}Pt production cross-sections of 144mb and 157mb. Considerable care was needed in following the process of dissolving and diluting the samples to get consistent results. The new LARA array will help us better ascertain the absolute efficiency of the counting system and more reliable production cross-sections. Conclusion: Modern HPGe spectroscopic techniques provide enhanced sensitivity, promising precise quantification of the quality of radioisotopes used in medical physics. Using new decay information may have non-trivial impact on treatment planning and dose-assessment.

07 ISOTOPE AND RADIATION SOURCES↗

Surface analysis insight note: Synthetic line shapes, integration regions and relative sensitivity factors

Here, methods for estimating photoemission intensity from X-ray photoelectron spectroscopy data are examined. The role played by “synthetic” bell-shaped curves, integration intervals, background curves, and the use of relative sensitivity factors (RSFs) in reporting percentage atomic concentration for a sample is presented. In particular, photoemission lines with differing energy distributions obtained from the NaCl sample surface are used to demonstrate how a comparison of photoemission intensities is dependent on the line shapes, background curves, and appropriate use of RSFs.

42 ENGINEERING↗

SU-E-J-08: Comparison of Unintended Radiation Doses to Organs at Risk Resulting From the Out-Of-Field Therapeutic Beams and From Image-Guidance X-Ray Procedures

Purpose: The unintended radiation dose to organs at risk (OAR) can be contributed from imaging guidance procedures as well as from leakage and scatter of therapeutic beams. This study compares the imaging dose with the unintended out-of-field therapeutic dose to patient sensitive organs. Methods: The Monte Carlo EGSnrc user codes, BEAMnrc and DOSXYZnrc, were used to simulate kV X-ray sources from imaging devices as well as the therapeutic IMRT/VMAT beams and to calculate doses to target and OARs on patient treatment planning CT images. The accuracy of the Monte Carlo simulations was benchmarked against measurements in phantoms. The dose-volume histogram was utilized in analyzing the patient organ doses. Results: The dose resulting from Standard Head kV-CBCT scans to bone and soft tissues ranges from 0.7 to 1.1 cGy and from 0.03 to 0.3 cGy, respectively. The dose resulting from Thorax scans on the chest to bone and soft tissues ranges from 1.1 to 1.8 cGy and from 0.3 to 0.6 cGy, respectively. The dose resulting from Pelvis scans on the abdomen to bone and soft tissues range from 3.2 to 4.2 cGy and from 1.2 to 2.2 cGy, respectively. The out-of-field doses to OAR are sensitive to the distance between the treated target and the OAR. For a typical Head-and-Neck IMRT/VMAT treatment the out-of-field doses to eyes are 1–3% of the target dose, or 2–6 cGy per fraction. Conclusion: The imaging doses to OAR are predictable based on the imaging protocols used when OARs are within the imaged volume and can be estimated and accounted for by using tabulated values. The unintended out-of-field doses are proportional to the target dose, strongly depend on the distance between the treated target and OAR, and are generally higher comparing to the imaging dose. This work was partially supported by Varian research grant VUMC40590.

60 APPLIED LIFE SCIENCES↗

Juniper Pollen Hotspots in the Southwest

Rationale: Juniperus pollen is a major allergen in Texas, Oklahoma, and New Mexico. While the bulk of pollen may be released in rural areas, large amounts of pollen can be transported to urban areas. Major juniper species in the region include: Juniperus ashei, J. virginiana, J. pinchotii, and J. monosperma. Pollen release is virtually continuous beginning in late September with J. pinchotii and ending in May with J. monosperma. Urban areas in the region were evaluated for the potential of overlapping seasons in order to inform sensitive individuals. Methods: Burkard volumetric pollen traps were established for two consecutive spring seasons at 6 sites in northern New Mexico and 6 sites for two consecutive winter and fall seasons in Texas and Oklahoma Standard methods were used in the preparation and analysis of slides. Results: The Dallas-Fort Worth Metroplex is home to over 6 million people. It is adjacent to populations of J. pinchotii, J. virginiana, and J. ashei. Peak concentration near Dallas for J. ashei in 2011 was 5891 pollen grains/m3 in January 7th. The peak date for J. pinchotii at an upwind sampling location in San Marcos, TX was November 1, 2010 and peak for J. virginiana at a nearby station in Tulsa, OK was November 1, 2010 and peak for J. virginiana at a nearby station in Tulsa, OK was February 20, 2011. Amarillo, TX is adjacent to J. pinchotii, J. ashei, and J. monosperma populations and may be subject to juniper pollen from September through May. Conclusions: Considering the overlapping distributions of juniper trees and the overlapping temporal release of pollen, sensitive patients may benefit from avoiding hotspots.

Bunderson, L. D.↗

Meta-uncertainty for particle image velocimetry

Uncertainty quantification for Particle Image Velocimetry (PIV) is critical for comparing experimentally measured flow fields with Computational Fluid Dynamics (CFD) results, and model design and validation. However, PIV features a complex measurement chain with coupled, non-linear error sources, and quantifying the uncertainty is challenging. Multiple assessments show that none of the current methods can reliably measure the actual uncertainty across a wide range of experiments, and estimates can vary. Because the current methods differ in assumptions regarding the measurement process and calculation procedures, it is not clear which method is best to use for an experiment where the error distribution is unknown. To address this issue, we propose a method to estimate an uncertainty method's sensitivity and reliability, termed the Meta-Uncertainty. The novel approach is automated, local, and instantaneous, and based on perturbation of the recorded particle images. We developed an image perturbation scheme based on adding random unmatched particles to the interrogation window pair considering the signal-to-noise (SNR) of the correlation plane. Each uncertainty scheme's response to several trials of random particle addition is used to estimate a reliability metric, defined as the rate of change of the inter-quartile range (IQR) of the uncertainties with increasing levels of particle addition. We also propose applying the meta-uncertainty as a weighting metric to combine uncertainty estimates from individual schemes, based on ideas from the consensus forecasting literature. We use planar and stereo PIV measurements across a range of canonical flows to assess the performance of the uncertainty schemes. Further, a novel method is introduced to assess an uncertainty scheme's performance based on a quantile comparison of the error and uncertainty distributions, generalizing the current method of comparing the RMS of the two distributions. Here, the results show that the combined uncertainty method outperforms the individual methods, and this work establishes the meta-uncertainty as a useful reliability assessment tool for PIV uncertainty quantification.

47 OTHER INSTRUMENTATION↗

Gravitational lens modeling with basis sets

We present a strong lensing modeling technique based on versatile basis sets for the lens and source planes. Our method uses high performance Monte Carlo algorithms, allows for an adaptive build up of complexity, and bridges the gap between parametric and pixel based reconstruction methods. We apply our method to a Hubble Space Telescope image of the strong lens system RX J1131-1231 and show that our method finds a reliable solution and is able to detect substructure in the lens and source planes simultaneously. Using mock data, we show that our method is sensitive to sub-clumps with masses four orders of magnitude smaller than the main lens, which corresponds to about 10{sup 8}M{sub ⊙}, without prior knowledge of the position and mass of the sub-clump. The modeling approach is flexible and maximizes automation to facilitate the analysis of the large number of strong lensing systems expected in upcoming wide field surveys. The resulting search for dark sub-clumps in these systems, without mass-to-light priors, offers promise for probing physics beyond the standard model in the dark matter sector.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of the Newtonian Gravitational Constant Using Atom Interferometry

We present a new measurement of the Newtonian gravitational constant G based on cold-atom interferometry. Freely falling samples of laser-cooled rubidium atoms are used in a gravity gradiometer to probe the field generated by nearby source masses. In addition to its potential sensitivity, this method is intriguing as gravity is explored by a quantum system. We report a value of G=6.667x10{sup -11} m{sup 3} kg{sup -1} s{sup -2}, estimating a statistical uncertainty of {+-}0.011x10{sup -11} m{sup 3} kg{sup -1} s{sup -2} and a systematic uncertainty of {+-}0.003x10{sup -11} m{sup 3} kg{sup -1} s{sup -2}. The long-term stability of the instrument and the signal-to-noise ratio demonstrated here open interesting perspectives for pushing the measurement accuracy below the 100 ppm level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Challenges and Lessons Learned in Applying Sensitivity Analysis to Building Stock Energy Models

Uncertainty Analysis (UA) and Sensitivity Analysis (SA) offer essential tools to determine the limits of inference of a model and explore the factors which have the most effect on the model outputs. However, despite a well established body of work applying UA and SA to models of individual buildings, a review of the literature relating to energy models for larger groups of buildings undertaken by Fennell et al. (2019) highlighted very limited application at larger scales. This contribution describes the efforts undertaken by a group of research teams in the context of IEA-EBC Annex 70 working with a diverse set of Building Stock Models (BSMs) to apply global sensitivity analysis methods and compare their results. Since BSMs are a class of model defined by their output and coverage rather than their structure and inputs, they represent a diverse set of modelling approaches. Key challenges for the application of SA are identified and explored, including the influence of model form, input data types and model outputs. This study combines results from 7 different modelling teams, each using different models across a range of urban areas to explore these challenges and begin the process of developing standardised workflows for SA of BSMs.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers in kilovoltage x rays

For ion chambers with cavities open to the surrounding atmosphere, the response measured at a given temperature and pressure must be corrected using the standard temperature-pressure correction factor (P{sub TP}). A previous paper based solely on Monte Carlo simulations [D. J. La Russa and D. W. O. Rogers, Med. Phys. 33, 4590-4599 (2006)] pointed out the shortcomings of the P{sub TP} correction factor when used to correct the response of non-air-equivalent chambers for low-energy x-ray beams. This work presents the results of several experiments that corroborate these calculations for a number of ion chambers. Monte Carlo simulations of the experimental setup revealed additional insight into the various factors affecting the extent of the breakdown of P{sub TP}, including the effect of impurities and the sensitivity to chamber dimensions. For an unfiltered 60 kV beam, the P{sub TP}-corrected response of an NE 2571 ion chamber measured at 0.7 atm was 2.5% below the response measured at reference conditions. In general, Monte Carlo simulations of the experimental setup using EGSnrc were within 0.5% of measured values. EGSnrc-calculated values of air kerma calibration coefficients (N{sub K}) at low x-ray energies are also provided as a means of estimating the level of impurities in the chambers investigated. Calculated values of N{sub K} normalized to the value measured for a 250 kV beam were obtained for three chambers and were within 1% of experiment with one exception, the Exradin A12 in a 50 kV beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Complementary bimodal approach to monitoring of photodynamic therapy with targeted nanoconstructs: numerical simulations

We propose a new approach to monitoring photodynamic therapy (PDT) of glioblastoma with the use of targeted nanoconstructs containing a photosensitiser (PS) [benzoporphyrin derivative (BPD)] and IRDye800 dye, antibodies for efficient accumulation of the drug in a tumour, and a chemotherapeutic agent for combined effect on tumour cells. Application of IRDye800 is determined by the shift of its absorption and fluorescence spectra to the near-IR range with respect to BPD that ensures a higher imaging depth. Monitoring of PDT is based on the simultaneous fluorescence and optoacoustic (OA) imaging. Fluorescence imaging provides visualisation of fluorescence agents with high molecular sensitivity and monitoring of the effectiveness of PDT by PS photobleaching. OA allows one to examine the vascular pattern of the tumour environment, as well as assess the depth of the tumour. IRDye800 is a better contrast agent in comparison to BPD due to red-shifted spectral characteristics and a higher fluorescence quantum yield. Monte Carlo simulations combined for OA simulations with K-wave modelling allowed the feasibility of the complementary approach to be studied and demonstrated that this combination allows one to localise a tumour with a size of 2 mm at depths from 100 μm to 2 mm. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-334: Dosimetric Impacts of Organ at Risk (OAR) Contour Errors in Prostate Volumetric Modulated Arc Therapy (VMAT) Planning: A Sensitivity Study

Purpose: To investigate the dosimetric impacts of OAR contour errors in prostate VMAT planning with a sensitivity analysis method. Methods: Ten randomly selected prostate VMAT patients were used to simulate OAR contour error in rectum and bladder. For each OAR 12 even spaced contour control points were selected in every three slices. For each simulation, only one of the control points was simulated to move inwards or outwards by up to 6 voxels and coordinates of adjacent voxels to that moving control point were moved accordingly with a 3D-spline smooth function. An in-house software was used to predict OARs dosimetric endpoints based on geometric relationship between PTV and OAR. In this study, the V75, V70, V65, V60 of rectum and V80, V75, V70, V65 of bladder with and without perturbed contours were calculated and compared. Results: The percentage of OAR dose volume difference around the reference OAR contours were plotted as iso-error lines overlaid on CT images. The significant difference was shown in OAR contours adjacent to the PTV where high dose gradient exists. When one of the 12 points adjacent to the PTV moved up to 6 voxels, maximum errors of 1.99%, 2.46%, 2.89%, and 3.19% were found in V75, V70, V65, and V60 of the rectum, and 1.59%, 1.67%, 1.87%, and 1.90% were found in V80, V75, V70, and V65 of the bladder, respectively. Conclusion: We can quantify the dosimetric impact of OAR contouring error by evaluating the percentage of OAR dose volume changes in prostate VMAT planning. For the adaptive radiation therapy, the iso-error lines can provide the planner a guideline that which portion of contour needed to be checked carefully because dosimetric sensitivity of contour errors are different for different part of contours.

60 APPLIED LIFE SCIENCES↗