Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Study of radar pulse compression for high resolution satellite altimetry

Pulse compression techniques are studied which are applicable to a satellite altimeter having a topographic resolution of + 10 cm. A systematic design procedure is used to determine the system parameters. The performance of an optimum, maximum likelihood processor is analysed, which provides the basis for modifying the standard split-gate tracker to achieve improved performance. Bandwidth considerations lead to the recommendation of a full deramp STRETCH pulse compression technique followed by an analog filter bank to separate range returns. The implementation of the recommended technique is examined.

Dooley, R. P.↗

A Novel Carotid Device for Embolic Diversion: Lessons Learned from a 'First in Man' Trial in Patients with Atrial Fibrillation

Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotid duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison and testing of extended Kalman filters for attitude estimation of the Earth Radiation Budget Satellite

This paper presents the testing and comparison of two extended Kalman filters (EKFs) developed for the Earth Radiation Budget Satellite (ERBS). One EKF updates the attitude quaternion using a four-component additive error quaternion. This technique is compared to that of a second EKF, which uses a multiplicative error quaternion. Brief developments of the algorithms are included. The convergence properties, singularity problems, and normalization techniques of the two filters are addressed. Both filters are tested with simulated ERBS sensor data in addition to real ERBS sensor data. The results of the two filters are also compared to those from the ERBS operational ground support software, which uses a batch differential correction algorithm to estimate attitude and gyro biases.

Bar-Itzhack, Itzhack Y.↗

Comparison and testing of extended Kalman filters for attitude estimation of the Earth radiation budget satellite

The testing and comparison of two Extended Kalman Filters (EKFs) developed for the Earth Radiation Budget Satellite (ERBS) is described. One EKF updates the attitude quaternion using a four component additive error quaternion. This technique is compared to that of a second EKF, which uses a multiplicative error quaternion. A brief development of the multiplicative algorithm is included. The mathematical development of the additive EKF was presented in the 1989 Flight Mechanics/Estimation Theory Symposium along with some preliminary testing results using real spacecraft data. A summary of the additive EKF algorithm is included. The convergence properties, singularity problems, and normalization techniques of the two filters are addressed. Both filters are also compared to those from the ERBS operational ground support software, which uses a batch differential correction algorithm to estimate attitude and gyro biases. Sensitivity studies are performed on the estimation of sensor calibration states. The potential application of the EKF for real time and non-real time ground attitude determination and sensor calibration for future missions such as the Gamma Ray Observatory (GRO) and the Small Explorer Mission (SMEX) is also presented.

Deutschmann, Julie↗

Class of backpropagation techniques for limited-angle reconstruction in microwave tomography

Filtered backpropagation (FBPP) is a well-known technique used in Diffraction Tomography (DT). For accurate reconstruction using FBPP, full 360° angular coverage is necessary. However, it has been shown that using some inherent redundancies in the projection data in a tomographic setup, accurate reconstruction is still possible with 270° coverage which is called the minimal-scan angle range. This can be done by applying weighing functions (or filters) on projection data of the object to eliminate the redundancies and accurately reconstruct the image from 270° coverage. This paper demonstrates procedures to generate many general classes of these weighing filters. These are all equivalent at 270° coverage but vary in performance at lower angular coverages and in presence of noise. This paper does a comparative analysis of different filters when angular coverage is lower than minimal-scan angle of 270°. Simulation studies have been done to find optimum weight filters for sub-minimal angular coverage (<270°)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature profile retrievals with extended Kalman-Bucy filters

The Extended Kalman-Bucy Filter is a powerful technique for estimating non-stationary random parameters in situations where the received signal is a noisy non-linear function of those parameters. A practical causal filter for retrieving atmospheric temperature profiles from radiances observed at a single scan angle by the Scanning Microwave Spectrometer (SCAMS) carried on the Nimbus 6 satellite typically shows approximately a 10-30% reduction in rms error about the mean at almost all levels below 70 mb when compared with a regression inversion.

Ledsham, W. H.↗

Variable threshold zonal filtering

Variable threshold zonal filtering is an active nonlinear image enhancement technique designed to avoid ringing artifacts which filtering can introduce near sharp brightness transitions in the original scene. The filtering procedure can be implemented in the Fourier domain or by subtractive box filtering. It is shown, in reference to a Landsat scene of Iceland, that while conventional box filtering produces severe ringing, zonal filtering results in a more uniform display of local detail.

Schwartz, A. A.↗

Applications of modern estimation techniques to aircraft navigation

Kalman filter design and analysis are discussed, and application of the analysis to multidimensional aircraft navigation problems is considered. The application of perturbation matrices, U-D factors, and filter variance component error source percentages to avionics covariance analysis is suggested. Filter design is divided into four phases, and the procedures applied in each phase are examined.

Bierman, G. J.↗

Ensemble Kalman filter for data assimilation coupled with low-resolution computations techniques applied in fluid dynamics

This paper presents an innovative Reduced-order model (ROM) for merging experimental and simulation data using data assimilation (DA) to estimate the "True" state of a fluid dynamics system, leading to more accurate predictions. Our methodology introduces a novel approach by implementing the ensemble Kalman filter (EnKF) within a reduced-dimensional framework, grounded in a robust theoretical foundation and applied to fluid dynamics. To address the substantial computational demands of DA, the proposed ROM employs low-resolution (LR) techniques to drastically reduce computational costs. This innovative approach involves downsampling datasets for DA computations, followed by an advanced reconstruction technique based on low-cost singular value decomposition (lcSVD). The lcSVD method, a key innovation in this paper, has never been applied to DA before and offers a highly efficient way to enhance resolution with minimal computational resources. Our results demonstrate significant reductions in both computation time and RAM usage through these LR techniques without compromising the accuracy of the estimations. For instance, in a turbulent test case, for a data compression rate of 15.9, the LR approach can achieve a speed-up of 13.7 and a RAM compression of 90.9% while maintaining a low relative root mean square error (RRMSE) of 2.6%, compared to 0.8% in the high-resolution (HR) reference. Furthermore, we highlight the effectiveness of the EnKF in estimating and predicting the state of fluid flow systems based on limited observations and given low-fidelity numerical data. This paper highlights the potential of the proposed DA method in fluid dynamics applications, particularly for improving computational efficiency in CFD and related fields. Its ability to balance accuracy with low computational and memory costs makes it especially suitable for large-scale and real-time applications, such as environmental monitoring or engineering design. This method will be incorporated into ModelFLOWs-app.

Data Assimilation↗

Convergence Analysis for an Online Data-Driven Feedback Control Algorithm

This paper presents convergence analysis of a novel data-driven feedback control algorithm designed for generating online controls based on partial noisy observational data. The algorithm comprises a particle filter-enabled state estimation component, estimating the controlled system’s state via indirect observations, alongside an efficient stochastic maximum principle-type optimal control solver. By integrating weak convergence techniques for the particle filter with convergence analysis for the stochastic maximum principle control solver, we derive a weak convergence result for the optimization procedure in search of optimal data-driven feedback control. Numerical experiments are performed to validate the theoretical findings.

97 MATHEMATICS AND COMPUTING↗

A study of gravity-wave spectra in the troposphere and stratosphere at 5-min to 5-day periods with the Poker Flat MST radar

An analysis of frequency spectra at periods of about 5 days to 5 min from two 20-day sets of velocity measurements in the stratosphere and troposphere region obtained with the Poker Flat mesosphere-stratosphere-troposphere (MST) radar during January and June, 1984 is presented. A technique based on median filtering and averaged order statistics for automatic editing, smoothing and spectral analysis of velocity time series contaminated with spurious data points or outliers is outlined. The validity of this technique and its effects on the inferred spectral index was tested through simulation. Spectra obtained with this technique are discussed. The measured spectral indices show variability with season and height, especially across the tropopause. The discussion briefly outlines the need for obtaining better climatologies of velocity spectra and for the refinements of the existing theories to explain their behavior.

Bemra, R. S.↗

Information-Adaptive Image Encoding and Restoration

The multiscale retinex with color restoration (MSRCR) has shown itself to be a very versatile automatic image enhancement algorithm that simultaneously provides dynamic range compression, color constancy, and color rendition. A number of algorithms exist that provide one or more of these features, but not all. In this paper we compare the performance of the MSRCR with techniques that are widely used for image enhancement. Specifically, we compare the MSRCR with color adjustment methods such as gamma correction and gain/offset application, histogram modification techniques such as histogram equalization and manual histogram adjustment, and other more powerful techniques such as homomorphic filtering and 'burning and dodging'. The comparison is carried out by testing the suite of image enhancement methods on a set of diverse images. We find that though some of these techniques work well for some of these images, only the MSRCR performs universally well oil the test set.

Park, Stephen K.↗

A Comparison of the Multiscale Retinex With Other Image Enhancement Techniques

The multiscale retinex with color restoration (MSRCR) has shown itself to be a very versatile automatic image enhancement algorithm that simultaneously provides dynamic range compression, color constancy, and color rendition. A number of algorithms exist that provide one or more of these features, but not all. In this paper we compare the performance of the MSRCR with techniques that are widely used for image enhancement. Specifically, we compare the MSRCR with color adjustment methods such as gamma correction and gain/offset application, histogram modification techniques such as histogram equalization and manual histogram adjustment, and other more powerful techniques such as homomorphic filtering and 'burning and dodging'. The comparison is carried out by testing the suite of image enhancement methods on a set of diverse images. We find that though some of these techniques work well for some of these images, only the MSRCR performs universally well on the test set.

Rahman, Zia-Ur↗

Application of transmission loss concept in the evaluation of an acoustic filter for liquid-borne transverse resonance modes in a duct of circular cross section

The transmission loss concept is used in the evaluation of an acoustic filter for liquid-borne transverse modes. Tests are conducted to determine the nature of filter element designs required to suppress transverse modes, to verify the presence of transverse modes in the test assembly, to define the acoustic wave incident, and to establish data recording, processing and analysis techniques providing transmission wave filter data. The first, second, and third tangential modes, and the first radial mode are found at frequencies of 2150, 3330, 4420, and 4110 Hz, respectively, and peaks of the tangential modes recede while the radial mode peak remains, demonstrating agreement with theoretical nodal patterns. The present design is found applicable to a liquid-oxygen system, and allows the easy-to-fabricate filter to fit within the available space envelope.

Iwanicki, L. R.↗

Adaptive filtering of radar images for autofocus applications

Autofocus techniques are being designed at the Jet Propulsion Laboratory to automatically choose the filter parameters (i.e., the focus) for the digital synthetic aperture radar correlator; currently, processing relies upon interaction with a human operator who uses his subjective assessment of the quality of the processed SAR data. Algorithms were devised applying image cross-correlation to aid in the choice of filter parameters, but this method also has its drawbacks in that the cross-correlation result may not be readily interpretable. Enhanced performance of the cross-correlation techniques of JPL was hypothesized given that the images to be cross-correlated were first filtered to improve the signal-to-noise ratio for the pair of scenes. The results of experiments are described and images are shown.

Stiles, J. A.↗

An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements

Purpose: Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors propose an angle-dependent estimation technique, where the incident spectra across a wide range of angular trajectories can be estimated accurately with only a single phantom and a single axial scan in the absence of the knowledge of the bowtie filter. Methods: The proposed technique uses a uniform cylindrical phantom, made of ultra-high-molecular-weight polyethylene and positioned in an off-centered geometry. The projection data acquired with an axial scan have a twofold purpose. First, they serve as a reflection of the transmission measurements across different angular trajectories. Second, they are used to reconstruct the cross sectional image of the phantom, which is then utilized to compute the intersection length of each transmission measurement. With each CT detector element recording a range of transmission measurements for a single angular trajectory, the spectrum is estimated for that trajectory. A data conditioning procedure is used to combine information from hundreds of collected transmission measurements to accelerate the estimation speed, to reduce noise, and to improve estimation stability. The proposed spectral estimation technique was validated experimentally using a clinical scanner (Somatom Definition Flash, Siemens Healthcare, Germany) with spectra provided by the manufacturer serving as the comparison standard. Results obtained with the proposed technique were compared against those obtained from a second conventional transmission measurement technique with two materials (i.e., Cu and Al). After validation, the proposed technique was applied to measure spectra from the clinical system across a range of angular trajectories [−15°, 15°] and spectrum settings (80, 100, 120, 140 kVp). Results: At 140 kVp, the proposed technique was comparable to the conventional technique in terms of the mean energy difference (MED, −0.29 keV) and the normalized root mean square difference (NRMSD, 0.84%) from the comparison standard compared to 0.64 keV and 1.56%, respectively, with the conventional technique. The average absolute MEDs and NRMSDs across kVp settings and angular trajectories were less than 0.61 keV and 3.41%, respectively, which indicates a high level of estimation accuracy and stability. Conclusions: An angle-dependent estimation technique of CT x-ray spectra from rotational transmission measurements was proposed. Compared with the conventional technique, the proposed method simplifies the measurement procedures and enables incident spectral estimation for a wide range of angular trajectories. The proposed technique is suitable for rigorous research objectives as well as routine clinical quality control procedures.

61 RADIATION PROTECTION AND DOSIMETRY↗