Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

High-response on-line gas analysis system for hydrogen-reaction combustion products

The results of testing an on-line quadrupole gas analyzer system are reported. Gas samples were drawn from the exhaust of a hydrogen-oxygen-nitrogen rocket which simulated the flow composition and dynamics at the combustor exit of a supersonic combustion ramjet engine. System response time of less than 50 milliseconds was demonstrated, with analytical accuracy estimated to be + or - 5 percent. For more complex chemical systems with interfering atom patterns, analysis would be more difficult. A cooled-gas pyrometer probe was evaluated as a total temperature indicator and as the primary mass flow measuring element for the total sample flow rate.

Metzler, A. J.↗

Handbook of Recommended Practices for the Determination of Liquid Monopropellant Rocket Engine Performance

The design, installation, and operation of systems to be used for directly measuring quantities of fundamental importance to the determination of monopropellant thruster performance is described. Areas covered include: (1) force and impulse measurement; (2) propellant mass usage and flow measurement; (3) pressure measurement; (4) temperature measurement; (5) exhaust gas composition measurement; and (6) data reduction and performance determination.

R A Bjorklund↗

On the skewness of the temperature derivative in turbulent flows

An attempt is made to explain the fact that, contrary to the requirements of local isotropy, the skewness of the streamwise temperature derivative has been observed to be a nonzero constant of magnitude of about unity in high-Reynolds-number and high-Peclet-number turbulent shear flows. Measurements in slightly heated homogeneous shear flows and in unsheared grid turbulence suggest that the skewness is nonzero only when the mean shear and the mean temperature gradient are both nonzero.

Sreenivasan, K. R.↗

Stability and transition of three-dimensional flows

The role of secondary instabilities in the transition to turbulence in three-dimensional boundary layers (especially in swept-wing flows) is characterized, reviewing the results of recent theoretical and experimental investigations. Consideration is given to cross-flow vortices, boundary-layer profile measurements, flow visualization, spanwise wavelength determinations, interactions, problems involving rotating disks and cones, and leading-edge contamination. All of the flows investigated are shown to exhibit streamwise vorticity and to depend strongly on initial conditions.

Reed, H. L.↗

Heat Flux Sensor

A heat flux microsensor developed under a NASP Small Business Innovation Research (SBIR) has a wide range of potential commercial applications. Vatell Corporation originally designed microsensors for use in very high temperatures. The company then used the technology to develop heat flux sensors to measure the rate of heat energy flowing in and out of a surface as well as readings on the surface temperature. Additional major advantages include response to heat flux in less than 10 microseconds and the ability to withstand temperatures up to 1,200 degrees centigrade. Commercial applications are used in high speed aerodynamics, supersonic combustion, blade cooling, and mass flow measurements, etc.

Source record↗

A VOI Web Application for Distinct Geothermal Domains: Statistical Evaluation of Different Data Types within the Great Basin

The Great Basin region contains different domains that have different structural and hydrothermal flow patterns. Depending on the characteristics of these patterns, certain data types may be more successful at detecting hidden geothermal resources. In this paper, we quantitatively evaluate if certain data types are more successful in certain domains. Given different aquifer, strain and structural conditions, we explore which data types statistically reveal positively labeled geothermal sites. We utilize value of information (VOI) metrics to help quantify the reliability of data types to discriminate against "positive" and "negative" labeled geothermal sites. We also evaluate how kernel density estimation can help generalize the statistics that inform VOI, which is necessary given the limited data in geothermal exploration. Except for the Carbonate Aquifer, the highest ranking of the Vimperfect is the Local Structural Setting. Next, the slip and dilation tendency is first for Carbonate Aquifer and second for Central Nevada Seismic Belt and Western Great Basin. For the Carbonate Aquifer, heat flow is has the lowest Vimperfect value compared to the other three domains, which is consistent with the understanding of how heat flow measurements are masked by regional groundwater flow.

Bayesian analysis↗

Sap flow data from San Lorenzo, Panama (PA-SLZ), 2019

This data package contains sap flow data from the NGEE Tropics site in San Lorenzo, Panama (PA-SLZ) from 22 January 2019 to 31 December 2019. Sap flow measurements quantify plant-level transpiration, which varies across spatial and temporal scales. It is a key trait in understanding plant hydraulic functioning. Here sap flow was measured using ‘Granier-type’ thermal dissipation probes. Raw data downloaded from each data logger are in the 'Raw data' folder as CSV files, along with the Campbell data logger programs which can be read when opened with a text editor. The data was processed using the AquaFlux package in R. R code for preparing the data for use in AquaFlux is in the 'R code for pre-processing data folder'; it is saved as a text file that can be copy and pasted into R. The processed data for each data logger is in the 'Processed data' folder as CSV files. Documentation for the Granier sensors and AquaFlux package is in the ‘Manuals’ folder as PDF files.

54 ENVIRONMENTAL SCIENCES↗

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aerodynamic and Acoustic Performance of Two Choked-Flow Inlets Under Static Conditions

Tests were conducted to determine the aerodynamic and acoustic performance of two choking flow inlets under static conditions. One inlet choked the flow in the cowl throat by an axial translation of the inlet centerbody. The other inlet employed a translating grid of airfoils to choke the flow. Both inlets were sized to fit a 13.97 cm diameter fan with a design weight flow of 2.49 kg/sec. The inlets were operated in both the choked and unchoked modes over a range of weight flows. Measurements were made of inlet pressure recovery, flow distortion, surface static pressure distribution, and fan noise suppression. Choking of the translating centerbody inlet reduced blade passing frequency noise by 29 db while yielding a total pressure recovery of 0.985. Noise reductions were also measured at 1/3-octave band center frequencies of 2500, 5000, and 20,000 cycles. The translating grid inlet gave a total pressure recovery of 0.968 when operating close to the choking weight flow. However, an intermittent high intensity noise source was encountered with this inlet that precluded an accurate measurement of inlet noise suppression.

Miller, B. A.↗

Unsteady wing surface pressures in the wake of a propeller

The unsteady nature of the propeller slipstream interacting with a wing has been studied by flow visualization and unsteady wing surface pressure measurements. Flow visualization was performed by marking the propeller tip vortex with smoke. Unsteady wing surface pressures were measured by traversing a wing instrumented with a chordwise array of 16 microphones in a spanwise direction through the propeller wake. This work yielded information on the motion of the propeller wake as it passes over the wing. As the propeller wake passed over the wing: the propeller tip vortex experienced an inviscid interaction at the leading edge; viscous action at the leading edge severed the propeller tip vortex; the propeller tip vortex experienced significant spanwise and chordwise displacements and then deformed in order to reconnect at the trailing edge; axial velocity in the vortex core caused the helical vortex to thicken or stretch near the wing surface; and, the magnitude of the pressure fluctuations decreased in magnitude with distance traveled along the chord.

Johnston, R. T.↗

Summary Report: Development of a New ASTM Standard Test Method for Phase Change Materials

An ASTM International task group was formed with representatives from research organizations, PCM and insulation manufacturers, testing laboratories, etc., to develop an ASTM standard test method, using a heat flow meter apparatus (HFMA), to make heat-flow measurements under prescribed dynamic, or non steady-state, conditions. The HFMA is typically used for measuring steady-state thermal transmission properties of materials, following ASTM C518. The new ‘dynamic’ test method is based on a modification of the C518 test method, for measuring volumetric specific heat of regular (i.e. with no PCM) thermal insulation materials. The proposed test method describes the methodology for using a HFMA for measuring thermal storage properties of phase change materials and products. It requires the measurement of non-steady-state heat flow into or out of a flat slab specimen to determine the stored energy (i.e. enthalpy) change as a function of temperature. In particular, this test method is intended to measure the sensible and latent heat storage capacity of products incorporating phase-change materials (PCM). The thermal storage capacity of a PCM is well defined via four parameters: specific heats of both solid and liquid phases, phase change temperature(s) and phase change enthalpy. This report provides brief summaries of the proposed standard test method and the standard development related activities at Oak Ridge National Laboratory (ORNL) during fiscal year 2013 (FY13). The draft standard document is also provided as an appendix.

dynamic testing↗

A Separation Control CFD Validation Test Case: Baseline and Steady Suction - Part 1

Low speed flow separation over a wall-mounted hump, and its control using steady suction, were studied experimentally in order to generate a data set for a workshop aimed at validating CFD turbulence models. The baseline and controlled data sets comprised static and dynamic surface pressure measurements, flow field measurements using Particle Image Velocimetry (PIV) and wall shear stress obtained via oil-film interferometry. In addition to the specific test cases studied, surface pressures for a wide variety of conditions were reported for different Reynolds numbers and suction rates. Stereoscopic PIV and oil-film flow visualization indicated that the baseline separated flow field was mainly two- dimensional. With the application of control, some three-dimensionality was evident in the spanwise variation of pressure recovery, reattachment location and spanwise pressure fluctuations. Part 2 of this paper, under preparation for the AIAA Meeting in Reno 2005, considers separation control by means of zero-efflux oscillatory blowing.

David Greenblatt↗

A Separation Control CFD Validation Test Case: Baseline and Steady Suction - Part 1

Low speed flow separation over a wall-mounted hump, and its control using steady suction, were studied experimentally in order to generate a data set for a workshop aimed at validating CFD turbulence models. The baseline and controlled data sets comprised static and dynamic surface pressure measurements, flow field measurements using Particle Image Velocimetry (PIV) and wall shear stress obtained via oil-film interferometry. In addition to the specific test cases studied, surface pressures for a wide variety of conditions were reported for different Reynolds numbers and suction rates. Stereoscopic PIV and oil-film flow visualization indicated that the baseline separated flow field was mainly two-dimensional. With the application of control, some three-dimensionality was evident in the spanwise variation of pressure recovery, reattachment location and spanwise pressure fluctuations. Part 2 of this paper, under preparation for the AIAA Meeting in Reno 2005, considers separation control by means of zero-efflux oscillatory blowing.

Greenblatt, David↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

An experimental study of entrainment and transport in the turbulent near wake of a circular cylinder

Attention is given to an experimental investigation of transport processes in the near wake of a circular cylinder, for a Reynolds number of 140,000, in which an X-array of hot wire probes mounted on a pair of whirling arms was used for flow measurement. Rotation of the arms in a uniform flow applies a wide range of relative flow angles to these X-arrays, making them inherently self-calibrating in pitch. A phase signal synchronized with the vortex-shedding process allowed a sorting of the velocity data into 16 populations, each having essentially constant phase. An ensemble average for each population yielded a sequence of pictures of the instantaneous mean flow field in which the vortices are frozen, as they would be on a photograph. The measurements also yield nonsteady mean data for velocity, intermittency, vorticity, stress, and turbulent energy production, as a function of phase. Emphasis is given in a discussion of study results to the nonsteady mean flow, which emerges as a pattern of centers and saddles in a frame of reference that moves with the eddies. The kinematics of the vortex formation process are described in terms of the formation and evolution of saddle points between vortices in the first few diameters of the near wake.

Cantwell, B.↗

Standard test case for a low-speed, turbulent junction vortex flow

The mean flow structure upstream, around within, and in the near wake of a turbulent junction or horseshoe vortex is reported for an incompressible subsonic flow. Measurements of the primitive variables of velocity and pressure are reported on all surfaces bounding the region of the vortex flow and on three transverse and one streamwise plane within the flowfield itself for comparisons between the measured and any calculated flow variables. Detailed surface flow visualizations and some direct force measurements of surface shear stress are also available. The data is a highly detailed, coherent, self-consistent set offered to the computational fluid mechanics community as a standard test case for the evaluation of the capability of numerical solvers intended for predicting the flowfield in such a complex, separated, three-dimensional turbulent flow. This data base is available for copying to user supplied tapes or for transmission via BITNET, as well as in two National Technical Information Service (NTIS) reports.

Pierce, F. J.↗