Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments & Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Virtual Framework for Science Federations with Instruments Access and Control

Experimental science workflows require federations of geographically dispersed science instruments and computing systems connected over a wide-area network. We develop a Virtual Infrastructure Twin (VIT) framework, which is a digital twin of the physical infrastructure that utilizes network virtualization and containerization technologies to support the development and testing of science workflow codes. Using VIT, we illustrate the access to instruments via EPICS system and the orchestration of containerized computations across federation computing systems. We also present a machine learning method to convert VIT throughput measurements to closely match the corresponding physical testbed measurements.

Rao, Nageswara↗

Laboratory Measurements of Instrumental Signatures of the LSST Camera Focal Plane

Electro-optical testing and characterization of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Camera focal plane, consisting of 205 charge-coupled devices (CCDs) arranged into 21 stand-alone Raft Tower Modules (RTMs) and 4 Corner Raft Tower Modules (CRTMs), is currently being performed at the SLAC National Accelerator Laboratory. Testing of the camera sensors is performed using a set of custom-built optical projectors, designed to illuminate the full focal plane or specific regions of the focal plane with a series of light illumination patterns: the crosstalk projector, the flat illuminator projector, and the spot grid projector. In addition to measurements of crosstalk, linearity and full well, the ability to project realistically-sized sources, using the spot grid projector, makes possible unique measurements of instrumental signatures such as deferred charge distortions, astrometric shifts due to sensor effects, and the brighter-fatter effect, prior to camera first light. Here we present the optical projector designs and usage, the electro-optical measurements and how these results have been used in testing and improving the LSST Camera instrumental signature removal algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding Material Damage and Degradation through Thermal Property Instruments

Quantifying material damage and degradation under reactor conditions enables researchers to make important predictions regarding reactor safety and efficiency. More specifically, thermal property instruments serve as a powerful tool in quantifying the evolution of thermal properties under irradiation, and hence, are necessary in qualifying fuels and materials for reactor use. In addition to providing insight into thermal properties, some instruments may provide a new means of quantifying radiation damage, a challenge in modern nuclear materials research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Instrumentation Wish List for High Power/High Brightness ERLS

The advent of the energy recovering linac (ERL) brings with it the promise of linac-quality beams generated with near storage ring efficiency. This potential will not, however, be fulfilled without overcoming a number of technical and operational challenges. We will review the basics of ERL dynamics and operation, and give examples of idiosyncratic ERL behavior and requirements posing particular challenges from the perspective of diagnostics and instrumentation. Beam performance parameters anticipated in next-generation ERLs will be discussed, and a ?wish list? for the instrumentation of these machines presented.

Douglas, David↗

Derisking Renewable Energy Investment. A Framework to Support Policymakers in Selecting Public Instruments to Promote Renewable Energy Investment in Developing Countries

This report introduces an innovative framework to assist policymakers to quantitatively compare the impact of different public instruments to promote renewable energy. The report identifies the need to reduce the high financing costs for renewable energy in developing countries as an important task for policymakers acting today. The framework is structured in four stages: (i) risk environment, (ii) public instruments, (iii) levelised cost and (iv) evaluation. To illustrate how the framework can support decision-making in practice, the report presents findings from illustrative case studies in four developing countries. It then draws on these results to discuss possible directions for enhancing public interventions to scale-up renewable energy investment. UNDP is also releasing a financial tool for policymakers to accompany the framework. The financial tool is available for download on the UNDP website.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of TRIGA-based experimental device for fiber optics in-core instrumentation testing for VHTRs

Given the harsh environments of high temperature reactors, new in-core instrumentation has to be developed, since existing approaches may fail prematurely in VHTRs. The paper discusses ongoing efforts to support progress of suitable advanced in-core instrumentation technologies and develop an experimental approach for evaluation of their performance within VHTRs via emulation of VHTR in-core conditions in TRIGA reactors. Successful completion of the presented computational analysis concludes the first phase of the project. As demonstrated, it is proposed to use a high temperature furnace with fluence equivalency in operating TRIGA reactors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An evaluation of nearest neighbor averaging's improvements to the measurement sensitivity of wide-area radiological scanning instruments - 15560

Through the Sandia National Laboratories (SNL) New Mexico Small Business Assistance (NMSBA) program, Sandia worked with the Environmental Restoration Group (ERG) Inc. to verify and validate a novel algorithm used to determine the scanning Critical Level (Lc) and Minimum Detectable Concentration (MDC) (or Minimum Detectable Areal Activity) for the 102F scanning system. Through the use of Monte Carlo statistical simulations the algorithm mathematically demonstrates accuracy in determining the Lc and MDC when a nearest-neighbor averaging (NNA) technique was used. To empirically validate this approach, SNL prepared several spiked sources and ran a test with the ERG 102F instrument on a bare concrete floor known to have no radiological contamination other than background naturally occurring radioactive material (NORM). The tests conclude that the NNA technique increases the sensitivity (decreases the Lc and MDC) for high-density data maps that are obtained by scanning radiological survey instruments. It is further described in Sandia Laboratories document number SAND2014-16522. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

APR1400 In-Core Instrumentation Penetration Failure by Zirconia Melt

Light water reactors have many penetrations at the reactor vessel lower head which are called ICI (in-core instrumentation tubes), ICM-GT (in-core monitoring guide tubes), CRGT (control rod guide tubes) and drain tubes. For Korean PWRs (pressurized water reactors), there are dozens of bottom-up type ICI penetration tubes (45 for OPR1000 and 61 for APR1400). For the typical BWRs (boiling water reactors), hundreds of penetrations are positioned at the reactor vessel lower head due to the structural complexity at the reactor upper head. These penetrations are regarded as the most vulnerable structures during a severe accident as they could be failed by high temperature of melt (or debris) and its decay heat. That is, tube rupture and/or tube ejection could occur because there exist an empty hole inside the penetration tube which can be a melt flow path, and they are attached to the inside of the reactor vessel by a partial weld with a gap between the tubes and reactor vessel. Therefore, the research on the penetration failure is of importance, as it could lead to melt discharge into the containment and subsequent release of radioactive materials to the environment due to the containment failure. This paper focuses on the experimental investigation on the tube ejection failure for the APR1400 ICI penetration. The tube ejection experiments were performed as it was exposed to high temperature of zirconia melt and high pressure. The tube ejection failure experiments were performed for the APR1400 in-core instrumentation penetration nozzle. Zirconia melt was used as a simulant of molten corium and interacted with the penetration specimen. The specimen was pressurized up to 2.6 bar during the interaction with melt to induce the tube ejection. The penetration weld was heated up to its melting temperature, and the penetration tube and weld above the reactor vessel surface were eroded severely by the melt. However, even though it was estimated that the weld failure occurred and the reactor vessel with stainless steel cladding was ablated severely by the melt, the tube ejection did not take place, and consequently the integrity for the APR1400 ICI penetration was confirmed in the present experimental conditions. The goal of this research is to improve the penetrations failure models in MAAP5 codes based on the experimental data. To achieve this goal, it is necessary to increase the heat flux and pressure acting on the penetration tube to find the conditions for the tube ejection failure. Moreover, the penetration failure experiments will be performed by delivering melt into the penetration specimen to simulate the melt relocation process in a real severe accident situation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Instrumentation Development for Transient Testing in TREAT

Development of nuclear fuels requires experimentation and modeling for behavior during transient power and cooling conditions. The Transient Reactor Test facility (TREAT) will provide unique capability in the U.S. to perform controlled experimentation of such conditions in a nuclear environment. To support experiment objectives and provide validation data for modeling and simulation tools, experiment instrumentation plays a critical role in monitoring test specimen behavior (temperature, dimensional changes, relocation, microstructural evolution, etc.) and specimen boundary conditions (thermal, mechanical, nuclear) at various length and time scales with the ultimate goal of reducing uncertainties in experiment conditions. This summary presents an overview of current instrument development objectives and progress for TREAT experiments with emphasis on near-term activities to support Reactivity Initiated Accident (RIA) experiments in LWR systems. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rethinking Coherent Diffraction Instruments for High Brightness Sources

Over the past two decades, exceptional progress has been made providing coherent x-ray beams at both high-brightness synchrotron sources and x-ray free electron lasers (XFEL). The availability of these coherent x-rays has led to a surge in instruments that exploit x-ray coherence for either x-ray photon correlation spectroscopy (XPCS) or coherent diffraction imaging (CDI). A key to these techniques has been to resolve, or at least nearly resolve, the speckles associated with the scattering from structural disorder. Given practical limits on detector pixel size, this requires long sample-to-detector distances. This paper presents numerical simulations of an instrument that can efMiciently provide a long sample-detector distance while maintaining the ability to rapidly set momentum transfer by inserting crystals with different order in the incident beam, thus changing in incident direction instead of moving the detector.

Fuoss, Paul H↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Remote Instrumentation and Data Acquisition: An Internship Research Report

This report outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope’s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and lessons learned, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Fermilab]↗

Beam instrumentation for future high intense hadron accelerators at Fermilab

High intensity hadron beams of up to 2 MW beam power are a key element of new proposed experimental facilities at Fermilab. Project X, which includes a SCRF 8 GeV H{sup -} linac, will be the centerpiece of future HEP activities in the neutrino sector. After a short overview of this, and other proposed projects, we present the current status of the beam instrumentation activities at Fermilab with a few examples. With upgrades and improvements they can meet the requirements of the new beam facilities, however design and development of new instruments is needed, as shown by the prototype and conceptual examples in the last section.

43 PARTICLE ACCELERATORS↗

The DARHTAcquisition, Archival, Analysis, And Instrument Control System (DAAAC), And Network Infrastructure

The Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) at Los Alamos National Laboratory is the world's most advanced weapons test facility. DARHT contains two linear accelerators for producing flash radiographs of hydrodynamic experiments. High-speed electronics and optical instrumentation are used for triggering the accelerators and collecting accelerator data. Efficient and effective diagnostics provide basic information needed to routinely tune the accelerators for peak radiographic performance, and to successfully monitor the accelerators performance. DARHT's server and network infrastructure is a key element in providing shot related data storage and retrieval for successfully executing radiographic experiments. This paper will outline the elaborate Data Acquisition, Archival, Analysis, and Instrument Control System (DAAAC), as well as the server and network infrastructure for both accelerators.

43 PARTICLE ACCELERATORS↗

Instrumentation and Quench Protection for LARP Nb3Sn Magnets

The US LHC Accelerator Research Program (LARP) is developing Nb{sub 3}Sn prototype quadrupoles for the LHC interaction region upgrades. Several magnets have been tested within this program and understanding of their behavior and performance is a primary goal. The instrumentation is consequently a key consideration, as is protection of the magnet during quenches. In all LARP magnets, the flexible circuits traces combine the instrumentation and the protection heaters. Their fabrication relies on printed circuit technology based on a laminate made of a 45-micron thick kapton sheet and a 25-micron thick foil of stainless steel. This paper reviews the protection heaters designs used in the TQ (Technology Quadrupole) and LR (Long Racetrack) series as well as the one used in LBNL HD2a high field dipole and presents the design of the traces for the Long Quadrupole (LQ), addressing challenges associated with the stored energy and the length of the magnet.

43 PARTICLE ACCELERATORS↗

Evaluation of the Pressing Characteristics of Commercially Pure Titanium Using an Instrumented Double Acting Die

With recent advances in synthesizing titanium powder by low-cost routes, there has been growing interest in identifying process/material conditions that overcome the powder compaction problems typically found with this reactive metal. The use of instrumented dies in studying the cold pressing process for commercial iron and steel powders has provided greater insight into the complex phenomena that occur and may be used to evaluate constitutive relations that describe the compaction process. Nevertheless, little work has been conducted on the special, more problematic case of reactive metal powders such as titanium. An instrumented die was developed that allows die wall friction to be characterized and the radial stress distribution along the die wall and throughout the compact to be monitored. As will be presented, this tool has been used to investigate titanium compaction and to draw comparisons with results obtained on a baseline commercial iron powder. Both sets of data were systematically collected using various powder/die lubrication combinations.

36 MATERIALS SCIENCE↗

A tabletop X-ray tomography instrument for nanometer-scale imaging: reconstructions

Abstract We show three-dimensional reconstructions of a region of an integrated circuit from a 130 nm copper process. The reconstructions employ x-ray computed tomography, measured with a new and innovative high-magnification x-ray microscope. The instrument uses a focused electron beam to generate x-rays in a 100 nm spot and energy-resolving x-ray detectors that minimize backgrounds and hold promise for the identification of materials within the sample. The x-ray generation target, a layer of platinum, is fabricated on the circuit wafer itself. A region of interest is imaged from a limited range of angles and without physically removing the region from the larger circuit. The reconstruction is consistent with the circuit’s design file.

47 OTHER INSTRUMENTATION↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗