Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Initial Calibration of Large Timing Arrays for the LHC

In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

In-situ High-energy X-ray Diffraction Study of the Local Structure of Supercooled Liquid Si

While changes in the coordination number for liquid silicon upon supercooling, signaling an underlying liquid-liquid phase transition, have been predicted, x-ray and neutron measurements have produced conflicting reports. In particular some studies have found an increase in the first shell coordination as temperature decreases in the supercooled regime, while others have reported increases in the coordination number with decreasing temperature. Employing the technique of electrostatic levitation coupled with high energy x-ray diffraction (125 keV), and rapid data acquisition (100ms collection times) using an area detector, we have obtained high quality structural data more deeply into the supercooled regime than has been possible before. No change in coordination number is observed in this temperature region, calling into question previous experimental claims of structural evidence for the existence of a liquid-liquid phase transition.

Lee, G. W.↗

Advanced methods for preparation and characterization of infrared detector materials

Crystal growth of Hg sub 1-x Cd sub x Te and density measurements of ingot slices are discussed. Radial compositional variations are evaluated from the results of infrared transmission edge mapping. The pseudo-binary HgTe-CdTe phase diagram is examined with reference to differential thermal analysis measurements. The phase equilibria calculations, based on the 'regular association solution' theory (R.A.S.) are explained and, using the obtained R.A.S. parameters, the activities of Hg, Cd, and Te vapors and their partial pressures over the pseudo-binary melt are calculated.

Lehoczy, S. L.↗

Status of ICARUS NUMI Interaction Cross-Section Analysis

The ICARUS experiment, utilizing Liquid Argon Time Projection Chamber (LAr TPC) technology, has been installed at Fermilab in Chicago, Illinois, following its initial operation in Italy and subsequent refurbishment at CERN. ICARUS completed commissioning in June 2022. Currently, the experiment is in the phase of analyzing data from its two runs of physics data acquisition and gearing up for the third run. While its primary objective is to function as the far detector of the Short Baseline Neutrino program (SBN), seeking sterile neutrino signatures, ICARUS also offers diverse physics capabilities, including searches beyond the standard model and measurements of cross-sections. In addition to being exposed to the common Booster Neutrino (BNB) beamline, ICARUS also receives off-axis neutrinos from the Main Injector (NuMI) beam. Due to the off-axis angle between NuMI and ICARUS, coupled with contributions from both pion and kaon decays to neutrino fluxes, interactions of NuMI neutrinos within ICARUS can be detected over a range of several GeV in energy. These interactions present opportunities for crucial cross-section measurements and model tests within an energy range that overlaps both the SBN oscillation search and a portion of the DUNE spectrum. This poster presentation will delve into our efforts to conduct a muon-neutrino cross-section measurement, where the signal is defined by events with no pions produced in the final state of the interaction, along with some preliminary muon-neutrino inclusive measurements. Additionally, it will provide updates on the current status and future plans, including reconstruction, selection, and analysis procedures.

43 PARTICLE ACCELERATORS↗

Bayesian Fit for the NOvA Three Flavor Oscillation Analysis

NOvA is a long baseline neutrino oscillation experiment, using Fermilab's NuMI beam and a functionally identical near and far detector. NOvA measures muon neutrino disappearance and electron neutrino appearance to probe neutrino oscillation parameters, including the large neutrino mixing angle, the mass ordering, and the CP-violating phase. NOvA has developed a Bayesian analysis in addition to its Frequentist analysis, using Markov Chain Monte Carlo. This Bayesian framework allows for measurements previously difficult to make with the Frequentist framework, such as the Jarlskog invariant and the reactor mixing angle. The details and status of the Bayesian Framework will be presented, as well as latest NOvA results on measurements of three-flavor oscillation parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radial diffusion of Io-injected plasma

The paper reexamines the problem of particle injection by Io and subsequent radial diffusion by flux tube interchange using a proper phase space density formulation. The mathematical formalism is developed, and the theoretical results are compared with the observations, taking into account the pitch angle and energy coverage of the detector on Pioneer 10. Two objectives are pursued: (1) to test the hypothesis of Siscoe and Chen (1977) that Io is the source for all of the plasma observed by Frank et al. (1976) inside 10 R(J); and (2) to describe a simple but flexible method intended to analyze the observations of any other plasma instrument flown through the inner Jovian magnetosphere, e.g., those on Voyager 1 and 2 and Galileo.

Goertz, C. K.↗

Capsulation Satellite or CapSat: A Low-Cost, Reliable, Rapid-Response Spacecraft Platform

The National Aeronautics and Space Administration (NASA) Goddard's Rideshare Office estimates that between 2013 and 2022, NASA launches of primary satellites will have left unused more than 20,371 kilograms of excess capacity. This equates to hundreds of millions of dollars in launch-vehicle costs going unutilized. To fill this void with a standard CubeSat or SmallSat spacecraft platform, which when required to be more reliable, still will cost in the neighborhood of $1M a kilogram, making it prohibitively expensive. A newly proposed solution, which NASA is pursuing, is called the Capsulation Satellite or CapSat. CapSat is a modularized, pressurized, thermally controlled spacecraft designed to host ruggedized commercially available instrumentation in a terrestrial like environment on orbit. Using a technique that is under review for a patent, CapSat actively manages internal air temperatures in a manner similar to a household thermostat. This gives CapSat high-thermal stability, which, in turn, provides component longevity. CapSat was specifically designed to take advantage of the United States Air Force (USAF) Rideshare Program and the Evolved Expendable Launch Vehicle Secondary Payload Adaptor, or ESPA ring. The ESPA ring comes in two sizes: standard and Grande. CapSat primarily will take advantage of the ESPA Grande to provide a 300-kilogram payload capability per attachment point, with up to four attachment points per ring. This approach combines a high-mass capability with a proven Rideshare mechanical interface and secondary payload management infrastructure. Opportunities for ESPA based co-manifests are continuing to expand. The CapSat program is currently funded to design and build a limited prototype and perform thermal-vacuum testing. CapSat is currently in the concept/study phase for both single missions and constellation of earth- and space-observing missions. One of these studies includes land imaging using state-of-the-art advanced infrared detector technology. This paper will report on the current status of the CapSat hardware design, testing, and results as well as any openly available advanced concept study results. The CapSat solution is intended to be a game-changing paradigm shift. CapSat will repurpose currently available, already-proven technology to reduce spaceflight hardware costs to less than $50,000 per kilogram.

Burt, Joe↗

Measuring glass abundances in lunar agglutinates

The purpose of this study is to develop a standard method for measuring modal abundances of glass in single agglutinates in the lunar regolith. Not only does agglutinitic glass increase in single agglutinates as clasts of older agglutinates get incorporated into newer agglutinates with increasing maturity, but it is in this glassy phase that nanophase superparamagnetic Fe metal originates as a result of reduction reactions during the agglutination process. We report the results of two sets of independent measurements using two different methods to determine the proportion of glass in single agglutinates. We have used polished grain mounts (PGM) of five hand-picked single agglutinates from Apollo 16 soil 61181. The ISI Scanning Electron Microscope (SEM) fitted with a high-resolution Backscattered Electron (BSE) detector was used to collect high-contrast BSE images of the agglutinates. Several images were collected to represent each single agglutinate. The contrast, brightness, and focus were adjusted to optimize each image collected. Histograms of the grayscale range for all images produced four 'peaks' corresponding to epoxy, glass, crystalline phases, and metal grains. We analyzed every grid point for 12 elements with a less than 1 micron electron beam using a CAMECA SX-50 electron probe microanalyzer (EPM). If any analysis was not within about 10% of the stoichiometry of a known lunar mineral, we considered that point to be nonmineralic. Our results show that there is a remarkable correspondence in the glass percentages obtained by the two methods. The EPM method may overestimate glass because secondary fluorescence from dusty clasts in agglutinitic glass can give the appearance of nonmineralic targets. The BSE method may underestimate glass because the diversity of compositions of agglutinitic glass may not be contained under one grayscale 'peak' during image analysis.

Strait, M. M.↗

The Deep Underground Neutrino Experiment (DUNE) Program

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment aimed at determining the neutrino mass hierarchy and the CP-violating phase. The DUNE physics program also includes the detection of astrophysical neutrinos and the search for signatures beyond the Standard Model, such as nucleon decays. DUNE consists of a near detector complex located at Fermilab and four 17 kton Liquid Argon Time Projection Chamber (LArTPC) far detector modules to be built 1.5 km underground at SURF, approximately 1300 km away. The detectors are exposed to a wideband neutrino beam generated by a 1.2 MW proton beam with a planned upgrade to $>$ 2 MW. Two 770 ton LArTPCs (ProtoDUNEs) have been operated at CERN for over 2 years as a testbed for DUNE far detectors and have been optimized to take new cosmic and test-beam data in 2024-2025. The DUNE and ProtoDUNE experiments and physics goals, as well as recent progress and results, are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performing spectroscopic and specific heat studies of improper ferroelectrics

The results of infrared measurements on Ni-Br, Cu-Cl, and Fe-I boracite improper ferroelectrics and far infrared measurements of Ni-Br boracite are presented. The boracites have the general formula X3B7O3Y, where X = divalent metal and Y = halogen. They undergo a first order phase transition from a high temperature paraelectric phase with cubic symmetry to a ferroelectric phase with orthorhombic symmetry. The boracites are "improper ferroelectrics" since the spontaneous polarization is not the primary order parameter in the cubic-orthorhombic phase transition. Current understanding of these materials is that the primary order parameter is associated with a doubly degenerate zone-boundary phonon in the cubic phase. The degenerate critical modes become homogeneous and split into the A sub 1 and A sub 2 modes in the orthorhombic phase, doubling the volume of the primitive cell. An harmonic coupling between the softing A sub 1 and a low frequency A sub 1 optic mode induces a spontaneous polarization as a secondary effect in the ferroelectric phase. This secondary non-critical nature of the ferroelectric mode earns these materials the "improper" title and is responsible for their unique properties and high figure of merit in detector use.

Coleman, L. B.↗

JSC Stardust Curation Team

STARDUST, a NASA Discovery-class mission, is the first to return samples from a comet. Grains from comet Wild 2's coma-the gas and dust envelope that surrounds the nucleus-will be collected as well as interstellar dust. The mission which launched on February 7, 1999 will encounter the comet on January 10, 2004. As the spacecraft passes through the coma, a tray of silica aerogel will be exposed, and coma grains will impact there and become captured. Following the collection, the aerogel tray is closed for return to Earth in 2006. A dust impact mass spectrometer on board the STARDUST spacecraft will be used to gather spectra. of dust during the entire mission, including the coma passage. This instrument will be the best chance to obtain data on volatile grains, which will not be well-collected in the aerogel. The dust impact mass spectrometer will also be used to study the composition of interstellar grains. In the past 5 years, analysis of data from dust detectors aboard the Ulysses and Galileo spacecraft have revealed that there is a stream of interstellar dust flowing through our solar system. These grains will be captured during the cruise phase of the STARDUST mission, as the spacecraft travels toward the comet. The sample return capsule will parachute to Earth in February 2006, and will land in western Utah. Once on y the ground, the sample return capsule will be placed into a dry nitrogen environment and flown to the curation lab at JSC.

Zolensky, Michael E.↗

Lipid Decontamination Procedures for Life Detection Missions

Molecular biosignatures are key targets for current, proposed, and future life detection missions. With the high accuracy and low limit of detection (LOD) that new and future instruments will require, decontamination of life detection hardware is necessary to prevent false positives. Lipids are a molecular biosignature of interest, as they are ubiquitous to all life as we know it, can survive unaltered in the geologic record for longer than any other biomolecule (i.e. billions of years), and form through both biotic and abiotic processes. Lipids display origin-diagnostic molecular patterns that can reveal biotic or abiotic synthesis, so finding them and ascertaining their molecular features is important for potentially detecting evidence of life elsewhere. Traditional methods of decontamination, or contamination control (CC), primarily clean hardware through fabrication in sterile (cleanroom) environments, killing microbes, and removing/flushing contaminants off instrument and spacecraft components. However, research suggests that some standard cleaning methods are either unlikely to remove lipid contaminants or are incompatible with life detection instrument materials. To solve this problem, I propose to find, test, and verify a decontamination method that thoroughly cleans instruments by destroying lipid molecules, but is simultaneously compatible with major materials used in these instruments. I will study the effects of traditional CC methods (including Dry Heat Microbial Reduction and Vapor phase Hydrogen Peroxide) and experimental CC methods (Electron Beam Irradiation) on lipid molecules for application to life detection instrumentation. I will then develop a CC plan for a novel lipid detector (ExCALiBR, Extractor for Chemical Analysis of Lipid Biomarkers in Regolith) searching for lipids in either soil or icy world scenarios. This plan will uphold planetary protection regulation requirements and validate experimental analyses of in-situ life detection tests.

Decontamination↗

Phase-Noise and Amplitude-Noise Measurement of Low-Power Signals

Measuring the phase fluctuation between a pair of low-power microwave signals, the signals must be amplified before detection. In such cases the phase noise of the amplifier pair is the main cause of 1/f background noise of the instrument. this article proposes a scheme that makes amplification possible while rejecting the close in 1/f (flicker) noise of the two amplifiers. Noise rejection, which relies upon the understanding of the amplifier noise mechanism does not require averaging. Therefore, our scheme can also be the detector of a closed loop noise reduction system. the first prototype, compared to a traditional saturated mixer system under the same condition, show a 24 dB noise reduction of the 1/f region.

phase noise↗

Pixel-Strip Module Testing and Performance Analysis for the CMS Phase-2 Outer Tracker Upgrade

In response to the demanding environment of the High-Luminosity Large Hadron Collider (HL-LHC), the Compact Muon Solenoid (CMS) Experiment's Outer Tracker is being replaced with a lighter, higher-granularity, radiation-tolerant silicon detector capable of providing tracking information directly to the Level-1 trigger system. The new Outer Tracker consists of Pixel-Strip (PS) and Strip-Strip (2S) transverse momentum (pT) modules, which are assembled and tested at, among other centers, Fermilab's Silicon Detector Facility. PS modules consist of a pixel sensor, a strip sensor, and multiple application-specific integrated circuits (ASICs). This poster studies the performance of MaPSAs, silicon macro-pixel sensors bump-bonded to 16 macro-pixel ASICS. It presents the testing procedures for MaPSAs and MaPSA-strip sensor sub-assemblies, as well as the results of calibration and performance studies of two PS modules before and after irradiation. These results assess the impact of irradiation on module performance, providing insight into the modules' expected performance in the HL-LHC environment.

Kimrey, Emerson [Scripps College]↗

Measurement of the Z boson invisible width at $\sqrt{s}=13$ TeV with the ATLAS detector

A measurement of the invisible width of the Z boson using events with jets and missing transverse momentum is presented using 37 fb -1 of 13 TeV proton–proton data collected by the ATLAS detector in 2015 and 2016. The ratio of Z → inv to Z → ℓℓ events, where inv refers to non-detected particles and ℓ is either an electron or a muon, is measured and corrected for detector effects. Events with at least one energetic central jet with p T ≥ 110 GeV are selected for both the Z → inv and Z → ℓℓ final states to obtain a similar phase space in the ratio. The invisible width is measured to be 506 ± 2 (stat.) ± 12 (syst.) MeV and is the single most precise recoil-based measurement. The result is in agreement with the most precise determination from LEP and the Standard Model prediction based on three neutrino generations.

13000 GeV-cms↗

Recurrent brief X-ray bursts from the globular cluster NGC 6624

Observational data are presented on ten brief X-ray bursts, recurrent at nearly equal time intervals, recorded during a two-day observation of 3U 1820-30 in the globular cluster NGC 6624 with the wide-field modulation collimator detectors on the SAS-3 X-ray observatory. The occurrence times were fitted by least squares to a linear sequence with an rms deviation of 621 sec, corresponding to a phase jitter of 3.9%. The bursts were observed in two energy channels. For a sequence of five of the most clearly observed bursts, the 2-6 keV rate rose to its peak value in about 1 sec and then decayed to preburst level in about 10 sec. The 6-11 keV rate rose more slowly and decayed similarly. The smooth decay of their averaged light curve suggests the temporal evolution may have a geometrical origin, where Compton scattering in a surrounding cloud of hot plasma stretches the pulse out and causes a progressive hardening of the spectrum.

Clark, G. W.↗