Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Spatially resolved probing of Preisach density in polycrystalline ferroelectric thin films

Applications of the ferroelectric materials for the information storage necessitate the understanding of local switching behavior on the level of individual grains and microstructural elements. In particular, implementation of multilevel neuromorphic elements requires the understanding of history-dependent polarization responses. Here, we introduce the spatially resolved approach for mapping local Preisach densities in polycrystalline ferroelectrics based on first-order reversal curve (FORC) measurements over spatially resolved grid by piezoresponse force spectroscopy using tip-electrode. The band excitation approach allowed effective use of cantilever resonances to amplify weak piezoelectric signal and also provided insight in position-, voltage-, and voltage history-dependent mechanical properties of the tip-surface contact. Several approaches for visualization and comparison of the multidimensional data sets formed by FORC families or Preisach densities at each point are introduced and compared. The relationship between switching behavior and microstructure is analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combined quantitative ultrasonic and time-resolved interaction force AFM imaging

The authors describe a method where quantitative ultrasonic atomic force microscopy (UAFM) is achieved during time-resolved interaction force (TRIF) imaging in intermittent contact mode. The method uses a calibration procedure for quantitative UAFM. It improves elasticity measurements of stiff regions of surfaces while retaining the capabilities of the TRIF mode for topography, adhesion, dissipation, and elasticity measurements on soft regions of sample surfaces. This combination is especially advantageous when measuring and imaging samples with broad stiffness range in a nondestructive manner. The experiments utilize an active AFM probe with high bandwidth and the UAFM calibration is performed by measuring the magnitude of the time-resolved UAFM signal at a judiciously chosen frequency for different contact stiffness values during individual taps. Improved sensitivity to stiff surface elasticity is demonstrated on a special sample. The results show that combining UAFM with TRIF provides 2.5 GPa (5%) standard deviation on the silicon surface reduced Young's modulus, representing 5x improvement over using only TRIF mode imaging.

42 ENGINEERING↗

Spatially resolved argon microplasma diagnostics by diode laser absorption

Microplasmas were diagnosed by spatially resolved diode laser absorption using the Ar 801.4 nm transition (1s{sub 5}-2p{sub 8}). A 900 MHz microstrip split ring resonator was used to excite the microplasma which was operated between 100-760 Torr (13-101 kPa). The gas temperatures and the Ar 1s{sub 5} line-integrated densities were obtained from the atomic absorption lineshape. Spatially resolved data were obtained by focusing the laser to a 30 {mu}m spot and translating the laser path through the plasma with an xyz microdrive. At 1 atm, the microplasma has a warm core (850 K) that spans 0.2 mm and a steep gradient to room temperature at the edge of the discharge. At lower pressure, the gas temperature decreases and the spatial profiles become more diffuse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spatially resolved lasers using a glassy cholesteric liquid crystal film with lateral pitch gradient

To fabricate spatially resolved glassy cholesteric liquid crystal (CLC) lasers, a lateral pitch gradient was introduced by thermally activated diffusion across the interface of two films comprising nematic and cholesteric oligofluorene doped with a red-emitting oligifluorene. The formation of spatially resolved Grandjean–Cano bands was accountable by strong surface anchoring at substrates and the qualitative chiral concentration profile. Across each band there was a common stop band, and a set of bands produced multiple lasing peaks across the spectral range determined by light-emitter’s fluorescence spectrum. The resultant lasing thresholds, 6.6–7.6 mJ/cm 2 , and slope efficiencies, 0.2%–1.5%, are superior to those reported to date for gradient-pitch CLC lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning photoelectron microscope for nanoscale three-dimensional spatial-resolved electron spectroscopy for chemical analysis

In order to achieve nondestructive observation of the three-dimensional spatially resolved electronic structure of solids, we have developed a scanning photoelectron microscope system with the capability of depth profiling in electron spectroscopy for chemical analysis (ESCA). We call this system 3D nano-ESCA. For focusing the x-ray, a Fresnel zone plate with a diameter of 200 {mu}m and an outermost zone width of 35 nm is used. In order to obtain the angular dependence of the photoelectron spectra for the depth-profile analysis without rotating the sample, we adopted a modified VG Scienta R3000 analyzer with an acceptance angle of 60 deg. as a high-resolution angle-resolved electron spectrometer. The system has been installed at the University-of-Tokyo Materials Science Outstation beamline, BL07LSU, at SPring-8. From the results of the line-scan profiles of the poly-Si/high-k gate patterns, we achieved a total spatial resolution better than 70 nm. The capability of our system for pinpoint depth-profile analysis and high-resolution chemical state analysis is demonstrated.

36 MATERIALS SCIENCE↗

Time- and angle-resolved x-ray diffraction to probe structural and chemical evolution during Al-Ni intermetallic reactions

We present novel time- and angle-resolved x-ray diffraction (TARXD) capable of probing structural and chemical evolutions during rapidly propagating exothermic intermetallic reactions between Ni-Al multilayers. The system utilizes monochromatic synchrotron x-rays and a two-dimensional (2D) pixel array x-ray detector in combination of a fast-rotating diffraction beam chopper, providing a time (in azimuth) and angle (in distance) resolved x-ray diffraction image continuously recorded at a time resolution of {approx}30 {micro}s over a time period of 3 ms. Multiple frames of the TARXD images can also be obtained with time resolutions between 30 and 300 {micro}s over three to several hundreds of milliseconds. The present method is coupled with a high-speed camera and a six-channel optical pyrometer to determine the reaction characteristics including the propagation speed of 7.6 m/s, adiabatic heating rate of 4.0 x 10{sup 6} K/s, and conductive cooling rate of 4.5 x 10{sup 4} K/s. These time-dependent structural and temperature data provide evidences for the rapid formation of intermetallic NiAl alloy within 45 {micro}s, thermal expansion coefficient of 1.1 x 10{sup -6} K for NiAl, and crystallization of V and Ag{sub 3}In in later time.

36 MATERIALS SCIENCE↗

Time-resolved soft x-ray absorption setup using multi-bunch operation modes at synchrotrons

Here, we report on a novel experimental apparatus for performing time-resolved soft x-ray absorption spectroscopy in the sub-ns time scale using non-hybrid multi-bunch mode synchrotron radiation. The present setup is based on a variable repetition rate Ti:sapphire laser (pump pulse) synchronized with the {approx}500 MHz x-ray synchrotron radiation bunches and on a detection system that discriminates and singles out the significant x-ray photon pulses by means of a custom made photon counting unit. The whole setup has been validated by measuring the time evolution of the L{sub 3} absorption edge during the melting and the solidification of a Ge single crystal irradiated by an intense ultrafast laser pulse. These results pave the way for performing synchrotron time-resolved experiments in the sub-ns time domain with variable repetition rate exploiting the full flux of the synchrotron radiation.

43 PARTICLE ACCELERATORS↗

Two-dimensional measurement of edge impurity emissions using space-resolved extreme ultraviolet spectrometer in Large Helical Device

A space-resolved extreme ultraviolet (EUV) spectrometer working in wavelength range of 50-500 A has been developed to measure two-dimensional distribution of impurity spectral lines emitted from edge plasma of Large Helical Device (LHD), in which the magnetic field is formed by stochastic magnetic field with three-dimensional structure called ergodic layer. The two-dimensional measurement of edge impurity line emissions is carried out by scanning horizontally the observation chord of the space-resolved EUV spectrometer during single LHD discharge. Images of CIV (312.4 A) and HeII (303.78 A) are presented as the first result. The results are compared with ones calculated from the edge chord length in the ergodic layer of LHD plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporally resolved plasma composition measurements by collective Thomson scattering in TEXTOR (invited)

Fusion plasma composition measurements by collective Thomson scattering (CTS) were demonstrated in recent proof-of-principle measurements in TEXTOR [S. B. Korsholm et al., Phys. Rev. Lett. 106, 165004 (2011)]. Such measurements rely on the ability to resolve and interpret ion cyclotron structure in CTS spectra. Here, we extend these techniques to enable temporally resolved plasma composition measurements by CTS in TEXTOR, and we discuss the prospect for such measurements with newly installed hardware upgrades for the CTS system on ASDEX Upgrade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deflection gating for time-resolved x-ray magnetic circular dichroism-photoemission electron microscopy using synchrotron radiation

In this paper, we present a newly developed gating technique for a time-resolving photoemission microscope. The technique makes use of an electrostatic deflector within the microscope's electron optical system for fast switching between two electron-optical paths, one of which is used for imaging, while the other is blocked by an aperture stop. The system can be operated with a switching time of 20 ns and shows superior dark current rejection. We report on the application of this new gating technique to exploit the time structure in the injection bunch pattern of the synchrotron radiation source BESSY II at Helmholtz-Zentrum Berlin for time-resolved measurements in the picosecond regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ multipurpose time-resolved spectrometer for monitoring nanoparticle generation in a high-pressure fluid

We developed a multipurpose time-resolved spectrometer for studying the dynamics of nanoparticles generated by pulsed-laser ablation (PLA) in a high-pressure fluid. The apparatus consists of a high-pressure optical cell and three spectrometers for in situ measurements. The optical cell was designed for experiments at temperatures up to 400 K and pressures up to 30 MPa with fluctuations within {+-}0.1% h{sup -1}. The three spectrometers were used for the following in situ measurements at high pressures: (i) transient absorption spectrum measurements from 350 to 850 nm to investigate the dynamics of nanoparticle generation from nanoseconds to milliseconds after laser irradiation, (ii) absorption spectrum measurements from 220 to 900 nm to observe the time evolution of nanoparticles from seconds to hours after laser ablation, and (iii) dynamic light scattering measurements to track nanoparticles with sizes from 10 nm to 10 {mu}m in the time range from seconds to hours after laser ablation. By combining these three spectrometers, we demonstrate in situ measurements of gold nanoparticles generated by PLA in supercritical fluids. This is the first report of in situ time-resolved measurements of the dynamics of nanoparticles generated in a supercritical fluid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-to-electron magnetic spectrometer (GEMS): An energy-resolved {gamma}-ray diagnostic for the National Ignition Facility

The gamma-to-electron magnetic spectrometer, having better than 5% energy resolution, is proposed to resolve {gamma}-rays in the range of E{sub o}{+-} 20% in single shot, where E{sub o} is the central energy and is tunable from 2 to 25 MeV. Gamma-rays from inertial confinement fusion implosions interact with a thin Compton converter (e.g., beryllium) located at approximately 300 cm from the target chamber center (TCC). Scattered electrons out of the Compton converter enter an electromagnet placed outside the NIF chamber (approximately 600 cm from TCC) where energy selection takes place. The electromagnet provides tunable E{sub o} over a broad range in a compact manner. Energy resolved electrons are measured by an array of quartz Cherenkov converters coupled to photomultipliers. Given 100 detectable electrons in the energy bins of interest, 3 Multiplication-Sign 10{sup 14} minimum deuterium/tritium (DT) neutrons will be required to measure the 4.44 MeV {sup 12}C {gamma}-rays assuming 200 mg/cm{sup 2} plastic ablator areal density and 3 Multiplication-Sign 10{sup 15} minimum DT neutrons to measure the 16.75 MeV DT {gamma}-ray line.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved multiple probe spectroscopy

Time-resolved multiple probe spectroscopy combines optical, electronic, and data acquisition capabilities to enable measurement of picosecond to millisecond time-resolved spectra within a single experiment, using a single activation pulse. This technology enables a wide range of dynamic processes to be studied on a single laser and sample system. The technique includes a 1 kHz pump, 10 kHz probe flash photolysis-like mode of acquisition (pump-probe-probe-probe, etc.), increasing the amount of information from each experiment. We demonstrate the capability of the instrument by measuring the photolysis of tungsten hexacarbonyl (W(CO){sub 6}) monitored by IR absorption spectroscopy, following picosecond vibrational cooling of product formation through to slower bimolecular diffusion reactions on the microsecond time scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

In recent years, a new generation of high repetition rate ({approx}10 Hz), high power ({approx}100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of {approx}1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photodissociation of gaseous CH{sub 3}COSH at 248 nm by time-resolved Fourier-transform infrared emission spectroscopy: Observation of three dissociation channels

Upon one-photon excitation at 248 nm, gaseous CH{sub 3}C(O)SH is dissociated following three pathways with the products of (1) OCS + CH{sub 4}, (2) CH{sub 3}SH + CO, and (3) CH{sub 2}CO + H{sub 2}S that are detected using time-resolved Fourier-transform infrared emission spectroscopy. The excited state {sup 1}(n{sub O}, {pi}{sup *}{sub CO}) has a radiative lifetime of 249 {+-} 11 ns long enough to allow for Ar collisions that induce internal conversion and enhance the fragment yields. The rate constant of collision-induced internal conversion is estimated to be 1.1 Multiplication-Sign 10{sup -10} cm{sup 3} molecule{sup -1} s{sup -1}. Among the primary dissociation products, a fraction of the CH{sub 2}CO moiety may undergo further decomposition to CH{sub 2}+ CO, of which CH{sub 2} is confirmed by reaction with O{sub 2} producing CO{sub 2}, CO, OH, and H{sub 2}CO. Such a secondary decomposition was not observed previously in the Ar matrix-isolated experiments. The high-resolution spectra of CO are analyzed to determine the ro-vibrational energy deposition of 8.7 {+-} 0.7 kcal/mol, while the remaining primary products with smaller rotational constants are recognized but cannot be spectrally resolved. The CO fragment detected is mainly ascribed to the primary production. A prior distribution method is applied to predict the vibrational distribution of CO that is consistent with the experimental findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnosing the plasma nonuniformity in an iron opacity experiment by spatially resolved Al 1s-2p absorption spectroscopy

Generating a well-characterized hot-dense sample is of great importance to high quality opacity measurements. In this paper, we report on an experimental investigation of the plasma nonuniformity in a radiatively heated iron opacity sample by spatially resolved Al 1s-2p absorption spectroscopy. The iron sample was tamped by plastic at both sides and was heated by thermal x-ray radiation generated in a gold Hohlraum, and an Al layer attached to it was used as a tracer for temperature diagnosis. Spatially resolved 1s-2p transition absorption spectra of the Al tracer were measured by the technique of point-projection-spectroscopy, and temperatures in the sample were obtained by comparing the measured spectra with detailed-term-accounting model calculations, with the density of the sample deduced using a combination of side-on radiography and radiative hydrodynamic simulation. The results showed the existence of axial temperature nonuniformity in the sample, and these temperature variations have been used to explain the shift of iron 2p-3d transition absorption feature along the axial direction of the Hohlraum used to heat the sample successfully.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum state-resolved gas/surface reaction dynamics probed by reflection absorption infrared spectroscopy

We report the design and characterization of a new molecular-beam/surface-science apparatus for quantum state-resolved studies of gas/surface reaction dynamics combining optical state-specific reactant preparation in a molecular beam by rapid adiabatic passage with detection of surface-bound reaction products by reflection absorption infrared spectroscopy (RAIRS). RAIRS is a non-invasive infrared spectroscopic detection technique that enables online monitoring of the buildup of reaction products on the target surface during reactant deposition by a molecular beam. The product uptake rate obtained by calibrated RAIRS detection yields the coverage dependent state-resolved reaction probability S({theta}). Furthermore, the infrared absorption spectra of the adsorbed products obtained by the RAIRS technique provide structural information, which help to identify nascent reaction products, investigate reaction pathways, and determine branching ratios for different pathways of a chemisorption reaction. Measurements of the dissociative chemisorption of methane on Pt(111) with this new apparatus are presented to illustrate the utility of RAIRS detection for highly detailed studies of chemical reactions at the gas/surface interface.

36 MATERIALS SCIENCE↗

Energy resolved X-ray grating interferometry

Although compatible with polychromatic radiation, the sensitivity in X-ray phase contrast imaging with a grating interferometer is strongly dependent on the X-ray spectrum. We used an energy resolving detector to quantitatively investigate the dependency of the noise from the spectral bandwidth and to consequently optimize the system-by selecting the best energy band matching the experimental conditions-with respect to sensitivity maximization and, eventually, dose. Further, since theoretical calculations of the spectrum are usually limited due to non-ideal conditions, an energy resolving detector accurately quantifies the spectral changes induced by the interferometer including flux reduction and beam hardening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗