Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Optimization of VISAR Mirrors for NIF Targets

The velocity interferometer system for any reflector (VISAR) is a key diagnostic at the National Ignition Facility that is used for measuring propagation and velocities of shocks through a sample for several high energy density campaigns. To support simultaneous measurements with VISAR and other diagnostics, optical mirrors are used to divert the VISAR signal off axis from the primary diagnostic line of sight, which can then be used for other measurements. Here, in this study, we describe our work on investigating issues with these mirrors to support complex new target geometries and signal variance due to system aging and more demanding polling rates. This paper also describes the key mitigation efforts performed to improve both the flatness and reflectivity of these commonly used mirrors.

National Ignition Facility↗

Multiobjective Optimization of Regional and Teleseismic Data to Constrain the Source of the 12 September 2016 Mw 5.4 Earthquake in South Korea

In this paper, we propose a new approach for source inversion with automatic criteria for the station selection process and using a multiobjective optimization scheme combining teleseismic body-wave and regional surface-wave observations. To illustrate the approach, we determine the source parameters of the 12 September 2016 M w 5.4 South Korea earthquake, as well as its foreshock (same day) and its main aftershock on 19 September 2016. Available teleseismic (short period and broadband) and regional (broadband) seismograms from the Incorporated Research Institutions for Seismology International–Federation of Digital Seismograph Networks (IRIS-FDSN) webservice are selected (see Data and Resources). First, all teleseismic data with signal-to-noise ratio (SNR) above 2 in the 0.3–1.5 Hz frequency band are selected and a cepstrum function is blindly applied to help detect reflected wave arrivals inside a P coda. This method allows the identification of records with weak P-coda and clear depth phase (pP, sP) arrivals and can be used to select an optimal set of teleseismic seismograms to be used for the inversion. Second, regional seismograms are selected according to the fit between their observed and theoretical dispersion curves extracted from local 1D velocity model. Depending on the epicentral distance, two frequency bands are proposed for regional data: 15–50 s for epicentral distances smaller than 2° and 30–80 s otherwise. Finally, we explore the space parameters from exhaustive grid searches for the two objective functions Tf and Rf for teleseismic and regional data, respectively. We show that the seismic moment parameters can be exclusively derived from Rf and can be fixed for Tf. However, the depth parameter is not sensitive to Rf and can be simultaneously inverted from both. The selection of the optimal solution satisfying both cost functions uses the optimum Pareto front that allows a decrease in epistemic uncertainty. Lastly, we discuss the advantage of this approach for improving the characterization of moderate earthquake sources in areas with limited regional instrumentation.

58 GEOSCIENCES↗

Abstract for CRADA between Solar Turbines Incorporated and NETL

The National Energy Technology Laboratory is developing the Raman Gas Analyzer (RGA) to be a fast, non-destructive instrument for on-line measurement of gas composition. The RGA has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, but Raman interaction is weak with gas phase substances. The RGA uses a reflectively lined capillary as the optical cell in a patented configuration, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (including CO, CO2, N2, O2, H2O). The RGA provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process, such as improving fuel flexibility and efficiency for power generation systems. NETL has constructed a field prototype of the RGA to test the instrument performance in various applications in fossil energy. The objective of this CRADA is to field test the Raman Gas Analyzer in a commercial or near-commercial gas turbine application, to advance its Technology Readiness Level and support technology transfer to the commercial marketplace.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Solar Turbines Incorporated

The National Energy Technology Laboratory is developing the Raman Gas Analyzer (RGA) to be a fast, non-destructive instrument for on-line measurement of gas composition. The RGA prototype has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, but Raman interaction is weak with gas phase substances. The RGA uses a reflectively lined capillary as the optical cell in a patented configuration, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (including CO, CO2, N2, O2, H2O). The RGA provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process, such as improving fuel flexibility and efficiency for power generation systems. NETL has constructed a field prototype of the RGA to test the instrument performance in various applications in fossil energy. Through this CRADA, the RGA prototype operation was tested using hydrocarbon mixtures and hydrogen on a combustor test rig for potential use in gas turbine engine testing. The testing was performed at the Solar Turbines Incorporated Harbor Drive facility in downtown San Diego, CA on December 3-7, 2018. The RGA was installed outside a combustor test bay, with a ¼" sample line connected from a point shortly upstream of the test combustor. The combustion test building online gas chromatograph reported analysis of a sample every 6 minutes. During testing, seven test conditions of pure gas or gas mixtures were supplied to a pressurized combustion test rig. A sample of the fuel gas was continuously analyzed using the RGA with a 1 second measurement and reporting time. For each test condition, once the steady condition was reached, the composition of the gas from the RGA measurements is reported, along with the expected composition from the flow meters, and the composition reported by the online gas chromatograph (GC). During this testing, the real-time measurement capability of the RGA was readily apparent. The composition changes occurring in real-time could be followed and observed to correspond to combustion behavior changes on the video monitor at the operator station. The largest concentration species were tracked well through the tests; however, from comparison of the RGA one-second data with the GC steady-state points, it appears the RGA had some difficulty with quantifying hydrocarbon mixtures, especially when some of the hydrocarbons were at low concentration. The difficulty was particularly noted for ethane and butane in these tests. The NETL team intends to address this in 2019. Moderate concentrations of nitrogen, carbon dioxide, and hydrogen (>10%) were readily observed in the spectral data and quantified closely to the GC measurements. While calibration data for propylene was collected in preparation for this testing, it was not observed during the testing, even when the test conditions had high concentrations of propane.

Source record↗

Compressive auto-indexing in femtosecond nanocrystallography

Ultrafast nanocrystallography has the potential to revolutionize biology by enabling structural elucidation of proteins for which it is possible to grow crystals with 10 or fewer unit cells. The success of nanocrystallography depends on robust orientation-determination procedures that allow us to average diffraction data from multiple nanocrystals to produce a 3D diffraction data volume with a high signal-to-noise ratio. Such a 3D diffraction volume can then be phased using standard crystallographic techniques."Indexing" algorithms used in crystallography enable orientation determination of a diffraction data from a single crystal when a relatively large number of reflections are recorded. Here we show that it is possible to obtain the exact lattice geometry from a smaller number of measurements than standard approaches using a basis pursuit solver.

97 MATHEMATICS AND COMPUTING↗

Design and performance of optimal detectors for guided wave structural health monitoring

Ultrasonic guided wave measurements in a long term structural health monitoring system are affected by measurement noise, environmental conditions, transducer aging and malfunction. This results in measurement variability which affects detection performance, especially in complex structures where baseline data comparison is required. This paper derives the optimal detector structure, within the framework of detection theory, where a guided wave signal at the sensor is represented by a single feature value that can be used for comparison with a threshold. Three different types of detectors are derived depending on the underlying structure’s complexity: (i) Simple structures where defect reflections can be identified without the need for baseline data; (ii) Simple structures that require baseline data due to overlap of defect scatter with scatter from structural features; (iii) Complex structure with dense structural features that require baseline data. The detectors are derived by modeling the effects of variabilities and uncertainties as random processes. Analytical solutions for the performance of detectors in terms of the probability of detection and false alarm are derived. A finite element model is used to generate guided wave signals and the performance results of a Monte-Carlo simulation are compared with the theoretical performance. initial results demonstrate that the problems of signal complexity and environmental variability can in fact be exploited to improve detection performance.

60 APPLIED LIFE SCIENCES↗

SU-E-J-261: Statistical Analysis and Chaotic Dynamics of Respiratory Signal of Patients in BodyFix

Purpose: To quantify respiratory signal of patients in BodyFix undergoing 4DCT scan with and without immobilization cover. Methods: 20 pairs of respiratory tracks recorded with RPM system during 4DCT scan were analyzed. Descriptive statistic was applied to selected parameters of exhale-inhale decomposition. Standardized signals were used with the delay method to build orbits in embedded space. Nonlinear behavior was tested with surrogate data. Sample entropy SE, Lempel-Ziv complexity LZC and the largest Lyapunov exponents LLE were compared. Results: Statistical tests show difference between scans for inspiration time and its variability, which is bigger for scans without cover. The same is for variability of the end of exhalation and inhalation. Other parameters fail to show the difference. For both scans respiratory signals show determinism and nonlinear stationarity. Statistical test on surrogate data reveals their nonlinearity. LLEs show signals chaotic nature and its correlation with breathing period and its embedding delay time. SE, LZC and LLE measure respiratory signal complexity. Nonlinear characteristics do not differ between scans. Conclusion: Contrary to expectation cover applied to patients in BodyFix appears to have limited effect on signal parameters. Analysis based on trajectories of delay vectors shows respiratory system nonlinear character and its sensitive dependence on initial conditions. Reproducibility of respiratory signal can be evaluated with measures of signal complexity and its predictability window. Longer respiratory period is conducive for signal reproducibility as shown by these gauges. Statistical independence of the exhale and inhale times is also supported by the magnitude of LLE. The nonlinear parameters seem more appropriate to gauge respiratory signal complexity since its deterministic chaotic nature. It contrasts with measures based on harmonic analysis that are blind for nonlinear features. Dynamics of breathing, so crucial for 4D-based clinical technologies, can be better controlled if nonlinear-based methodology, which reflects respiration characteristic, is applied. Funding provided by Varian Medical Systems via Investigator Initiated Research Project.

60 APPLIED LIFE SCIENCES↗

Pan-spectral observing system simulation experiments of shortwave reflectance and long-wave radiance for climate model evaluation

Abstract. Top-of-atmosphere (TOA) spectrally resolved shortwave reflectances and long-wave radiances describe the response of the Earth's surface and atmosphere to feedback processes and human-induced forcings. In order to evaluate proposed long-duration spectral measurements, we have projected 21st Century changes from the Community Climate System Model (CCSM3.0) conducted for the Intergovernmental Panel on Climate Change (IPCC) A2 Emissions Scenario onto shortwave reflectance spectra from 300 to 2500 nm and long-wave radiance spectra from 2000 to 200 cm –1 at 8 nm and 1 cm –1 resolution, respectively. The radiative transfer calculations have been rigorously validated against published standards and produce complementary signals describing the climate system forcings and feedbacks. Additional demonstration experiments were performed with the Model for Interdisciplinary Research on Climate (MIROC5) and Hadley Centre Global Environment Model version 2 Earth System (HadGEM2-ES) models for the Representative Concentration Pathway 8.5 (RCP8.5) scenario. The calculations contain readily distinguishable signatures of low clouds, snow/ice, aerosols, temperature gradients, and water vapour distributions. The goal of this effort is to understand both how climate change alters reflected solar and emitted infrared spectra of the Earth and determine whether spectral measurements enhance our detection and attribution of climate change. This effort also presents a path forward to understand the characteristics of hyperspectral observational records needed to confront models and inline instrument simulation. Such simulation will enable a diverse set of comparisons between model results from coupled model intercomparisons and existing and proposed satellite instrument measurement systems.

54 ENVIRONMENTAL SCIENCES↗

Photothermal heterodyne imaging of micron-sized objects

Micron-sized dye-doped polymer beads were imaged using transmitted/reflected light microscopy and photothermal heterodyne imaging (PHI) measurements. The transmitted/reflected light images show distinct ring patterns that are attributed to diffraction effects and/or internal reflections within the beads. In the PHI experiments pump laser induced heating changes the refractive index and size of the bead, which causes changes in the diffraction pattern and internal reflections. This creates an analogous ring pattern in the PHI images. The ring pattern disappears in both the reflected light and PHI experiments when an incoherent light source is used as a probe. When the beads are imaged in an organic medium heat transfer changes the refractive index of the environment, and gives rise to a ring pattern external to the beads in the PHI images. This causes the beads to appear larger than their physical dimensions in PHI experiments. This external signal does not appear when the beads are imaged in air because the refractive index changes in air are very small.

Bhandari, Janak (ORCID:0000000188423259)↗

Neutrinos from type Ia supernovae: The deflagration-to-detonation transition scenario

It has long been recognized that the neutrinos detected from the next core-collapse supernova in the Galaxy have the potential to reveal important information about the dynamics of the explosion and the nucleosynthesis conditions as well as allowing us to probe the properties of the neutrino itself. The neutrinos emitted from thermonuclear—type Ia—supernovae also possess the same potential, although these supernovae are dimmer neutrino sources. For the first time, we calculate the time, energy, line of sight, and neutrino-flavor-dependent features of the neutrino signal expected from a three-dimensional delayed-detonation explosion simulation, where a deflagration-to-detonation transition triggers the complete disruption of a near-Chandrasekhar mass carbon-oxygen white dwarf. We also calculate the neutrino flavor evolution along eight lines of sight through the simulation as a function of time and energy using an exact three-flavor transformation code. We identify a characteristic spectral peak at ˜10 MeV as a signature of electron captures on copper. This peak is a potentially distinguishing feature of explosion models since it reflects the nucleosynthesis conditions early in the explosion. We simulate the event rates in the Super-K, Hyper-K, JUNO, and DUNE neutrino detectors with the SNOwGLoBES event rate calculation software and also compute the IceCube signal. Hyper-K will be able to detect neutrinos from our model out to a distance of ˜10 kpc. Here, at 1 kpc, JUNO, Super-K, and DUNE would register a few events while IceCube and Hyper-K would register several tens of events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamics of Carrier Plasma and Thermal Waves in Ion Implanted Si with Varying Pump and Probe Wavelengths

Dynamics of the carrier plasma- and thermal-waves in ion implanted Si is studied using the Modulated Optical Reflectance (MOR) technique with varying pump and probe beam wavelengths. It is shown that selection of the pump and probe beam wavelengths allows control of the MOR signal behavior on Si samples implanted with a wide range of implantation energies and doses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-situ Raman spectroscopy and high-speed photography of a shocked triaminotrinitrobenzene based explosive

We have developed a single-shot Raman spectroscopy experiment to study at the molecular level the initiation mechanisms that can lead to sustained detonation of a triaminotrinitrobenzene-based explosive. Shocks up to 30 GPa were generated using a two-stage laser-driven flyer plate generator. The samples were confined by an optical window and shock pressure was maintained for at least 30 ns. Photon Doppler Velocimetry measurements were performed at the explosive/window interface to determine the shock pressure profile. Raman spectra were recorded as a function of shock pressure and the shifts of the principal modes were compared to static high-pressure measurements performed in a diamond anvil cell. Our shock data indicate the role of temperature effects. Our Raman spectra also show a progressive extinction of the signal which disappears around 9 GPa. High-speed photography images reveal a simultaneous progressive darkening of the sample surface up to total opacity at 9 GPa. Reflectivity measurements under shock compression show that this opacity is due to a broadening of the absorption spectrum over the entire visible region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Buried Dirac Points in Quantum Spin Hall Insulators: Implications for Majorana Kramers Pair-Based Quantum Computing

Quantum spin Hall insulators (QSHIs) host helical electronic edge states that are protected from backscattering due to time-reversal symmetry (TRS). Despite considerable work investigating QSHI edge states, there is still an open question about their unexpected resilience to large magnetic fields where TRS is undoubtedly broken. In this work, we investigate the transport properties of helical edge states in a QSHI-superconductor (QSHI-SC) junction formed by a In⁢As(15 nm)/Ga⁢Sb(5 nm) double quantum well and a superconducting tantalum (Ta) constriction. We observe a robust conductance plateau up to 2 T, signaling resilient edge-state transport. Using a modified Landauer-Büttiker analysis, we find that the zero-field conductance is consistent with 98% Andreev-reflection probability owing to the high transparency of the (In⁢As/Ga⁢Sb)-Ta interface. Such resilience is consistent with the Dirac point for the edge states being buried in the bulk valence band. We further theoretically show that a buried Dirac point does not affect the robustness of the quasi-one-dimensional topological superconducting phase. We find that a buried Dirac point favors the hybridization of Majorana Kramers pairs (MKPs)—predicted to exist in a QSHI-SC constriction—and fermionic modes in the QSHI vacuum edge resulting in extended MKP states, highlighting the subtle role of buried Dirac points in probing MKPs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FINAL REPORT

Excellent progress was made in standardizing three complementary methods: Magnetic resonance imaging, x-ray micro CT, and MALDI imaging linear ion trap mass spectroscopy to image biomass and chemical, anatomical and functional changes that occur during pretreatment and hydrolysis. Magnetic resonance microscopy provides excellent images with as low as 5 uM resolution with hydrated biomass samples. We visualized dramatic changes in signal associated with the hydrolysis of the carbohydrates by strong acids. Quantitative diffusion approaches were used to probe more subtle structural changes in biomass. Diffusion tensor calculations reflect diffusion anisotropy and fractional anisotropy maps clearly show the longer range diffusion within the vessels compared to within the fiber cells. The diffusion is increased along the cell walls of the vessels. Suggesting that further research with NMR imaging should be pursued. X-ray CT provides excellent images at as low as 3.5 uM resolution from dried biomass. Small increases in surface area, and decreases in local density have been quantified in with wood after mild pretreatments; these changes are expected to be underestimates of the hydrated wood, due to the ~12% shrinkage that occurs upon drying untreated wood. MALDI-MS spectra show high ion intensities at most mass to charge ratios in untreated and pretreated woody material. MALDI-MSn is required to improve specificity and reduce background for imaging. MALDI-TOF is not specific enough for carbohydrate identification. Using MALDI-LIT/MSn we can readily identify oligomeric glucans and xylans and their fragmentation patterns as well as those of the glucuronic acid side chains of birch 4-O-methyl glucuronxylan. Imaging of glucan and xylan oligomers show that many contain isobaric ions with different distributions, indicating again that MSn is needed for accurate imaging of lignocellulosic materials. We are now starting to integrate the three imaging methods by using the same set of biomass samples imaged with all three methods, and using common analytical software to quantify parameters from the three dimensional images. In addition to the proposed experiments, we conducted imaging studies with a novel TOF-SIMS instrument available through collaborations with the AMOLF goup led by Ron Heeren at the FOM Institute in Amersterdam, Netherlands. ToF-SIMS was used to image intact cross sections of Populus stems with high spatial resolution, chemically selectivity. ToF-SIMS images were correlated with fluorescence microscopy which allowed for more positive ion identification.

09 BIOMASS FUELS↗

Light Water Reactor Sustainability Program Potential to Extend the Range of Established Online Monitoring Technologies, Such as Guided Waves in Nuclear Power Plant Systems

The Light Water Reactor Sustainability Program began to evaluate technologies that could be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real-time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for most nuclear power generation costs. This report describes the current state of research related to ultrasonic guided wave testing and its application to defect detection in commercial nuclear power plants. The report analyses the applicability of the guided wave technology to secondary piping systems and also study the potential for expanding the range of guided wave technology to include bent piping and other piping components. The ultrasonic guided waves can inspect long stretches of straight piping, however more complex geometries such as elbows, welds, and tees are causing spurious reflections and coherent noise which significantly decrease the sensitivity of the technique. The report analyses two approaches to suppression of coherent noise in guided wave systems: advanced signal processing and pattern recognition based on independent component analysis and blind source separation and hardware-based technique of piezoelectric paint which can be used to facilitate the propagation of mechanical stress waves through piping. It is demonstrated on simulated guided wave data that the independent component analysis is capable of separating different coherent noise components and segregating them from useful signal. The piezoelectric paint approach seem to be a viable alternative to the signal processing methods, however it requires significantly more complicated logistics and initial financial outlay. The future efforts will be concentrated on applying the independent component analysis to real-world guided wave data recorded by the guided wave monitoring system installed on the shell of the low-pressure feedwater heater 13A at Exelon Corporation’s Braidwood Nuclear Generating Station. Also, the joint EPRI-INL research efforts will focus on experimental evaluation of piezoelectric paint as a technique to extend the range of guided wave technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IDC Re-Engineering Phase 2 Iteration E2. Draft Component Interface Specification

This report contains a draft Component Interface Specification (CIS) for a signal detector. It is an example of the contents and level of detail of information in a CIS. The classes, interfaces, and data types in this report reflect current understanding of system concepts and potential implementation patterns but should not be interpreted as containing the finalized interface specifications, etc.

42 ENGINEERING↗

Three-dimensional simulations of National Ignition Facility implosions: Insight into experimental observables

We simulate in 3D both the hydrodynamics and, simultaneously, the X-ray and neutron diagnostic signatures of National Ignition Facility (NIF) implosions. We apply asymmetric radiation drive to study the impact of low mode asymmetry on diagnostic observables. We examine X-ray and neutron images as well as neutron spectra for these perturbed implosions. The X-ray images show hot spot evolution on small length scales and short time scales, reflecting the incomplete stagnation seen in the simulation. The neutron images show surprising differences from the X-ray images. The neutron spectra provide additional measures of implosion asymmetry. Flow in the hot spot alters the neutron spectral peak, namely, the peak location and width. The changes in the width lead to a variation in the apparent temperature with viewing angle that signals underlying hot spot asymmetry. We compare our new expectations based on the simulated data with NIF data. We find that some recent cryogenic layered experiments show appreciable temperature anisotropy indicating residual flow in the hot spot. We also find some trends in the data that do not reflect our simulation and theoretical understanding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗